Tender For Repair To Septic Tanks, Soakage Wells And Misc Sewage Works At Rms Chail Under Ge (I) Jutogh, chail-Himachal Pradesh

Military Engineer Services-MES has published Tender For Repair To Septic Tanks, Soakage Wells And Misc Sewage Works At Rms Chail Under Ge (I) Jutogh. Submission Date for this Tender is 21-10-2023. Kitchen Equipment Tenders in chail Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

39833465
Corrigendum : Tender For Repair To Septic Tanks, Soakage Wells And Misc Sewage Works At Rms Chail Under Ge (I) Jutogh
Open Tender
Indian
Himachal Pradesh
chail
21-10-2023

Tender Details

Tender For Repair To Septic Tanks, Soakage Wells And Misc Sewage Works At Rms Chail Under Ge ( I ) Jutogh ; 1 Dismantling Of 100Mm Cast Iron Or Reinforced Concrete Drain Pipe, Jointed In Cement Mortar And Taking Out Of Trenches / Floor / Wall If Required Complete All As Specified And Directed. 2 S&F For 100 Mm Bore Cast Iron ( Sand Cast Pipe ) Soil, Waste And Vent Pipes In Any Length With Or Without Ears, With Cement Joints, Fixed To Wall Complete All As Specified And Directed. 3 Cleaning The Septic Tank / Sludge Chamber Of Any Depth / Area / Condition Incl Taking Outstagnated Sludge Or Any Other Material Mixed With The Sludge Etcdeposited In The Septic Tanks, Filling In Closed Container And Depositing In Excavated Pit, Covering The Pit At Least 500M Beyond Nearby Living Accn Or Area As Marked By Station Controlling Authority With Earth After Depositing Sludge, Sprinkling Fresh Lime On Covered Pit And Around Septic Tanks / Soakage Wells To Make It Hygenic Complete All As Specified And Directed.Note:- ( I ) Cost Of Pumping With Mechanical Sewage Pump, Excavation Of Earth Pit And Fresh Lime Shall Be Deemed To Include In The Rate Quoted. ( Ii ) Charges Of Covered Container Incl Its Transportation Shall Be Deemed To Include In The Rate Quoted. ( Iii ) Depth Of Liquid Sludge In The Septic Tank Will Be Determined And Recorded Before Commencement Of Work By Any Engg Conventional Method In The Presence Of Engr-In Charge And Contractor. 4 Comprehenshive Maintenance And Cleaning Of Sewage System Including Sewage Lines, Manholes, Soakage Wells / Soak-Pits, Gully Traps, Septic Tanks Attending Bloakages In Wcs / Whbs / Drains Etc By Employing Necessary Resources Including T&P Atrms Chail Complete All As Specified And Directed.The Location / Building / Complex Where Work Is To Be Carried Out Consist Of The Following:- ( A ) All Otm And Md Accn Atrms Chail .Notes:- ( I ) The Contractor Will Employe A Supervisor. The Supervisor So Employed Shall Report To The Concerned Je Daily To Give Feed Back And Also To Receive Day To Day Sewage Complaints And Necessary Instructions For Smooth Running Of The Contract. ( Ii ) He Will Carry Out Normal Maintenance To Sewage System As Required At Site. ( Iii ) For Any Default / Delay In Attending The Complaints Recovery Shall Be Effected As Per Contract Conditions Provided Here-In-After. ( Iv ) T & P As Requiered For The Work Shall Be Arranged By The Contractor Without Any Extra Cost To The Deptt. ( V ) Supervisor Engaged By The Contractor Shall Take All Necessary Preventative Safety Measures And Adequate Precautions To Avoid Any Health Hazard And Department Shall Not Be Held Responsible For Any Unwanted Incidence. 5 Cleaning Of Sgsw / Cipipe Lines Laid In Trenches Or Fixed To Wall / Floor Incl Desilting / Desludging Intermediate Manholes Of Any Size And Depth, Removing Sludge Outside Of Mod Land In A Covered Container, Atleast 500 M Beyond Nearby Living Accn, Depositing The Sludge In A Excavated Pit, Covering The Pit With Earth After Depositing Sludge, Sprinkling Fresh Lime Over The Pit And Around Manholes Complete All As Specified And Directed.Note : Charges Of Covered Container Incl Its Transportation Charges, Cost Of Fresh Lime And Earth Pit Shall Be Deemed To Include In The Rate Quoted. 6 100Mm Internal Dia Of Pipe Line, Complete All As Specified And Directed. 7 150Mm Internal Dia Of Pipe Line, Complete All As Specified And Directed. 8 M&L For Cleaning / Removal Of Blockage Of Floor Traps / Nahani Traps Of 75Mm / 100Mm Bore In Kitchn / Bathrooms / Toilets Etc Up To 1St Manhole Including Of Taking Down Pvc / Stainless Trap Grating And Refixing The Same With White Cement With Pigment To Match The Surfsce As Before Or Any Other Associated / Related Complaints Not Mentioned Under This Item And Will Be Done As Complete All As Specified And Directed.Note:- The Traps Shall Be Measured More Than One Times As Per Requirement And Directed By Engr-In-Charge. 9 M&L For Cleaning / Removal Of Blockage Of Gully Trapsup To 1St Manhole Of Any Size And Any Depth Including Removing Rcc Manhole Covers And Refixing The Same As Beforeany Other Associated / Related Complaints Not Mentioned Under This Item And Will Be Done As Directed By Engr-In-Charge.Note:- The Gullytraps Shall Be Measured More Than One Times As Per Requirement And Directed By Engr-In-Charge. 10 M&L For Cleaning / Removal Of Blockage Of Orissa Pattern Wc P / S Trap And Making Fuctional Up To 1St Manhole Or Any Other Associated / Related Complaints Not Mentioned Under This Item And Will Be Done As Directed By Engr-In-Charge. Note:- The Wcshall Be Measured More Than One Times As Per Requirement And Directed By Engr-In-Charge. 11 M&L For Cleaning / Removal Of Blockage Of Europian Pattern Wc P / S Trap And Making Fuctional Up To 1St Manhole Or Any Other Associated / Related Complaints Not Mentioned Under This Item And Will Be Done As Directed By Engr-In-Charge. Note:- The Ewcshall Be Measured More Than One Times As Per Requirement And Directed By Engr-In-Charge. 12 M&L For Cleaning / Removal Of Blockage Of Europian Pattern Wc P / S Trap And Including Removing Ewc And Cleaning The Traps Completely And Making Functional And Refitting The Ewc In Same Position Including Making Good The Disturbed Surfaces With White Cement And Pigment To Match The Existing Surface Or Any Any Other Associated / Related Complaints Not Mentioned Under This Item And Will Be Done As Directed By Engr-In-Charge.Note:- The Ewcshall Be Measured More Than One Times As Per Requirement And Directed By Engr-In-Charge. 13 Excavation In Trenchesin Hard / Densesoil N. Exc 1.5M Wide And N. Exc 1.50M Deep And Getting Out Complete All As Specified And Directed. 14 Demolition And Breaking Up 150Mm Dia Drain Pipes ( Salt Glazed Ware, Ac ) Set In Cement Mortar Complete All As Specified And Directed. 15 M&L For Pcc 1:4:8, Type D-2, Using40mm Graded Crushed Stone Aggregate As In Concrete Bed Todrain Pipes Laid In Trenches In Any Depth Incl Packing Under & Haunchingagainst The Side Of 150Mm Bore ( Sgwac ) Pipe With Concrete After The Pipesare Laid And Testedcompelete All As Specified And Directed. 16 S&F 150Mm Dia Salt Glazed Stone Ware Drain Pipe And Jointed Complete All As Specified And Directed. 17 Returning Filling In Andincluding Spreading, Leveling And Well Ramming N.Exc 25 Cm Thick Inhard And Dense Soil Complete All As Specified And Directed. 18 Removing Excavated Materials N.Exc 50 M And Depositing Where Diretected At A Level N.Exc 1.5 M Above The Starting Point In Soil Complete All As Specified And Directed. 19 Demolition Of Brickmasonry / Stone Masonry Built In Cement Mortar Including All Quious, Pillars Arches Etc Complete All As Specified And Directed. 