Tender For Providing Electrical Installations & Fans For Bsnl Mini Data Centre At Rail Head Building , Trikuta Nagar, Jammu., Jammu-Jammu And Kashmir

Bharat Sanchar Nigam Limited-BSNL has published Tender For Providing Electrical Installations & Fans For Bsnl Mini Data Centre At Rail Head Building , Trikuta Nagar, Jammu.. Submission Date for this Tender is 04-10-2023. Absorbents Tenders in Jammu Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

39762445
Tender For Providing Electrical Installations & Fans For Bsnl Mini Data Centre At Rail Head Building , Trikuta Nagar, Jammu.
Open Tender
Indian
Jammu And Kashmir
Jammu
04-10-2023

Tender Details

Tender For Providing Electrical Installations & Fans For Bsnl Mini Data Centre At Rail Head Building , Trikuta Nagar, Jammu.; 1 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required: Group -C 2 Wiring For Light / Power Plug With 2X4 Sqmm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessedsteel Conduit Alongwith 1 No 4 Sqmm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. 3 Wiring For Light / Power Plug With 4X4 Sqmm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessedsteel Conduit Alongwith 2 No 4 Sqmm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. 4 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With 2X1.5Sqmm + 1X1.5Sqmm Earth Wireof Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required. 5 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With 2X2.5Sqmm + 1X2.5Sqmm Earth Wireof Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required. 6 Supplying & Drawing Following6x1.5 Sqmm Frls Pvc Insulated Copper Conductor Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 7 Supplying And Fixing Of 20 Mm Steel Conduit Along With Accessories In Surface / Recess Including Painting In Case Of Surface Conduit, Or Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 8 Supplying And Fixing Of 25 Mm Steel Conduit Along With Accessories In Surface / Recess Including Painting In Case Of Surface Conduit, Or Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 9 Supplying And Fixing Of 32 Mm Steel Conduit Along With Accessories In Surface / Recess Including Painting In Case Of Surface Conduit, Or Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.: 10 Supplying And Fixing Of 5 / 6 A Modular Switch On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required 11 Supplying And Fixing Of 15 / 16 A Modular Switch On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required 12 Supplying And Fixing Of 3 Pin 5 / 6 A Modular Socket Outleton The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required 13 Supplying And Fixing Of6 Pin 15 / 16 A Modular Socket Outleton The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required 14 Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 15 Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate & Switch Box Excluding Modular Plate As Required. 16 Supplying And Fixing Of 2 Module ( 75Mmx75mm ) , Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required 17 Supplying And Fixing Of 4 Module ( 125Mmx75mm ) , Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required 18 Supplying And Fixing Of 6 Module ( 200Mmx75mm ) , Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required 19 Supplying And Fixing Of 8 Module ( 125Mmx125mm ) , Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required 20 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 3 Pin 5 / 6 Amps Modular Socket Outlet And 5 / 6 Amps Modular Switch, Connection Etc. As Required. 21 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 3 Pin 15 / 16 Amps Modular Socket Outlet And 15 / 16 Amps Modular Switch, Connection Etc. As Required. 22 Supplying And Fixing Brass Batten / Angle Holder Including Connection Etc As Required 23 Supplying And Fixing12- Way , Double Doorsingle Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 24 Supplying And Fixing 5 A To 32 A Rating, Single Pole, 240 / 415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Loadin The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 25 Supplying And Fixing 5 A To 32 A Rating, Double Pole, 240 / 415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 26 Supplying And Fixing 5 A To 32 A Rating, Triple Pole, 415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 27 Supplying And Fixing 5 A To 32 A Rating, Tp&N, 415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 28 Supplying And Fixing Dp Sheet Steel Enclosure On Surface / Recess Along With 25 / 32 A 240 V C Curve Dp Mcb Complete With Connections, Testing And Commissioning Etc. As Required. 29 Supplying And Installing 300 Mm Width X 50 Mm Depth X 1.6 Mm Thickness Size Of Perforated Hot Dipped Galvanised Iron Cable Tray ( Galvenisation Thickness Not Less Than 50 Microns ) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I Bolts & Nuts Etc. As Required. 30 Supplying And Installing 375 Mm Width X 50 Mm Depth X 2.0 Mm Thickness Size Of Perforated Hot Dipped Galvanised Iron Cable Tray ( Galvenisation Thickness Not Less Than 50 Microns ) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I Bolts & Nuts Etc. As Required. 31 Supplying And Installing 450 Mm Width X 50 Mm Depth X 2.0 Mm Thickness Size Of Perforated Hot Dipped Galvanised Iron Cable Tray ( Galvenisation Thickness Not Less Than 50 Microns ) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I Bolts & Nuts Etc. As Required. 32 Earthing With Copper Earth Plate 600 Mm X 600 Mm X 3 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal / Coke And Salt As Required. 33 Supplying And Laying 25 Mm X 5 Mm Copper Strip At 0.50 Metre Below Ground As Strip Earth Electrode, Including Connection / Terminating With G.I. Nut, Bolt, Spring, Washer Etc. As Required. ( Jointing Shall Be Done By Overlapping And With 2 Sets Of Brass Nut Bolt & Spring Washer Spaced At 50Mm ) 34 Providing And Fixing 25 Mm X 5 Mm Copper Strip In 40 Mm Dia G.I. Pipe From Earth Electrode Including Connection With Brass Nut, Bolt, Spring, Washer Excavation And Re-Filling Etc. As Required. 35 Providing And Fixing 25 Mm X 5 Mm Copper Strip On Surface Or In Recess For Connections Etc. As Required. 36 Providing And Fixing 25 Mm X 5 Mm G.I. Strip On Surface Or In Recess For Connections Etc. As Required. 37 Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface / Recessed Conduit / Submain Wiring / Cable As Required. 38 Providing And Fixing 4.0 Mm Dia Copper Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface / Recessed Conduit / Submain Wiring / Cable As Required. 39 Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Masonary Open Duct As Required. 40 Upto 35 Sq. Mm ( Clamped With 1Mm Thick Saddle ) 41 Above 35 Sqmm And Upto 95 Sq. Mm ( Clamped With 25X3mm Ms Flat Clamp ) 42 Above 95 Sqmm And Upto 185 Sq. Mm ( Clamped With 25 / 40X3mm Ms Flat Clamp ) 43 Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size On Wall Surface As Required. 44 Upto 35 Sq. Mm ( Clamped With 1Mm Thick Saddle ) 45 Above 35 Sqmm And Upto 95 Sq. Mm ( Clamped With 25X3mm Ms Flat Clamp ) 46 Above 95 Sqmm And Upto 185 Sq. Mm ( Clamped With 25 / 40X3mm Ms Flat Clamp ) 47 Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size On Cable Tray As Required. 48 Upto 35 Sq. Mm ( Clamped With 1Mm Thick Saddle ) 49 Above 35 Sqmm And Upto 95 Sq. Mm ( Clamped With 25X3mm Ms Flat Clamp ) 50 Above 95 Sqmm And Upto 185 Sq. Mm ( Clamped With 25 / 40X3mm Ms Flat Clamp ) 51 Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. 52 3½ X 35 Sq. Mm ( 32Mm ) 53 3½ X 50 Sq. Mm ( 38Mm ) 54 3½ X 120 Sq. Mm ( 45Mm ) 55 Supplying And Fixing 48 ( 1200Mm ) Sweep Ceiling Fan Suitable For Operation On230 Voltsingle Phase Ac Supply I / C Connections With Suitable Sixe Of Pvc Insulated Copper Cable Etc Complete As Required ( Super Speed Es Of M / S Havellsmake Or Similar Superior Model Of Crompton / Usha / Ortem / Khaitan Make ) . 56 Supplying And Fixing 16 ( 400Mm ) Sweep Wall Mounted Oscillating Type Fanhaving 3 Speed Regulator I / C All Accessories Suitable For 230 Volt Ac Single Phase Supply I / C Connections Etc Complete As Required ( M / S Swing Of Havells Make Or Similar Superior Model Of Crompton / Usha / Ortem / Khaitan Make ) . 57 Sitc Of 600Mm X 600Mm Size Surface Type Prewired 36 W Ledfittingcomplete With All Accessories Etc.Directly On Ceiling Complete With All Accessoriesetc. I / C Connections With 1.5 Sq.Mm. Frlspvc Insulated Copper Conductor, Single Core Cable And Earthing Etc. As Reqd. ( Crompton Polaris Nio Iii Or Similar Model Of Superior Make ) 58 Sitc Of 4 Feet Long 20 W Led Batten Type Fitting Complete With All Accessories Etc. Directly On Ceiling / Wall I / C Connections With 1.5 Sq.Mm. Frlspvc Insulated Copper Conductor, Single Core Cable And Earthing Etc. As Reqd. ( Trim Linea Neu Of Crompton Make Or Similar Model Of Superior Make ) 59 Supplying & Laying Of Xlpe Insulated4 X 16 Sqmm Size Copper Conductor Pvc Sheathed Unarmoured Cable Conforming To Is 7098 Part I Complete As Per Specification Including Laying Onsurface / Wall / Cable Tray With Suitable Saddle And Cleat / Clamp Arrangementas Required. 60 Supplying & Laying Of Xlpe Insulated4 X 10 Sqmm Size Copper Conductor Pvc Sheathed Unarmoured Cable Conforming To Is 7098 Part I Complete As Per Specification Including Laying Onsurface / Wall / Cable Tray With Suitable Saddle And Cleat / Clamp Arrangement As Required. 61 Supplying & Laying Of Xlpe Insulated3 X 6 Sqmm Size Copper Conductor Pvc Sheathed Unarmoured Cable Conforming To Is 7098 Part I Complete As Per Specification Including Laying Onsurface / Wall / Cable Tray With Suitable Saddle And Cleat / Clamp Arrangement As Required. 62 Supplying & Laying Of Xlpe Insulated3 X 2.5 Sqmm Size Copper Conductor Pvc Sheathed Unarmoured Cable Conforming To Is 7098 Part I Complete As Per Specification Including Laying Onsurface / Wall / Cable Tray With Suitable Saddle And Cleat / Clamp Arrangement As Required. 63 Supplying And Laying 6Mm Thick Rubber Matting With Isi Mark Of Size Suitable For Lv Supply ( Isi Mark ) Etc. Complete As Required. 64 Sitc Of Heavy Duty Exhaust Fan Of 450 Mm Sweep, 1400 Rpm Speed Suitable For Operation Nf 240 Volts, 50 Hzsingle Phase Ac Supply Complete With Installation On Duct Including Making Suitable Arrangement For Fixing In Existing Ac Duct Complete With Connections Etc As Required ( Model :Turbo Force Neo 1P Of Havells Or Similar Model Of Superior Make ) 65 Supplying & Fixing400 A 35 Ka Fp Mccb, Ics=100% Icu With Adjustable Overload Andshort Circuit Settings , Thermal Release Range Of ( 320-400A ) With Spreader Terminals , Rotary Handle In The Existing Mv Panel Including Dismantling The Life Expired Tpn Sfus, Providing Suitable Structural Modification To The Cubicleand Door To Fix New Mccb With Minimum Shut Down Etc Complete As Reqd 66 Supplying & Fixing 250 A, 35 Ka Fp Mccb, Ics=100% Icu With Adjustable Overload Andshort Circuit Settings , Thermal Release Range Of ( 200-250A ) With Spreader Terminals , Rotary Handle In The Existing Mv Panel Including Dismantling The Life Expired Tpn Sfus, Providing Suitable Structural Modification To The Cubicleand Door To Fix New Mccb With Minimum Shut Down Etc Complete As Reqd 67 Supplying And Fixing 4 Way Vertical Type Tpn ( 4+4+4 ) Double Door, Sheet Steel, Mcb Distribution Board, 415 Volts, On Surface / Recess, Complete With Metal Door, Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Paintedi / Cfour Pole 100 A, 25 Ka ( 80-100 ) A Adjustable Mccbas Incomer Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) ( Incomer Mccb M / S L&T Make Model Dn0-100C Or Equivalent Similar Superior Make ) 68 Supplying, Installing, Balancing And Commissioning Of Rectangular / Round Ducting Suitable For Package Typeair Conditioning Plant Fabricated At Site With Galvanized Steel Sheetof 22 Gauge Thickness Compelete With Neoprene Rubber Gaskets, Elbows, Splitter, Dampers, Vanes, Hangers, Supports Etc. As Per Approved Drawing And Specifications Complete As Required. 69 Supplyingof One Numberxlpe Insulatedpvc Inner Sheathedaluminium Conductorarmouredcable Of 1100Vgradeconforming To Is: 7098 ( Part 1 ) 1988 With Opto Date Amendmentsof Following Size Etc As Required. 70 3.5 X120 Sq.Mm. Aluminium Conductor Armouredcable 71 3.5 X50 Sq.Mm. Aluminium Conductor Armouredcable 72 3.5 X35 Sq.Mm. Aluminium Conductor Armouredcable 73 Power Room Panel :-Supply, Installation, Testing And Commissioning Of Cubicle Type Lt Panel Suitable For 415 V, 3 Phase , 4 Wire 50 Hz Ac Supply System , Fabricated In Compartmentalised Design From Crca Sheet Steel Of 2Mm Thick For Frame Work And Covers, 3Mm Thick For Gland Plates I / C Cleaning And Finishing Complete With Powder Coating In Approved Shade, Havingmin. 500 Amps Capacity, Extensible Type Tpn Aluminium Alloy Busbars Of High Conductivity, Dmc / Smc Busbar Supports With Short Circuit Withstand Capacity Of 31Mva For 1 Sec, Bottom Base Channel Of Ms Section Not Less Than 100Mm X 50Mm X 5 Mm Thick, Lifting Hooks, Fabrication Shall Be Done In Transportable Sections, Entire Panel Shall Have Common Copper Earth Bar Of Size 25Mm X 5Mm At The Rear With 2 Nos. Earth Stud, Solid Connections From Main Bus Bars To Switch Gears With Required Size Of Aluminium Bus Bars And Control Wiring With 1.5 Sqmm Pvc Insulated Copper Conductor Cable, Cable Alleys, Cable Gland Plates In Two Halfi / C Providing Following Switchgears, Transporting From Factory To Site, Unloading, Leading Etc As Required .A ) Incoming:I ) 320 A , 35 Ka Fp Mccb, Ics=100% Icu With Adjustable Overload Andshort Circuit Settings, Thermal Release Range Of ( 250-320A ) With Spreader Terminals , Rotary Handle And Castle Key Interlock- 2 Nos.The Castle Key Interlock Shall Be Provided In The Incomers To Ensure That One Supply Is Available At A Time On Each Section Of Bus And To Eliminate Any Possibility Of Accidently Approaching Two Supplies At One Bus Section.Ii ) Digital Type Multifunction Meter Capable To Measure Parameters Likev, A, F, Pf, Kw, Kva, Old Energy, On And Run Hours, Site Selectablekwh / Kvahwith Rs 485 Portclass 0.5- 2 Nos.Iii ) Cts- Ratio 400 / 5A 15Va Cl-0.5 - 6 Nos. Iv ) Ryb Phase Indicating Led Lamps With Toggle Switch & Mcb - 2 Set.B ) Busbar:I ) Tpnaluminium Busbars Of Min 500Amps Capacity With Heat Shrinkable Coloured Sleeves And I / Cdmc / Smc Busbarcross Section, Size Supportsand Their Spacing Etc For Withstanding Faultlevel Of 31Mva For 1 Sec.C ) Outgoings:I ) 160 A, 35 Ka 4Pmccb, Ics=100% I Cu, With Adjustable Overload Andshort Circuit Settingswith Thermal Release Range Of ( 125-160 A ) , Spreader Terminals , Rotary Handle Etc - 3 Nos.Ii ) 63 A , 35 Ka4p Mccb, Ics=100% I Cu With Adjustable Overload Andshort Circuit Settingswith Thermal Release Range Of ( 40--63 A ) With Spreader Terminals , Rotary Handle Etc -3 Nos.Complete As Above Note : The Panel Drawing Shall Be Got Approved From The Engineer In Charge Before Fabrication . 74 Ac Room Panel:- Supply, Installation, Testing And Commissioning Of Cubicle Type Lt Panel Suitable For 415 V, 3 Phase , 4 Wire 50 Hz Ac Supply System , Fabricated In Compartmentalised Design From Crca Sheet Steel Of 2Mm Thick For Frame Work And Covers, 3Mm Thick For Gland Plates I / C Cleaning And Finishing Complete With Powder Coating In Approved Shade, Havingmin. 300 Amps Capacity, Extensible Type Tpn Aluminium Alloy Busbars Of High Conductivity, Dmc / Smc Busbar Supports With Short Circuit Withstand Capacity Of 31Mva For 1 Sec, Bottom Base Channel Of Ms Section Not Less Than 100Mm X 50Mm X 5 Mm Thick, Lifting Hooks, Fabrication Shall Be Done In Transportable Sections, Entire Panel Shall Have Common Copper Earth Bar Of Size 25Mm X 5Mm At The Rear With 2 Nos. Earth Stud, Solid Connections From Main Bus Bars To Switch Gears With Required Size Of Aluminium Bus Bars And Control Wiring With 1.5 Sqmm Pvc Insulated Copper Conductor Cable, Cable Alleys, Cable Gland Plates In Two Halfi / C Providing Following Switchgears, Transporting From Factory To Site, Unloading, Leading Etc As Required .A ) Incoming:I ) 250 A 36Ka Fp Mccb, Ics=100% Icu With Adjustable Overload Andshort Circuit Settings, Thermal Release Range Of ( 200-250A ) With Spreader Terminals , Rotary Handle And Castle Key Interlock- 2 Nos.The Castle Key Interlock Shall Be Provided In The Incomers To Ensure That One Supply Is Available At A Time On Each Section Of Bus And To Eliminate Any Possibility Of Accidently Approaching Two Supplies At One Bus Section.Ii ) Digital Type Multifunction Meter Capable To Measure Parameters Likev, A, F, Pf, Kw, Kva, Old Energy, On And Run Hours, Site Selectablekwh / Kvahwith Rs 485 Portclass 0.5- 2 Nos.Iii ) Cts- Ratio 300 / 5A 15Va Cl-0.5 - 6 Nos. Iv ) Ryb Phase Indicating Led Lamps With Toggle Switch & Mcb - 2 Set.B ) Busbar:I ) Tpnaluminium Busbars Of Min 300Amps Capacity With Heat Shrinkable Coloured Sleeves And I / Cdmc / Smc Busbarcross Section, Size Supportsand Their Spacing Etc For Withstanding Faultlevel Of 31Mva For 1 Sec.C ) Outgoings:I ) 100 A, 36 Ka 4Pmccb, Ics=100% I Cu, With Adjustable Overload Andshort Circuit Settingswith Thermal Release Range Of ( 67-100 A ) , Spreader Terminals , Rotary Handle Etc - 6 Nos.Complete As Above Note : The Panel Drawing Shall Be Got Approved From The Engineer In Charge Before Fabrication.

Key Value

Document Fees
INR 590 /-
EMD
INR 37164.0 /-
Tender Value
INR 18.58 Lakhs /-

BOQ Items

Name of Work: Providing Electrical Installations & Fans for BSNL Mini Data Centre at Rail Head building , Trikuta Nagar, Jammu.
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required: Group -C
2Wiring for light / power plug with 2x4 sqmm FRLS PVC insulated copper conductor single core cable in surface /recessedsteel conduit alongwith 1 No 4 sqmm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
3Wiring for light / power plug with 4x4 sqmm FRLS PVC insulated copper conductor single core cable in surface / recessedsteel conduit alongwith 2 No 4 sqmm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
4Wiring for circuit / submain wiring alongwith earth wire with 2X1.5sqmm + 1X1.5sqmm earth wireof FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit as required.
5Wiring for circuit / submain wiring alongwith earth wire with 2X2.5sqmm + 1X2.5sqmm earth wireof FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit as required.
6Supplying & drawing following6X1.5 sqmm FRLS PVC insulated copper conductor single core cable in the existing surface / recessed steel / PVC conduit as required.
7Supplying and fixing of 20 mm steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
8Supplying and fixing of 25 mm steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
9Supplying and fixing of 32 mm steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.:
10Supplying and fixing of 5/6 A modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required
11Supplying and fixing of 15/16 A modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required
12Supplying and fixing of 3 pin 5/6 A modular socket outleton the existing modular plate & switch box including connections but excluding modular plate etc. as required
13Supplying and fixing of6 pin 15/16 A modular socket outleton the existing modular plate & switch box including connections but excluding modular plate etc. as required
14Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
15Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
16Supplying and fixing of 2 Module (75mmX75mm), GI box alongwith modular base & cover plate for modular switches in recess etc. as required
17Supplying and fixing of 4 Module (125mmX75mm), GI box alongwith modular base & cover plate for modular switches in recess etc. as required
18Supplying and fixing of 6 Module (200mmX75mm), GI box alongwith modular base & cover plate for modular switches in recess etc. as required
19Supplying and fixing of 8 Module (125mmX125mm), GI box alongwith modular base & cover plate for modular switches in recess etc. as required
20Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
21Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
22Supplying and fixing brass batten/ angle holder including connection etc as required
23Supplying and fixing12- way , Double doorsingle pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
24Supplying and fixing 5 A to 32 A rating,Single pole, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loadin the existing MCB DB complete with connections, testing and commissioning etc. as required.
25Supplying and fixing 5 A to 32 A rating,Double Pole, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required.
26Supplying and fixing 5 A to 32 A rating,triple Pole,415 volts, "C" curve, miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required.
27Supplying and fixing 5 A to 32 A rating,TP&N,415 volts, "C" curve, miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required.
28Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
29Supplying and installing 300 mm width X 50 mm depth X 1.6 mm thickness size of perforated Hot Dipped Galvanised Iron cable tray (Galvenisation thickness not less than 50 microns)with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I bolts & nuts etc. as required.
30Supplying and installing 375 mm width X 50 mm depth X 2.0 mm thickness size of perforated Hot Dipped Galvanised Iron cable tray (Galvenisation thickness not less than 50 microns)with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I bolts & nuts etc. as required.
31Supplying and installing 450 mm width X 50 mm depth X 2.0 mm thickness size of perforated Hot Dipped Galvanised Iron cable tray (Galvenisation thickness not less than 50 microns)with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I bolts & nuts etc. as required.
32Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
33Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
34Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut,bolt, spring, washer excavation and re-filling etc. as required.
35Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
36Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
37Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
38Providing and fixing 4.0 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
39Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonary open duct as required.
40Upto 35 sq. mm (clamped with 1mm thick saddle)
41Above 35 Sqmm and Upto 95 sq. mm (Clamped with 25x3mm MS flat clamp)
42Above 95 Sqmm and Upto 185 sq. mm (Clamped with 25/40x3mm MS flat clamp)
43Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
44Upto 35 sq. mm (clamped with 1mm thick saddle)
45Above 35 Sqmm and Upto 95 sq. mm (Clamped with 25x3mm MS flat clamp)
46Above 95 Sqmm and Upto 185 sq. mm (Clamped with 25/40x3mm MS flat clamp)
47Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
48Upto 35 sq. mm (clamped with 1mm thick saddle)
49Above 35 Sqmm and Upto 95 sq. mm (Clamped with 25x3mm MS flat clamp)
50Above 95 Sqmm and Upto 185 sq. mm (Clamped with 25/40x3mm MS flat clamp)
51Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
523½ X 35 sq. mm (32mm)
533½ X 50 sq. mm (38mm)
543½ X 120 sq. mm (45mm)
55Supplying and fixing 48"(1200mm) sweep ceiling fan suitable for operation on230 voltsingle phase AC supply i/c connections with suitable sixe of pvc insulated copper cable etc complete as required ( Super Speed ES of M/s Havellsmake or similar superior model of Crompton/Usha/Ortem/ Khaitan make).
56Supplying and fixing 16"(400mm) sweep wall mounted oscillating type fanhaving 3 speed regulator i/c all accessories suitable for 230 volt AC single phase supply i/c connections etc complete as required ( M/s Swing of Havells make or similar superior model of Crompton/Usha/Ortem/ Khaitan make).
57SITC of 600mm x 600mm size surface type prewired 36 W LEDFittingcomplete with all accessories etc.directly on ceiling complete with all accessoriesetc. i/c connections with 1.5 sq.mm. FRLSPVC insulated copper conductor, single core cable and earthing etc. as reqd. (Crompton POLARIS NIO III or similar model of superior make)
58SITC of 4 feet long 20 W LED Batten type Fitting complete with all accessories etc. directly on ceiling / wall i/c connections with 1.5 sq.mm. FRLSPVC insulated copper conductor, single core cable and earthing etc. as reqd. ( trim linea neu OF Crompton make or similar model of superior make)
59Supplying & laying of XLPE insulated4 x 16 sqmm size copper conductor PVC sheathed unarmoured cable conforming to IS 7098 Part I complete as per specification including laying onsurface/ wall/ cable tray with suitable saddle and cleat/clamp arrangementas required.
60Supplying & laying of XLPE insulated4 x 10 sqmm size copper conductor PVC sheathed unarmoured cable conforming to IS 7098 Part I complete as per specification including laying onsurface/ wall/ cable tray with suitable saddle and cleat/clamp arrangement as required.
61Supplying & laying of XLPE insulated3 x 6 sqmm size copper conductor PVC sheathed unarmoured cable conforming to IS 7098 Part I complete as per specification including laying onsurface/ wall/ cable tray with suitable saddle and cleat/clamp arrangement as required.
62Supplying & laying of XLPE insulated3 x 2.5 sqmm size copper conductor PVC sheathed unarmoured cable conforming to IS 7098 Part I complete as per specification including laying onsurface/ wall/ cable tray with suitable saddle and cleat/clamp arrangement as required.
63Supplying and Laying 6mm thick Rubber matting with ISI mark of size suitable for LV supply (ISI Mark) etc. complete as required.
64SITC of Heavy duty Exhaust fan of 450 mm sweep, 1400 rpm speed suitable for operation Nf 240 Volts, 50 Hzsingle phase AC supply complete with installation on duct including making suitable arrangement for fixing in existing AC duct complete with connections etc as required (Model :Turbo Force Neo 1P of Havells or similar model of superior make)
65Supplying & fixing400 A 35 KA FP MCCB, Ics=100% Icu with adjustable overload andshort circuit settings , thermal release range of(320-400A)with spreader terminals , rotary handle in the existing MV panel including dismantling the life expired TPN SFUs, Providing suitable structural modification to the cubicleand door to fix new MCCB with minimum shut down etc complete as reqd
66Supplying & fixing 250 A, 35 KA FP MCCB, Ics=100% Icu with adjustable overload andshort circuit settings , thermal release range of(200-250A)with spreader terminals , rotary handle in the existing MV panel including dismantling the life expired TPN SFUs, Providing suitable structural modification to the cubicleand door to fix new MCCB with minimum shut down etc complete as reqd
67Supplying and fixing 4 Way Vertical type TPN (4+4+4) Double Door, sheet steel, MCB distribution board,415 volts, on surface/ recess, complete with metal door, tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedi/cFour Pole 100 A, 25 KA (80-100) A adjustable MCCBas incomer including earthing etc. as required. (But without MCB/ RCCB/ Isolator )(Incomer MCCB M/s L&T MAKE model DN0-100C or Equivalent Similar Superior Make)
68Supplying, installing, balancing and commissioning of rectangular/round ducting suitable for package typeAir conditioning plant fabricated at site with Galvanized steel sheetof 22 Gauge thickness compelete with neoprene rubber gaskets, elbows, splitter, dampers, vanes, hangers, supports etc. as per approved drawing and specifications complete as required.
69Supplyingof one numberXLPE insulatedPVC inner sheathedAluminium conductorArmouredcable of 1100Vgradeconforming to IS: 7098(Part 1) 1988 with opto date amendmentsof following size etc as required.
703.5 x120 Sq.mm. Aluminium Conductor ArmouredCable
713.5 x50 Sq.mm. Aluminium Conductor ArmouredCable
723.5 x35 Sq.mm. Aluminium Conductor ArmouredCable
73POWER ROOM PANEL :- Supply, installation, testing and commissioning of cubicle type LT panel suitable for 415 V,3 phase , 4 wire 50 HZ AC supply system , fabricated in compartmentalised design from CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plates i/c cleaning and finishing complete with powder coating in approved shade, havingmin. 500 Amps capacity, extensible type TPN aluminium alloy busbars of high conductivity, DMC/SMC busbar supports with short circuit withstand capacity of 31MVA for 1 sec, bottom base channel of MS section not less than 100mm x 50mm x 5 mm thick,lifting hooks, fabrication shall be done in transportable sections, entire panel shall have common copper earth bar of size 25mm x 5mm at the rear with 2 Nos. earth stud, solid connections from main bus bars to switch gears with required size of aluminium bus bars and control wiring with 1.5 sqmm PVC insulated copper conductor cable, cable alleys, cable gland plates in two halfi/c providing following switchgears, transporting from factory to site, unloading, leading etc as required . A) Incoming: i) 320 A , 35 KA FP MCCB, Ics=100% Icu with adjustable overload andshort circuit settings, thermal release range of(250-320A)with spreader terminals , rotary handle and castle key interlock- 2 nos. The castle key interlock shall be provided in the incomers to ensure that one supply is available at a time on each section of bus and to eliminate any possibility of accidently approaching two supplies at one bus section. ii) Digital type Multifunction meter capable to measure parameters likeV, A, F, PF, KW, KVA, Old energy, On and Run hours, site selectablekWh/ kVAhwith RS 485 portclass 0.5- 2 Nos. iii) CTs- ratio 400/5A 15VA CL-0.5 - 6 nos. iv) RYB phase indicating LED lamps with Toggle switch & MCB - 2 set. B) Busbar: i) TPNAluminium busbars of min 500Amps capacity with heat shrinkable coloured sleeves and i/cDMC/SMC busbarcross section, size supportsand their spacing etc for withstanding faultlevel of 31MVA for 1 sec. C) Outgoings: i) 160 A,35 KA 4PMCCB, Ics=100% I cu, with adjustable overload andshort circuit settingswith thermal release range of(125-160 A),Spreader Terminals , rotary handle etc - 3 Nos. ii) 63 A , 35 KA4P MCCB, Ics=100% I cu with adjustable overload andshort circuit settingswith thermal release range of(40--63 A) with Spreader Terminals , rotary handle etc -3 Nos. Complete as above Note : The panel drawing shall be got approved from the Engineer in charge before fabrication .
74AC ROOM PANEL:- Supply, installation, testing and commissioning of cubicle type LT panel suitable for 415 V,3 phase , 4 wire 50 HZ AC supply system , fabricated in compartmentalised design from CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plates i/c cleaning and finishing complete with powder coating in approved shade, havingmin. 300 Amps capacity, extensible type TPN aluminium alloy busbars of high conductivity, DMC/SMC busbar supports with short circuit withstand capacity of 31MVA for 1 sec, bottom base channel of MS section not less than 100mm x 50mm x 5 mm thick,lifting hooks, fabrication shall be done in transportable sections, entire panel shall have common copper earth bar of size 25mm x 5mm at the rear with 2 Nos. earth stud, solid connections from main bus bars to switch gears with required size of aluminium bus bars and control wiring with 1.5 sqmm PVC insulated copper conductor cable, cable alleys, cable gland plates in two halfi/c providing following switchgears, transporting from factory to site, unloading, leading etc as required . A) Incoming: i) 250 A 36kA FP MCCB, Ics=100% Icu with adjustable overload andshort circuit settings, thermal release range of(200-250A)with spreader terminals , rotary handle and castle key interlock- 2 nos. The castle key interlock shall be provided in the incomers to ensure that one supply is available at a time on each section of bus and to eliminate any possibility of accidently approaching two supplies at one bus section. ii) Digital type Multifunction meter capable to measure parameters likeV, A, F, PF, KW, KVA, Old energy, On and Run hours, site selectablekWh/ kVAhwith RS 485 portclass 0.5- 2 Nos. iii) CTs- ratio 300/5A 15VA CL-0.5 - 6 nos. iv) RYB phase indicating LED lamps with Toggle switch & MCB - 2 set. B) Busbar: i) TPNAluminium busbars of min 300Amps capacity with heat shrinkable coloured sleeves and i/cDMC/SMC busbarcross section, size supportsand their spacing etc for withstanding faultlevel of 31MVA for 1 sec. C) Outgoings: i) 100 A, 36 KA 4PMCCB, Ics=100% I cu, with adjustable overload andshort circuit settingswith thermal release range of(67-100 A),Spreader Terminals , rotary handle etc - 6 Nos. Complete as above Note : The panel drawing shall be got approved from the Engineer in charge before fabrication.
Disclaimer :