Military Engineer Services-MES has published Tender For Provision Of Repair Shed For ‘C’ Veh With Hard Standing With 2 Ton Travelling Trolley At Fd Wksp Coy In Army Area Under Ge ( Army ) No. 01 Jodhpur. Submission Date for this Tender is 03-11-2023. Forming Tools Tenders in jodhpur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

39768360
Corrigendum : Tender For Provision Of Repair Shed For ‘C’ Veh With Hard Standing With 2 Ton Travelling Trolley At Fd Wksp Coy In Army Area Under Ge ( Army ) No. 01 Jodhpur
Open Tender
Indian
Rajasthan
jodhpur
03-11-2023

Tender Details

Provision Of Repair Shed For ‘C’ Veh With Hard Standing With 2 Ton Travelling Trolley At Fd Wksp Coy In Army Area Under Ge ( Army ) No. 01 Jodhpur; 1 Surface Excavation Not Exceeding 30Cm And Averaging 15 Cm Deep And Getting Out In Any Type Of Soil Complete All As Specified And As Directed. 2 M&L For Hardcore Of Gaugeexceeding 63 Mm But Not Exceeding 100 Mm Of Brokenstone Or Boulders, Deposited, Spread And Levelled In Layers Not Exceeding 15 Cm Thick, Watered And Rammed To A True Surface, Compaction And Consolidation With Power Roller, Complete All As Specified And As Directed. 3 Excavation In Post Holes Each Not Exceeding 0.5 Cu.M, Getting Out In Any Type Of Soil, Including Returning, Filling In And Ramming Earth Or Broken Rubble Mixed With Earth Around In Layers Not Exceeding 25Cm Thick, Watering And Removing Surplus Soil To A Distance Not Exceeding 50M And Making Good Surface Complete All As Specified And As Directed. 4 M&L Cement Concrete 1:3:6 Type C-1 By Using 20Mm Graded Crushed Stone Aggregate As In Foundation, Filling, Mass Concrete, Embedded Concrete For Fencing Post Hole, Including Necessary Form Work Complete All As Specified And As Directed. 5 S&F Steel Work In Tubular Trusses Including Special Shaped Washers Etc Complete Using Erw Or Induction Butt Welded Tubes Confirming To Is:1161-1979 Grade St-240 Complete All As Specified And As Directed. 6 M&L For Mild Steel Work Confirming To Fe - 410, Grade E-250 , Quality-A, As In Roof Trusses ( Framed ) , Trussed, Purlins, Crane Gantries, Rails And Fastenings And Heavy Bracket Framing ( Beam, Tee, Angle, Channel Or Flat Sections ) Including Distance Pieces, Cleats Etc. Etc Complete All As Specified And As Directed. 7 S&F Plates ( Plain Or / Mdsplate Chequered ) Channels Square Cut Or Notched ( Ordinary And Counter Sunk ) Forming Holes With Riveted Bolted Or Welding Attachement 8 M & L For Preparing New Steel Surfacesof Any Descriptionexc 10 Cm In Width, Priming With Red Oxide And Applied Two Coat Of Synthetic Enamel Paint Complete All As Specified And Directed. 9 S&F Prepainted Galvalume Aluminium Zinc Coating Gi Based Corrugated Steel Sheet 0.5Mm Thick Of Any Colour Having Tensile Strength Of 550 Mpa As In Roof Covering / Cladding To Wall, Fixed With Self Tapping Screws All As Specified And As Directed. 10 M&L 100 Mm Thick Pcc 1:4:8 Type D2 Using 40Mm Graded Crushed Stone Aggregate For Sub Base As In Floor Complete All As Specified And As Directed . 11 M & L For Cement Concrete Work In Pavement / Hard - Standing Of Flexural Strength 40 Kg / Per Square Centimetre In Field Using 400 Kg Of Cement Per Cubic Metre, Thickness Of Concrete 25 Cm Or Less Complete All As Specified And Directed 12 Excavating In Trenches, N Exc 1.5 M Wide And N Exc 1.5 M In Depth; For Foundation, Etc. Or For Shafts, Wells, Cesspits, Manholes, Pier Holes, Etc. N Exc 10 Sq M On Plan And N Exc 1.5 M In Depth And Getting Out Any Type Of Soil All As Speicfied And Directed. 13 M&L Pcc 1:4:8 Type D2 By Using 40Mm Graded Stone Aggregate As In Foundations Filling And Mass Concrete Complete All As Specified And Directed. 14 M&L For Squarred Rubble Walling Jodhpur Type Regular Coursed Well Bonded , Bedded And Solidly Hearted Built In Cement Mortar 1:6 Complate All As Specified And Directed. 15 Extra Over Squared Rubble Stone Walling Jodhpur Type Regular Course For Hammer Dressing To Face Of Stone With Max Depression On Face From A Straight Edge Not Exc 20Mm And Dressing Complete To Squared Rubble Walling, Regular Coursed, Jodhpur Typeall As Specified And Directed. 16 M&L For Keyed Pointing To Square Rubble Masonryjodhpur Type Regular Course In Cm 1:3 All As Specified. 17 M&L For Preparation Of New Plastered Or Un-Plastered Surfaces Of Walls And Applying Two Coats Of Cement Base Paint Over A Coat Of Chalk White, Complete All As Specified And As Directed. 18 M&L For Pcc 1:2:4 Type B1 Mix Using 20Mm Graded Stone Aggregate As In Hold Fast Iron Fixing, Coping, Chamfered Edgesincluding Necessary Form Work All Asspecified. 19 Removing Excavated Material N Exc. 50M And Depositing Where Directed At A Level N Exc. 1.5 M Above The Starting Point All As Specified And Directed. 20 Returning, Filling In, Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exc 25 Cm. All As Specified And Directed. 21 S&F Expanded Metal, N Exc 4 Kg Cut To Length, Bent To Shape Required And Tying With And Including Annealed Mild Steel Wire Not Less Than 0.9Mm Dia Or Fixing With Galvanised Steel Staples Supplied And Fixed Complete To Wood Or Steel Members 22 Supply And Lay In Trenches / On Wall / On Pole / In Duct / Through Protection Pipe, Xlpe Insulated, Screened, Pvc Bedded, Galvanized Steel Strip Or Wire Armoured, Electric Power Cables Heavy Duty Lt Cable, 1100 Volts Grade With Aluminium Conductor Cross Sectional Area16 Sqmm 4 Core Size Including Retrieving / Taking Out / Taking Down Old Unserviceable Cable From Duct / Trenches / Pipes / Pole / Wall Etc. Including Brick Cover And Protection Pipe And Disconnecting The Connections.Note:-Excavation Andearth Work, Sand Cushioning, Pcc Cable Cover And Protection Pipe Etc. Shall Be Measured And Paid For Separately. 23 M&L For Dry Clean Fine River Sand As In Sand Cushioningto Underground Cable Including Punning Down Ofsand Layer All As Specified And Directed. Note :- Punnedthickness Shall Only Be Measured And Paid. 24 Supplying And Laying Un-Reinforced Precast Concrete Cable Cover, Class Lv, Type 1, Flat, Size 250X150mm X40 Mm 25 M&L For Galvanised Steel Tubing, Light Grade, For Protection Of Cable, Laid In Trenches / Road Crossing / Floor Or Fixed To Pole / Wall With All Fittings, Of Size 40 Mm Bore. 26 M & L For Surface Point Wiring Complete With Multistranded Copper Conductor 1.5 Sqmm Pvc Insulated Unsheathed Single Core Frlsh Cable 1100 Volt Grade, Confirming Is 694 & Colour Code In Conduit System Of Wiring, Drawn Through In And Includingnon-Metalicpvcsurface Conduit Of Size 20 / 25 Mm Or Med Grade As Required As Site, Totallysurface For Floors / Ceiling Or Fixed On Surface Of Walls / Columns / Beam / Tie Beam Etc By Means Of Saddles And Clips Etc Incl All Conduit Accessories / Fittings Such As Tee / Elbow / Sockets / Junction Boxes / Inspection Covers Etc Of Heavy Grade, Isi Marked And Surface Pvc Gang Box.Wodden Box For Mounting Switch And Sockets , For Mounting Of Switches, Sockets Fan Regulators Etc Incl 1.5 Sqmm Frlsh Pvc Insulated, Unsheathed Flexible Multi Stranded Copper Conductor Cables As Continuous Earth Wire Connected To Metallic Bodies Of Luminaries / Fans Etc At One End And To Common Earth Dolly At Other End, Suitable For One Light / Fan Point Controlled By One, One Wayswitch, Complete All As Specified And Directed. 27 All As Per Item No 26.00 Here-In-Above But With 2.5 Sq Mm Single Core Multistanded Copper Conductor Cable For 3 Pin 16 Amp Socket Outlet On Independent Board . 28 S&F Socket Outlet 2 In 1, 6 Pin, 6 And 16 Amp Flush Type, 230 Volts, Isi Marked Complete All As Specified And Directed. 29 S&F Switch Piano Flush Type Single Pole One Way 16 Amp, 230 Volts, Isi Marked Complete All As Specified And Directed. 30 S&F Switch Piano Type, Single Pole, One Way, 5 / 6 Amps, 230 Volts, Isi Marked Complete All As Specified And Directed. 31 S&F Ceiling Rose, Three Terminals, Bakelite Body, 230 Volts, Isi Marked Complete All As Specified And Directed. 32 Supply And Fixing As Mcb Db Spn ( Double Door ) 4 Ways Including Bus Bar Neutral Link, Earth Bar And Din Rail, Recessed With Wall Surfaces By Chase Cutting And Making Good Surfaces Of Wallall As Specified And Directed By The Engr-In-Charge. 33 S&F Mcb, B Curve Type, 10 Ka, 6 To 40Amp, Spn With Over Load And Short Circuit Protection, Isi Marked Complete All As Directed. 34 S&F Mcb, B Curve Type, 10 Ka, 6 To 32 Amp, Single Pole With Over Load And Short Circuit Protection, Isi Marked Complete All As Directed. 35 Supply And Fixing Led Flood Light 70 Watt 230 V Ac Outdoor Type With Thermal Management In Multiple Optics And Equipped With Ip66 Protection, With Impact And Corrosion Resistant Complete With Driver And Lamp 36 S&F Bldg Security Ledlight Luminaire Of 35 Watts Having Ip 65 Protection Fiting Made Out Of Pressure Die Cast Aluminium Housing, Operating Voltage 140-270 Volts With In Built Surge Protectore, Toughened Glass With And Including Sutaible Size Ofgi Bracket Including Drilling Holes, Nuts & Bolts 2 Coats Of Red Oxide Primer On Gi Pipe And Fixing With Wall Security Light On Building Wall Connecting Cable Complete All As Directed. 37 S&F Air Circulator Wall Fans 230 V Single Phase Oscillating 450 Mm Sweep , Copper Winding, Heavy Duty Motor, Suitable For Wall / Pole / Pipe / Piller Mounting All As Directed. 38 S & Fsub Main Wiring With Two Runs Of Pvc Insulated But Unsheathed Multi Stranded Copper Conductor Frlsh Cable 1100 Volt Grade Of Size 4 Sqmm And One Run Of 4 Sqmm Single Core Pvc Insulated But Unsheathed Multi Stranded Copper Conductor Frlsh Cable ( Phase-Red, Neutral-Black, Earth-Green ) 1100 Volt Grade As Earth Lead Duly Coneected With Earth Dolly Drawn Through In And Includingnon Metallic Pvc Conduit Of Size 25 Mm Dia ( External ) With Wall Thickness Not Less Than 1.8 Mm, Isi Marked Surface On Wall Includingaccessories Like Bends, Tees Junction Boxes, Etc Fixed In Wall Or Ceiling Etc. Complete As Directed By Engineer-In-Charge.Note: Two Runs Of Cable With One Run Of Earth Wire And Pvc Conduit Shall Be Measured & Paid For As One Length. 39 Materials And Labour For Earthingcomplete With Galvanised Iron Earth Plate Electrode 600 Mm X 600 Mm X 6 Mm Thick, Burried Directly And Preferably Vertically In Ground, Earth Pit Not Less Than 2.25 Mtr Deep Below Ground Level With Top Edge Of The Plate Not Less Than 1.5 M Below Ground Level Connetced With Galvanised Strip Of Size 25 X 4Mmby Means Of Nuts, Bolts, Check Nuts And Washers Made Of Galvanised Iron Or Steel Earthing Lead To Be Protected By Galvanised Iron Pipe 40 Mm Bore ( Medium Grade ) And Other End Connected To Earthing Test Point Or Lightening Arrestor Or Main Controlling Switch As Directed Including Providing Funnel With 20Mm Bore Galvanised Iron Pipe ( Light Grade ) , Wire Mesh, Charcoal Or Coke And Common Salt In Alternate Layer Of 15Cm ( Compacted Thickness ) All Round The Earth Electrode, Concrete Earth Pit In Pcc ( 1:3:6 ) Type C-1 ( With 20Mm Graded Aggregate ) , 50Mm Thick Precast Rcc ( 1:2:4 ) Cover Slab ( Re-Inforced With 8Mm Dia Tmt Bar @ 15 Cm C / C Bothways And Suitable Handle Made Of 10Mm Dia ) Including Necessary Earth Work In Excavation, Returning Filling And Removal Of Surplus Earth Upto A Distance Not Exceeding 50 M Etc All As Shown On Electrical Plate No. 3 Of Mes Schedule Part-I ( 2009 ) Complete Including Testing On Completion All As Specified And As Directed By The Engr-In-Charge.Note:- ( I ) Item Includes The Cost Of 7.5 Metre Gi Pipe For Protection Of Earth Lead. ( Ii ) Item Includes The Cost Of 7.5 Metre Gi Earth Lead. 40 S&Fand Testing Factory Made Sheet Metal Enclosurefor Mcb Db Tpn 4 Way 415 Volt With Double Door, Ip - 43 Protectionduly Withfixed In Wall / Concealed In Wall / Surface On Wall / Pile / Piller Complete And Making Good Disturbed Surfaces Of Wall, Floor Etc Including Electric Wire Connectionall As Directedby Engineer-In-Charge. 41 S&F Mcb Tpn, C Curve Type , 415 Volts, 32 Amps With Over Load And Short Circuit Protection, Isi Marked Complete All As Directed. 42 Supply, Install , Erection, Testing And Commissioning Eot Crane 2 Ton Capacity Comprising Following And Notes And Precommissioning Factory Test As Per Is Complete All As Directed By Eic 43 Type: Single Girder Eot Crane 44 Swl- 2T 45 Class & Duty- Class Ii As Per Is: 3177 & 807. 46 Span- 9 Mtr. Approx. 47 Height Of Lift - 5 Mtr. 48 Bay Length- 20 Mtr. 49 Speed:- A ) Hoisting -0-3M / Min 50 B ) Cross Travel- 0-15M / Min 51 C ) Long Travel - Motorized 52 Motors:- All Motors Are Sq, Cage., Crane Duty, 40% Cdf, Ip-55, 150 St. / Hr., Cl. B / F Insulation, Foot Mounted Of Bbl / Crompton / Hindustan Make As Per Is:325. 53 A ) Hosting - 3.0Hp Sq Cage 54 B ) Cross Travel - 0.5Hp Sq Cage X 1Nos. 55 C ) Long Travel - 1 Hp Sq Cage 56 Brake:- A ) Hoisting - Dc Disc Type 57 B ) Cross Travel - Dc Disc Type 58 C ) Long Travel - Dc Disc Type 59 Limit Switch Shall Be Provided For All Motion. 60 Gears :- A ) Hoisting - Hardened, Horizontal, Helical, Splash Lubricated 61 B ) Cross Travel - Premium / Hindustan Make Gear Box With Warm Gear / Bonifilioli 62 Ct Wheel - Dia 190Mmx100, 22208 L Block 63 C ) Long Travel - Premium / Hindustan Make Gear Box With Warm Gear / Bonifilioli 64 Power Supply :- 415 Volts + / - 10%, 3 Phase 50 C / S Ac 65 Control Voltage- 110 Volts 66 Control Panel :- All Contactor / Overload Relays Push Button Station Etc. Shall Be Operated Make Like Siemens / Schneider 67 Wire Rope :- Usha Martein Make 12 Mm / 6X36 Fmc, Fiber Core180 Kg / Mm Sq. As Per Is :2266 68 No. Of Fall:- 4 Falls 69 Hook :- With Thrust Bearing Plain Shank Type As Per Is:3815 / 4637 / 70 Rope Drum :- Seamless Pipe 71 Lt Wheel Size. :- 250 Dia With 90 Width 72 Lt Rail Recommended:- 40X40 Square Rail 73 Plat Form:- Small Size Platform Will Be Provided In Lt Side For Maint. Purpose. 74 Operation:- Pendent Controlled 75 Painting:- Golden Yellow Synthetic Enamel / Dark Blue / Navy Blue. 76 Notes :1 ) Rate Are Demmed To Be Included For Testing At Site By Oem / Contractor In Presence Of User, Je E / M, Age E / M, And Ge, Also Realease Of Payment Will Be Restricted As 10 % Or As Certain Percentage Decided By Ge. After Satisfactory Testing Full Payment Will Be Release. Precommisioning Test Will Be Carrired Out At Manufacturer Permisses / Companyas Per Is.2 ) Oem / Contractorshall Provide Drawing For Gridder Foundation, To Be Fabrication At Time Of Vehicle Shederrection.3 ) Gallentry Portion For Long Travell ( Forward & Backward ) Of Eot Crane Is Considered In The B / R -I Portion For Excution4 ) Oem Shall Prvide Drawings For Grider Foundation, To Be Fabrication At Time Of Serviceable Shed.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 29-Sep-2023 CorrigendumNo.01 Date 18-10-2023
2 09-Oct-2023 CorrigendumNo.02 Date 26-10-2023
3 14-Oct-2023 CorrigendumNo.03 Date 03-11-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 87000.0 /-
Tender Value
INR 43.50 Lakhs /-

BOQ Items

Name of work :- PROVN OF REPAIR SHED FOR ‘C’ VEH WITH HARD STANDING WITH 2 TON TRAVELLING TROLLEY AT FD WKSP COY IN ARMY AREA UNDER GE (ARMY) NO. 01 JODHPUR
Sl. No. Item Description
1Surface excavation not exceeding 30cm and averaging 15 cm deep and getting out in any type of soil complete all as specified and as directed.
2M&L for hardcore of gaugeexceeding 63 mm but not exceeding 100 mm of brokenstone or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface, compaction and consolidation with power roller, complete all as specified and as directed.
3Excavation in post holes each not exceeding 0.5 cu.m, getting out in any type of soil, including returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm thick, watering and removing surplus soil to a distance not exceeding 50m and making good surface complete all as specified and as directed.
4M&L cement concrete 1:3:6 type C-1 by using 20mm graded crushed stone aggregate as in foundation, filling, mass concrete, embedded concrete for fencing post hole, including necessary form work complete all as specified and as directed.
5S&F steel work in tubular trusses including special shaped washers etc complete using ERW or induction butt welded tubes confirming to IS:1161-1979 Grade St-240 complete all as specified and as directed.
6M&L for mild steel work confirming to Fe - 410, Grade E-250 , Quality-A, as in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. etc complete all as specified and as directed.
7S&F plates (plain or /mdsplate chequered) channels square cut or notched (ordinary and counter sunk) forming holes with riveted bolted or welding attachement
8M & L for preparing new steel surfacesof any descriptionexc 10 cm in width, priming with red oxide and applied two coat of synthetic enamel paint complete all as specified and directed.
9S&F prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws all as specified and as directed.
10M&L 100 mm thick PCC 1:4:8 type D2 using 40mm graded crushed stone aggregate for sub base as in floor complete all as specified and as directed .
11M & L for Cement concrete work in pavement / hard - standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement per cubic metre, thickness of concrete 25 cm or less complete all as specified and directed
12Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out any type of soil all as speicfied and directed.
13M&L PCC 1:4:8 type D2 by using 40mm graded stone aggregate as in foundations filling and mass concrete complete all as specified and directed.
14M&L for squarred rubble walling Jodhpur type regular coursed well bonded ,bedded and solidly hearted built in cement mortar 1:6 complate all as specified and directed.
15Extra over squared rubble stone walling Jodhpur type regular course for hammer dressing to face of stone with max depression on face from a straight edge not exc 20mm and dressing complete to squared rubble walling, regular coursed, Jodhpur typeall as specified and directed.
16M&L for Keyed pointing to square rubble masonryJodhpur type regular course in CM 1:3 all as specified.
17M&L for preparation of new plastered or un-plastered surfaces of walls and applying two coats of cement base paint over a coat of chalk white, complete all as specified and as directed.
18M&L for PCC 1:2:4 type B1 Mix using 20mm graded stone aggregate as in hold fast iron fixing,coping, chamfered edgesincluding necessary form work all asspecified.
19Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point all as specified and directed.
20Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. all as specified and directed.
21S&F Expanded metal,N exc 4 kg cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members
22Supply and lay in trenches/on wall/on pole/in duct /through protection pipe, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables heavy duty LT cable, 1100 volts grade with aluminium conductor cross sectional area16 Sqmm 4 core size including retrieving/taking out/taking down old unserviceable cable from duct/trenches/pipes/pole/wall etc. including brick cover and protection pipe and disconnecting the connections. Note:-Excavation andearth work, sand cushioning,PCC cable cover and protection pipe etc. shall be measured and paid for separately.
23M&L for dry clean fine river sand as in sand cushioningto underground cable including punning down ofsand layer all as specified and directed. Note :- Punnedthickness shall only be measured and paid.
24Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1, flat, size 250x150mm x40 mm
25M&L for galvanised steel tubing, light grade, for protection of cable, laid in trenches/road crossing/floor or fixed to pole/wall with all fittings, of size 40 mm bore.
26M & L for surface point wiring complete with multistranded copper conductor 1.5 Sqmm PVC insulated unsheathed single core FRLSH cable 1100 volt grade, confirming IS 694 & colour code in conduit system of wiring,drawn through in and includingnon-metalicPVCsurface conduit of size 20/25 mm or med grade as required as site, totallysurface for floors / ceiling or fixed on surface of walls / columns / beam / tie beam etc by means of saddles and clips etc incl all conduit accessories / fittings such as tee/ elbow / sockets / junction boxes / inspection covers etc of heavy grade, ISI marked and surface PVC gang box.Wodden Box for mounting switch and sockets , for mounting of switches, sockets fan regulators etc incl 1.5 Sqmm FRLSH PVC insulated, unsheathed flexible multi stranded copper conductor cables as continuous earth wire connected to metallic bodies of luminaries / fans etc at one end and to common earth dolly at other end, suitable for One light/fan point controlled by one, one wayswitch, complete all as specified and directed.
27All as per item No 26.00 here-in-above but with 2.5 Sq mm single core multistanded copper conductor cable for 3 pin 16 Amp socket outlet on independent board .
28S&F socket outlet 2 in 1, 6 pin, 6 and 16 amp flush type, 230 Volts,ISI Marked complete all as specified and directed.
29S&F switch piano flush type single pole one way 16 Amp, 230 Volts, ISI Marked complete all as specified and directed.
30S&F Switch piano type, single pole, one way, 5/6 amps, 230 volts,ISI Marked complete all as specified and directed.
31S&F Ceiling rose,three terminals, bakelite body, 230 volts, ISI Marked complete all as specified and directed.
32Supply and fixing as MCB DB SPN (double door) 4 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wallall as specified and directed by the Engr-in-Charge.
33S&F MCB, B Curve type, 10 kA, 6 to 40Amp, SPN with over load and short circuit protection, ISI Marked complete all as directed.
34S&F MCB, B Curve type, 10 kA, 6 to 32 Amp, Single Pole with over load and short circuit protection, ISI Marked complete all as directed.
35Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp
36S&F Bldg security LEDLight Luminaire of 35 Watts having IP 65 protection fiting made out of pressure die cast Aluminium housing, operating Voltage 140-270 Volts with in built surge protectore, toughened glass with and including Sutaible size ofGI Bracket including drilling holes, nuts & bolts 2 coats of red oxide primer on GI pipe and fixing with wall security light on building wall connecting cable complete all as directed.
37S&F air circulator wall fans 230 V single phase oscillating 450 mm sweep , copper winding, Heavy duty motor,suitable for wall /pole/pipe /piller mounting all as directed.
38S & Fsub main wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade of size 4 Sqmm and one run of 4 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead duly coneected with earth dolly drawn through in and includingnon metallic PVC conduit of size 25 mm dia (external) with wall thickness not less than 1.8 mm, ISI marked Surface on wall includingaccessories like bends, tees junction boxes, etc fixed in wall or ceiling etc. complete as directed by Engineer-in-Charge.NOTE: Two runs of cable with one run of earth wire and PVC conduit shall be measured & paid for as one length.
39Materials and labour for earthingcomplete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip of size 25 x 4mmby means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed by the Engr-in-Charge.Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead.
40S&Fand testing factory made sheet metal enclosurefor MCB DB TPN 4 way 415 volt with double door, IP - 43 protectionduly withfixed in wall/ concealed in wall /Surface on wall/pile/piller complete and making good disturbed surfaces of wall, floor etc including electric wire connectionall as directedby Engineer-in-Charge.
41S&F MCB TPN, "C" Curve type ,415 Volts, 32 Amps with over load and short circuit protection, ISI Marked complete all as directed.
42Supply, install ,Erection, testing and commissioning EOT crane 2 ton capacity Comprising following and Notes and Precommissioning factory test as per IS complete all as directed by EIC
43Type: Single girder EOT crane
44SWL- 2T
45Class & Duty- Class II as per IS: 3177 & 807.
46Span- 9 Mtr. Approx.
47Height of lift - 5 Mtr.
48Bay Length- 20 Mtr.
49Speed:- a) Hoisting -0-3m/min
50b) Cross Travel- 0-15m/min
51C) Long Travel - motorized
52Motors:- All Motors are sq,Cage., crane duty, 40% CDF, IP-55, 150 St./hr., Cl. B/F insulation, foot mounted of BBL/Crompton/Hindustan make as per IS:325.
53a) Hosting - 3.0Hp Sq cage
54b) Cross Travel - 0.5Hp Sq cage x 1nos.
55C) Long Travel - 1 hp Sq cage
56Brake:- a) Hoisting - Dc Disc Type
57b) Cross Travel - Dc Disc Type
58C) Long Travel - Dc Disc Type
59Limit Switch shall be provided for all motion.
60Gears :- a) Hoisting - Hardened, Horizontal, Helical, Splash Lubricated
61b) Cross Travel - Premium/ Hindustan Make Gear Box with warm Gear/ Bonifilioli
62Ct wheel - dia 190mmx100,22208 L block
63C) Long Travel - Premium/ Hindustan Make Gear Box with warm Gear/ Bonifilioli
64Power Supply :- 415 Volts +/- 10%, 3 Phase 50 C/S AC
65Control Voltage- 110 volts
66Control Panel :- All contactor / overload relays Push button station etc. shall be operated Make like Siemens/Schneider
67Wire Rope :- USHA MARTEIN MAKE 12 mm / 6x36 FMC, Fiber core180 kg/ MM Sq. As per IS :2266
68No. of Fall:- 4 Falls
69Hook :- With Thrust Bearing Plain shank Type as per IS:3815/4637/
70Rope Drum :- seamless pipe
71LT Wheel Size. :- 250 dia with 90 width
72LT Rail Recommended:- 40x40 square rail
73Plat Form:- Small Size Platform will be provided in Lt side for Maint. Purpose.
74Operation:- Pendent Controlled
75Painting:- Golden Yellow Synthetic Enamel/ dark blue /navy blue.
76Notes :1) Rate are demmed to be included for testing at site by OEM/Contractor in presence of User, JE E/M, AGE E/M, and GE, also realease of payment will be restricted as 10 % or as certain percentage decided by GE. After satisfactory Testing full payment will be release. Precommisioning test will be carrired out at manufacturer permisses/companyas per IS. 2) OEM/Contractorshall provide drawing for gridder foundation, to be fabrication at time of Vehicle shederrection. 3) Gallentry portion for long travell (Forward & Backward ) of EOT crane is considered in the B/R -I portion for excution 4) OEM shall prvide drawings for grider foundation, to be fabrication at time of serviceable shed.