20 Demolition Of Cement Concrete ( Unreinforced ) Of Any Description In Ground Floors And Pavings N Exc 15 Cm Thickness ( Below Or Above Ground Level ) Complete All As Specified And Directed. 21 M&L For Pcc1:5:10, Type E-2, Using 40Mm Graded Crushed Stone Aggregate As In Foundation Filling And Mass Concrete Complete All As Specified And Directed. 22 M&L For Walling Of Random Rubble Stone Masonry Uncoursed Well Bonded, Bedded And Solidly Hearted, Built In Cm 1:6 Complete All As Specified And Directed. 23 All As Per Item No. 20.00 Above But Except Stone Complete All As Specified And Directed. 24 M&L For Brick Work, With Sub ClassB Brickstraight Or Curvedd On Plan Exc 6M Means Radius Built In Cement Mortor ( 1: 6 ) As In Manholes And Septic Tanks Complete All As Specified And Directed. 25 M&L For Brick Work, With Sub ClassB Brickstraihgt Or Curved On Plan To Any Radius In Half Brick Work Thick Wall Built In Cement Mortor ( 1: 4 ) As In Manholes And Septic Tanks Complete All As Specified And Directed. 26 M&L For Rendering 15Mm Thick In Cm 1:4 On Fair Faces Of Brick Workorconcrete Surfacesfinished & Evenand Smooth Mixed Withwater Proofing Compound Complete All As Specified And Directed. Note : Wpc Will Be Measured And Paid Separately Under Respective Item Of Boq 27 Supply Only Integrated Water Proofing Compound Complete All As Specified And Directed . 28 M&L For Pcc 1:2:4 Type B-1 Using 20 Mm Graded Stone Aggregate As In Cills, Steps, Seismic And Other Similar Works Plinth Course, Coping Benching, Bed Plate Etc Complete All As Specified And Directed. 29 Demolition Of Reinforcedcement Concreteof Any Description And In Position Not Otherwise Specificallyprovided For Complete All As Specified And Directed. 30 M&L Forprecast Reinforced Concrete 1:2:4, Type B-1Using 20 Mm Gradedcrushed Stone Aggregate As Incover Slabs Set In Cement Concrete 1:4 Placed In Position Over Manholes Etc Including Use And Waste Of Necessary Formwork Complete All As Specified And Directed.Note :- Reinforcementshall Be Measured And Paid Seperately. 31 M&L For Formwork To The Edges Of Concrete Flats, Treads, Breaks In Floors, Window Cills, Concrete Railings Exc 5Cm But N.Exc 10Cm Wide, Roughed Finished Surfaces Of Concrete Complete All As Specified And Directed. 32 S&F Mild Steel Bars 10Mm Dia And Over, Cut To Length, Bent To Shape Required Including Crancking Bending Spirally For Hooping For Columns, Hooking Ends And Binding With And Including Mild Steel Wire Not Less Than 0.5Mm Dia Or Securing With Clips Quality Confirming To Deformed Or Twisted Bars Complete All As Specified And Directed. 33 Cutting In To Existing Manholes Forconnecting Drain Pipes Making Good To Pipe And Rendering Cutting Out Existing Benches For And Forming Branch Channel ( 1 / 2 Round Or 3 / 4 Section ) In Cement Concrete ( 1:2:4 ) Type B1 Smooth Finished And Reforming Benching As Required For 150 Mm Internal Bore Pipe Complete All As Specified And Directed. 34 S & F Bands, Straps, Supports Or Stays For Rainwater, Ventilating Pipes, Including Bolts, If Required, Hooks ( Stay ) , Heavy, For Large Gates, Hook And Pintle Hinges, Large Hasps And Staples, Chains, Hand Made Sliding Bolts, Clamps, Hold Fasts, Wall Ties, Hooks For Hanging Fans, Plain Angle Cleats For Securing Purlins To Wood Trusses Or Rafters, Knee Piece Inserts, Two Way And Three Way Straps, Plate Washers And Similar Small Articles Conforming To Fe 410-0 Or Fe 310-0 Complete All As Specified And Directed. 35 S & F In Repair Pvc ( Swr ) Pipes110 Mm Bore Dia Single Socketed In Any Length With Rubber Ring Joints, Laid In Trenches Or In Floors Complete All As Specified And Directed. 36 S & F In Repairpvc ( Swr ) Pipes 75 Mm Bore Dia Single Socketed In Any Length With Rubber Ring Joints, Laid In Trenches Or In Floors Complete All As Specified And Directed. 37 S&F Pvc ( Swr ) Bends 75 Mm Bore Of Any Radius Complete All As Specified And Directed. 38 S&F Pvc ( Swr ) Bends 110 Mm Bore Of Any Radius Complete All As Specified And Directed. 39 M&L For Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding ( But Not Backing ) , Removing Serviceable Tiles To Store And Rubbish Off The Premises Complete All As Specified And Directed. 40 S & F Glazed Ceremic Coloured Tiles Of Size 300 Mm X 450 Mm X 7 Mm Thick As In Dados, Skirting, Wall Etc Set Jointed In Neat Cement Slurry And Pointed In Coloured Cement To Match The Tiles Over 15 Mm Thick Rendering In Cm 1 : 4 Complete All As Specified And Directed. 41 S&F Coloured Non Skid Ceramic Joint Free Tiles 7 To 8Mm Thickarea Of Each Tile Exc 0.06 Sqm But N Exc 0.11 Sqm In Floors, Set And Jointed In Neat Cement Slurryand Pointed In White Cement With Pigment To Match, Laid Over And Including 15Mm Thick Cement Screed Bed In Cement Mortar 1:6 Complete All As Specified And Directed. 42 S&F In Repairvitreous China Wash Down Water Closet Pan ( Pedestal Pattern ) White ( Excluding Fixing Bolts Flushing Cistern And Flush Pipe ) Etc Complete All As Specified And Directed. 43 S & F In Repair Vitreous China Wash Basin, White, Flat Back, Size 550X400mm Including Cutting For And Pinning In Ends Of Brackets Or Erecting Standincl Pillar Tap Cp 15 Mm Bore Complete All As Specified And Directed. 44 S&F In Repairsvitrous China Squatting Pan Orissa Pattern Of Size 580X440 Mm Complete All As Specified And Directed. 45 S&F In Repair 10 Litres Capacity Pvc Low Level Valve Less Symphonic Action Type Flushing Cistern White With Inlet, Ball Valve, Float And Handle Including Brackets And Flushing Pipe Etc Complete All As Specified And Directed. 46 M&L For 75Mm Bore Dia Cast Iron Floor Trap, With Grating Including Jointing To Waste Pipe Fixed In Cement Concrete 1:2:4 Type B-1Complete All As Specified And Directed. 47 S&F In Repair 15Mm Dia Bib Taps, Cast Copper Alloy, Chromium Plated With Crutch Orbutterfly Handle, Screwed Down, Screwed For Iron Pipe Or For Brass Ferrulecomplete All As Specified And Directed. 48 S & F In Repair 15 Mm Bore Chromium Plated Stop Valve, Cast Copper Alloy, With Crutch Or Butterfly Handle, Screwed Down, Screwed For Iron Pipe Or For Brass Ferrule Complete All As Specified And Directed. 49 M&L For Pcc 1:3:6, Type C-2, Using 40Mm Graded Crushed Stone Aggregate As In Surface Channel And Drains Complete All As Specified And Directed. 50 M&L For Forming Fair Finished Drain Or Channel 60Cm Inner Girth In Cement Concrete, Using Extra Cement Including Forms Moulds, Mitred / Stopped Ends Etc Complete All As Specified And Directed. 51 S & F In Repair Ball Brass Valves, High Pressure, With Polythene Float And Flynut Complete, Screwed For Iron Pipe Or Brass Ferrule And Fixed In Repairs15 Mm Bore Complete All As Specified And Directed. 52 Demolition Of Cement Concrete As In Sunken Portion And Pavings Exc 15 Cm Thicknessabove Ground Floors Complete All As Specified And Directed. 53 M&L For Pcc 1:5:10, Type E-2, Using 40Mm Graded Brick Aggregate As In Sunkenflooring Complete All As Specified And Directed. 54 M&L For Rendering / Screed Bed 15Mm Thick In Cm 1:3 In ( Sunken Slab ) Mixed With Water Proofing Compound As Per Manufacturer InstructionS Surface Shall Be Finished Even And Smooth Without Extra Cement Complete All As Specified And Directed. Note: Water Proofing Compound Shall Be Measured And Paid Separately. 55 M&L For Priming Surfaces And Applying Heavy Treatment ( For Severe Conditions ) , Using Glass Fibre Base Bitumen Felt, Grade 2, Complete All As Specified And Directed. 56 Taking Down Gi Tubing 15 Mm Dia And Connection Including Cleaning For Refixing Or Removal To Store Complete All As Specified And Directed. 57 Taking Down Gi Tubing 20 Mm Dia And Connection Including Cleaning For Refixing Or Removal To Store Complete All As Specified And Directed. 58 S&F Gi Tubing 15 Mm Bore Fixed To Wall / Ceiling Or Floorcomplete All As Specified And Directed. 59 S&F Gi Tubing 20 Mm Bore Fixed To Wall / Ceiling Or Floorcomplete All As Specified And Directed. 60 Cleaning And Removing All Scale And Dirt, Etc, From Tanks And From Mouths Of Circulating Pipes, Etc. Exc 250 But N Exc 500 Litres Complete All As Specified And Directed. 61 Cleaning And Removing All Scale And Dirt, Etc, From Tanks And From Mouths Of Circulating Pipes, Etc. Exc 500 But N Exc 1000 Litres Complete All As Specified And Directed. 62 Cleaning And Removing All Scale And Dirt, Etc, From Tanks And From Mouths Of Circulating Pipes, Etc. Exc 1000 But N Exc 2000 Litres Complete All As Specified And Directed. 63 S&F Pvc Connection 450 Mm Long Suitable For 15 Mm Bore Pipe Including Ptmt Nuts Complete All As Specified And Directed. 64 S&F Pvc Connection 900 Mm Long Suitable For 15 Mm Bore Pipe Including Ptmt Nuts Complete All As Specified And Directed. 65 S&F Chromium Plated Grating 125 Mm Dia Circular Of Approved Make And Fixing With Cement Mortar 1:3 On Nahani Trap Or Floor Trap Complete All As Specified And Directed. 66 S&F In Repairs Vitreous China Half Stall Urinal Complete Including Providing And Fixing Plugs, Bedding Urinal Against Wall In Cement Mortar 1:2, Securing Urinal To Plugs With And Including 60 Mm Long Brass Screws, Pointing Around Urinal Back In Cement Complete All As Specified And Directed. 67 S&F In Repairs Bevelled Edge Looking Mirror Of Selected Quality Glass, 5.5 Mm Thick Of Size 450 X 600 Mm, Pvc Moulded Case Mounting On 6 Mm Thick Ac Building Board Or Commercial Ply Wood On Back And Fixed To Wooden Plugs With Chromium Plated Brass Screws And Cup Washers, Complete All As Specified And Directed 68 S & F In Repairs Towel Rail 600 Mm Longand 20 Mm Dia Brass Chromium Plated D Typefixed With Screws And Wooden Or Plastic Cleatscomplete All As Specified And Directed. 69 S&F In Repair Pillar Taps, Brass, With Capston Heads, Fancytype, Chromium Plated, Screwed Down High Pressure With Or Without Lettered Hot Or Cold With Long Screwed Shanks And Flynuts Screwed For 15Mm Bore Iron Pipe Andfixed , Complete All As Specified And Directed. 70 S& F In Repairs 32Mm Dia Pvc Waste Pipe For Wash Hand Basin And Kitchen Sink Of Length 900Mm Long With Ptmt Nuts Complete All As Specified And Directed.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 30-Sep-2023 Changes in BOQ BOQ 14-10-2023
2 14-Oct-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 21-10-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 20000.0 /-
Tender Value
INR 10 Lakhs /-

BOQ Items

Name of Work:REPAIR TO SEPTIC TANKS, SOAKAGE WELLS AND MISC SEWAGE WORKS AT RMS CHAIL UNDER GE(I) JUTOGH.
Sl. No. Item Description
1Dismantling of 100mm cast iron or reinforced concrete drain pipe, jointed in cement mortar and taking out of trenches/ floor/ wall if required complete all as specified and directed.
2S&F for 100 mm bore cast iron (sand cast pipe) soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to wall complete all as specified and directed.
3Cleaning the septic tank/sludge chamber of any depth/area/condition incl taking outstagnated sludge or any other material mixed with the sludge etcdeposited in the septic tanks, filling in closed container and depositing in excavated pit, covering the pit at least 500m beyond nearby living accn or area as marked by station controlling authority with earth after depositing sludge, sprinkling fresh lime on covered pit and around septic tanks/ soakage wells to make it hygenic complete all as specified and directed. Note:- (i) Cost of pumping with mechanical sewage pump, excavation of earth pit and fresh lime shall be deemed to include in the rate quoted. (ii) Charges of covered container incl its transportation shall be deemed to include in the rate quoted. (iii) Depth of liquid sludge in the septic tank will be determined and recorded before commencement of work by any Engg conventional method in the presence of Engr-in charge and Contractor.
4Comprehenshive maintenance and cleaning of sewage system including sewage lines, manholes, soakage wells/soak-pits, gully traps, septic tanks attending bloakages in WCs/ WHBs/Drains etc by employing necessary resources including T&P atRMS Chail complete all as specified and directed. The location/ building/complex where work is to be carried out consist of the following:- (a) All OTM and Md Accn atRMS Chail . NOTES:- (i) The Contractor will employe a Supervisor. The Supervisor so employed shall report to the concerned JE daily to give feed back and also to receive day to day sewage Complaints and necessary instructions for smooth running of the contract. (ii) He will carry out normal maintenance to sewage system as required at site. (iii) For any default/delay in attending the complaints recovery shall be effected as per contract conditions provided here-in-after. (iv) T & P as requiered for the work shall be arranged by the contractor without any extra cost to the deptt. (v) Supervisor engaged by the contractor shall take all necessary preventative safety measures and adequate precautions to avoid any health hazard and department shall not be held responsible for any unwanted incidence.
5Cleaning of SGSW/CIpipe lines laid in trenches or fixed to wall/ floor incl desilting /desludging intermediate manholes of any size and depth, removing sludge outside of MoD land in a covered container,atleast 500 m beyond nearby living accn, depositing the sludge in a excavated pit, covering the pit with earth after depositing sludge, sprinkling fresh lime over the pit and around manholes complete all as specified and directed. Note : Charges of covered container incl its transportation charges, cost of fresh lime and earth pit shall be deemed to include in the rate quoted.
6100mm internal dia of pipe line, complete all as specified and directed.
7150mm internal dia of pipe line, complete all as specified and directed.
8M&L for Cleaning/Removal of blockage of floor traps/Nahani Traps of 75mm/100mm bore in kitchn/ Bathrooms/Toilets etc up to 1st Manhole including of taking down PVC/Stainless trap grating and refixing the same with white cement with pigment to match the surfsce as before or any other associated/related complaints not mentioned under this item and will be done as complete all as specified and directed. Note:- The traps shall be measured more than one times as per requirement and directed by Engr-in-charge.
9M&L for Cleaning/Removal of blockage of Gully trapsup to 1st Manhole of any size and any depth including Removing RCC Manhole covers and refixing the same as beforeany other associated/related complaints not mentioned under this item and will be done as directed by Engr-in-charge.Note:- The Gullytraps shall be measured more than one times as per requirement and directed by Engr-in-charge.
10M&L for Cleaning/Removal of blockage of Orissa Pattern WC "P"/S trap and making fuctional up to 1st Manhole or any other associated/related complaints not mentioned under this item and will be done as directed by Engr-in-charge. Note:- The WCshall be measured more than one times as per requirement and directed by Engr-in-charge.
11M&L for Cleaning/Removal of blockage of Europian Pattern WC "P"/S trap and making fuctional up to 1st Manhole or any other associated/related complaints not mentioned under this item and will be done as directed by Engr-in-charge. Note:- The EWCshall be measured more than one times as per requirement and directed by Engr-in-charge.
12M&L for Cleaning/Removal of blockage of Europian Pattern WC "P"/S trap and including removing EWC and cleaning the traps completely and making functional and refitting the EWC in same position including making good the disturbed surfaces with white cement and pigment to match the existing surface or any any other associated/related complaints not mentioned under this item and will be done as directed by Engr-in-charge. Note:- The EWCshall be measured more than one times as per requirement and directed by Engr-in-charge.
13Excavation in trenchesin hard/densesoil n. exc 1.5m wide and n. exc 1.50m deep and getting out complete all as specified and directed.
14Demolition and breaking up 150mm dia drain pipes (salt glazed ware, AC) set in cement mortar complete all as specified and directed.
15M&L for PCC 1:4:8,type D-2, using40mm graded crushed stone aggregate as in concrete bed todrain pipes laid in trenches in any depth incl packing under & haunchingagainst the side of 150mm bore (SGWAC) pipe with concrete after the pipesare laid and testedcompelete all as specified and directed.
16S&F 150mm dia salt glazed stone ware drain pipe and jointed complete all as specified and directed.
17Returning filling in andincluding spreading, leveling and well ramming n.exc 25 cm thick inhard and dense soil complete all as specified and directed.
18Removing excavated materials n.exc 50 m and depositing where diretected at a level n.exc 1.5 m above the starting point in soil complete all as specified and directed.
19Demolition of brickmasonry /stone masonry built in cement mortar including all quious, pillars arches etc complete all as specified and directed.
20Demolition of Cement concrete (Unreinforced) of any description in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
21M&L for PCC1:5:10, type E-2, using 40mm graded crushed stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
22M&L for walling of random rubble stone masonry uncoursed well bonded, bedded and solidly hearted, built in CM 1:6 complete all as specified and directed.
23All as per item No. 20.00 above but except stone complete all as specified and directed.
24M&L for brick work, with sub class"B" brickstraight or curvedd on plan exc 6m means radius built in cement mortor (1: 6) as in manholes and septic tanks complete all as specified and directed.
25M&L for brick work, with sub class"B" brickstraihgt or curved on plan to any radius in half brick work thick wall built in cement mortor (1: 4) as in manholes and septic tanks complete all as specified and directed.
26M&L for rendering 15mm thick in CM 1:4 on fair faces of brick workorconcrete surfacesfinished & evenand smooth mixed withwater proofing compound complete all as specified and directed. Note : WPC will be measured and paid separately under respective item of BOQ
27Supply only integrated water proofing compound complete all as specified and directed .
28M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in cills,steps,seismic and other similar works plinth course,coping benching, bed plate etc complete all as specified and directed.
29Demolition of reinforcedcement concreteof any description and in position not otherwise specificallyprovided for complete all as specified and directed.
30M&L forPrecast reinforced concrete 1:2:4, type B-1using 20 mm gradedcrushed stone aggregate as incover slabs set in cement concrete 1:4 placed in position over manholes etc including use and waste of necessary formwork complete all as specified and directed. Note :- Reinforcementshall be measured and paid seperately.
31M&L for formwork to the edges of concrete flats, treads, breaks in floors, window cills, concrete railings exc 5cm but n.exc 10cm wide, roughed finished surfaces of concrete complete all as specified and directed.
32S&F mild steel bars 10mm dia and over, cut to length, bent to shape required including crancking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire not less than 0.5mm dia or securing with clips quality confirming to deformed or twisted bars complete all as specified and directed.
33Cutting in to existing manholes forconnecting drain pipes making good to pipe and rendering cutting out existing benches for and forming branch channel (1/2 round or 3/4 section)in cement concrete (1:2:4) type B1 smooth finished and reforming benching as required for 150 mm internal bore pipe complete all as specified and directed.
34S & F bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required, hooks (stay), heavy, for large gates, hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
35S & F in repair PVC (SWR) pipes110 mm bore dia single socketed in any length with rubber ring joints,laid in trenches or in floors complete all as specified and directed.
36S & F in repairPVC (SWR) pipes 75 mm bore dia single socketed in any length with rubber ring joints,laid in trenches or in floors complete all as specified and directed.
37S&F PVC (SWR) bends 75 mm bore of any radius complete all as specified and directed.
38S&F PVC (SWR) bends 110 mm bore of any radius complete all as specified and directed.
39M&L for dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
40S & F Glazed ceremic coloured tiles of size 300 mm x 450 mm x 7 mm thick as in dados, skirting, wall etc set jointed in neat cement slurry and pointed in coloured cement to match the tiles over 15 mm thick rendering in CM 1 : 4 complete all as specified and directed.
41S&F Coloured Non Skid ceramic joint free tiles 7 to 8mm thickarea of each tile exc 0.06 sqm but n exc 0.11 sqm in floors, set and jointed in neat cement slurryand pointed in white cement with pigment to match, laid over and including 15mm thick cement screed bed in cement mortar 1:6 complete all as specified and directed.
42S&F in repairvitreous china wash down water closet pan (pedestal pattern) white (excluding fixing bolts flushing cistern and flush pipe) etc complete all as specified and directed.
43S & F in repair Vitreous China wash basin, white, flat back, size 550x400mm including cutting for and pinning in ends of brackets or erecting standincl pillar tap CP 15 mm bore complete all as specified and directed.
44S&F in repairsVitrous china squatting pan Orissa pattern of size 580x440 mm complete all as specified and directed.
45S&F in repair 10 litres capacity PVC low level valve less symphonic action type flushing cistern white with inlet, ball valve, float and handle including brackets and flushing pipe etc complete all as specified and directed.
46M&L for 75mm bore dia cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete 1:2:4 type B-1complete all as specified and directed.
47S&F in repair 15mm dia bib taps, cast copper alloy,chromium plated with crutch orbutterfly handle, screwed down, screwed for iron pipe or for brass ferrulecomplete all as specified and directed.
48S & F in repair 15 mm bore chromium plated stop valve, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
49M&L for PCC 1:3:6, type C-2, using 40mm graded crushed stone aggregate as in surface channel and drains complete all as specified and directed.
50M&L for forming fair finished drain or channel 60cm inner girth in cement concrete, using extra cement including forms moulds, mitred/stopped ends etc complete all as specified and directed.
51S & F in repair ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed in repairs15 mm bore complete all as specified and directed.
52Demolition of cement concrete as in sunken portion and pavings exc 15 cm thicknessabove ground floors complete all as specified and directed.
53M&L for PCC 1:5:10,type E-2, using 40mm graded brick aggregate as in sunkenflooring complete all as specified and directed.
54M&L for rendering/ screed bed 15mm thick in CM 1:3 in (Sunken slab) mixed with water proofing compound as per manufacturer instruction"s surface shall be finished even and smooth without extra cement complete all as specified and directed. Note: Water proofing compound shall be measured and paid separately.
55M&L for priming surfaces and applying heavy treatment (for severe conditions), using glass fibre base bitumen felt, grade 2, complete all as specified and directed.
56Taking down GI Tubing 15 mm dia and connection including cleaning for refixing or removal to store complete all as specified and directed.
57Taking down GI Tubing 20 mm dia and connection including cleaning for refixing or removal to store complete all as specified and directed.
58S&F GI tubing 15 mm bore fixed to wall/ ceiling or floorcomplete all as specified and directed.
59S&F GI tubing 20 mm bore fixed to wall/ ceiling or floorcomplete all as specified and directed.
60Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc. Exc 250 but n exc 500 litres complete all as specified and directed.
61Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc. exc 500 but n exc 1000 litres complete all as specified and directed.
62Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc. exc 1000 but n exc 2000 litres complete all as specified and directed.
63S&F PVC connection 450 mm long suitable for 15 mm bore pipe including PTMT nuts complete all as specified and directed.
64S&F PVC connection 900 mm long suitable for 15 mm bore pipe including PTMT nuts complete all as specified and directed.
65S&F chromium plated grating 125 mm dia circular of approved make and fixing with cement mortar 1:3 on Nahani trap or floor trap complete all as specified and directed.
66S&F in repairs Vitreous China Half stall urinal complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement complete all as specified and directed.
67S&F in repairs bevelled edge looking mirror of selected quality glass, 5.5 mm thick of size 450 x 600 mm,PVC moulded case mounting on 6 mm thick AC building board or commercial ply wood on back and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and directed
68S & F in repairs Towel rail 600 mm longand 20 mm dia brass chromium plated D typefixed with screws and wooden or plastic cleatscomplete all as specified and directed.
69S&F in repair pillar taps, brass, with capston heads, fancytype, chromium plated, screwed down high pressure with or without lettered "Hot" or "cold" with long screwed shanks and flynuts screwed for 15mm bore iron pipe andfixed , complete all as specified and directed.
70S& F in repairs 32mm dia PVC waste pipe for wash hand basin and kitchen sink of length 900mm long with PTMT nuts complete all as specified and directed.