| 1 | Renovation of existing toilet |
| 2 | Removing doors, windows and clerestory window shutters steel or woodincluding stacking within 50 metres lead |
| 3 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineerincharge. |
| 4 | Dismantling false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer in charge. |
| 5 | Dismantling tile work in floors and roofs laid in cement mortar includingstacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm as specified. |
| 6 | Removing urinal pans or wash hand basin with frame including disconnecting the sanitary and water supply connection, removing the same carefully and stacking the serviceable materials as and where directed including throwing the unserviceable materials outside etccomplete |
| 7 | Removing W.C. pans including disconnecting the sanitary and water supply connection, removing the same carefully and stacking the serviceable materials as and where directed including throwing the unserviceable materials outside etccomplete |
| 8 | Demolishing cement motor brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer in charge. |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floorsroofs landingsbalconies and access platform |
| 10 | Providing and laying of Concrete of M20 grade with minimum cement content of 270 kg /cum in position ready mixed or site batched design mix cement concrete for plain cement concrete workusing coarse aggregate and fine aggregate derived fromnatural sourcesPortland Pozzolana/Ordinary PortlandPortland Slag cement, admixtures in recommended proportions as per IS:9103 to accelerate retard setting of concreteto improve durability and workability without impairing strengthincluding pumping of concrete to site of laying curing, carriage for all leadsbut excluding the cost of centeringshuttering and finishingas per direction of the engineer in charge Note: Extra cement up to 10 of the minimum specified cementcontent in design mix shall be payable separately. In case the cement content in design mix is more than 110of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. |
| 11 | Steel reinforcement with Mild steel and Medium Tensile steel bars for R.C.C. work including straightening, cuttingbending, placing in position and binding all complete above plinth level. |
| 12 | Supplying and fixing in positionP.V.C. SOILWASTE PIPEof following sizes having ISI mark and providing leak proof joints including fixing to walls with Specials PVC /MS. clamps etc., and making connection to the all sanitary fittings,dismantling the brick masonry/RCC floor or roof slab and redoing the dismantled portion to original condition etc., complete complying with standard specification The PVC pipe should be got approved by the Executive Engineer before use on works110 mm dia PVC Pipe |
| 13 | Supplying and fixing in positionP.V.C. SOILWASTE PIPEof following sizes having ISI mark and providing leak proof joints including fixing to walls with Specials PVC /MS. clamps etc., and making connection to the all sanitary fittings,dismantling the brick masonry/RCC floor or roof slab and redoing the dismantled portion to original condition etc., complete complying with standard specification The PVC pipe should be got approved by the Executive Engineer before use on works75mm dia PVC Pipe |
| 14 | Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re doing the dismantled portion to original condition etc., complete complying with standard specifications. The PVC specials should be got approved by the Executive Engineer before use on worksUPVC 110mm dia bend |
| 15 | Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re doing the dismantled portion to original condition etc., complete complying with standard specifications. The PVC specials should be got approved by the Executive Engineer before use on worksUPVC 110mm dia T Joint |
| 16 | Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re doing the dismantled portion to original condition etc., complete complying with standard specifications. The PVC specials should be got approved by the Executive Engineer before use on worksUPVC 75mm dia Bend |
| 17 | Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re doing the dismantled portion to original condition etc., complete complying with standard specifications. The PVC specials should be got approved by the Executive Engineer before use on worksUPVC 75mm dia T Joint |
| 18 | Supplying laying and jointing CPVC pipesbest variety conforming to ISS including fixing CPVC specials and fixing to wall in concealed manner,making holes on the wall or drilling holes in roof etc and making good of the dismantled portions etc.complete under concealed internal water supply arrangements32mm dia CPVC pipe |
| 19 | Supplying laying and jointing CPVC pipesbest variety conforming to ISS including fixing CPVC specials and fixing to wall in concealed manner,making holes on the wall or drilling holes in roof etc and making good of the dismantled portions etc.complete under concealed internal water supply arrangements 20mm dia CPVC pipe |
| 20 | Supply and fixing 25mm diaGun metal gate valve Heavy Dutyof approved qualityISIand brand including cost and conveyance of all materials complying with standard specification. Parryware or equivalent make |
| 21 | Supplying and fixing 15mm CP 2 way bibcock with Health Faucet of 1.20m length of approved make. Parryware or equivalentas per standard specifications |
| 22 | Supply and fixing 25mm diaGun metal gate valve Heavy Duty of approved quality ISI and brand including cost and conveyance of all materials complying with standard specification. Parryware or equivalent make |
| 23 | Supplying and fixing colour American Standards - Signature WH toilet Bowlor equivalent European water closetwall hung or wallvit typewith built in porcelain flushing cistern of dual flush type6 Lit/3Litof compacted size of wallvit pal type 540mmx360mmx410mm orwall hung size of cardiff model 660x365x770 mm and seat cover matching the closet of approved quality .The rate is including cost of all other fittings are gold plated such as 15mm angle cock 1 NoJaguar Queens or Equivalent 15mmx600mm nylon connection1 NoJaquar or Equivalent |
| 24 | Supplying and fixing in position best quality American Standardunder counter basin Activa of size 422X600x290 mm and Bauflow Pillar Tape including fixing the wash hand basin in the Counter in position with a pair of C.I.brackets with teak wood plugs and screws andgiving necessary water supply connection and painting the brackets with two coats of paint over a primingcoat of anticorrosive paint including testing forleackage etc.,complete complying with standard specifications the wash hand basins and specials should be got approved by the Executive Engineer before use on works |
| 25 | Supplying and fixing in bewelled edge mirror of approved quality and brand of size 900X1350mm with necessary 8 mm water proof plywood colour with bottom stand of approved colour with brass screws,rawal plugs etc complete complyingwith standard specificationsThe mirror should be got approved by Engineer before use on works. |
| 26 | Supply and run of 2 of 2.5 sq.mm. 220.3 PVC insulated single core unsheathed copper conductor of 1100V grade in rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour SD 55 |
| 27 | Wiring with 2 x 1.5 sq.mm. 220.3 PVC insulated single core unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wallwith modular MS switch box base frame and covering plate and 6A FT modular switch and making good of the concealed portion with suitable colour for PVC concealed light/fan point. |
| 28 | Supplying and fixing of best approved quality Spotlight 9Wof ledlam Model noLLF127B or Equalent complete complying with standard specification. |
| 29 | Supplying and fixing best approved quality Suspended Light complete complying with standard specification. |
| 30 | Paving the floor with anti skid ceramic tilescolour and shade as directedof size 1200 mm x 600mm x 10 mm in all floors over a base layer of cement mortar 1:3 one cement and three sand20mm thick laid in situ and pointed with same coloured cementetc |
| 31 | Dadooing the walls with Vitrified tiles in the bathroom wall of size 1200mm x 600mm x 10mm of approved make and sample in pattern as per detailed drawings on up to 25mm thick bed of cement mortar 1:2 including surface preparation, neat cement float giving necessary slopes cleaning joints and grouting them in neat white cement paste with pigmented additives to match shade of the tileetc complete. With Spacers of 4mm filled with Laticrete Epoxy Grout |
| 32 | Laying the counter top with granite (colour and shade as directed) a base layer of cement mortar 1:3one cement and three sand 20mm thick laid in-situ and pointed with same coloured cementetc |
| 33 | Providing and fixing of false ceiling of Aluminium Corrugated Plain Wood finish Linear Ceilingsof Module size 135mm (FACE ) x 10mmdepthand 15mm Groove madeout of 0.6mm thick Aluminum Alloy sheet finished with approved Wood Gram finish The panels are installed interlocking to one another using a 0 5mm thick Galvanised steel carrier powder coated to approved RAL colour finish. The Corrugated Aluminium Linear Ceilings are Suspended using RIGID SUSPENSION made of Powder coated 1 5mm Thick MULTI SLOTTED Gl L profile as Vertical. Primary horizontal and Secondary Horizontal member to which the ceiling carrier is mechanically fastened, the Vertical section is anchored to the true ceiling using certified anchor fastener 8mm. Price quoted to include Panel to panel Joint splices end termination profile etc as per specification given by the architect and as directed by Engineer in Charge |
| 34 | Providing and fixing toilor-made doors and partitions for restrooms. To enhance the exquisiteness, all doors are 12mm thick and their stainless steel hardware fittings make these cubicles highly durable and long lasting as per specification given by the architect and as directed Engineer incharge |
| 35 | Supplying, fabrication and fixing of 30mm thick both side pre laminated WPC door shutter with frame of required size 1.00m x 2.30m& 1.00 x 2.30m using 75mm x 50mm size WPC frame as allround frame with necessary brass furniture fittings such as 125mm x 25mmbrass hinges-3Nos200mm x 12mmbrass tower bolt1No, 150mm x 12mm brass tower bolt 2Nos,150mm brass handle2Nos T.W lippings around the shutter etcincluding cost and conveyance of all materials complying with standard specification. |
| 36 | Providing and fixing factory made uPVC white colour fixed glazed windows/ ventilators comprising of uPVC multi chambered frame and mullionwhere ever required extruded profiles duly reinforced with 1.600.2 mm thick galvanized mild steel section made from roll forming process of required lengthshape & size according to uPVC profile uPVC extruded glazing beads of appropriate dimension, EPDM gasketG.I fasteners 100 x 8 mm size for fixing frame to finished wall plastic packersplastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all cornersmullionif requiredshall be also fusion welded including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved qualityall complete as per approved drawing & direction of Enginee rin Charge. Singledouble glass panes and silicon sealant shall be paid separately . Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |