| 1 | Dismantling all types of masonary excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. |
| 2 | Stripping off worn out plaster and raking out joints of walls, ceilings etc. upto any height and in any floor including removing rubbish within a lead of 75 m as directed |
| 3 | Earthwork in excavation of foundation trenches or drains in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete(a) Depth of excavation not exceeding 1,500 mm |
| 4 | Cement concrete with graded stone ballast (40mm size excluding shuttering) in ground floor (a) 1:3:6 proportion |
| 5 | Ordinary cement concrete (mix 1:1. 5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement, if any, in ground floor as per relevant IS codes.(a) G.F. |
| 6 | (b) 1st Floor |
| 7 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. initial straightening and removal of loose ruist (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersecftion, complete as per drawing and direction(a) G.F. |
| 8 | (b) 1st Floor |
| 9 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (a) 25 mm to 30 mm thick wooden shuttering as per decision & 1st floor(i) G.F. |
| 10 | (ii) 1st Floor |
| 11 | Supplying fitting and fixing door frame with M.s. angle as per drawing & direction of required section. The holes for counter sunk machine screw & nuts will be such as to fit 8 to 10 mm iron screw. The counter sunk nut to be welded. The nuts are to be welded after careful checking with screw. All welding spots should be properly filed or rounded smooth including cost of swelding hkinges for hjinge cleats, lugs for hasp bolt, socket bolt etc. and necessary MS clamps of 25 mm x 6 mm flat 225 mm long as per direction welded to the frame fitted and fixed in position excluding cost of concrete |
| 12 | Supplying, fitting & fixing fibre reincforced polymer (FRP) composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria. |
| 13 | Brick work with 1st class bricks in cement mortar (1:6) - 1st floor |
| 14 | 125 mm thick work with 1st class bricks in cement mortar (1:4) - 1st floor |
| 15 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (ground floor). [excluding cost of chipping over concrete surface] (a) With 1:4 cement mortar - 15 mm thick 1st floor |
| 16 | (b) 10 mm G.F. |
| 17 | 1st floor |
| 18 | Neat cement punning about 1.5 mm thick in wall |
| 19 | Supplying, fitting & fixing Marble slab/tile of 15 to 18 mm thickness in floor, lobby, stair, landing & treads etc. over 20 mm (av.) tick base of cement mortar (1:2) laid with white cement slurry @4.4 kg/sq.m before placing marble & jointed with white cement slurry @ 2.0 kg/sq.m with necessary pigments incljuding grinding and granite polishing as per direction of Engineering-in-charge in ground floor. (White cement and pigment to be supplied by the agency)(a) with Makrana plain pink / Adranga pink / Rarbh Gulabi / Udaypur pink / Udaypur Green / Black Bhaslana, (i) Area of each slab/tile exceeding 0.60 sqm. but not exceeding 1.00 sq.m |
| 20 | Supplying, fitting and fixing 1st quality ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10 mm) fixed with araldite at the back of each tile & finishing the jonts with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (A) Wall with sand cement mortar (1:3) 15 mm thi ck & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 kg.sqm & joint filling using white cement slurry @ 20 kg/sqm,(B) Area of each tile above 0.09 sqm (i) Coloured decorative a. 1st floor |
| 21 | Supplying, fitting and fixing MS clamps for door and window frame made of flat bent bar, end bifurcated with with necessary screws etc. by cement concrete (1:2:4) as per direction. (Cost of concrete will be paid separately) each additional floor or 4 m. beyond the initial 8m. or part thereof(a) 40 mm x 6 mm, 200 mm length |
| 22 | Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. (i) 100 mm x 58 mm x 1.90 mm |
| 23 | Iron socket bolt of approved quality fitted and fixed complete (i) 225 mm long x 10 mm dia bolt |
| 24 | Brass hasp bolt of approved quality fitted and fixed complete (oxidised) with 16 mm dia rod with centre bolt and round fitting (a) 250 mm long |
| 25 | Anodised aluminium decorative handle (hexagonal/fluted) of approved quality fitted and fixed complete(i) 150 mm plate x 10 mm dia rod x 12 mm hexagonal / fluted |
| 26 | Applying interior grade Acrylic Primer of approved quality and brand on plastered or concrete surface old or new surface to receive distemper/ acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC (in ground floor) (a) One coat (i) Water based interior grade acrylic primer(a) 1st floor |
| 27 | Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer\"s specification) including cleaning and smoothing of surface - two coats(a) 1st floor |
| 28 | applying exterior grade acrylic primer of approved quality and brand on plastered or concrete surface old or new surface to receive distemper/ acrylic emulsion paint including scraping and preparing the surface throughly, completge as per manufacturer\"s specification and as per direction of the EIC (in ground floor) bound primer of approved quality including smoothening surfacdes by sand1.(a) for trusses spanning upto 12.00 m a. G.F |
| 29 | b. 1st Floor |
| 30 | Protective and decorative acrylic exterior emulsion paint (a) Super protective 100% acrylic emulsion a. G.F. |
| 31 | b. 1st Floor |
| 32 | Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand (payment to be made on measurement of finished quantity) (a) Do by fine sand |
