Tender For Provide And Fixing 16 Mtr High Mast Light At Various Places In Municipal Area Parbatsar, Nagaur-Rajasthan

Department Of Local Bodies has published Tender For Provide And Fixing 16 Mtr High Mast Light At Various Places In Municipal Area Parbatsar. Submission Date for this Tender is 02-10-2023. Electrical Maintenance Tenders in Nagaur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

39830581
Tender For Provide And Fixing 16 Mtr High Mast Light At Various Places In Municipal Area Parbatsar
Open Tender
Indian
Rajasthan
Nagaur
02-10-2023

Tender Details

Provide And Fixing 16 Mtr High Mast Light At Various Places In Municipal Area Parbatsar , Supply Installation Testing & Commissioning Of Iso Certified Company Made High Mast Lighting System (As Per Plg 07 Of Ilp Uk Techinical Report No 7 Of Ile Uk /Is:875 Part-1 –2015//Bsen10025/And Is:2062 )Consisting Of Totally Hot Dip Galvanised By Single Dipped Method High Mast, Lantern Carriage Suitable For Up To 12 Nos Luminaries With Welded Arm (Excluding Luminares), Mast Head Frame Assembly With Full Cover, Including 1No. Led 15 Watts Aviation Obstruction Lights, Double Drum Type Self Sustaining Winch, Integral Power Tool Accesible From Door With Padlocking Arrangement ( Winch Motor With Control Circuit) Hot Dipped Galvanised Heavy Duty Pipe Lightening Finial, S.S. Ropes (Aisi 316, 7 / 19 Costruction ), Epr Insulated Pcp Sheathed Trailing Cable, Including Outdoor Type Control Panel For Auto On / Off, Reverse /Forward Motor Operation And Cc Foundation Of M - 25 Grade Complete As Required As Per Is 456/Is 2911. The Mast Is Constructed From Mild Steel Plates (As Per Is 5986 Gr. 510 ) Cut And Folded To Form A Polygonal Section, Telescopic Jointed And Welding Asper Bs 5135. ( See Table P - 03 For Specs.) Oem Must Have Type Test Certificate For Wind Tunnel Test For High Mast Fixtures. Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/Work , Refer Annexure A Attached With This Bsr . 16 Mtr. Hm (In 2 Section) , Plate Earthing As Per Pwd Specification For Electrical Works As Per Is:3043 With Hot Dipped G.I. Earth Plate Of Size 600Mm X 600Mm X6.0M M By Embodying 3 To 4 Mtr. Below The Ground Level With 20 Mm Dia. G.I. B Class Watering Pipe ,Including All Accessories Like Nut, Bolts, Reducer, Nipple, Wire Meshed Funnel, And Heavy Duty Weather Proof Poly-Propylene Earth Pit Chamber With Lockable Jam Free Lid Suitable For Safe Working Load 5000 Kg Or More Of Size Top Dia. 225 To 260 Mm, Bottom Dia 300 To 350 Mm. And Height 250 To 300 Mm. And Embodying The Pipe Complete With Alternate Layers Salt And Coke/ Charcoal, Testing Of Earth Resistance For Value Of 5 Ohms Or Less As Required & Must Record By Engineer In Charge During Site Visit And Ensure To Enter In Measurment Book. All As Perp Re Approved By Engineer In Charge. For Additional Technicalparameters Of Products/ Work , Refer Annexure A Attached With This Bsr . , Providing & Fixing Of Ik07 Ip-66 Protected High Power Led Flood Light System With Pressure Diecast Aluminium Housing Lm6/ Adc12 Material , Toughened Glass Diffuser With Suitable Lenses On Led To Achieve Various Beam Angles, 240 Volt, 50Hz, Of High Power Led Lamps . Integrated Driver Must Be Potted & Has A Unique Bis R Number Shall Be High Efficiency Having Efficiency More Than 85 % And In Compliance To Bis Certified And T.C. Certificate. The System Level Luminaire Efficacy >=120 Lm/ Wt With High Power Leds Is To Be Used . Led Driver Input Voltage Ac 120 To 270 V Ac With High Voltage Cutoff @>=300 V Ac And Auto Resetting Safety . Input Frequency 50Hz±3%, Power Factor >0.95 ,Driver Efficiency >85% , Thd(I) <10% , Driver Current <1000Ma Shown In Lm79 Report. Driver Should Be Phase To Phase Protection Of 440 V For 4 Hrs. Electrical Connector Must Be Provided, Surge Protection Min >=4Kv Internaland 10Kv External, System Life Of 30000 Burning Hours With 70% Ofinitial Lumens Maintained, Color Rendering Index >70 And Cct 5700K ±355K. Driver Current <1000Ma Shown In Lm79 Report. Manufactures Word Mark/Name Engraved/Embossing/Screen Printing On Die Cast Housing To Allow Traceability/Authenticity. Fixture Shall Be Is 10322 Complianced.Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79/Lm80) Certificate/ Report With Liable Warranty Of Product/Accessories From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr .High Power Led Flood Light 240W , P & F Of Ip 55 Protected Light Controlled Switch Based On Infrared Sensing And Daylight With Built In Over Load Protection, Timer To Switch Off At Preselected Time. Switch Shall Have 7 Day Power Backup Without Hampering Of Preset Time And Over Ride Facility For Maintenance Purpose (A) Suitable For 15 Kw Load (Three Phase) Including Contactor, Mcb, Cable Glands, Terminal Block And Locking Arrangement , Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Unarmoured / Armoured Aluminium Cable Of 1.1 Kv Grade As Per Pwd Specification For Electrical Works In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/Cable Trench With Filling Of Excavated Earth In Trench , On Existing Cable Trays Or On Surface Etc. Including Making Necessary Connection, Testing Etc. As Required Of Size And As Per Points (A), (B), (C), Mentioned Below:- (A) Material :- H4- Grade Aluminium Conductor Of Purity >99.6 % & As Per Is:1554 P-I / Is :7098 P – I (B) Conductor Shall Have Electrolytic Aluminium Confirming To Is 8130, Is 3975-1999 For Armouring Of Cables In Armoured Cable Items , Is 5831 For Sheath, Is 10810 (Part 0 To 64 ) For Testing Procedures. (C) Oem Must Have Iso 9001 & 14001 Certifications For Quality Assuarance & Its Own In House Nabl Lab Setup For All Testing Facilities For Cables . Appropriate Type Test Certificate / Oem Test Report Shall Be Submitted . All Above As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr. 16 Sq. Mm 4 Core , Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A Or C ,Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping Including All As Per Pre Approved By Engineer In Charge,Making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr .2 X 2.5 Sq.Mm

Key Value

Document Fees
INR 1000 /-
EMD
INR 49300.0 /-
Tender Value
INR 24.65 Lakhs /-

BOQ Items

NAME OF WORK : P & F 16 mtrHigh mast light at various places in municipal area parbatsar
Sl. No. Item Description
1Supply installation testing & Commissioning of ISO certified company made high mast lighting system (as per PLG 07 of ILP UK techinical report no 7 of ILE UK /IS:875 Part-1 –2015//BSEN10025/and IS:2062 )consisting of totally hot dip galvanised by single dipped method high mast, lantern carriage suitable for up to 12 nos luminaries with welded arm (excluding luminares), mast head frame assembly with full cover, including 1No. LED 15 Watts aviation obstruction lights, double drum type self sustaining winch, integral power tool accesible from door with padlocking arrangement ( winch motor with control circuit) hot dipped galvanised heavy duty pipe lightening finial, S.S. ropes (AISI 316, 7 / 19 costruction ), EPR insulated PCP sheathed trailing cable, including outdoor type control panel for auto on / off, reverse /forward motor operation and CC foundation of M - 25 grade complete as required as per IS 456/IS 2911. The mast is constructed from mild steel plates (as per IS 5986 Gr. 510 ) cut and folded to form a polygonal section, telescopic jointed and welding asper BS 5135. ( See table P - 03 for specs.) OEM Must have Type test certificate for wind tunnel test for High mast fixtures. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/work , refer Annexure "A" attached with this BSR . 16 Mtr. HM (In 2 section)
2Plate Earthing as per PWD specification for electrical Works as per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x6.0m m by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. "B" class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as perp re approved by Engineer in charge. For additional technicalparameters of products/ work , refer Annexure "A" attached with this BSR .
3Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material , toughened glass diffuser with suitable lenses on LED to achieve various beam angles, 240 volt, 50Hz, of high power LED lamps . Integrated driver must be potted & has a unique BIS R number shall be high efficiency having efficiency more than 85 % and in compliance to BIS certified and T.C. certificate. The System level Luminaire efficacy >=120 lm/ wt with High Power LEDs is to be used . LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety . Input Frequency 50Hz±3%, Power Factor >0.95 ,driver Efficiency >85% , THD(I) <10% , driver current <1000mA shown in LM79 report. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector Must be provided, Surge Protection Min >=4KV internaland 10KV external, System life of 30000 Burning hours with 70% ofInitial Lumens maintained, color Rendering Index >70 and CCT 5700K ±355K. Driver current <1000mA shown in LM79 report. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .High power LED Flood light 240w
4P & F of IP 55 protected light controlled switch based on infrared sensing and daylight with built in over load protection, timer to switch OFF at preselected time. Switch shall have 7 day power backup without hampering of preset time and over ride facility for maintenance purpose (a) Suitable for 15 kw load (Three Phase) including contactor, MCB, cable glands, terminal block and locking arrangement
5Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Unarmoured / Armoured aluminium cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:- (a) Material :- H4- Grade aluminium conductor of purity >99.6 % & as per IS:1554 P-I / IS :7098 P – I (b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999 for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures. (c) OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities for cables . Appropriate type test certificate / OEM test report shall be submitted . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR. 16 sq. mm 4 core
6Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228 for lower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type A or C ,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4, , in existing surface or recessed PVC/ MS conduit/casing capping including all as per pre approved by Engineer in charge,making connections, etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .2 x 2.5 sq.mm
Disclaimer :