}

Tender For Electrical Works Related To The Installation Of Ac Units In Accounts Section, Engineering Wing And Training Section, Thiruvananthapuram-Kerala

Kerala Tourism Development Corporation has published Tender For Electrical Works Related To The Installation Of Ac Units In Accounts Section, Engineering Wing And Training Section. Submission Date for this Tender is 25-09-2023. Electrical Maintenance Tenders in Thiruvananthapuram Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

39766611
Tender For Electrical Works Related To The Installation Of Ac Units In Accounts Section, Engineering Wing And Training Section
Open Tender
Indian
Kerala
Thiruvananthapuram
25-09-2023

Tender Details

Tender For Electrical Works Related To The Installation Of Ac Units In Accounts Section, Engineering Wing And Training Section Wiring for light point fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable Gi box and earthing the point with 15 sq mm FRLSPVC insulated copper- conductor single core cable etc as required Group B Wiring for circuit submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 48q, mm+1x4 Sq mm earth wire. Wiring for circuit submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 4X4 sq. mm+1 X 4 sq. mm earth wire Supplying and fixing of following ways surface recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCTIs (hutwithout MCBs and incomer) as required (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required 14 way (4+12), Double door Supplying and fixing 5 amps to 32 amps rating, 240/415 volu, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Triple pole Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required, 40 Amps Supplying and fixing following rating, four pole, 415 volts, polator in the existing MCH DB complete with connections, testing and commissioning etc, as required Supplying and fixing following rating, four pole, three phase and neutral), 415 volts, residual curren 300 mA in the existing MCB DB complete with connections, testing and commissioning etc. as circuit breaker (RCCB), having a sensitivity current required 63 amps Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable. 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages, colour washing etc. as required. 3.5 core 35 sq mm with factory made clamp Supply and drawing hare earthing conductors of the following sizes along with wiring cables and giving connection as required 3.15 mm copper conductor Supply of superior quality copper earth socket for the following size of earth conductor including crimping c. as required 3.15(10 SWG) Supplying and making end termination with brass compression gland and aluminio lugs for following size of PVC insulated and PVC sheattied XLPE aluminium conductor cable of 11 KV grade as required 3 1/2X 15 sq. m (32mm) Supplying and fixing of following sizes of mednom class PVC conduit along with accessories in surface recess including cutting the wall and making good the same in case of recessed conduit as required. 20 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface recess including cutting the wall and making good the same in case of recessed conduit as required 25 mm Supply & Fixing the following types/szes of boxes suitable for modular accessories in surface recess including making good the damages, colour washing es as required (RoHS compliant 13 module moulded plastic box on surface Supply and Fixing the following modalar switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant) 25A SP switch with indicator Supply and Fixing the following modalar switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant) 25A 3pin Shuttered socket Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 15/16 amp switch Supplying and fixing following modular switch) socket on the existing modular plate & switch bux including connections but excluding modular plate etc as required. 6pin 15/16 amp socket outlet Supplying and fixing following size modules, Gl bax alongwith modular base & cover plate for modular switches in recess es as required. 3 Module (100X75mm)

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail