Tender For Redevelopment Of Dhobikhana On Conran Smith Road In Purasawalkam, Chennai, purasawalkam-Tamil Nadu

Chennai Metropolitan Development Authority-CMDA has published Tender For Redevelopment Of Dhobikhana On Conran Smith Road In Purasawalkam, Chennai. Submission Date for this Tender is 18-10-2023. Road Work Tenders in purasawalkam Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

39758189
Corrigendum : Tender For Redevelopment Of Dhobikhana On Conran Smith Road In Purasawalkam, Chennai
Open Tender
Indian
Tamil Nadu
purasawalkam
18-10-2023

Tender Details

Tender For Redevelopment Of Dhobikhana On Conran Smith Road In Purasawalkam, Chennai

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 04-Oct-2023 Corrigendum Date 11-10-2023
2 11-Oct-2023 Corrigendum2 Date 18-10-2023

Key Value

Document Fees
Refer document
EMD
INR 518000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Redevelopment of Dhobikhana on Conran Smith Road in Purasawalkam, Chennai
Sl. No. Item Description
1Civil Works
2Dismantling the damaged Doors and windows including removal of frames, Hinges, fastenings etc., complete complying with standard specification and as per the direction of the Engineer-In-Charge.
3Dismantling the damaged Asbestos sheet and clearing away with carefully stacking the material useful for reuse etc., complete complying with standard specification and as per the direction of the Engineer-In-Charge.
4Dismantling the damaged brick / stone masonry work in cement mortar and clearing away with carefully stacking the material useful for reuse for any thickness of wall under 3 m heights etc., complete complying with standard specification and as per the direction of the Engineer-In-Charge.
5Dismantling, removing and carefully stacking Reinforced cement concrete and clearing away the same 50 m away from the site and roughening the surface etc., complete complying with standard specification and as per the direction of the Engineer-In-Charge. .
6Dismantling, Plain cement concrete and clearing away the same 50 m away from the site and roughening the surface etc., complete complying with standard specification and as per the direction of the Engineer-In-Charge.
7Earth work excavation and desposting on banks with initial lead of 10m and initial lift of 2m in hard stiff clay, stiff black cotton soil, hard red earth, shales, murram, gravel, stony earth and earth mixed with small size boulders et., As per SS 20B excluding hard rock requiring blasting inclusive of shoring shuttering, baling ojut water where ever necessary and including refilling consolidation etc., complete in all respects complying with relevent standard specifications and as directed by departmental officers.
8Total for - (First depth ( 0m -2m )
9Total for - (Second depth ( 1m -2m )
10Supplying and Filling withM - sand in foundation and others sub structures for 100mm thick and well watered, rammed and consolidated by power compacter. The rate includes the cost of M sand, compacting with mechanical compactors, labour charges for leveling, loading & Unloading and Transportation charges etc., complete and as per the standard specification.
11Supplying and filling of Gravel / Good Earth by lorry in Foundation basement filling and site filling with approved materials excavation from approved quarries and compacted to meet requirement of table 300-1, 300-2 of MORTH, in layers not exceeding 300 mm loose thickness, spreading, breaking clods, removal of roots and other organic materials to the required line, grade and cross-section including watering, spreading by Dozer, grading by motor grader and consolidation by vibratory road roller with desired field density not less than 95% of maximum dry density ,including all lead,lift, loading, unloading, all labour, hire charges of all machineries, Transportation, etc., complete in accordance with MORTH technical specification clause No. 305 and with all other incidental charges and as per the direction of the Engineer-In-Charge.
12Construction of Granular sub-base of 125mm compacted thicknessby providing laying, spreading and compacting of Close graded Material conforming to Grading V of Table 400-1 of MORTH clause 401 ,mixing in a Wet Mix Plant of 200 tonne capacity at OMC, carriage of mixed material to work site, spreading in uniform layers with motor grader on prepared surface and compactingwith vibratory roller 8-10 tonne to achieve the desired density of 98% including protection of edges of GSB layer, cost of all materials, labour, hire charges of machinery, lighting, guarding, barricading, maintenance of diversion road, loading & unloading, all lead and lift etc.,to achieve minimum CBR value of 30%(Compacted Thickness)in accordance with MORTH technical specification clause No. 401 and with all other incidental charges and as per the direction of the Engineer-In-Charge of work.
13Construction of Wet Mix Macadam 250mm compacted thickness in two layers by providing , laying , Paving , and compactingofaggregate gradation satisfying to Table 400-13 of MORTH and satisfying the physical paraeteres as per MORTH Table 400-12, mixing in a Wet Mix Plant of 200 tonne capacity at OMC , carriage of mied material to work site and laid in sensorpavers to the required line and grade as per the drawing and compacted with vibratory roller of 8-10 tonne to achieve the desired density of 98% of Maximum dry density and as per the direction of the Engineer-In-Charge of work.
14Providing and laying plain cement concrete1 : 4 : 8 ratio of (1 cement , 4 sand and8 graded stone aggregate 40mm nominal size) in foundation and basement including dewatering wherever necessary and laid in layers not more than 15 cm thick and consolidation etc. The rate includes the cost of materials, labour charges, lifting charges, loading & Unloading and Transportation etc., complete and as per the standard specification.
15Supplying and erecting centering for sides and soffits including supports and strutting up to 3.30 m height with all cross bracing for plane surfaces as detailed below, using mild steel sheets of 90 X 60 cm 10 gauge stiffened with MS angle of 25 X 25 X 3mm for boarding, laid over adjustable span & jacks and supported by 50mm dia pipes for general pipes scaffolding systems @ a spacing of 1.20m c/c and vertical connected at a height of 2.0m c/c including "C" & "U" clamps and base receiver cup at bottom for connecting pipes etc and removable systems etc., the rate including cost of all materials, labour charges, wastages, placing, transportation, lead & lifts, tools & plants, fuels, fixing in position at all levels, heights, masking tape in sheet joints, consumables, etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
16For Column footing, plinth / grade beam, bed blocks, template surfaces, steps, piers, raft slab / beams and such other members
17For Vertical surfaces such as vertical slab, side slabs of boxing, vertical drops, facia,vertical walls etc.
18for plane surfaces such as rectangular or square rcc columns, sunshades, topand bottom slab of rcc boxing, etc.
19For Plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc.
20Extra for additional height in centering, shuttering wherever required with adequate bracing, propping etc. including cost of de-shuttering and decentring at all levels. over a height of 3 30 m (height shall be the dimension as measured from the top of the lower slab/pcc sub base to the bottom of the subsequent upper stab) for every additional height of 1m or part thereof for plan area to be measured Suspended floors, nat slabs. drops. post tensioned slabs, slabs curved in plan to any radius, grid slab,rools landings beams including spiral and curved beams of all radius, post tensioned beams, gnd beams, plinth beams. girders, bressumers. cantilevers and balconies.Rate to include all matenals, labour charges, wastages placing. transportation, lead & lifts, tools & plants, fuels, fixing in position at all levels, masking tape in sheet joints, consumables, etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge
21Providing and Laying M 30 Design Mix for all reinforced cement concrete with minimum cement content conform to IS 456-2000 using ordinary Portland cement of grade 53 from approved manufacturer, manufactured sand, 20 mm and down graded size coarse aggregates, necessary approved admixtures as per requirement. works for Footings, Grade beam, drain wall & raft , Plinth beams, Column, Grade slab, Roof slab & beam, Column drops, Pergola, Staircase waist and landing slab lintel, Sunshades, parapet Cum drops, Steps, canopy, window boxing slab, Loft, fins facia Planter box, machine foundation, elevation features and other similar structures etc..excluding necessary centering, shuttering and reinforcement which shall be measured and paid separately under relevant items. in-charge. The rate including cost of all designing the mix, batching plant, mechanical mixing, transporting and placing at all levels, leads, lifts, tools & plants, fuels, all materials, labour charges, wastages , laying, pumping the concrete to all levels, providing sleeves / openings in RCC slabs, compaction by vibrator, gunny bags for curing etc. as complete with all respects complying with relevant standard specification, as directed by theEngineer-in-charge
22Basement
23Ground Floor
24First Floor
25Second Floor
26Supplying, fabricating and fixing in position of steelFe 550 grade Reinforcement for all RCC work with Thermo Mechanically Treated Bars (TMT) conforming to IS 1786 of latest version according to drawings and binding the reinforcement with 18 gauge double fold GI binding wire and providing Concrete cover blocks to maintain the cover as required. The rate including cost of all materials, bending, tying grills, placing, transportation, lead & lifts, tools & plants, fuels, all materials, labour charges, wastages , laying at all levels, fixing in position, cost of cover blocks and GI binding wires etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
27Supply and constructing Fly ash Brick masonry in Cement Mortar 1:5 (One cement and Five M sand) in foundations, basement and superstructure usingFly ash Bricks of size 230x110x75mm etc., complete complying with standard specification and drawings and as directed by the Engineer -in-charge.
28Ground Floor
29First Floor
30Supply and constructing Flyash Brick partition wall 115mm thick in Cement Mortar 1:3 (one cement and three M sand) 11.50 CM thick using usingFly ash Bricks of size 230x110x75mm including both side plastering with CM 1:5 12mm thick and usinghoop iron reinforcement if found necessary and hoop iron shall be supplied to the department at free of cost etc., complete as directed by the Engineer in- charge.
31Supply and constructing cement concrete solid block masonry work at all levels in cement mortar 1:5 (1 of Cement : 5 ofmanufactured sand ) using Portland Pozzolana Cementstandard size of 400 x 200 mm and 200 mm thick of solid cement concrete with minimum compressive strength of 5 N/Sq.mm.conforming to IS 2185 or equivalent BS and Fly ash conforming to IS : 3812 (Part III)-1966* may be used for part replacement of fine aggregate up to a limit of 20 percent complete and as directed. Concrete blocks manufactured under strict quality control conditions using modern rugged block casting and stripping machine with the latest mouldingtechniques etc,. only shall be used. The rate including cost of all materials, labour charges, wastagesfor working at all levels with necessary lead and lifts, transportation charges, loading, unloading, scaffolding, staging, curing, fuel, consumables as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge
32Ground Floor
33First Floor
34Second Floor
35Plastering 10 mm thick for ceiling including slabs, beams and column drops and staircase waist slab, sunshade, drops, chajjas etc..with Cement Mortar 1:3 (1 of cement : 3 of P sand) according to the specification. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, providing drip bands, moulds to any size and shape as shown in drawings tools and plants, fuel, curing,cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.
36Plastering of 12 mm thick for Internal walls with cement mortar 1:5 (1 of cement : 5 of P sand)according to specifications. Rate shall include for providing GI mesh of nominal thickness at the junctions of masonry and concrete works to a width of 100 to 125mm including tying in position with suitable clamps/screws. The rate including cost of all materials, labour charges, wastages with necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, tools and plants, fuel, curing,cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.
37Plastering 15 mm thick for external surfaces with Cement Mortar 1:4 (1 of cement : 4 of P sand) with water proofing compound of “CICO No.1 or equivalent“ as per Manufacturer"s Specification with sponge finish (washed sand finish) all complete as per specification and as directed. The rate includingcost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, providing drip bands, moulds, grooves to any size and shape as shown in drawings tools and plants, fuel, curing,cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.
38Supplying and fixing Dadooing the wall with ceramic tiles of approved quality, colour and design joint free of size 600x300x10mm thick of approved make, in all floors over a base layer of cement mortar 1:2 (one cement: Two sand) 10mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40 kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading,the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.
39Supplying and fixing Dadooing the wall withbrick elevationtiles ofapprovedqualitycolour, designandofsize230mm x 75mm of approved make, in all floors over a base layer of cement mortar 1:2 (one cement: Two sand) 10mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40 kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading,the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.
40Supplying and laying of Flooring with Joint free double charged vitrified tiles of approved quality, colour and design joint free of size 600 x 600 x 8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3 (one cement three sand) 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40 kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officers. The rate including cost ofall materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading,the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. (Including Skirting work)
41Supplying and laying of Ceramic tiles of size 305 x 305 x 6mm for flooring approved make and quality with plain/colourwith base mortor in CM 1:3, 10mm thick and pointing with white cement by adding suitable colour pigments including finishing, jointing and polishing with neat finish etc., complete. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading,the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.
42Supply & Laying with the best quality approved kotta stone slab not less than 20mm thick and the size of slab in general not less than 600 X 600 mm machine cut and machine high pre - polished set in C.M 1:4 20 mm thick with white cement sluury for surface contact of the bottom of the kotta slab as per approved pattern / design as per the drawings by using irrespective of size and shapes including finishing the joints with white cement sluury, cutting, edge chamfering and polishing rough, medium nice and acid wash and tin - oxide polish. Rate including all materials labour Charges, wastages, Necessaryleads & lifts working at all levels transportation charges loading and unloading, preparation of surfaces, necessary hacking in RCC surfaces cutting to required shape tool, and plants fuel, curing, cleaning acid wash over finished surfaces, protection with Gypsum / Pop layer over plastic sheet and removing the same before handling over as complete with all respects complying with relevant standard specifications and as directed by the Engineer in Charge
43Supply and Laying flooring with best quality approved colour 18mm thick Flamed Steel Grey Granite Slab for Staircase andRamp flooring of size not less than 1200 x 600 mm machine cut and set in C.M 1:4 (1 of cement: 4 of manufactured sand) 20 mm thick topped with white cement slurry (for surface contact of the bottom of the granite slab) as per approved pattern, including finishing the joints with matching shade, cement slurry, cutting, edge chamfering and polishing rough, medium, nice and tin-oxide polish.Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading. preparation of surface, ncessary haccking in RCC surface, cutting to required shape, edging, antiskid grooves,tools and plants, fuel, curing, cleaning, acid wash over finished surface, protection with Gypsum/Pop layer over plastic sheet and removing the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.
44Supplying and filling the sunken slabarea byBRICK-BATCOBA by adding CICO NO:1 or approved equivalent admixture including applying two coats not less than 2 mm thick of TAPECRETE- AcrylicPolymer Based Waterproof Coating, over the final coat of cement plaster 12 mm thick with cement sand mortar 1:3 mixed with water proofing compound like CICO No.1 at the rate specified in the manufacturer"s specification after entire completion of laying pipes, sanitary fittings etc. Rate including all materials, labour charges, wastages with necessary lead and lifts, working at all levels, protecting the laid pipes and sanitary fittings, finishing the surface smooth to receive the top coat of water proofing application etc. as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.
45i) Includingapplying two coats not less than 2 mm thick of TAPECRETE- AcrylicPolymer Based Waterproof Coating, over the plastered surface as including final coat of cement plaster 12 mm thick with cement sand mortar 1:3 mixed with approved water proofing compound like CICO No.1 or approved equivalent conforming to IS 2645 at the rate specified by the manufacturer over coated surfacepreparation of surface, finishing, curing etc. all complete at all levels as per manufacturer"s specifications and as directed.
46TERRACEWATERPROOFING: Supply and laying water proofing treatment for terrace covering the following order andconsisting of following operations. i) Making " V " grooves at the construction joints of size20 x 20 mm and filling the ""V"" Groove with CICO No. 3 Quick Setting Waterproofing Compound admixed with cement.The roof slab / gutter slabshall be thoroughly cleaned to remove debris and dust, and applying 2 coats not less than 2 mm of polymer based Elastomeric Coating like TAPECRETE - RTU compound and cured for 7 daysand followed by a layer of 20 mm thick cement mortar 1:3 admixed with CICO NO:1 (or) other approved equivalent make shallbe spread over the prepared surface. On the spread mortar provide and laywell burnt brick bats (COBA) to a average minimum thickness of 55 mm (i.e.. minimum 40 mm thickness at lower end and 70 mm thickness at higher end).An additional layer of brick bat (COBA) shall be laid over the existing brick bat COBA surface if required to get the required gradient for adequate drainage giving a slope of approximately 1 in 120, which will be measured separately under relevantitem
47The gapbetween brick bat shall be filled with cement mortar 1:4 admixed with waterproofing compound like CICO NO:1 or approved equivalent afterwards curing shall be carried out for two days a final layer of cement mortar of 1:3 admixed with water proofing compound like CICO NO:1 or approved equivalent make shall belaid toathickness of20 mm and draw a false line of 300 mm x 300 mm. The parapet side wall / gutter wall shall be thoroughly cleaned to remove all dust particles and a layer of 15 mm thick C.M 1:3 shall be laid to a height of about 300 mm above the top of the terrace/Gutter slab on the Parapet / Gutter side wall admixed with water proofing compound like the CICO NO:1or approved equivalent make. Providing, supplying, mixing, applying two coats of ready to use two component Acrylic polymer modified cement based, flexible, water proofing slurry like or approved equivalent to a thickness of 2 mm over the plastered surface of operation as per manufacturer"s specification and as directed.(Plan area of Terrace only will be measured for payment )
48Supplying and laying ofTop of roof with Solar refelective tiles of size 305 x 305 x 7mm thick of approved quality and colour laid in Cement mortar 1:3 (One cement and three crushed stone sand) 12mm thick and pointed with tile grout (Nitotile Grout or equivalent) and cement in the ratio of 1:3 for joint, curing etc., complete complying with standard specification and as per the direction of the Engineer-In-Charge. (The make and brand of the tiles should be got approved by the Executive Engineer before use on works)
49Supplying and laying Tamin Paver Block with pattern 80mm thick, any colour of approved sample as per designed Pattern / drawing made ofM40 concrete- 80 mm thick includingtransportation of the blocks to the site preparation of surface including supplying and filling with manufactured sand to 50 mm thick, levelling and compacting with plate vibrator and laying of the inter locking paving blocks with sand binding and final compaction with plate vibrator of 3 tonne capacity finishing the surface including cutting of blocks at the edges including all labour, materials, transportation, shifting etc.,complete, as directed by the Engineer-in-charge.
50Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of all materils, Labour charges for cutting, bending, welding, grinding, polishing, Transportation, electrical charges, etc. complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
51Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for Terrace Drying area using vertical post of 100 x 100 x 6mm tube post, 100 x 200 x 4mm post and top horizontal railings with 50 x 50 x 2mm thick pipe with middle and bottom railings of 32 x 32 x 2mm thick fixed with SS plate of 50 x 4mm thick made up of 304L Grade Stainless Steel pipe.The rate is inclusive of all materils, Labour charges for cutting, bending, welding, grinding, polishing, Transportation, electrical charges, etc. complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
52100 x 100 x 6mm - Post
53100 x 200 x 4mm - Post
5450 x 50 x 2mm & 32 x 32 x 2mm + Vertical support
55UPVC Window :Supplying and fixing UPVC (Un-Plasticized PolyvinylChloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm125GSMand 100% corrosion free, the profiles are multichambered sections with wall thick of 2mm. The EPDMrubber (black colour) covered with over all the edges offrame and shutter the shutter will be provided withEspag multi power point locks and also it operates ashandle. The corners and joints should be welded andcleaned. Radiations free pin headed plain or browncolour glass 4mm thick should be provided to theshutter and it should not allow leakage of water evenat most ranging storms and should have key lockableaction, security protective hinges, strong lockingsystems and as per size for arresting noise and energyloss. The connecting mechanism between sash andouter frame that enables opening of the window. Thewindow should be fixed to the wall with 100% packingwith screws and silicon packing all round the frames.The window should be got approved from the Executive Engineer before use on work.
56Foamed PVC Door frame : Specification: Providing factory made Pre Laminated FPVC Door Frame of the size 105 X 40mm with a wall thickness of 10mm made out of extruded rigid FPVC profile mitre jointed with 6nos of 5mm long screw. The door frame shall be fixed to the wall by using 80 mm long screws through the frame frame with the help of PVC Fasteners of 3 nos. to be provided for each vertical member, GI stiffners of ( U channel of size 29 X 9, 1mm, 150mm long) - 3 Nos at hinge point, Frame Reinforcement of (U" GI channel of size 46 X 22 X 0.6mm), bottom tie rod of ("U" GI channel Size of 15 X 15 X 1mm ), etc., Complete complying with the standard Specification. the door frame should be got approved from the Executive Engineer before use on work Providing of 35mm thick factory made pre - laminated ABS ( Acrolynitrile Butadiene Styrene) Door Shutter moulded indifferent desings consisting of all round frame made out of water proof solid PVC bar of size 20 X 32 mm reinforced by 32 X 32 mm 2 nos ., for vertical made out of LVL core material of 32 mm thick high density craftpaper honey comb board, sandwiched on both sides with pre- laminated ABS sheets thickness of 1.5mm PVC edge bending of size 0.45mm on the vertical sides. hardware made out of steels coated butterfly hinges - 3nos for each shutter and ISI make SS round lock Complete complying with the standadrd Specification . the door shutter and frame should be got approved from the Departmental Engineer before on use.
57Door Size- 1000 X 2100mm
58Door Size- 750 X 2100mm
59Providingandfixing welded M.S. grills to the window openings,along the details as per drawingwith necessary screws, bolts andfixed withnecessaryM.S. lugs embedded in masonry with C.C. 1:2:4 and finishing the surface neatly. Rate shall welding and consumables, etc. complete, as directed. Design of grills and the size of members to be used shall be got approval before put into use & as directed by the Engineer-in-charge.
60Supply and fixing RCC precast slab manhole cover SFRC of 50mm thick and required size 600mm x 600mm made in CM 1:3 Ratio both direction including cost and conveyance of all materials, labour and transportation etc complete complying with standard specification.
61Supply and fixing RCC precast tank of required size50mm thk wall and 600mm dia with height 600mm of 4mm thick weld mesh 75 mm spacing on both direction, and M45 Grade concrete including cost and conveyance of all materials, labour and transportation etc complete complying with standard specification.
62Providing and laying non-pressure class NP2 RCC Spun pipes with collars including excavation of trenches in soil/murum/rock, laying the pipes as per layout and drawing, filling the joints with stiff mixture of cement mortar (1 part cement :1part fine sand) and jute, curing, testing the pipe and refilling the trenches in layers with due compaction & watering etc. complete as directed
63Providing fencingthe with new G.I Barbed wire fencing with G.I wire using two ply at 0.30m center to center with four prong (Glvanized) warms of tying with binding wire including aligning, tightening, neatity etc., complete complying with standard specification and as directed by the department officers.
64Supply and painting oftwo coats of Acrylic emulsion paint of approved shade and colour over one coat of DCP Primer including one coat of Acrylic Wall Putty with DCP Primer. The rate including cost of all materials, brush, roller, ladder, scrapping, washing, materials, labour charges, wastages , cleaning, necessary lead and lifts, scaffolding, stagging, working at all levels, elevations,transportaion charges, loading, unloading, curing, sanding, touchup putty, surface thoroughly cleaned and wetted before painting as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.(Internal surface)
65Supplying and painting of2 coats of weather proof exterior emulsion with high sheen, anti algal properties over one coat wall exterior primer of approved quality and shade etc., complete. The rate including cost of materials, brush, ladder, scrapping, washing, materials, labour charges, wastages , cleaning, necessary lead and lifts, scaffolding, stagging, working at all levels, elevations,transportaion charges, loading, unloading, curing, sanding, touchup putty, surface thoroughly cleaned and wetted before painting as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.
66Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors including cost of priming coat etc., complete complying with standard specification. ( The make quality and colour of paint should be got approved by the executive Engineer before use on works.)
67PLUMBING AND SANITORY WORK
68SANITARY FITTINGS
69Supplying and fixing in position Indian water closet of size 580 x 440mm, glazed earthern ware of approved quality and colour with "P" trap or "S" trap confirming to IS:2556-part XII with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One of Lime, Two of Sand, Five of Brick jelly) 100mm thick and by dismantling brick masonry, reinforced finishing to the required slope and including giving necessary connection to PVC soil pipescement concrete roof / floor slab and making good the disturbed portion to origional condition without leakage etc., complete complying with standard specification and as directed by the departmental officers. (The water closet should be got approved by the Executive Engineer before use on works)
70Supply and fixing in position whiteEuropean Water Closet of approved make with Porcelain low level flushing tank 12.5 litre capacity of best quality and approved make with 100mm P or S trap with double flapped rigid PVC seat cover with CP brass hinges etc. complete complying with standard specification and as directedby the Departmental officers (The EWC should be got approved by the Executive Engineer before use on works.
71Supplying and fixing of CP Two Way Bib Cock with Health Faucet ,wall hook & one metre longflexibletubeincludingcuttingandmakinggoodthe wallswherever requiredetc complete.complyingwithstandardspecificationandas directedbytheDepartmentofficers.Thequalityandmakeofhealth faucet should be got approvedby Concern department Engineer before use on work.
72Supplying and fixing Wash Hand Basin of size 550 x 400mm with all accessories such as cast Iron Brackets, 32 mm Dia C.P. Waste coupling, Rubber plug and Chain, 32 mm dia " B " Class G.I. Waste pipe, 15 mm Dia G.M Wheel valve; 15 mm Dia Nylon connection, 15 mm Dia Brass Nipples, 15 mm C.P. Pillar tap etc.,including fixing the wash hand basin in the wall in position with a pair of C.I. brackets with teak wood plugs and screws and giving necessary water supply connection and as directed by the Department officers.(TheWash basin should be got approved by the Executive Engineer before use on works.
73Supplying and fixing Lipped Mouth Porcelain Flat Back Urinal(white colour) of size26.5x31.5x44cm with all accessories such as 32mm dia Bell Mouth PVC Connection, 15mm dia GM Wheel Value, 15mm dia "B" Class GI Waste Water Pipe, 15mm dia Nylon Connection, 15mm diaBrass Nipple, and suitable screws, shellac etc., complete. The rate including cost of all materials, labour charges for fixing and transportation etc. completed as directed by Engineer-in-Charge.
74Supplying and fixing the best quality approved make of SS heavy duty long body Tap including cutting and making good walls wherever required etc.complete,complying with standerd specification and as directed by the department officers. The quality and make of angular stop cock should be got approved by concern department engineer before use on work.
75Supplying and fixingBrass Chromium Plated Towel Rail 60cm long and 20mm dia with brackets of same materials including cost of teak wood plug & CP screws etc., complyingwithstandardspecificationandas directedbytheDepartmentofficers.
76Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 600 x 450 x 5.5mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on woks) .
77Supplying and fixing heavy duty 15mm CP shower unit comprising of CP 15mm dia hot & cold mixer with CP spout, overhead shower set comprising of CP shower arm, rose etc.,complete with CP wall flanges. The rate including cost of all materials, labour charges and transportation etc. completed as directed by Engineer-in-Charge.
78Supplying,installing,testing and commissioning of approved make CONCELD STOP COCK for toilet including neccesary accessories etc,complete,works include making require size curout in wall,and fixing the control box property,redoing the same etc,complete the quality and make of concealed stop cock should be got approved by concern department Engineer before use on work.
79SOIL, WASTE AND VENT PIPE LINES
80Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications.(The PVC pipes should be got approved by the Executive Engineer before use on works). (Internal & External)
8150mm dia. 6 kg / sq.cm.PVC pipes.
8275mm dia.6 kg / sq.cm. PVC pipes.
83110mm dia. 6 kg / sq.cm. PVC pipes.
84160mm dia. 6 kg / sq.cm. PVC pipes.
85200mm dia. 6 kg / sq.cm.PVC pipes.
86Supplying & fixing in position PVC Nahini / Floor trap of size 100x75mm including stainless steel gratings of approved brand & quality, fixed over a bed of brick jelly limeconcrete 1:2:5 ( One part of lime, two parts of sand & five parts of 40 mm size brick jelly ) & finished with cement mortar 1:3 ( One cement & three sand ) includingdismantling masonry works wherever found necessary & making good the damaged portions to the original condition & giving connections to the cast iron pipes etc., complete, complying with standard specification. (The PVC Nahini / Floor trap should be got approved by the Executive Engineer before use on works ).
87Supplying and fixing in position PVC cowls of following dia of best approved quality conforming to BIS, etc., complete complying with standard specifications.(The PVC cowl should be got approved by the Executive Engineer before use on works).
8875mm dia
89110mm dia
90EXTERNAL DRAINAGE
91Supplying & fixing in position 150 X 100 mm square mouth "P" or "S" trap stone ware Gully trap "A" gradewith cast iron double gratings of size 150 X 150 mmwith C.I. air tight cover with frames of size 300 X 300 mm at bottom & top respectively with necessary earth work excavation, laid over a bed of brick jelly cement concrete 1:3:6, 150 mm thick using 20 mm size broken brick jelly including necessary brick work & plastering, &including dismantling masonry wherever necessary & redoing the damaged portions to the original condition & by using cement concrete 1:3:6 using 20 mm stone jelly for fixing the Gully trap & giving connections to the stone ware sewer line etc., complete, complying with standard specification. (The stone ware gully trap should be got approved by the Executive Engineerbefore use on works ).
92Constructing solid block masonry manhole various size of deep in cement mortar 1:3( 1 Cement: 3 coarse sand ) R.C.C. Raft & top slab with cement concrete 1:2:4, plain cement concrete 1:4:8 mixfor base course (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size )above that 150 mm thick RCC M25 raft slab inculding reinforcement 10mm dia 150mm c/c bothways. Plastering inside walls with 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand ) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ), finished with a floatingcoat of neat cement ,supplying and fixing SFRC manhole cover with farame of size 600x600 mm , PVC foot rest as per detailed drawing etc the quoted rate shall also necessary excavation and back filling etc complete.complete as per standard design : (the chamber and cover should be got approved by the Executive Engineer before use on works)
93450x450mmx 600mm deep to 1000mm deep
94600x600mmx 600mm deep to 1000mm deep
95600x700mmx 600mm deep to 1000mm deep
96Construction of Rain water Recharge well (1500mm dia) as per consultant drawing with necessary connections, Earth work - digging the well for recharge well. supply and installation of Reinforced concrete Rings - 5 feet OD & 1 feet Height, 50 MM Thick - 10 no"s. supply and installation of Reinforced concrete slab- 5 feet in dia, 200 mm thick, and 25 mm perforated - 8 mm mild steel rods used for reinforcement -1" Perforated - 1no"s. supply and installation of Reinforced concrete closing slab - 3 feet in dia OD, 75 mm thick, 8 mm mild steel rods used for reinforcement with 600mm x 600mm Square FRP/Plastic manhole cover - 1no"s. supply and installation of MS grating - 6*6inch square - 2no"s Filtration Media Installation For recharge Well Unit: 40 mm crushed stones - 0.12cum, 20 mm crushed stones - 0.12cum, Brick Bats - 0.12cum, Mixture of Brick Bats and Gravels for filling the gap between excavated earth and RCC rings- 1.6cum Shifting of excavated earth to the approved / authorised dumping yard as directed by the authorities / Site in charge. supply and installation of `V" WIRE SCREEN - 0.75 mm Slots. SS-304 Material - 0.5 mtrs Height -6 " diameter - 2no"s Drilling a bore well - 200mm dia by high speed compressor- 4MTRS. supply and installation of 110mm PVC PIPE PN-6- 4 rmtr, 110mm PVC PIPE PN-6 Perforated with 10 mm Zigzag holes to easy percolate the water - 4 rmtr, 12mm Gravel Packing between bore well hole and PVC pipe and Inserting into the Bore Well- 4 mtrs. supply and installation of- 180GSM Gio-fabric sheet to cover V-Wire screen, Shifting of excavated earth upto 1000mtrs as directed by site in charge. (the well sholud be got approved by theExecutive Engineer before use on works)
97Size - 1500mm diameter, 4.0 mtr depth and 200mm dia bore upto 4 rmtr.
98WATER SUPPLY SYSTEM
99Internal Concealed Works
100Supplying, laying and jointing CPVC pipes SDR 11(having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing CPVC specials using CPVC adhesivesand fixing into wall with teak wood plugs, CPVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications.The CPVC pipes shall be got approved by Executive Engineer before use on works. (Internal & Extenal)
10120 mm nominal (OD) pipes
10225 mm nominal (OD) pipes
10332mm nominal (OD) pipes
10440mm nominal (OD) pipes
105EXPOSED &EXTERNAL PLUMBING WORKS
106Providing, supplying & laying ofUnplasticized Polyvinyl Chloride (UPVC-SDR-11) Pipes conforming to IS 15778 having thermal stability cold water with brass and UPVC fittings like Elbow,Brass Tee, Brass Elbow,Offsets,Tee with clamps @1.00 meters spacing, with jointing of pipes with one step UPVC solvent cement with including cutting of chase including testing of the joints complete and making good the walls etc.Rate is inclusive of all material labour, transportation,tools & tackles all complete as per as per specifications,Concealed work including chase cutting) complete complying with standard specification and as directed by the Departmental Officer.
10725mmnominal(OD) pipes
10832mmUPVC pipes
10940mmnominal(OD) pipes
11050mmUPVC pipes
11165mmnominal(OD) pipes
112Supply and fixing in position first quality and approved variety of various dia UPVC Ball Valves (Heavy type) with I.S.I Mark of the following size including cost of shellac, thread etc.,including labour for cutting and threading of pipes etc., complying with standard specification for both internal and external water supply arrangements.
11325mm DIA
11432mm DIA
11540mm DIA
11650mm DIA
11765mm DIA
118PUMP
119Supplying and erection submersible pump set of Three phase 5.00 H.P of best approved quality and make with ISI mark including fixing of starter,main switch and panel board with necessary labour including run off 4 of 10 Sq,mm, in P V C pipe with 14 SWG TC wire including fixing of suction pipe and foot valve etc., complete and operating the pumps on trial run for 3 days. (The make and quality of pump set to be got approved by the Executive Engineer before use on works.)
120WATER METER
121Supplying,fixing,commissioing and testing25 MM Water Flow Meter Straight Reading Magnetic Drive Screwed Class B ISI Marked Water meter for Domestic and Professional use to measure the flow of the water. MULTI JET – MAGNETIC DRIVE –DRY DIAL CONFIRMING TO CLASS “B” 25MMOF ISI 4064/1 & IS -77-1994 WITH ISI Mark
122BOREWELL
123Drilling of 12" dia vertical borewell so as to have a finished size of 6" dia borewell in boulder area to any required depth as decided by the TWAD Board Officers including Transportation from one place to anothr place with in Tamilnadu State by direct or reverse rotary mud circulation method using Contractor"s rig tools, fuel, labourers, bentonite mud and water required for drilling at the site shown by the TWAD Officers including construction of mud pit etc. using only calyx rigs.
124300mm
125150mm
126Reaming from 200mm dia pilot bore to 350mm dia bore as direct by the Engineer incharge up to 80mtr depth ending below ground level
127Supply and laying following dia PVC casing pipe with excise duty as per IS 12818 / 1992
128200mm dia CS ( plain pipe
129200mm dia RS
130150mm dia RS
131Labour charges for inserting PVC casing pipes assembly (with slots or without slots) in the drilled hole including jointing the pipes with PVC couplers with cement paste etc., complete, supply and packing the annular space with pebbles of size and quality as approved by the Executive Engineer of Departmental officers.
132200mm dia CS
133200mm dia RS
134150mm dia RS
135Supplying and filling with river pebbles in annular space between bore and PVC pipe up to hard rock.
136Charges for developing the borewell with air compressor of 300 CFM capacity (Minimum 8 Hours) including transportation labour and fuel charges for compressor as directed by TWAD Board Officers and conducting yield test by "V" notch method.
137Supply ,erection and testing & commisioning of 3HP submersible pumpset in the to suit 200mm borewell of capacity of 4800 LPH @ 265Ft, max. total head of 280 Ft pumps fitted with bronze impellers and having delivery size of 40mm - 430V along with 3mts cable and manufactures standard control panel which is mandatory and as directed by the officer incharge and other required supporting items like SS hose nipple, nylon rope, clamps, bolt and nuts,GI nipple, 50mm dia HDPE hose of required length etc completed and as directed by the officer incharge.
138Electrical Works
139Supply and Fixing of CPRI approved make EB metering panel, IP 54,made of 1.6mm thick Treated & powder coated MS Sheet, compartmentalised, as per TNEB standard, for housing 3phaseEnergy meters and rewireable Fuse outletin lockable compartments, outgoing 4 Pole MCB, fuse unit as incomer ( 1 incomer + 14nos of3 phaseoutgoings ) .The metering cubicle type, Free standing, floor mounted, single front, 14 SWG CRCA sheet steel, enclosed separate compartment for each feeder, front operated, Powder coated, indoor type dust and vermin proof, hinged lockable doors, complete with electrolytic grade copper bus bars,internal wiring, colour coding, ferrules, Panel mounting MS Channels, fasteners, etc., RYB indication lamps,internal wirings, Digital voltmeter and Ammeterand other required accessories for the complete operation as per the Tangedco requirements. Necessary approval to be obtained from Tangedco before procurement including all associated control wiring cubicle shall be suitable for floor mounting, with painted Mild steelstand made of MS Angles For all items in this section, the rate includes necessarysupports as required at site. No extra payment will be made for the same. Rate shall inclusive of factory witness testand all accessories, breakers , control wiring, models has to be followed as per in the technical specification.
140Incomer : 500 ams Porcelain rewireable fuse carrier with bus extension-3 nos. 3 nos of 230VLED indication lamps with 6A protection fuse. Outgoing metering compartment :14 nos, each comprising Space for mounting 3 phase 5-30amps 3 phase energy meter with base Hylum sheet. 3 nos of 63amps rewireable fuse cutouts and 1 no of Neutral link. Outgoing MCB compartment:14 nos, each comprising 1 no of 63amps 4 Pole MCB,C Curve, 10KA Busbar compartment: 50x6mm , electrical grade , copper bus bar, withinsulated with color coded as per standard,hardware for wire extension. 6 sq.mm PVC insulated copper conductor ,FRLS .wire for branch extension , and termination with copper lugs.
141Supply and Fixing of CPRI approved make EB metering panel, IP 54,made of 1.6mm thick Treated & powder coated MS Sheet, compartmentalised, as per TNEB standard, for housing 3phaseEnergy meters and rewireable Fuse outlets in lockable compartments, outgoing 4 Pole MCB, fuse unit as incomer ( 1 incomer + 12 nos of 3 phaseoutgoings ) .The metering cubicle type, Free standing, floor mounted, single front, 14 SWG CRCA sheet steel, enclosed separate compartment for each feeder, front operated, Powder coated, indoor type dust and vermin proof, hinged lockable doors, complete with electrolytic grade copper bus bars,internal wiring, colour coding, ferrules, Panel mounting MS Channels, fasteners, etc., RYB indication lamps,internal wirings, Digital voltmeter and Ammeterand other required accessories for the complete operation as per the Tangedco requirements. Necessary approval to be obtained from Tangedco before procurement including all associated control wiring cubicle shall be suitable for floor mounting, with painted Mild steelstand made of MS Angles.
142Incomer : 500 ams Porcelain rewireable fuse carrier with bus extension-3 nos. 3 nos of 230VLED indication lamps with 6A protection fuse. Outgoing metering compartment :12 nos, each comprising Space for mounting 3 phase 5-30amps 3 phase energy meter with base Hylum sheet. 3nos of 63amps rewireable fuse cutouts and 1 no of Neutral link. Outgoing MCB compartment:12 nos, each comprising 1 no.of 63amps 4 Pole MCB,C Curve, 10KA Busbar compartment: 50x6mm , electrical grade , copper bus bar, withinsulated with color coded as per standard,hardware for wire extension. 6 sq.mm PVC insulated copper conductor ,FRLS .wire for branch extension , and termination with copper lugs.
143Supply and Fixing of CPRI approved make EB metering panel, IP 54,made of 1.6mm thick Treated & powdercoated MS Sheet, compartmentalised, as per TNEB standard, for housing 3phaseEnergy meters and rewireable Fuse outletsin lockable compartments, outgoing 2/4 Pole MCB, fuse unit as incomer. ( 1 incomer + 12nosSingle phase, 1 no 3 phaseoutgoings ).The metering cubicle type, Free standing, floor mounted, single front, 14 SWG CRCA sheet steel, enclosed separate compartment for each feeder, front operated, Powder coated, indoor type dust and vermin proof, hinged lockable doors, complete with electrolytic grade copper bus bars,internal wiring, colour coding, ferrules, Panel mounting MS Channels, fasteners, etc., RYB indication lamps,internal wirings, Digital voltmeter and Ammeterand other required accessories for the complete operation as per the Tangedco requirements. Necessary approval to be obtained from Tangedco before procurement including all associated control wiring cubicle shall be suitable for floor mounting, with painted Mild steelstand made of MS Angles.
144Incomer : 200 ams Porcelain rewireable fuse carrier with bus extension-3 nos. 3 nos of 230V LED indication lamps with6A protection fuse. Outgoing metering compartment :12 nos, each comprising Space for mounting 3 phase 5-30amps 3 phase energy meter with base Hylum sheet. 3nos of 63amps rewireable fuse cutouts and 1 no Neutral link Outgoing MCB compartment:1 no, comprising Space for mounting 1 phase 5-30amps 3 phase energy meter with base Hylum sheet. 1no of32amps rewireable fuse cutouts and 1 no of Neutral link. Outgoing MCB compartment:13 nos, comprising 1 No of63amps4 Pole MCB,C Curve, 10KA 12Nos of32amps2 PoleMCB,C Curve, 10KA Busbar compartment: 30x6mm , electrical grade , copper bus bar, withinsulated with color coded as per standard,hardware for wire extension. 6 sq.mm PVC insulated copper conductor ,FRLS .wire for branch extension , and termination with copper lugs.
145Supply and Fixing of CPRI approved make EB metering panel, IP 54,made of 1.6mm thick Treated & powdercoated MS Sheet, compartmentalised, as per TNEB standard, for housing 1 phase Energy meters and rewireable Fuse outletsin lockable compartments, outgoing 2 Pole MCB, fuse unit as incomer ( 1 incomer + 11nos 1 no of Single phaseoutgoings ) .The metering cubicle type, Free standing, floor mounted, single front, 14 SWG CRCA sheet steel, enclosed separate compartment for each feeder, front operated, Powder coated, indoor type dust and vermin proof, hinged lockable doors, complete with electrolytic grade copper bus bars,internal wiring, colour coding, ferrules, Panel mounting MS Channels, fasteners, etc., RYB indication lamps,internal wirings, Digital voltmeter and Ammeterand other required accessories for the complete operation as per the Tangedco requirements. Necessary approval to be obtained from Tangedco before procurement including all associated control wiring cubicle shall be suitable for floor mounting, with painted Mild steelstand made of MS Angles.
146Incomer : 200 ams Porcelain rewireable fuse carrier with bus extension-3 nos. amd 3 nos of 230V LED indication lamps with 6A protection fuse. Outgoing metering compartment :11 nos, each comprising Space for mounting 1no of Single phase 5-30amps 3 phase energy meter with base Hylum sheet. 1no of 32amps rewireable fuse cutouts and 1 no of Neutral link Outgoing MCB compartment:13 nos, comprising 11 Nos of32amps , DP Pole MCB,C Curve, 10KA Busbar compartment: 30x6mm , electrical grade , copper bus bar, withinsulated with color coded as per standard,hardware for wire extension. 4sq.mm PVC insulated copper conductor ,FRLS .wire for branch extension , and termination with copper lugs.
147Supply and fixingof8 way verticalTPMCBsheetsteel Industrial Type TPMCB DB with IP54 Protection of surface type fitted with bus bars and neutral links with1 No. of 63A FP MCB as Incoming and 4 Nos.of32A,10KA Triple Pole MCB in Flush with wall and making good of the concealed portion with earth connection.( Industrial Type TPMCB DB with IP54 Protections)
148Supply and fixing of 4 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32 A 4P MCBas incoming and 3nos. of 16A-20A Triple pole MCBas outgoing and 3 nos of 10A SP MCB as Outgoing on wall with earth connection only.HigherEnd
149Supply and fixing of 8 way Horizontal Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 63A 4P MCBswitch as incoming and3 nos25amps DP RCCB , 30mA as outgoingand 10 nos of16A SP MCBand 8 nos of 10A SP MCB as outgoing in flush with wallwith earth connection only.HigherEnd
150Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no of 40 Amps 30 MA4 pole RCCBswitch as incoming and 1no of 16A SP MCBand 3 nos of 6A SP MCB as outgoing on wall with earth connection only. Higher End )
151Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no of 32 DP MCBswitch as incoming and 6nos of 10A SP MCBas outgoing on wall with earth connection only. Higher End
152Supply and fixing of 4 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no of 40A DP MCBswitch as incoming and 1no of 16A SP MCBand 1 no of 6A SP MCB as outgoing on wall with earth connection only. Higher End
153Supply and fixing of 32A 4P MCB in Metalsheet enclosurein surface / concealed configuration including andconnecting accessories with earth connection(For Washer / Drier Unit )
154Supply and laying of following XLPE armoured LTUG cable in a trench/Tray with suitable cable tie tag etc as required.
1553.5CX185sqmm Al.armoured LTUG Cable
1563.5CX70sqmm Al.armoured LTUG Cable
1574CX25sqmm Al. armoured LTUG Cable
1584CX16sqmm Al.armoured LTUG Cable
1594CX6sqmm Cu. armoured LTUG Cable
160Supply and clamping of following XLPE armoured LTUG cable on post or on wall MS-Clamps , Saddles, plugs, Screws etc., as required.
1613.5CX185sqmm Al.armoured LTUG Cable
1623.5CX70sqmm Al.armoured LTUG Cable
1633.5CX25sqmm Al. armoured LTUG Cable
1644CX16sqmm Al.armoured LTUG Cable
165Supply and fixing of double compression brass cable gland for following Aluminium conductorXLPE insulatedarmoured cable of 1100 V grade with earth connection.
1663.5CX185sqmm Al.armoured LTUG Cable
1673.5CX70sqmm Al.armoured LTUG Cable
1684CX25sqmm Al. armoured LTUG Cable
1694CX16sqmm Al.armoured LTUG Cable
1704CX6sqmm Cu. armoured LTUG Cable
171Supply and providing cable end termination of the following sizePVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete (copper sockets for copper cables and Alu. Sockets for alum. Cable)
1723.5CX185sqmm Al.armoured LTUG Cable
1733.5CX70sqmm Al.armoured LTUG Cable
1744CX25sqmm Al. armoured LTUG Cable
1754CX16sqmm Al.armoured LTUG Cable
1764CX6sqmm Cu. armoured LTUG Cable
177Supply and Run of 4 of 6 sq.mm. (84/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigidpipe concealed inwall and ceiling with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copperwire with painting of suitable colour.
178Supply and Run of 4 of 4 sq.mm. (56/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigidpipe Concealed inwall and ceiling with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copperwire and making good of the concealed portion withsuitable colour.
179Supply, run, testing and commissioning of2 Run x 2.5 sqmm and 1R of 1.5sq sqmm PVC insulated SC unsheathed Cu.Conductor of 1100V Grade in suitable Pvc conduit pipe onconcealed wall and ceiling with continuous earth wire connection with painting of suitable colour.
180Wiring with 2 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) ( points / Coil) Higher End.
181Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with with Module GI switch box in flush with wall with 6A one way module switch with module front plate continuous earth wire connection by 1 sq.mm. PVC insulated SC unsheathed copper wire and making good of the concealed portion with suitable colour for PVC concealed light (6 points per coil) (for rooms like bath, toilet & pumproom, etc.).
182Wiring with 3R x1.5 sq.mm. (22/0.3) and 1 run of 1.0 Sqmm PVC insulated single core unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A two way module switch with module front plate with continuous earth wire connection of 1 run of 1.0 Sq.mm wire and making good of the concealed portion with suitable colour for Concealed PVC pipe Stair case Light point Higher End
183Supply and fixing of 1no.6A two module socket , 1 no. 6/16A two module socket, 1 no. 6A one module switch, 1 no.16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI) in flush with wall with connections and Scope cover wall cutting , grouting , flushing and making good on the wall. Higher End.
184Supply and fixing of 1 no.6/16A two modulesocket , 1 no.16A one module switch with module cover plate (plastic) onsuitable module concealedBox (GI ) in flush with wallwith connections.Scope cover wall cutting , grouting , flushing and making good on the wall. Higher End.
185Supply and fixing of 2nos.6A two module 5 pin socket , 2 nos. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections.Scope cover wall cutting , grouting , flushing and making good on the wall. Higher End.
186Supply and fixing of single box type 4" 20W LED light fitting complete with Electronic Driver, with TW round blocks on wall or ceiling with PVC unsheathed copper leads from terminals to the fittings (Make : Philips/Crompton/Havelles )
187Supply and fixing of15WLED Bulb with Batten holder typecompletewith TW round blocks on wall or ceiling with PVC unsheathed copper leads from terminals to the fittings (Make : Philips/Crompton/Havelles )
188Supply and fixing of 65 mm dia. (2 -1/2") GI pipe (class B) of 6 metre length with 300mm x 300mm x 6mm MS base plate duly welded at the bottom with concreting with construction of masonary pedestal with suitable SMC box with door arrangement to house 6A SP MCB switch, 2/4 way connector on suitable hylem sheet and supply and fixing of 45W LEDStreet light fitting with LED (Higher end) with 1 metre 32mm dia. GI pipe (class B) Complete with suitable MS clamps for LED steet light fitting and SMC box with PVCunsheathed copper leads from SMC box to fitting and with painting of suitable colour.
189supply and fixing of 30W LED street light fitting with LED (Higher end) with 25 mm dia. GI pipe (class B) with 1 no. 25 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and withpainting.
190Supply and fixing ofpressure die cast aluminium housingBulk Head 10W LED fitting with IP65 protected withPVC unsheathed copper leads from terminals to the fitting. model equivalent to CromptonLBHE-10-CDL(Philips/bajaj/crompton/K.Lite )
191Supply and Fixing of10W 2"LED Tube Light Engineering plastic batten with white acrylic cover sleek design & high efficiency for wall & surface mounted applications with PVC unsheathed copper leads from terminals to the fitting.Equivalent to Model no: Make: ( Balaj , CAT Ref: BCLSB 10W W WH. (Make : Philips/Crompton/Havelles )
192Supply, Installation, Testing & Commissioning of40W LED LANDSCAPE LIGHT Fitting.The Light Fitting should be powder coated with high pressure die-cast aluminium LED housing. And the LED fixed on die-cast aluminum heat sink for proper thermal management.and the operating voltage range 140 – 270V AC, provided with open and short circuit protection and input surge voltage protection. Decorative post top for 360 degree Indirect light with IP 65 protection, Resistant to impact and corrosion. Glare-free andbetter uniformity. MAPLE LPTO-40-CDL/Mmake :Crompton Features and details Aesthetically designed and soft illumination effectumens :2450lm power:40W colour: multi colour Included components : post TopRate shall inclusive of necessary joint kit,glands,etc for loop in/outconnection suitable to outdoor application. Crompton CAT REF : - LPTO-40-WW-MEquivalent.
193Supply and fixing of 1200mm (48") sweep AC ceiling fan 5 star rated complete ( Higher end)with 2 module 100W fan step regulator (Higher end)with 600mmdown rod with fan clamp, and wiring to the neary by point with 1.5 sqmm FRLS , PVC insulated copper wires, including ncessaryaccessories and harwares as required.
194Supply and fixing of 300mm(12")sweep (Heavy duty) AC Exhaust fan complete with necessary wall opening and making good of the wall and wiring to the neary by point with 1.5 sqmm FRLS PVC insulated copper wires including ncessaryaccessories and harwares as required.
195Supply and fixing of louvers shutters arrangements for 300mm(12") sweep (light duty) AC exhaust fan,including ncessaryaccessories and harwares as required.
196Earthing as per the ISI specification with an earth electrode of 2.10 metre Class "B" GI pipe of dia not less than 50mm and 2 mtr long earth electrode of low carbon steel rod with 100 micron bonding and 25 kgs of carbon based environment friendly backfill compound and suitable clamp andwithcopper earth plate of size 125mm x 50mm x 6mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry
197Coil earth to street light poles with No.8 SWG GI wire of 11.5 metres of length in which 10 metres of total length compressed in to a coil of one meter length (75mm to 100mm dia) connected suitable with hexagonal earth bolt of size 8mm in to 25mm welded on the pole at one end with a coil position fixed on the earth.
198Supply, fabrication, of GI /Copper earth flatof following size in provided trench, clamping in wall, ceiling, with suitable Clamps/ saddles, connecting the joints through bracing / welding covering with with termination in the earth pits, Panels, Distribution boards and equipments with bitumen paint including accessories wooden plugs, screws, fastener etc., all inclusive
19940 mm x 6mm GI Flat ( SD-77 )
20025 mm x 6mm GI Flat ( SD-77 )
201No8 SWG copper (M-1571)
202No8 SWG GI
203LIGHTING ROD Supply of Early Streamer Emission Air Terminal (ESEAT). Model: S The ESEAT has corrosion resistant stainless chrome body made up of AISI 316 grade of height 0.50 metres capable of working in hazardous atmosphere. The Air terminal is non-radioactive and requires no special licensing. The unit is fully autonomous (no battery, no external power supply is required ), collects energy from the ambient electric field.The ESEAT model has been tested in a high voltage laboratory in accordance with NFC 17 102 in order to measure the average gain in triggering. The average gain in triggering time (?Ts) obtained during the lab test for the offered model is 60 µs. The ESEAT works on negative as well as positively polarized discharges. ESEAT has been tested for such discharges in Central Power Research Institute (CPRI). A dedicated tester is avilable to test the healthiness of the ESEAT on request (Page No. 37, Point No. 3 of Clause 8.6 of the Revised NFC 17-102 version 2011 ). ESEAT Model : S - Radius of protection : 46 Metres Level of protection considered for the Project-II level
204MOUNTING STRUCTURE Supply of Standard / Special Mounting Structure of height 4.5 mts. pipe, and 300 x 300 x 8mm MS plate, 3 mts. 48mm OD class C GI outer pipe,1.8 mtr, 38mm OD inner pipe, for roof mounting on concrete base and with FRP adapter
205DOWN CONDUCTOR Supply and run of 25mm x 6mm GI Flat Down Condutor with necessary clamps / supports on wall / floor / ground for earth connection
206TEST LINK Supply of Test Link Box for each Down conductor in order to disconnect the earth termination system to enable measurement of resistance
207Installations charges & trasportation charges forlightening Protection System
208Supply and insallation maintenance free GI Earthing System comprising of 50mm dia and 2 mtr. long earth electrode of low carbon steel rod with 100 micron bonding and 25 kgs. of carbon based environment friendly backfill compound and suitable clamp
209SURGE PROTECTION Supply and insallation Cabinet Type Class 1 and 2 Combined Model SPD to arrest surges and overvoltages in the power line due to lighning switching action etc. they must be installed in the incoming MCC panel / DB of the respective buling in parallel to the power circuit. Model: PSV4-12.5/400TT (3 phase power network)
210First Aid Box complete with all First Aid Medicines (M-1977)
211Shock Treatment Chart fixed in glass frame(M-1978)
212Danger Board as required by the Electrical Authorities(M-1981)
213Fire Extinguisher Co2, 4.5 kg. confirming to TAC Norms(M-1982)
2142m x 1m Rubber Mat suitable for 11 KV installation confirming to IS (M-1976)
215CCTV
216Supply, Installation, Testing and commissioning of 32 channel 8 SATA NVR, with 6T Hard Disk Drive 4 nos, New logical and visualized GUI design Dual-OS design to ensure high reliability of system running, ANR technology to enhance the storage reliability when the network is disconnected,Configurable normal or hot spare working mode to constitute an N+1 hot spare system Video Input and Transmission, Connectable to the third-party network cameras Compression and Recording, H.265+ compression effectively reduces the storage space by upto 75%, Full channel recording at up to 12MP resolution HD Video Output ? HDMI1 / VGA1 outputs provided ? HDMI1 Video output at up to 4K ( 3840 × 2160 ) resolution Storage and Playback, Upto 16 SATA interfaces and 1 eSATA interface for HDD connection, Support upto 10TB capacity for each HDD, Smart search for efficient playback. and smart playback to improve the playback efficiency,Supports VCA search for fire / ship /temperature/temperature difference detection triggered video files, POS information overlay on live view and playback, POS triggered recording and alarm Network & Ethernet Access ? Hik-Connect for easy network management, 2 Gigabit Ethernet network interfaces. (Make : Hikvision / Dahua / Sony
217Supply of 8MP, Internet Protocol fixed BULLET CAMERA with following specification: ?1/2.5" Progressive Scan CMOS, ? 3840 × 2160 @15 fps,2.8/4 mm fixed lens,01 lux @ (F1.2, AGC ON), 0.028 lux @(F2.0, AGC ON), 0 lux with IR, H.265+, H.265, H.264+, H.264, 2 Behavior analyses ( Line crossing detection, intrusion detection) ? Face Detection ? 120dB WDR, ? BLC/3D DNR/ROI, IP67 complied ?On-board Storage -Built-in micro SD/SDHC/SDXC card slot, up to 128 GB, ? Shutter Speed 1/3 s to 1/100,000 s, ? 3-Axis Adjustment Pan: 0° to 360°, tilt: 0° to 100°, ? rotate: 0° to 360°, 2.8 mm, ? horizontal FOV: 102°, vertical FOV: 53°, diagonal FOV: 124°, ?Lens Mount M12 ? IR Range I5: up to 50 m, ? Image Settings Rotate mode, saturation, brightness, contrast, sharpness adjustable by client software or web browser, ? Power Consumption and Current-12 VDC, 0.7 A, max. 7.5W PoE: (802.3af, 36V to 57V), 0.3 A to 0.2 A, max. 9W ? Camera out fitted with metal housing so as to prevent the lens from damages during physical abuse. (Make: Dahua/Panasonic)(Rate as per quotation enclosed)
218Supply, Installation, Testing and Commissioning of 55" smart LED TV with following specifications a) Full HD 1920 x1080 (4K monitor) b) IPS pannel c) Slim back light LED module d) 900 PMI e) Triple XD engine f) Dynamic scanning g) ANR h) True colour generator i) 8modes of picture j) picture wizardIII k) Real cinema 24P l) HDMI -3nos m) USB -3nos n) Built in LAN o) Magic remote p) Dimension 1242 x 724 x 55.1min(37). (Make: Sony/ LG /Samsung).
219Supply and fixing of outdoor4X6PVC box with 102mm x 77mm x 102mm with all fixing accessories.
220Supply and Clamping of CAT 6 armoured cable in suitable PVCPipe 1" thick on wall / ceiling with connected PVC accessories with clamps, saddles etc., complete. (Between ethernet switch to camera and radio modem)i. Application : Primary (Campus), Secondary (Riser), Tertiary(Horizontal) IEEE 802.3 : 10Base-T; 100Base-T; 1000Base-T IEEE 802.5 16 MB; ISDN; TPDDI; ATM ii. Standards: ISO/IEC 11801 2nd ed.; IEC 61156-5 2nd EN 50173-1; EN 50288-6-1,EIA/TIA 568C.2, RoHS Compliant. Fire Rating: PVC : IEC 60332-1. iii. Conductor - Bare Copper Wire iv. Insulation - Polyethylene v. Twisting - 2 Cores to the pair vi. Cable lay up - 4 Core to the pair It has diameter of (23 AWG) 0.550 ± 0.015.Insulation : Polyethylene.GI wire of size is 0.90 ± 0.030mm.
221Fixing and Termination of CAT 6 Cable RJ 45Jack Single Point( Point to Point ) Crimping, Testing and arrangement charges.
222Supply, run, testing and commissioning of2 Run x 2.5 sqmm and 1R of 1.5sq sqmm PVC insulated SC unsheathed Cu.Conductor of 1100V Grade in suitable Pvc conduit pipe onconcealed wall and ceiling with continuous earth wire connection with painting of suitable colour.
223Supply and fixing of POE 24 port switch10/ 100 / 1000 Base -T / 2 x 1000Base-FX / 20Gbps bandwidth / IEEE803.af/at compliant PoE+ / RJ45 supports auto MDI/MDI-X function / Auto negotiation speed, half/full-duplex / Store and forward / Max packet size: 10kbytes / Wide range power design (12~56VDC) / Operating temperature (-40 °C ~ +75 °C) / Reverse polarity protection / Resettable fuse to protect against overcurrent / IP-40 protection / EFT protection for power line.
224Supply and fixing of POE 8 port switch10/ 100 / 1000 Base -T / 2 x 1000Base-FX / 20Gbps bandwidth / IEEE803.af/at compliant PoE+ / RJ45 supports auto MDI/MDI-X function / Auto negotiation speed, half/full-duplex / Store and forward / Max packet size: 10kbytes / Wide range power design (12~56VDC) / Operating temperature (-40 °C ~ +75 °C) / Reverse polarity protection / Resettable fuse to protect against overcurrent / IP-40 protection / EFT protection for power line. (Make: DLINK,NETGEAR/ TPLINK)
225Supply and fixing of Out Door Wheather Proof Box 2Ft x 2Ft Out Door Wheather Proof Box 2Ft x 2Ft
226Supply and Fixing of Rack with Accessories -Higher end 42 U Rack with LNS unit and fan extra for the above rack.
227Supply and fixing of 2 feet CCTV Camera Stand with attachment fittings as follows: * Weather heads and couplings * Cabinet mounting fittings, plates, brackets as needed. * Reinforced couplings for wire entrances to cabinets.
228Supply and Instalatin for 2KVA UPS with Battery, Single Phase UPS (Single Phase In & Single Phase Out) Capacity - System with Battery - 2Hours back up
229Supply and Instalatin for 1KVA UPS with Battery, Single Phase UPS (Single Phase In & Single Phase Out) Capacity - System with Battery - 1 Hours back up
230Supply,Erection of 6mLengthpole with base plate of size 250x250x6mm as per IS-875 with following specification. Pole Outter dia -76.10mm x 3.65mm Thick x 6 meter.
231Supply and filling in foundation and basement with M sand / filling sand in layers of not more than 15cm thick well watered, rammed and consolidated etc., complete as per standard specification.
232Providing and relaying Plain Cement Concrete 1:2:4 (One cement Two sand and ten broken Machine crushed stone jelly ) using HBG Machine crushed stone jelly of size 20mm gauge for founding and basement including de-watering if found necessary and laid in layers of not more than 15cms thick etc., complete complying with standard specification and as directed by the departmental officers.