Rural Works Division has published Tender For Construction Of Road And Bridge Work -Road From Mrl02 Brtf Road To Taipa (Upgradation). Submission Date for this Tender is 07-10-2023. Road Work Tenders in Kurung Kumey Arunachal Pradesh. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | SH: SITE CLEARENCE |
2 | Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlierand disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, up to a lead of 1000m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per technical specification Clause 201.i)By Manual means:- (a) In area of thorny jungle. |
3 | SH: SETTING OUT |
4 | Construction of reference benchmark and working bench mark as per Fig 1600.1 as per drawing and technical specification Cluase 1602.1 |
5 | Reference Pillar |
6 | Back Pillar. |
7 | Job Pillar |
8 | SH: EARTHWORK IN ROAD FORMATION |
9 | Earthwork in excavation in soil n hilly area by mechanical means including cutting and trimming of sides slopes and disposing of excavated earth with a lift upto 1.5m and a lead upto 20m as per Technical Specification clause 1603.1 |
10 | Excavation in ordinary rock using mechanical means including loading in a truck and carrying of excavated material to embankment site with a lift upto 1.5 m and lead upto 20 m as per Clause 1603.2. |
11 | (SH : KUTCHA SIDE DRAIN) |
12 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. |
13 | SH:Hume Pipe Clvt. 1000 mm dia. |
14 | Earthwork in excavation for foundation of structures upto 3 m depth as per drawing and technical specification Clause 1104 includding setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. |
15 | Plain Cement Concrete M10 (1:3:6 nominal mix) in levelling course below open foundation of Head walls as per drawings & Technical Specification Clause 1109 |
16 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 [P.C.C. grade M 20 Nominal mix (1:2:4)] |
17 | Bedding for Pipe [ Type A ( Concrete Cradle ) Bedding ] Laying concrete cradle bedding with M15 Grade Cement Concrete as per Clause 1105 (i) |
18 | Stone Masonry Work in cement mortar in foundation of Head walls complete as per drawing and technical specification Clasue 1109 [In 1:4 cement mortar] |
19 | Providing and laying reinforced cement concrete pipe NP3for culverts on first class bedding of granularmaterial in double row includingfixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets as per Clause 1106. [1000 mm dia] |
20 | Providing and laying boulder apron for bed protection with stone boulders of minimum size and weight as per Table 1300.1, no fragmentweighing less than 25 kg laid dry complete as per drawing and technical specifications Clause 1301 |
21 | Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8[Granular material] |
22 | Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 |
23 | Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications Clause 1302 |
24 | Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 [R.C.C grade M 20 For design mix RCC M 20] |
25 | Supplying, fitting and placing HYSD bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202 |
26 | SH.CROSS DRAINAGE WORKS:[SLAB CULVERT 2.00 METRE SPAN] |
27 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trnches with excavated suitable material. |
28 | Providing concrete for plain concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 (PCC grade M10). a) Foundation & Plinth |
29 | Stone masonry ( second sort) with hard stone in foundations and plinth as per drawing and techanical specifications Clauses 702,704,1202&1203 in cement mortar 1 : 3 (1 cement : 3 fine sand).(CRM) |
30 | Stone masonry ( second sort) with hard stone in foundations and plinth as per drawing and techanical specifications Clauses 702,704,1202&1203 in cement mortar 1 : 4 (1 cement : 4 fine sand).(CRM) |
31 | Back filling behind the abutment, wing wall and retain wall completeas per the drawing & technical specification. |
32 | Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 |
33 | Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204(R.C.C grade M 20) |
34 | Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204(R.C.C grade M 20) |
35 | Providing concrete for plain concrete for curtain walls complete as per drawings and technical specifications Clause 1303.3(PCC grade M10) |
36 | Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5.a) For nominal mix 1:2:4[hand mixing] |
37 | Supplying, fitting and placing with MS bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202. (The steel to be used should be from primary). a)MS Deformed Bars |
38 | SH: Breast wall - 2.00 mtr high( As per IRC SP-20-1979) |
39 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. |
40 | Stone masonry ( second sort) with hard stone in foundations and plinth as per drawing and techanical specifications Clauses 702,704,1202&1203 in cement mortar 1 : 3 (1 cement : 3 fine sand).(CRM) |
41 | Stone masonry ( second sort) with hard stone in foundations and plinth as per drawing and techanical specifications Clauses 702,704,1202&1203 in cement mortar 1 : 4 (1 cement : 4 fine sand).(CRM) |
42 | Providing weepholes in stone masonary RCC work, wing walletc 100 dia AC pipe extending through the full width of the structures with slope of 1(V) :20(H) towards drawing face complete as per drawing and techanical specification Clauses 614,709.1204.3.7 |
43 | Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 [Granular material] |
44 | SH: Retaining wall -2.00 mtr highSausage wire crated boulder Protection Structure.As Per IRC: SP:116-2018, Page No. 54 (Clause 7.2) Annexure-II Table No.II-1 |
45 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. |
46 | Providing and laying wire created boulder structures boulder size 22.5 cm to 45 cm having 25 kg average weight for each i/c dumping/laying in S.W.G. Wire mesh of 10 cm x 10 cm (woven diagonally) 4mm dia i/c packing with small size stone spalls and carrying of boulders from a lead of 50 mtr and lift up to 1.5 mtr i/c lying properly the mesh by cutting the mouth and hoisting of wirewhere felt necessary as per direction of Engineer-in-Charge technical specifications Clause 1301. ( Based on SDB Rural Road Chapter-14, Item No.14.2) |
47 | SH: Pavement |
48 | SHOULDER |
49 | Construction of subgrade and earthen shoulders with approved material obtained from way cutting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2as per Technical Specification Clause 303.1. |
50 | Granular Sub-base with Well Graded Material ( Clause Table 400.2) Grade-B :- |
51 | Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavatorat OMC, and compacting with smoothwheelroller to achieve thedesired density, complete as per Drawing and Technical Specificateion Clause No 401[Gravel/Soil-Aggregate Base (Table 400.2) Grading -B] |
52 | WBM 2 FOR BASE COURSE ( 75 mm thick):- |
53 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smoothwheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fillup the intersices of coarse aggregate,watering and compacting to the required density Grading 2 as per Technical Specification Clause 405.(a)By Manual means. |
54 | WBM 3 FOR BASE COURSE ( 75 mm thick) |
55 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smoothwheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fillup the intersices of coarse aggregate,watering and compacting to the required density Grading 3 as per Technical Specification Clause 405.(a)By Manual means. |
56 | PRIME COAT |
57 | Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502 [Low porosity] |
58 | Tack Coat |
59 | Providing and applying tack coat with Bitumen emulsion (RS-1)using emulsiondistributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503. |
60 | Mix Seal Surfacing |
61 | Mix Seal Surfacing : Providing, laying and rolling of close-graded premix surfacing material of 25 mm thickness composed of 11.2 mm to 0.9 mm (Type-A) or 13.2 mm to 0.9 mm (Type-B) aggregates using penetration grade bitumen to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 8-10 kN static roller and finishing to required level and grades as per Technical Specification Clause 509 |
62 | SH : SideDrain [Trapizoidal Shape] ( Cross section as per IRC SP-20-2002 -RRM , Page 113 , Fig. 6.2.c ) |
63 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. (i) Upto 3m depth |
64 | Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 803,1202 ans 1203[M -15 Plain base concrete] |
65 | Stone Masonry work in cement mortar in foundation complete as per drawings and technical specification Clauses 702,704,1202 & 1204 [CRM in CM 1:5] |
66 | Cement plaster 15 mm thick 1:4 on stone masonry |
67 | SH : SideDrain [V- Shape] ( Cross section as per IRC SP-20-2002 -RRM , Page 113 , Fig. 6.2.c ) |
68 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. |
69 | Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 803,1202 ans 1203[M -15 Plain base concrete](Hand Mixing) |
70 | Stone Masonry work in cement mortar in foundation complete as per drawings and technical specification Clauses 702,704,1202 & 1204 [CRM in CM 1:5] 2nd Sort |
71 | Cement plaster 15 mm thick 1:4 on stone masonry |
72 | SH: GUARD POST |
73 | Earth work in excavation for structures |
74 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. |
75 | RCC M 20 grade |
76 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 804, 805, 806, 807.1202 and 1204 |
77 | HYSD steel bars |
78 | Supplying, fitting and placing HYSD bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202 |
79 | Painting two coats including prime coat on new concrete surface |
80 | Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification Clause 1701 |
81 | SH :-Road sign Board |
82 | Reinforced cement concrete M15grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 |
83 | a). Ordinary 1 Km-stone (size - 66 X 35 X 25 cm) |
84 | b)5th Km. Stone (size 107.50x58x25cm) |
85 | c)200m stone (precast) |
86 | Providing and erecting direction and place identification retro-reflectorised sign asper IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thickwith areaexceeding 0.9 sqm supported on mild steel angle iron posts 75 mm x 75 mm x 6 mm, 2 Nos.firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701 |
87 | Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thickwith areaexceeding 0.9 sqm supported on 2 inch dia GI Pipe firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701 |
88 | Providing and fixing of semi reflective cautionary, mandatory and informatory sign board as per IRC:67 made of 1.5 mm thick MS Sheet duly stove white colour in front and gray colour on back with red reflective border of 65 mm width and required letters and figures with reflective tape engineering grade as per Clause 1701.3.9 of MORD for Rural Roads of required shade and colour supported and welded on 47mm x 47 mm x 12 SWG sheet tube firmly fixed to the ground by mean of properly designed foundations with M-15 grade cement concrete 450x450x600 mm, 600 mm below ground level as per approved drawing Clause 1701.2.2 |
89 | Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704 |
90 | Providing and Fixing PMGSY Logo Board at starting point |
91 | Providing and fixing of typical PMGSY Logo board as per MORD specifications and drawing of cast-in-situ RCC,(Size of RCC post 25cmx25cmx90cm below G.L. & finishing with 15mm pluster 1:4 and neat cement punning, applying priming coat, painting 15cmx15cmx260cm above G.L.),(Size of board 1x 85cmx85cmx7.5cm, ) incl.earth work,and lettering with appropiate colour with required shade of approved quality ready mix paint. |
92 | Providing and Fixing Title information Board of PMGSY Project(RCC) |
93 | Providing and fixing of typical PMGSY Citizen information sign board as per MORD specifications and drawing of cast-in-situ RCC,(Size of RCC post 25cmx25cmx90cm below G.L. & 15cmx15cmx245cm above G.L.),(Size of board 2x 90cmx80cmx7.5cm, ) incl.earth work, finishing with 15mm pluster 1:4 and neat cement punning, applying priming coat, painting and lettering with appropiate colour with required shade of approved quality ready mix paint. |
94 | Providing and Fixing Citizen information Board of PMGSY Project(RCC)"A" |
95 | Providing and fixing of typical PMGSY Citizen information sign board as per MORD specifications and drawing of cast-in-situ RCC,(Size of RCC post 25cmx25cmx90cm below G.L. & 15cmx15cmx245cm above G.L.),(Size of board 2x 90cmx80cmx7.5cm, ) incl. work, finishing with 15mm pluster 1:4 and neat cement punning, applying priming coat,painting and lettering with appropiate colour with required shade of approved quality ready mix paint. |
96 | Safety Devices and Signs in Construction Zones |
97 | Provision and fixing of traffic signs for limited period at suitable locations in construction zone comprising of warning zone, approach transition zone, working zone and terminal transition zone with a minimum distance of 2-3 m from the edge of the carriageway. The bottom edge of the lowest sign plate to be not less than 2 m above the road level, fixed on 600 mm x 600 mm x 6 mm angle iron post, founded and installed as per approved design and drawings, removed and disposed of after completion of construction work, all as per IRC:SP:55-2001. |
98 | Men at work |
99 | Diversion |
100 | Road closed |
101 | Stop |
102 | Slow |
103 | Speed limit |
104 | Routine Maintenance |
105 | First Year |
106 | Second Year |
107 | Third Year |
108 | Fourth Year |
109 | Fourth Year |
110 | TOTAL |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy