Tender For Construction Of 03 Nos Surveillance Cum Op Shelter (G+1) At Bop Laijuri-02 Nos And Bop Lailong-01 Nos In Aor Of 172 Bn Bsf Under Shq Bsf Jowai (Sh. Pvdg Iei, Fans And Service Connection And Off Grid Solar Plant), East Jaintia Hills-Meghalaya

Border Security Force-BSF has published Tender For Construction Of 03 Nos Surveillance Cum Op Shelter (G+1) At Bop Laijuri-02 Nos And Bop Lailong-01 Nos In Aor Of 172 Bn Bsf Under Shq Bsf Jowai (Sh. Pvdg Iei, Fans And Service Connection And Off Grid Solar Plant). Submission Date for this Tender is 03-10-2023. PEB Tenders in East Jaintia Hills Meghalaya. Bidders can get complete Tender details and download the document.




Tender Notice

39808736
Tender For Construction Of 03 Nos Surveillance Cum Op Shelter (G+1) At Bop Laijuri-02 Nos And Bop Lailong-01 Nos In Aor Of 172 Bn Bsf Under Shq Bsf Jowai (Sh. Pvdg Iei, Fans And Service Connection And Off Grid Solar Plant)
Open Tender
Indian
Meghalaya
East Jaintia Hills
03-10-2023

Tender Details

Construction Of 03 Nos Surveillance Cum Op Shelter ( G+1 ) At Bop Laijuri-02 Nos And Bop Lailong-01 Nos In Aor Of 172 Bn Bsf Under Shq Bsf Jowai ( Sh. Pvdg Iei, Fans And Service Connection And Off Grid Solar Plant ) ; 1 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. ( Group-A ) 2 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With Thesize 2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required. 3 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 3 Pin 5 / 6 A Modular Socket Outlet And 5 / 6 A Modular Switch, Connections Etc. As Required. 4 Providing And Fixing Of Prewired 20 / 22 Watt Box Type Led Batten Having 6000K / 4000K Cct, Extruded Thermoplastic Body With Pc Diffuser In Unique Square Shape & 240 Degree Wide Distribution Directly On Ceiling / Wall, Including Connection With 1.5 Sq. Mm Fr Pvc Insulated, Copper Conductor, Single Core Cable And Earthing Completeas Required.Make- Havells / Phillips / Crompton / Panasonic / Bajajetc.As Per Direction Of Engineer-In-Charge. 5 Supply, Installation, Testing And Commissioning Of Energy Saving Ceiling Fan Having Specification :- Size-1200Mm, Air Delivery - 220 Mm3, Colour- Ivoury Including Wiring The Down Rods Of Standardlength ( Upto 30 Cm ) With 1.5 Sq. Mm Fr Pvc Insulated, Copper Conductor, Single Core Cable Etc. As Required.Make -Usha / Havells / Crompton 6 Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 7 Sitc Of Exhaust Fan 250 Mm Sweep Inbuilt With Decorative Plastic Body With Shutter Complete Set In The Exisiting Opening Including Connections Etc As Required.Make-Havells 8 Supplying And Fixing Of 5 Watt , Four Module Led Foot Light Made Up Of Polycarbonate Material , Pcb Material, Having Low Power Consumption With Soft White Glow Lumen Outputi / C Connection Complete As Required.Make - Crompton / Havells / Phillips 9 Providing And Fixing Of Prewired 6 / 8 Watt Circular / Square Surface Mounted Led Panel With Premium Diffuser To Ensure Glare Free & Even Light Distribution Having 6000K / 4000K Cct, Directly On Ceiling / Wall, Including Connection With 1.5 Sq. Mm Fr Pvc Insulated, Copper Conductor, Single Core Cable And Earthing Completeas Required As Per Direction Of Engineer-In-Charge.Make- Havells / Phillips / Crompton 10 Providing And Fixing Of Prewired 5 Watt Led Batten Mirror Light With 100 Lumens Per Watt , 1 Feet Lengthwith Premium Diffuser To Ensure Glare Free & Even Light Distributionhaving 6500K / 6000K Cctdirectly On Ceiling / Wall, Including Connection With 1.5 Sq. Mm Fr Pvc Insulated, Copper Conductor, Single Core Cable And Earthing Completeas Required As Per Direction Of Engineer-In-Charge.Make- Havells / Phillips / Crompton 11 Sitc 45 / 48Watt Led Street Light I / P Voltage 220V Ac, With Suitable Electronic Driver And High Power Led As Light Source, With Secondary Optics Made In Pressure Die Cast Housing With Toughned Glass Ip66 Protection On Existng Gi Pipe Bracket I / C Connection Etc As Required.Make- - Havells / Crompton / Bajaj / Syska 12 P / F Of 40 / 43Mm Dia 1.5Mtr Long Gi Pipe ( Medium Class ) Bracket On The Existing Wall With Suitable Ms Clamp 2Nos And Nut & Bolt For Mounting Of Led Fitting I / C Painting Etc As Required As Per Direction Of Engineer Incharge. 13 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Single Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc As Required. ( Make:Havells / Legrand / Abb / Schenider / Standard ) 14 Supplying And Fixing 8 Way, Double Door, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Testing And Comissioning Etc As Required. 15 Supplying And Fixing 40A, Double Pole 240 V Isolator In The Existing Mcb Db Complete With Connections, Testing And Comissioning Etc As Required. 16 Supplying And Fixing Two Way Centre Off 40A 2P Mcb Changeover Switch In The Existing Mcb Db Complete With Connections , Testing And Comissioning Etc As Required . ( Make-Havells / Legrand / Abb / Schenider / Standard ) 17 Earthing With G.I. Earth Pipe 4.5 Metre Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal / Coke And Salt As Required. 18 Providing And Laying Earth Connection From Earth Electrode With 6 Swg Dia G.I. Wire In 15 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Thimble Excavation And Re-Filling As Required. 19 Earthing With Gi Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc ( With Charcoal / Coke As Salt ) As Required 20 Providing And Fixing 25 Mm X 5 Mm G.I Strip In 40 Mm Dia G.I. Pipe From Earth Electrode Including Connection With Brass Nut, Bolt, Spring, Washer Excavation And Re-Filling Etc. As Req. 21 Providing And Fixing Of Lightning Conductor Finial, Made Of 25 Mm Dia 300 Mm Long Gi Tube , Having Single Prong On Top, With 85 Mm Dia 6 Mm Thick G.I. Base Plate Including Holes Etc Complete As Required 22 Jointing Copper / G.I. Tape ( With Another Copper / G.I. Tape, Base Of The Finial Or Any Other Metallic Object ) By Reveting / Nut Bolting / Sweating And Soldring Etc As Required 23 Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required ( For Horizontal Run ) 24 Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required ( For Vertical Run ) 25 Providing And Fixing Testing Joint, Made Of 20 Mm X 3 Mm Thick Gi Strip, 125 Mm Long With 4 Nos Of G.I Bolt, Nut Chuck Nuts And Spring Washer Etc Complete As Required. 26 Providing And Laying Gi Tape 32 Mm X 6 Mm From Earth Electrode Directly In Ground As Required 27 Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Size Upto 35 Sqmm Direct In Ground Including Excavation And Refilling The Trench Etc As Required, But Excluding Sand Cushioning And Protective Covering. 28 Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Size Upto 35 Sq. Mm ( Clamped With 1 Mm Thick Saddle ) On Wall Surface / Open As Required 29 Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Upto 35 Sq. Mm Size In The Existing Rcc / Hume / Metal Pipe As Required. 30 Supplying And Fixing Of Light Class G.I. Pipe Of 50 Mm Dia. ( Nominal ) 3 Metres Length Along The Pole For Protection Of Under Ground Cable As Required. 31 Supplying Of Pvc Sheathed / Xlpe Armoured Aluminium Conductor Power Cable Of 1.1 Kv Grade Of 2 X 16 Sqmm Size. ( Make: Polycab / Havells / Finolex ) 32 Supply, Installation, Testing And Commissioning Of1 Kwp Off-Grid Solar Photovoltaic Power Plant Conforming To Mnre Specifications As Amended , Consisting Of Mono / Poly Crystalline Silicon Solarcells, Necessary Protections, Earthing , Floor Mounted On Gi Structure Of Suitable Strength With Following Components Complete As Required:- ( A ) Solar Photovoltaic Module Of Capacity 330Wp Or Above, Manufactured In India, Conforming To Is 14286 / Iec 61215, Is / Iec 61730-Part-1, Is / Iec 61730 Part-2 Solar Photovoltaic Module Conversion Efficiency Shall Not Be Less Than 16.5%. Pv Modules Used In Solar Power Plants / Systems Must Be Warranted For Their Output Peak Watt Capacity, Which Should Not Be Less Than 90% At The End Of 10 Years And 80% At The End Of 25 Years. ( B ) Solar Inverter Suitable For 1 Kwp Solar Panel Inbuilt With Pwm / Mppt Solar Charge Controller , Pure Sine Wave Output, Output Voltage Suitable To Generate Ac Power With Efficiency Not Less Than 97% , Total Harmonic Distortion Less Than 3% ( C ) Fixing Of Array Junction Box & Main Junction Box With Ip 65 Protection And Termination Arrangement For Incoming And Outgoing Ac / Dc Cable Along With Glands, Lugs, Mc4 Connector And Other Accessories Etc. As Required. ( D ) Lightning And Surge Voltage Protection. ( E ) Supplying And Installation Of 2 Nos 150 Ah Solar Batteries. F ) Connections & Interconnections By Supplying & Fixing Required Size Xlpe / Pvc Insulated Copper Conductor 1.1 Kv Grade Armoured Power And Control Cables Between Solar Modules, Solar Inverter Along With Supplying & Fixing Of Necessary Channel / Conduit Lugs And Other Accessories Etc. As Required.Cost For 01 Kwp Off Grid Solar Pv System I / C Providing, Installation, Testing, Commissioning, Transportation, Incurrence, Warranty / Guarantee, Monitoring And Maintenance For 5 ( Five ) Years And Applicable Taxes For 01 Kwp Standalone Solar Power Plants, Panel With 6 Hrs. Battery Backup As Per The Mnre Specification Complete As Required.

Key Value

Document Fees
Refer document
EMD
INR 20175.0 /-
Tender Value
INR 10.08 Lakhs /-

BOQ Items

Name of Work: Construction of 03 Nos Surveillance cum OP Shelter (G+1) at BOP Laijuri-02 Nos and BOP Lailong-01 Nos in AOR of 172 BN BSF under SHQ BSF JOWAI (SH. Pvdg IEI, fans and service connection and off grid solar plant)”
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(Group-A)
2Wiring for circuit/ submain wiring alongwith earth wire with thesize 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
3Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
4Providing and fixing of prewired 20/22 watt box type LED batten having 6000K/4000K CCT, extruded thermoplastic body with PC diffuser in unique square shape & 240 degree wide distribution directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing completeas required.Make- Havells/Phillips/Crompton/Panasonic/Bajajetc.as per direction of Engineer-In-charge.
5Supply,Installation, testing and commissioning of energy saving ceiling fan having specification :- Size-1200mm,Air delivery - 220 mm3,colour- Ivoury including wiring the down rods of standardlength (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable etc. as required.Make -Usha/Havells/Crompton
6Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
7SITC of exhaust fan 250 mm sweep inbuilt with decorative plastic body with shutter complete set in the exisiting opening including connections etc as required.Make-havells
8Supplying and fixing of 5 Watt ,four module LED foot light made up of polycarbonate material ,PCB material,having low power consumption with soft white glow Lumen outputi/c connection complete as required.Make - Crompton/Havells/Phillips
9Providing and fixing of prewired 6/8 watt circular/square surface mounted LED panel with premium diffuser to ensure glare free & even light distribution having 6000K/4000K CCT, directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing completeas required as per direction of Engineer-In-charge.Make- Havells/Phillips/Crompton
10Providing and fixing of prewired 5 watt led batten mirror light with 100 lumens per watt ,1 feet lengthwith premium diffuser to ensure glare free & even light distributionhaving 6500K/6000K CCTdirectly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing completeas required as per direction of Engineer-In-charge.Make- Havells/Phillips/Crompton
11SITC 45/48Watt LED street light I/P voltage 220V AC, with suitable electronic driver and high power LED as light source,with secondary optics made in pressure die cast housing with toughned glass IP66 protection on existng GI pipe bracket i/c connection etc as required.Make- - Havells/Crompton/Bajaj/SYSKA
12P/F of 40/43mm Dia 1.5Mtr long GI Pipe (Medium class) bracket on the existing wall with suitable MS clamp 2Nos and Nut & bolt for mounting of LED fitting i/c painting etc as required as per direction of engineer incharge.
13Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of Single poles in the existing MCB DB complete with connections, testing and commissioning etc as required. (Make:Havells/ Legrand/ ABB /Schenider/ standard)
14Supplying and fixing 8 Way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and comissioning etc as required.
15Supplying and fixing 40A,double pole 240 V isolator in the existing MCB DB complete with connections,testing and comissioning etc as required.
16Supplying and fixing two way centre off 40A 2P MCB Changeover switch in the existing MCB DB complete with connections ,testing and comissioning etc as required .(Make-Havells/Legrand/ABB/Schenider/Standard)
17Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
18Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
19Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc (with charcoal/ coke as salt )as required
20Providing and fixing 25 mm X 5 mm G.I strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as req.
21Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long GI Tube , having single prong on top, with 85 mm dia 6 mm thick G.I. base plate including holes etc complete as required
22Jointing copper/ G.I. tape ( with another copper/ G.I. tape, base of the finial or any other metallic object) by reveting/ nut bolting/ sweating and soldring etc as required
23Providing and fixing G.I. Tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required ( For Horizontal run)
24Providing and fixing G.I. Tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required ( For vertical run)
25Providing and fixing testing joint, made of 20 mm x 3 mm thick GI strip, 125 mm long with 4 nos of G.I bolt, nut chuck nuts and spring washer etc complete as required.
26Providing and laying GI tape 32 mm x 6 mm from earth electrode directly in ground as required
27Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size upto 35 Sqmm direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.
28Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size Upto 35 sq. mm (clamped with 1 mm thick saddle) on wall surface/open as required
29Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade upto 35 sq. mm size in the existing RCC/ HUME/ METAL pipe as required.
30Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required.
31Supplying of PVC sheathed / XLPE Armoured Aluminium conductor power cable of 1.1 KV grade of 2 X 16 Sqmm size. (make: Polycab/Havells/finolex)
32Supply, Installation, Testing and Commissioning of1 Kwp off-Grid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended ,consisting of Mono/Poly Crystalline silicon solarcells, necessary protections, earthing , Floor mounted on GI structure of suitable strength with following components complete as required:- (a) Solar Photovoltaic Module of capacity 330Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730 Part-2 Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years.(b) Solar Inverter suitable for 1 KWp solar panel inbuilt with PWM/MPPT solar charge controller , pure sine wave output, output voltage suitable to generate AC Power with efficiency not less than 97% , total harmonic distortion less than 3%(c) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing AC/DC cable along with glands, lugs,MC4 Connector and other accessories etc. as required. (d) Lightning and surge voltage protection. (e) Supplying and installation of 2 nos 150 Ah solar Batteries. f) Connections & Interconnections by supplying & fixing required size XLPE/PVC insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, Solar Inverter along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required.Cost for 01 kWp off grid solar PV system i/c providing, installation, testing, commissioning, transportation, incurrence, warranty/ guarantee, monitoring and maintenance for 5 (Five) years and applicable taxes for 01 kWp standalone solar power plants, panel with 6 Hrs. battery backup as per the MNRE specification complete as required.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail