}

Tender For Supply, Installation, Testing And Commissioning Of Split Air Conditioners At Various Locations Of Rcc, Thiruvananthapuram-Kerala

Regional Cancer Center -RCC has published Tender For Supply, Installation, Testing And Commissioning Of Split Air Conditioners At Various Locations Of Rcc. Submission Date for this Tender is 07-10-2023. Rotary Compressor Tenders in Thiruvananthapuram Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

39831033
Tender For Supply, Installation, Testing And Commissioning Of Split Air Conditioners At Various Locations Of Rcc
Open Tender
Indian
Kerala
Thiruvananthapuram
07-10-2023

Tender Details

Supply, Installation, Testing And Commissioning Of Split Air Conditioners At Various Locations Of Rcc , Sitc Of Split Air Conditioners , Supply, Installation, Testing And Commissioning Of Following Capacity Inverter Type Wall Mounted Split Ac Unit Having Minimum 03 Star Rating Of Bee Complete With Indoor Unit ( Idu ) , Outdoor Unit ( Odu ) , Surface / Concealed Copper Refrigerant Piping With 13 Mm Thick Nitrile Thermal Insulation Up To 3 Mtr. ( Idu To Odu ) , Frls Power And Control Cables Of Copper Conductor Of Suitable Size Up To 4 Mtr. Length ( Idu To Odu ) , R410a Refrigerant Or Refrigerant With Better Odp / Gwp, Cordless Remote Controller And Suitable For Working With 400 / 230V +10% Of 50 Hz, 1 / 3 Phase Ac Supply. Indoor Unit With Dx Cooling Coil, Rough Filter And Air Outlet With Horzontal And Vertical Automatic Rotating Deflecters. Air Cooled Condensing Unit Complete With Scroll / Rotary Compressor, Axial Type Condenser Fans, Condenser Coil. Unit Shall Meet Relavant Is Standards And The Installations To Be Carried Out As Per Relevant Cpwd Specification And Oem Recommendation. Inverter Type Wall Mounted Split Ac Unit - 02 Tr , Supply, Installation, Testing And Commissioning Of Following Capacity Inverter Type Wall Mounted Split Ac Unit Having Minimum 03 Star Rating Of Bee Complete With Indoor Unit ( Idu ) , Outdoor Unit ( Odu ) , Surface / Concealed Copper Refrigerant Piping With 13 Mm Thick Nitrile Thermal Insulation Up To 3 Mtr. ( Idu To Odu ) , Frls Power And Control Cables Of Copper Conductor Of Suitable Size Up To 4 Mtr. Length ( Idu To Odu ) , R410a Refrigerant Or Refrigerant With Better Odp / Gwp, Cordless Remote Controller And Suitable For Working With 400 / 230V +10% Of 50 Hz, 1 / 3 Phase Ac Supply. Indoor Unit With Dx Cooling Coil, Rough Filter And Air Outlet With Horzontal And Vertical Automatic Rotating Deflecters. Air Cooled Condensing Unit Complete With Scroll / Rotary Compressor, Axial Type Condenser Fans, Condenser Coil. Unit Shall Meet Relavant Is Standards And The Installations To Be Carried Out As Per Relevant Cpwd Specification And Oem Recommendation. Inverter Type Wall Mounted Split Ac Unit 1.5 Tr , Supply, Installation, Testing And Commissioning Of Following Capacity Inverter Type Wall Mounted Split Ac Unit Having Minimum 03 Star Rating Of Bee Complete With Indoor Unit ( Idu ) , Outdoor Unit ( Odu ) , Surface / Concealed Copper Refrigerant Piping With 13 Mm Thick Nitrile Thermal Insulation Up To 3 Mtr. ( Idu To Odu ) , Frls Power And Control Cables Of Copper Conductor Of Suitable Size Up To 4 Mtr. Length ( Idu To Odu ) , R410a Refrigerant Or Refrigerant With Better Odp / Gwp, Cordless Remote Controller And Suitable For Working With 400 / 230V +10% Of 50 Hz, 1 / 3 Phase Ac Supply. Indoor Unit With Dx Cooling Coil, Rough Filter And Air Outlet With Horzontal And Vertical Automatic Rotating Deflecters. Air Cooled Condensing Unit Complete With Scroll / Rotary Compressor, Axial Type Condenser Fans, Condenser Coil. Unit Shall Meet Relavant Is Standards And The Installations To Be Carried Out As Per Relevant Cpwd Specification And Oem Recommendation. Inverter Type Wall Mounted Split Ac Unit 1.0 Tr , Sitc Of 2.7 Kva Capacity Voltage Stabilizer For Split Air Conditioners Working With 230V +10%, 50 Hz, Single Phase Phase Ac Supply And All Accessories , Sitc Of 3.35 Kva Capacity Voltage Stabilizer For Split Air Conditioners Working With 230V +10%, 50 Hz, Single Phase Phase Ac Supply And All Accessories , Supply And Fixing Of Ms Powder Coated / Gi Painted Odu Stand For Split Air Conditioners With All Accessories , Sitc Of Extra 40 Mm Dia Pvc Drainline With Thermal Insulation After 4 Mtr , Sitc Of Extra Copper Piping Connecting Between Odu And Idu With 13 Mm Thick Nitrile Thermal Insulation After 3 Mtr

Key Value

Document Fees
INR 2950 /-
EMD
INR 37500.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Supply, installation, testing and commissioning of split air conditioners at various locations of Regional Cancer Centre, Thiruvananthapuram
Sl. No. Item Description
1SITC of Split Air Conditioners
2Supply, installation, testing and commissioning of following capacity inverter type Wall mounted Split AC unit having minimum 03 star rating of BEE complete with indoor unit (IDU), Outdoor unit (ODU), surface /concealed copper refrigerant piping with 13 mm thick nitrile thermal insulation up to 3 Mtr. (IDU to ODU),FRLS Power and control cables of copper conductor of suitable size up to 4 Mtr. length (IDU to ODU), R410A refrigerant or refrigerant with better ODP/GWP, Cordless remote controller and suitable for working with 400/230V +10% of 50 Hz, 1/3 phase AC supply. Indoor unit with DX cooling coil, rough filter and air outlet with horzontal and vertical automatic rotating deflecters. Air cooled condensing unit complete with Scroll / Rotary compressor, axial type condenser fans, condenser coil. Unit shall meet relavant IS standards and the installations to be carried out as per relevant CPWD specification and OEM recommendation. Inverter type Wall mounted Split AC unit - 02 TR
3Supply, installation, testing and commissioning of following capacity inverter type Wall mounted Split AC unit having minimum 03 star rating of BEE complete with indoor unit (IDU), Outdoor unit (ODU), surface /concealed copper refrigerant piping with 13 mm thick nitrile thermal insulation up to 3 Mtr. (IDU to ODU), FRLS Power and control cables of copper conductor of suitable size up to 4 Mtr. length (IDU to ODU), R410A refrigerant or refrigerant with better ODP/GWP, Cordless remote controller and suitable for working with 400/230V +10% of 50 Hz, 1/3 phase AC supply. Indoor unit with DX cooling coil, rough filter and air outlet with horzontal and vertical automatic rotating deflecters. Air cooled condensing unit complete with Scroll / Rotary compressor, axial type condenser fans, condenser coil. Unit shall meet relavant IS standards and the installations to be carried out as per relevant CPWD specification and OEM recommendation. Inverter type Wall mounted Split AC unit 1.5 TR
4Supply, installation, testing and commissioning of following capacity inverter type Wall mounted Split AC unit having minimum 03 star rating of BEE complete with indoor unit (IDU), Outdoor unit (ODU), surface /concealed copper refrigerant piping with 13 mm thick nitrile thermal insulation up to 3 Mtr. (IDU to ODU), FRLS Power and control cables of copper conductor of suitable size up to 4 Mtr. length (IDU to ODU),R410A refrigerant or refrigerant with better ODP/GWP, Cordless remote controller and suitable for working with 400/230V +10% of 50 Hz, 1/3 phase AC supply. Indoor unit with DX cooling coil, rough filter and air outlet with horzontal and vertical automatic rotating deflecters. Air cooled condensing unit complete with Scroll / Rotary compressor, axial type condenser fans, condenser coil. Unit shall meet relavant IS standards and the installations to be carried out as per relevant CPWD specification and OEM recommendation. Inverter type Wall mounted Split AC unit 1.0 TR
5SITC of 2.7 KVA capacity voltage stabilizer for split air conditioners working with 230V +10%, 50 Hz, single phase phase AC supply and all accessories
6SITC of 3.35 KVA capacity voltage stabilizer for split air conditioners working with 230V +10%, 50 Hz, single phase phase AC supply and all accessories
7Supply and fixing of MS powder coated/GI painted ODU stand for split Air conditioners with all accessories
8SITC of extra 40 mm dia PVC drainline with thermal insulation after 4 Mtr
9SITC of extra copper piping connecting between ODU and IDU with 13 mm thick nitrile thermal insulation after 3 Mtr
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail