Bids Are Invited For Supplying And Fixing The Following Modular Switch / Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 3 Pin 5 / 6 A Socket Outlet Supplying And Fixing The Following Modular Switch / Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 5 / 6 A Switch Supplying And Fixing The Following Modular Switch / Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 6 Pin 15 / 16 A Socket Outlet Supplying And Fixing The Following Modular Switch / Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 15 / 16 A Switch Supplying And Fixing The Following Size / Modules, Gi Box Along With Modular Base &And Cover Plate For Modular Switches In Recess Etc. As Required. 1 Or 2 Module ( 75Mmx75mm ) Supplying And Fixing The Following Size / Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. 4 Module ( 125Mmx75mm ) Supplying And Fixing The Following Size / Modules, Gi Box Along With Modular Base And Cover Plate For Modular Switches In Recess Etc. As Required. & Module ( 125Mmx125mm ) Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate And Switch Box Excluding Modular Plate As Required. Wiring For Circuit / Sub Main Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required. 2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire Wiring For Circuit / Sub Main Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required. 2 X 2.5 Sq. Mm + 1 X 2.5 Sq, Mm Earth Wire Wiring For Circuit / Sub Main Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required. 2 X 4 Sq. Mm + 1 X 4 Sq. Mm Earth Wire Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Condult As Required: 25 Mm Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Condult As Required: 20 Mm Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing, Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 8- Way ( 4+24 ) , Double Door Supplying And Fixing The Following Rating, Double Pole, ( Single Phase And Neutral ) , 240 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current Of 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 63 A Supplying And Fixing 63 A Rating, 415 V, 10 Ka, C Curve, Four Pole Miniature Circuit Breaker Suitable For An Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required., Cat- Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single There Isnt Providing And Erecting Xlpe ( Is:7098 ) ( 1 ) -88 Isi Armoured Cable Multistrand Copper Conductorfor 1.1 Kv. To Be Laid Onthe Wall With Necessary Clamps Or In Existing Trench / Pipe At A Road Crossing Or Floor Ofthe Following Size Of Cables. ( B ) 4 Core 16 Sq. Mm Providing And, Fixing Heavy Duty Flange Type Brass Cable Gland With Rubber Ring For Pvc Insulated Armoured Cable Complete Withoutgoing Tails, Insulating Tape, Etc For The Following Size Of Cables. ( D ) 2 To 4 Core 16 Sq. Mm Solderless Crimping Type Copper Lugs Conforming To Is Suitable For Cable Of The Following Size Evenly Crimped With The High-Pressure Tool And Connected To Switchgear Terminals With Brass / Cadmium Plated Nut Bolts In An Approved Manner. ( C ) 16 Sq.Mm. Providing And Erecting Hot Deep Galvanised Iron Strip Wire 8 To 16 Swg. Total Quantity : 3378