| 33 | Providing and fixing of false ceiling with powder coated exposed G.I. grid suspension system (E-Grid U-1520 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200 mm c/c) consisting of main runner 3600 mm long. Cross Tee 1200 mm/600 mm long and wall angle. The wall angle shall be fixed on PVC dash fasteners on the perimeter of the wall by steel screw with distance 300 mm c/c. The main runners to be placed @1200 mm. The cross Tee 1200 mm will be inserted in the pre-cut slots of main runner at a regular interval of 600 mm to form a modular grid of 1200 mm x 600 mm. Additional cross Tees of 600 mm shall be placed perpendicular to the cross Tee 1200 mm mong to finally form a grid of 600 mm x 600 mm. Grid of module size 600 mm x 600 mm shall be supported by 6 mm dia G.I. wire from purlins/soffit. 15 mm thick OW acoustic board (Mineral Fiber Acoustic Ceiling Tiles) of spproved pattern and size 595 mm x 595 mm with NRC value>0.65 should be placed in the grid module to form a false ceiling. All complete as per the drawing & directions of Engineer-in-charge. In ground floor |
| 34 | (a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 35 | (b) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 36 | Painting with best quality synthetic enamel paint or approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary |
| 37 | On steel or other metal surface |
| 38 | Supplying, fitting and fixing Anglo-Indian WC in white glazed vitreous (a) with \"P\" trap (with vent) |
| 39 | Supplying, fitting and fixing squating plate with integral flushing in white vitreous chinaware of approved make in cement concrete (6:3:1) with jhama chips complete. (Payment of concrete will be paid separately)(i) 450 mm x 350 mm |
| 40 | Supplying, fitting and fixing vitreous china best quality approved make wash basin with C.I. brackets on 75 mm x 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia, C.P. chain with chain with rubber plug of 30 mm dia, approved quality PVC waste pipe with heavy brass CP nut including mending good all damages and painting the brackets with two coats of approved paint(i) 630 mm x 450 mm size |
| 41 | Supplying, fitting and fixing 10 litre PVC low-down cistern fonforming to I.S. specification with PVC fittings completge, C.I. brackets including two coats of painting to bracket etc. |
| 42 | Supplying, fitting and fixing bib cock or stop cock (a) (i) Chromium plated bib cock with wall flange (equiv. to code no. 5047 & model - florentine of Jaquar or similar brand) |
| 43 | Supplying, fitting and fixing bibcock or stop cock (a) (i) Chromium plated concealed stop cock heavy duty (equiv. to code no. 5083 & model - Florentine of Jaqauar or similar brand) |
| 44 | Supplying, fitting and fixing flat back urinal in white vitreous chinaware of approved make - 635 mm x 395 mm x 420 mm |
| 45 | Supplying, fitting and fixing Peet\"s valve fullway gunmetal standard pattern best quality of approved brand bearing ISI marking with fittings (tested to 21 kg per sq cm) (i) 40 mm dia(i) 40 mm dia |
| 46 | (ii) 40 mm dia |
| 47 | Supplying, fitting and fixing PVC pipes of approved make of schedule 80 (medium duty) conforming to ASTMD-1785 and threaded to match with GI pipes as per IS:1239 (Part-I) with all necessary accessories specails viz. socket, bend, tee, union, cross, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accosories, specials. Payment for painting will be made separately)(a) For exposed work PVC pipes - 40 mm |
| 48 | 25 mm |
| 49 | 20 mm |
| 50 | (b) For concealed work - 20 mm |
| 51 | Constructing Inspection pit of inside measurement 600 mm x 600 mm upto 600 mm (depth) with 250 mm thick 1st class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) swith stone chipsover a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and outside walls upto G.I. and 20 mm thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as direction, neat cement finishing to intire internal surfaces, top of the pit covered with 1090 mm thick RCC slab (1:1.5:3) with stone chips and necessary reinforcement upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. RCC manhole cover of approved make supplied, fitted and fixed in the slab with necessary earthwork in excavation in all sorts of soil, filing sides of the pit with earth and removing spoils after work completge in all respect with all costs of labout and materials(i) with Pakur variety (SAIL/TATA/RINL) |
| 52 | Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia RCC malnhole cover (heavy type) of approved make supplied, fitted and fixed in the 100 mm thick RCC (1:1.5:3) top slab with necessary fittings, 20 mm thick cemebt plaster (4:1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4:1) to outside wall upto 200 mm below G.L. floor finished with 25 mm thick grey artificial stone over 100 mm thick RCC (1:1.515:003) bottom slab including supplying, fitting and fixing all necessary specials, fittings, SW tees, CI foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and refilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear watger, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement will all costs of labour and materials. Note: (i) Finished level of septic tank should be 400 mm from ground level, (ii) Height of 50 mm ventilation pipe & mosquito proof mesh, should be followed as per IS:2470, Part-I payment will be made separetly on the basis of actual height based on relevant I.S. code, (iv) For 50 users |
| 53 | Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20 mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15 mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the RCC cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including RCC cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. RCC manhole cover (heavy type) of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making necessary fittings, necessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the excess earth from the premises as per direction complete in all respect with all costs of labour and materials with 250 mm thich dry brick work and 250 mm thick cement brick work (1:6) and 1.00 m inside dia (SAIL/TATA/RINL) |
| 54 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992(A) (1) Single socketed 3 meter length 110 mm |
| 55 | Plain Tee 110 mm |
| 56 | Door Tee 110 mm |
| 57 | CGST & SGST (18%) |
| 58 | Labour Welfare Cess (1%) |
| 59 | Contingency (3%) |