| Sl. No. | Item Description |
| 1 | Section- I Civil Works |
| 2 | 5.1.1Earthwork in excavation in foundation trenches in ordinary soil(vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 m includingall lifts, levelling , ramming the foundation trenches, removing roots of trees, serbs all complete as per approved design,building specification & direction of E/I. |
| 3 | 5.1.2Extra for earthwork in hard soil as per specification and direction of E/I. ( vide classification of soil item-B) |
| 4 | 5.1.7Filling in foundation trenches and plinth layers not exceeding 150 mm thick well watered rammed fully compacted and fine dressed withearth obtained after cutting with in a lead of 50M and lift of 1.5M all complete as per building specification and directionof E/I ( Mode of measurement compacted volume) |
| 5 | 5.1.10Providing coarse clean local sand in filling in foundation trenches or in plinth including ramming and watering in layer not exceeding 150mm thick with all leads and 1.5M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer Incharge (Mode of measurement compacted volume) |
| 6 | 5.1.8Filling in foundation trenches and plinth layers not exceeding 150 mm thick well watered rammed fully compacted and fine dressed withearth obtained after cutting with in a lead of 50M and lift of 1.5M all complete as per building specification and directionof E/I ( Mode of measurement compacted volume) |
| 7 | 5.3.1Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :5.3.1.41:3:6(1Cement:3coarsesand(zone-III):6gradedstoneaggregate40mm nominal size) |
| 8 | 5.3.1Providing and laying in position cement cocrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level5.3.1.21:2:4 (1 cement : 2 coarse sand (zone -III ) : 4 graded stone aggregate 20 mm nominal Size) |
| 9 | 5.6.1Providing designation 75 A one brick flat soling joints files with local sand including cost of watering taxes royalty all complete as per building specefication and direction of E/I |
| 10 | 5.3.9 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level.5.3.9.1 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 11 | 5.3.17.1Centering and Shuttering including strutting, propping etc. And removal of form for Foundation, footing, bases of column, etc. For mass concrete |
| 12 | 5.3.10R.C.C. Work in wall (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, column, pillars, piers, abutments, posts and stru etc. Above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size) |
| 13 | 5.3.17.6Centering and Shuttering including strutting, propping etc. And removal of form for Column, Pillars, Piers, Abutments, posts and Struts |
| 14 | 5.3.11R.C.C. Work in beams, suspended floors, roofs having slope upto 15° landing, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size) |
| 15 | 5.3.17.21Centering and Shuttering including strutting, propping etc. And removal of form for Lintel, beams. Plinth beams, girders, bressumers and cantilevers with water proof ply 12mm thick |
| 16 | 5.2.6Providing designation 75 B brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l. |
| 17 | 5.3.5Providing and laying damp proof course 50mm thick with cement concrete 1:2:4 ( 1 cement : 2 coarse sand (zone III) : 4 graded stone aggregate 20mm nominal size). |
| 18 | 5.2.14Providing designation 75A brick work in CM (1:6) in superstructure with approved quality of clean coarse & of F.M. 2.5 including providing 10mm thick mortar joints cost of screening, racking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 19 | 5.2.23Providing designation 125 mm thick reinforced designation 75 A brick work in C.M (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, carriage of materials , scafolding, raking out joints to 15 mm depth, curing, taxes and royalty ( but excluding the cost of reinforcement) all complete as per building specification and direction of E/l. |
| 20 | 5.3.11R.C.C. Work in beams, suspended floors, roofs having slope upto 15° landing, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size) |
| 21 | 5.3.17.21Centering and Shuttering including strutting, propping etc. And removal of form for Lintel, beams. Plinth beams, girders, bressumers and cantilevers with water proof ply 12mm thick |
| 22 | 5.3.11R.C.C. Work in beams, suspended floors, roofs having slope upto 15° landing, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size) |
| 23 | 5.3.17.21Centering and Shuttering including strutting, propping etc. And removal of form for Lintel, beams. Plinth beams, girders, bressumers and cantilevers with water proof ply 12mm thick |
| 24 | 5.3.11R.C.C. Work in beams, suspended floors, roofs having slope upto 15° landing, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size) |
| 25 | 5.3.17.19Centering and Shuttering including strutting, propping etc. And removal of form for Weather shade, Chajja, corbels etc. Including edges |
| 26 | 5.3.11R.C.C. Work in beams, suspended floors, roofs having slope upto 15° landing, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size) |
| 27 | 5.3.17.20Centering and Shuttering including strutting, propping etc. And removal of form for Suspended floors, roofs, landings, balconies and acces platorm with water proof ply 12mm thick |
| 28 | 5.3.11R.C.C. Work in beams, suspended floors, roofs having slope upto 15° landing, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size) |
| 29 | Providingtor steel reinforcement TMT FE 500 of following dia. rods as per approved design and drawing includingcarriage of bars to work site, cutting, bendingandbinding with annealedwirewithcostofwire, removal ofrustplacingtherods in position all complete as perbuilding specification and direction and direction of E/I.(Only valid for TATA TISCON / SAIL). |
| 30 | 5.5.4Providing Tor steel reinforcement of 8 mm dia rods as perapproved design and drawing excluding carriage of bars to work site cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complet |
| 31 | 5.5.5a10mm dia- TMT Fe 500 (Onaly valid for SAIL, TATA Stee, JSPL, Electro Steel Ltd and Vizal Steel) |
| 32 | 5.5.5b12mm dia- 20mm dia TMT Fe 500 (Onaly valid for SAIL, TATA Stee, JSPL, Electro Steel Ltd and Vizal Steel) |
| 33 | 5.7.3Providing 12mm thick cement plaster (1:6)with clean coarse sand of F.M. 1.5 and including cost of screening, curingwith all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I |
| 34 | 5.7.6Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5including screening, curingwithall leadsand liftsof water, scaffolding taxes and royalty all complete as per building specification and direction of E/l. |
| 35 | DSR 13.80Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 36 | 5.8.18Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding, washing of floors and taxes all complete as per building specification and direction of E/l. |
| 37 | DSR 13.45.1Finishing walls with textured exterior paint of required shade :13.45.1 New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 38 | DSR 13.46.1Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primerapplied @ 2.20 kg/ 10 sqm) |
| 39 | DSR11.41 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete11.41.3 Size of Tile 800x800 mm |
| 40 | D.S.R 11.46 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.11.46.3 Size of Tile 800x800 mm |
| 41 | DSR 11.39Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4Coarse sand), including grouting the joints with white cement and matching pigments etc., complete. |
| 42 | DSR 8.31Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 43 | DSR11.56Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with whitecement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.11.56.1 Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 44 | DSR 8.2.2.2Providing and fixing 18mm thick mirror polished, machine cut for kitchen platforms, vanity counters facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 Cement : 4 coarse sand) with joints treated with white cement ,mixed with matching pigment, epoxy touch ups, including rubbing ,curing etc. complete at all levels. GRANITE OF ANY COLOUR AND SHADE -Area of slab Over 0.5 sqm . |
| 45 | DSR12.45 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : |
| 46 | 12.45.4 Fully Perforated Gypsum Plaster Board of size 1200 x2400x12.5 mm having approx. 15 % perforated area withperforation size and pattern as approved by the Engineer-in-charge and as per manufacturer\"s specification, withall 4 side tapered and backed by acoustical tissue withNRC value not less than 0.60 |
| 47 | DSR 8.3Providing edge moulding to 18 mm thick marble stone counters, Vanitiesetc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.8.3.2 Granite work |
| 48 | DSR 9.147D Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) |
| 49 | 9.147D.4Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Areaof window above 1.75 sqm). |
| 50 | 5.5.12Supplying , fittingand fixingM.S. grill made of20x6 mm flatas per approveddesign and drawing properly fabricatedwith jointscontinuousfittedwelded andfinishedsmooth , hoisting asper building specification anddirection of E/I. |
| 51 | 5.4.1Supplying, fitting and fixing good quality well dressed and well seasoned sal wood work in chaukhat in doors window, sky light fanlight and celevitial window opening including wedge over clamps all including application of two coats of wood preservative of approved quality on the surface, building walls and lintel all complete as per building specification and direction of E/I. |
| 52 | 5.4.40Supplying, fitting and fixing 30mm thick solid core type non-decorative single leaf flush door shutter in door and windowswith black board core blended with high qualityphenol formal dehydes synthetic resine both side commercial veneered of standard make with oxidised iron fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I. |
| 53 | 5.4.9Supplying, fitting and fixing 38mm , thick good quality well dressed and well seasoned teak wood fully paneled shutter in doors and window with 25mm, thick panels with one side plain and other side chamfered with aluminium fittings such as hinges, sliding door, bolts, tower bolts, handled or rings, hooks and eyes, cleats, sand blocks as per schedule, taxes and royalty all complete as per building specification and direction of E/I. |
| 54 | 9.101.2/D.S.R Providing and fixing aluminium hanging floor door stoppers ISI marked anodized (anodic coating not less than grade Ac 10 as per I.S. 1868) transparent or dyed to required colour and shade with necessary screws etc. complete.Twin rubber stopper |
| 55 | 9.127Providing & Fixing decorative high pressure laminated sheet of plain /wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. |
| 56 | M-210 (iii)Supplying of 12 mm thick Ply wood( Green/century/national orequivalant make) |
| 57 | 5.8.41Providingprimer onecoat of red lead paint ofapprovedmake over steel surface including preparing the surface after cleaningremoving dirt, scales, grease and sand papering, including cost of scaffolding etc. all complete as per building specification direction of E/I. |
| 58 | 5.8.45Providing 2 coats of Synthetic Enamel Paint of approved shade and make over steel surface grills & railings including cleaning the surface thoroughly scaffolding and taxes all complete as per building specification and direction of E/I. |
| 59 | DSR 22.5Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparationof surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 60 | DSR 10.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fastenersetc.). |
| 61 | DSR 12.41.2Providing & fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS 13592 Type A including jointing with seal ring conforming to IS 5382 leaving 10mm gap for thermal expansion. Single socketed pipes. 110mm dia |
| 62 | DSR 12.42Providing & fixing on wall face unplasticised- PVC moulded fittings/accessories for unplasticised - Rigid PVC rain water pipes conforming to IS 13592 Type A including jointing with seal ring conforming to IS 5382 leaving 10mm gap for thermal expansion |
| 63 | 12.42.5.2Bend-110 mm |
| 64 | 12.42.6.2Shoe - 110mm |
| 65 | DSR 12.43.2Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 66 | 5.10.33Providing 250mm wide brick drain in cement mortar (1:6) with av. 150mm. Clear depth and 250mm apron including cost of earthwok involved with 75mm cement concrete (1:4:3) over one brick designation 75A, flat soling in proper grade and slope at th base, he drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. |
| 67 | DSR 4.17Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. |
| 68 | DSR 22.22AProviding and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge. |
| 69 | DSR 22.14Grading roof for water proofing treatment with22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 20mm nominal size) |
| 70 | Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I. |
| 71 | Bricks(1k+7p)= 8 km |
| 72 | Local Sand (3 km) |
| 73 | Coarse sand (1K+50P = 51 Km) |
| 74 | Stone Chips (1K+34P = 35 km) |
| 75 | Cement(5 km) |
| 76 | Steel (5 km) |
| 77 | Earth( 3 KM) |
| 78 | Gazebo |
| 79 | 5.1.1Earthwork in excavation in foundation trenches in ordinary soil(vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 m includingall lifts, levelling , ramming the foundation trenches, removing roots of trees, serbs all complete as per approved design,building specification & direction of E/I. |
| 80 | 5.1.2Extra for earthwork in hard soil as per specification and direction of E/I. ( vide classification of soil item-B) |
| 81 | 5.1.7Filling in foundation trenches and plinth layers not exceeding 150 mm thick well watered rammed fully compacted and fine dressed withearth obtained after cutting with in a lead of 50M and lift of 1.5M all complete as per building specification and directionof E/I ( Mode of measurement compacted volume) |
| 82 | 5.1.10Providing coarse clean local sand in filling in foundation trenches or in plinth including ramming and watering in layer not exceeding 150mm thick with all leads and 1.5M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer Incharge (Mode of measurement compacted volume) |
| 83 | 5.1.8Filling in foundation trenches and plinth layers not exceeding 150 mm thick well watered rammed fully compacted and fine dressed withearth obtained after cutting with in a lead of 50M and lift of 1.5M all complete as per building specification and directionof E/I ( Mode of measurement compacted volume) |
| 84 | 5.3.1Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :5.3.1.41:3:6(1Cement:3coarsesand(zone-III):6gradedstoneaggregate40mm nominal size) |
| 85 | 5.3.1Providing and laying in position cement cocrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level5.3.1.21:2:4 (1 cement : 2 coarse sand (zone -III ) : 4 graded stone aggregate 20 mm nominal Size) |
| 86 | 5.6.1Providing designation 75 A one brick flat soling joints files with local sand including cost of watering taxes royalty all complete as per building specefication and direction of E/I |
| 87 | 5.3.9 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level.5.3.9.1 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 88 | 5.3.17.1Centering and Shuttering including strutting, propping etc. And removal of form for Foundation, footing, bases of column, etc. For mass concrete |
| 89 | 5.3.10R.C.C. Work in wall (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, column, pillars, piers, abutments, posts and stru etc. Above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size) |
| 90 | 5.3.17.6Centering and Shuttering including strutting, propping etc. And removal of form for Column, Pillars, Piers, Abutments, posts and Struts |
| 91 | 5.3.11R.C.C. Work in beams, suspended floors, roofs having slope upto 15° landing, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size) |
| 92 | 5.3.17.21Centering and Shuttering including strutting, propping etc. And removal of form for Lintel, beams. Plinth beams, girders, bressumers and cantilevers with water proof ply 12mm thick |
| 93 | 5.2.6Providing designation 75 B brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l. |
| 94 | 5.3.5Providing and laying damp proof course 50mm thick with cement concrete 1:2:4 ( 1 cement : 2 coarse sand (zone III) : 4 graded stone aggregate 20mm nominal size). |
| 95 | 5.2.14Providing designation 75A brick work in CM (1:6) in superstructure with approved quality of clean coarse & of F.M. 2.5 including providing 10mm thick mortar joints cost of screening, racking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 96 | 5.3.11R.C.C. Work in beams, suspended floors, roofs having slope upto 15° landing, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size) |
| 97 | 5.3.17.21Centering and Shuttering including strutting, propping etc. And removal of form for Lintel, beams. Plinth beams, girders, bressumers and cantilevers with water proof ply 12mm thick |
| 98 | 5.3.11R.C.C. Work in beams, suspended floors, roofs having slope upto 15° landing, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size) |
| 99 | 5.3.17.19Centering and Shuttering including strutting, propping etc. And removal of form for Weather shade, Chajja, corbels etc. Including edges |
| 100 | 5.3.11R.C.C. Work in beams, suspended floors, roofs having slope upto 15° landing, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size) |
| 101 | 5.3.17.20Centering and Shuttering including strutting, propping etc. And removal of form for Suspended floors, roofs, landings, balconies and acces platorm with water proof ply 12mm thick |
| 102 | 5.7.3Providing 12mm thick cement plaster (1:6)with clean coarse sand of F.M. 1.5 and including cost of screening, curingwith all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I |
| 103 | 5.7.6Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5including screening, curingwithall leadsand liftsof water, scaffolding taxes and royalty all complete as per building specification and direction of E/l. |
| 104 | DSR 13.80Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 105 | 5.8.18Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding, washing of floors and taxes all complete as per building specification and direction of E/l. |
| 106 | DSR 13.45.1Finishing walls with textured exterior paint of required shade :13.45.1 New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 107 | Providingtor steel reinforcement TMT FE 500 of following dia. rods as per approved design and drawing includingcarriage of bars to work site, cutting, bendingandbinding with annealedwirewithcostofwire, removal ofrustplacingtherods in position all complete as perbuilding specification and direction and direction of E/I.(Only valid for TATA TISCON / SAIL). |
| 108 | 5.5.4Providing Tor steel reinforcement of 8 mm dia rods as perapproved design and drawing excluding carriage of bars to work site cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complet |
| 109 | 5.5.5a10mm dia- TMT Fe 500 (Onaly valid for SAIL, TATA Stee, JSPL, Electro Steel Ltd and Vizal Steel) |
| 110 | 5.5.5b12mm dia- 20mm dia TMT Fe 500 (Onaly valid for SAIL, TATA Stee, JSPL, Electro Steel Ltd and Vizal Steel) |
| 111 | DSR 13.46.1Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primerapplied @ 2.20 kg/ 10 sqm) |
| 112 | DSR11.41 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete11.41.3 Size of Tile 800x800 mm |
| 113 | D.S.R 11.46 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.11.46.3 Size of Tile 800x800 mm |
| 114 | DSR 8.31Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 115 | DSR 8.2.2.2Providing and fixing 18mm thick mirror polished, machine cut for kitchen platforms, vanity counters facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 Cement : 4 coarse sand) with joints treated with white cement ,mixed with matching pigment, epoxy touch ups, including rubbing ,curing etc. complete at all levels. GRANITE OF ANY COLOUR AND SHADE -Area of slab Over 0.5 sqm . |
| 116 | DSR 8.3Providing edge moulding to 18 mm thick marble stone counters, Vanitiesetc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.8.3.2 Granite work |
| 117 | DSR 9.147D Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) |
| 118 | 9.147D.4Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Areaof window above 1.75 sqm). |
| 119 | 5.5.12Supplying , fittingand fixingM.S. grill made of20x6 mm flatas per approveddesign and drawing properly fabricatedwith jointscontinuousfittedwelded andfinishedsmooth , hoisting asper building specification anddirection of E/I. |
| 120 | 5.8.41Providingprimer onecoat of red lead paint ofapprovedmake over steel surface including preparing the surface after cleaningremoving dirt, scales, grease and sand papering, including cost of scaffolding etc. all complete as per building specification direction of E/I. |
| 121 | 5.8.45Providing 2 coats of Synthetic Enamel Paint of approved shade and make over steel surface grills & railings including cleaning the surface thoroughly scaffolding and taxes all complete as per building specification and direction of E/I. |
| 122 | DSR 10.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fastenersetc.). |
| 123 | 5.10.33Providing 250mm wide brick drain in cement mortar (1:6) with av. 150mm. Clear depth and 250mm apron including cost of earthwok involved with 75mm cement concrete (1:4:3) over one brick designation 75A, flat soling in proper grade and slope at th base, he drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. |
| 124 | DSR 4.17Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. |
| 125 | DSR 22.22AProviding and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge. |
| 126 | DSR 22.14Grading roof for water proofing treatment with22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 20mm nominal size) |
| 127 | Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I. |
| 128 | Bricks(1k+7p)= 8 km |
| 129 | Local Sand (3 km) |
| 130 | Coarse sand (1K+50P = 51 Km) |
| 131 | Stone Chips (1K+34P = 35 km) |
| 132 | Cement(5 km) |
| 133 | Steel (5 km) |
| 134 | Earth( 3 KM) |
| 135 | Water Supply and Sanitary |
| 136 | 3.2.1Supplying, fitting and fixing vitreous white glazed earthen ware I.W.C. of parry Hindustan or any other I.S.S. approved make with100mm H.C.I. \"P\" trap 15 litres C.I. pull and let go flushing cistern of names or other I.S.S. equivalent make, complete with all fittings, C.I. or C.C. brackets 32mm alkathene/ P.V.C. telescopic flush, pipe about 2 M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair of vitreous white glazed earthenware footrest to be fixedin floor 15mm C.I. body brass spindle stop cock of weight not less than 50 grms, 15mm P.V.C. connection pipe 450 mm long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specificatin and direction of E/I. (A) 580 mm long(C) with 10 ltrs. low level P.V.C. Cistern |
| 137 | 3.2.2Supplying fitting and fixing 40mm high vitreous white glazed earthen E.W.C with Ptrap of parry/Hindustanor any other approved I.S.S make ineluding supplying and fixing 15 litersC.I mosquito proof low down flushing cistern of approved make with complete fittings with C.I handle and R.S or bracket wit h telescopic flush pipe with brass eoupling and plumbers joints spindle stop coci of approved quality weight not less than 450grams 15mm P.V.C alkathene pipe 45cm long with brass coupling at both ends and white /black plastic solid state seal and lead of commander / cuckoo or other I.S.S make with hinges or screws etc painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide priming all complete as per specification and direction of E/I. (I) With \"P\" trap(b) 10 Lit Law Lavel PVC Cistern. |
| 138 | DSR 17.7Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brasspillar taps, 32 mm C.P. brass waste of standard pattern, includingpainting of fittings and brackets, cutting and making good the wallswherever require:17.7.9 White Vitreous China Surgeon type wash basin of size660x460 mm with single 15 mm C.P. brass pillar tapswith elbow operated levers ISI Marked |
| 139 | DSR 17.8Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 140 | DSR 17.70Providing and fixing PTMT Bottle Trap for Wash basin and sink. 17.70.1 Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms |
| 141 | DSR 18.52.1Providing and fixing C.P. brass Stop Cock (concealed) of standard designand of approved make conforming to IS 8931. 18.52.115mm nominal bore |
| 142 | DSR 18.64Providing and fixing PTMT swivelling shower, 15 mm nominal bore,weighing not less than 40 gms |
| 143 | DSR 17.72Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. |
| 144 | DSR 17.73Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.17.73.1 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms |
| 145 | 3.2.3Suppling, Fitting and Fixing Flat Back or angular, liped front viterouswide glazed earthen were urinal of Hindustan / Parrywere or any other approved ISI marked with 5 litres capacity C.I. automatic flushing cistern of reliance for any other ISI approved make with all fittings with CI or RS Brackets, Standard Size G.I. flush pipe with fitting clams 15mm CI buddy brass spindle stop cock of approved quality weight not less than 400 grms, 15 mm PVC / alkthene pipe 450 mm long with brass coupling at both ends and doing plumber joints including painting of exposed part with two coats of approved paint over a primer coat of red oxide cutting wall and floor, making good the same etc. all complete as per specification and direction of E/I.(a) Flat back or standing corner (600mm x 350mm) |
| 146 | D.S.R 18.50Providing and fixing C.P.brass long body bib cock of approved quality conforming to standard and weight not less thain 810gms. |
| 147 | 18.50.1 15mm nominal bore |
| 148 | D.S.R. 18.53Providing and fixing C.P. brass angle valve for , gyser & others points of approved quality conforming to IS 8931. 18.53.1 15mm nominal bore, approved brand C.P. fittings. |
| 149 | DSR 18.65Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. |
| 150 | D.S.R. 18.17 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end ) |
| 151 | DSR 18.17.232 mm nominal bore. |
| 152 | D.S.R. 18.18 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete. |
| 153 | DSR 18.18.220mm nominal bore |
| 154 | DSR 18.18.325mm nominal bore |
| 155 | DSR 17.31Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 156 | DSR 18.58Providing and fixing PTMT grating of approved quality and colour. |
| 157 | DSR 18.58.2 Rectangular type with openable circular lidDSR 18.58.2.1150 mm nominal size square 100 mm diameter of the inner hinged round grating |
| 158 | DSR 17.10Providing and fixing stainless steel A ISI 304(18/8) kitchen sink as per I.S.13983 with C.I. Brackets stainless steel plug 40mm including painting of fittings and brackets cutting and making goods the walls wherever required :DSR 17.10.1 Kitchen sink with drain boardDSR 17.10.1.2510x1040 mm bowl depth 225 mm |
| 159 | DSR 18.74Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour.18.74.2 15 mm nominal bore with 45 cm length. |
| 160 | DSR 17.22BProviding and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.(a) 15 mm nominal dia |
| 161 | DSR 12.41Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes. |
| 162 | 12.41.1 75 mm diameter |
| 163 | 12.41.2 110 mm diameter |
| 164 | D.S.R 12.42 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 165 | DSR 12.42.1.1 Coupler 75 mm |
| 166 | DSR 12.42.1.2Coupler 110 mm |
| 167 | DSR 12.42.2 Single pushfit Coupler |
| 168 | DSR 12.42.2.175 mm |
| 169 | DSR 12.42.2.2110 mm |
| 170 | DSR 12.42.3 Single tee with door |
| 171 | DSR 12.42.3.175 X 75 X 75 mm |
| 172 | DSR 12.42.3.2110 X 110 X 110 mm |
| 173 | DSR 12.42.4Single tee without door |
| 174 | DSR 12.42.4.1 75 X 75 X 75 mm |
| 175 | DSR 12.42.4.2110 X 110 X 110 mm |
| 176 | DSR 12.42.5Bend 87.5° |
| 177 | DSR 12.42.5.1 75 mm Bend |
| 178 | DSR 12.42.5.2110 MM Bend |
| 179 | D.S.R. 12.42.6 SHOE - 110MM |
| 180 | DSR12.42.6.1 75 MM |
| 181 | DSR12.42.6.2110 MM Shoe |
| 182 | D.S.R.12.43 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 183 | DSR 12.43.175 mm |
| 184 | DSR 12.43.2110 mm |
| 185 | DSR 18.8Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes joining of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of E/I.(Approved Brand - ASTRAL/ SUPREME) |
| 186 | Concealed work including cutting chases and making good the wall etc.. |
| 187 | DSR 18.8.2.20mm dia |
| 188 | DSR 18.7Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. |
| 189 | Exposed on Wall |
| 190 | DSR 18.7.325 mm nominal outer dia Pipes |
| 191 | DSR 18.7.432 mm nominal outer dia Pipes |
| 192 | DSR 19.6Providing and laying non- pressure NP2 class ( light duty ) R.C.C. pipes with collars jointed with still mixture of cenent mortar in the proportion of 1:2 ( lcement : 2 fine sand ) including testing of joints etc. complete. |
| 193 | DSR 19.6.2150 mm dia R.C.C. pipe |
| 194 | D.S.R. 19.30Constructing brick masonary chamber for Underground C. I. Inspection Chamber and bend with 75 class designation bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. Cover with frame (light duty) 455X610 mm internal dimensions, total weight of cover with frame to be not less than 38 KG. (weight of cover 23 kg. and weight of frame 15 kg) RCC top slab with 1:1.5:3 mix (1 cement:1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 mix (1 cement:5 coarse sand :10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm th. with cement mortar 1:3 (1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: |
| 195 | 19.30.1.1Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 196 | Analysed and ApprovedProviding and Fixing Hand Shower ( Health Faucet) ( ABS Body) ALD-CHR-585 Jaquar made.Hand Shower with 1 meter Long Easy Flex Tube in Chrome Finish & Wall Hook. |
| 197 | Analysed and ApprovedPvc trap including all fittings |
| 198 | D.S.R18.48 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 199 | Septic tank & Soakpit |
| 200 | 5.1.1Earth work in excavation in foundation trenches in ordinary soil (vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing ro |
| 201 | 5.1.2Extra for earthwork in hard soil as per specification and direction of E/I. ( Vide classificationofsoil iten _B) |
| 202 | 5.1.10Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as pe |
| 203 | 5.3.1.2Providing and laying in position cement cocrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level1:2:4 (1 cement : 2 coarse sand (zone -III ) : 4 graded stone aggregate 20 mm nominal Size) |
| 204 | 5.6.1Providing designation 75 A one brick flat soling joints files with local sand including cost of watering taxes royalty all complete as per building specefication and direction of E/I |
| 205 | 5.2.2Providing designation 75A brick work inC.M (1:4) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curri |
| 206 | 5.2.23Providing designation 125 mm thick reinforced designation 75A brick work in CM (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 25 including the cost of screening, carriage of materials, scaffolding , raking out |
| 207 | 5.3.11R.C.C. Work in beams, suspended floors, roofs having slope upto 15° landing, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size) |
| 208 | 5.3.17.20Centering and Shuttering including strutting, propping etc. And removal of form for Suspended floors, roofs, landings, balconies and acces platorm with water proof ply 12mm thick |
| 209 | 5.3.11R.C.C. Work in beams, suspended floors, roofs having slope upto 15° landing, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size) |
| 210 | 5.3.17.21Centering and Shuttering including strutting, propping etc. And removal of form for Lintel, beams. Plinth beams, girders, bressumers and cantilevers with water proof ply 12mm thick |
| 211 | 5.7.2Providing 12mm thickcement plaster (1:4) with clean coarse sand of F.M 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I |
| 212 | 5.7.11Providing 1.5mm cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/I. |
| 213 | Basic Rate of SOR 2021M-198 (page no 44)Providing and laying brick bats in soakpit with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I. |
| 214 | 5.5.4Providing Tor steel reinforcement of 8 mm dia rods as perapproved design and drawing excluding carriage of bars to work site cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complet |
| 215 | 5.5.5Providing Tor steel reinforcement of 10mm , 12mm & 16mm dia rods as perapproved design and drawing excluding carriage of bars to work site cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in positio |
| 216 | (a) 10 mmTMT bar FE 500 ( Only Valid for SAIL & TATA Steel ) |
| 217 | DSR 12.41Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes.12.41.2 110 mm diameter |
| 218 | Basic Rate of DW & SD SL NO 31(b)M 947Supplying, fitting and fixing C.I. cover with frame for mane hole and inspection chamber with all leads and lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of E/I. (a) Size 600 x 450 mm (Wt. 25 Kg). |
| 219 | Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I. |
| 220 | Bricks(1k+7p)= 8 km |
| 221 | Coarse sand (1K+50P = 51 Km) |
| 222 | Stone Chips (1K+34P = 35 km) |
| 223 | Cement(5 km) |
| 224 | Steel (5 km) |
| 225 | Deep bore Well |
| 226 | WD & SD Basic rate item no. 119 M 1035Suppling all materisls labour and tools and cost of drilling 200mm x 165mm bore well in all kinds of soil and rock in rural area for installation of pump set with hydrolic DTH rig machine, all complete including suplying all materials tools, drilling rig, Air compressor and equipments, as well as fuel, lubricants and cost of transprtation of Rig machine and other vehicles up to the site. |
| 227 | From 0.0M to 50.0 M belew G.L |
| 228 | From 51.0 M to200.00 M belew G.L |
| 229 | DW& SD Basic rate item no. 120 M 1036supplying all tools, tackles & lowering of 200 mm dia MS ERW casing pipe of 6mm wall thickness including welding charges, cost of pipe itc including all taxes, VAT, Excise duty, freight charges with inspection charges etc as applicable, etc all complete job. |
| 230 | DW& SD Basic rate item no. 126 M 1042Cleaning Flushing and devloping of drilled hole for testing the discharge of water development of bore well by continueous flow of water bu using heavy compresser upto satisfaction of E/I. To get uniterrupted flow of water free from sand and soil etc. |
| 231 | DW& SD Basic rate item no. 120 M 1036Supplying and fitting M.S cap over 200mm dia casing pipe as per direction of E/I . |
| 232 | WD & SD Basic rate item no. 139M 1055Supplying 100 mm dia submersible pump sets confirming to IS 8034 and motor confirming to IS 9283. Pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/ noryl impeller. Motor suitable for working on 415V + 10%, 3PH, 50 Hz, A.C. supply with cable guard, thrust carbon/ fiber bearing to withstand entire hydraulic thrust, water proof winding shall be provided. The pump set shall be suitable for direct coupling. Pump shall have suitable outlet as per manufacturers design. Anti thrust stream lined non return valve shall be provided with pump. 3 meter submersible copper conductor cable in single/ double run shall be provided with each pump. |
| 233 | Submersible Pump 150 mm dia ( with Bronze impeller) up to 8 stages2.0 HP |
| 234 | WD & SD Basic rate item no. 149M 1065Supplying Fully Automatic Starter to operate induction motor working on 415v, 3 phase ,50 hz with no volt coil , Over load element , ON-OFF push buttons with necessary materials and connected to supply etc complete starter with original sheet steel encloser as per IS: 3914.F.A.S.D. Starter |
| 235 | WD & SD Basic rate item no.146 M1062Supplying 3 core flat flexible submersible cable with, copper conductor, PVC insulated and PVC sheathed as per IS : 70983 Core 4mm thick |
| 236 | Rate Analiysed and Approved2no heavy duty clamp 40mm dia duitable for pipe with all complet job. |
| 237 | WD & SD Basic rate item no. 14(K) (v)Supplying & lowering 40mm da column G. I. pipe with all complete job. |
| 238 | Approach road (30 mtr) |
| 239 | 3.1Excavation in Soil by Manual means. (Excavation for foadway in soil using manual means including loading in truck for carrying of cut earth to embankment site with all lifts and lead upto 1000 metres.)(ii) Including Royalty @ Rs. 27.48 per cumthe cost of watering, rolling & compaction(i) Rolling with vibratory roller |
| 240 | 5.1.10Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as pe |
| 241 | 5.6.2Providing designation 75 A one brick edge soling joints files with local sand including cost of watering taxes royalty all complete as per building specefication and direction of E/I |
| 242 | 5.3.1.2Providing and laying in position cement cocrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level1:2:4 (1 cement : 2 coarse sand (zone -III ) : 4 graded stone aggregate 20 mm nominal Size) |
| 243 | Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I. |
| 244 | Bricks(1k+7p)= 8 km |
| 245 | Local Sand (3 km) |
| 246 | Coarse sand (1K+50P = 51 Km) |
| 247 | Stone Chips (1K+34P = 35 km) |
| 248 | Cement(5 km) |
| 249 | Electrical Installation Work |
| 250 | Note:- OF MAKE (1)PVC insuleted copper conductor wire of make:-Havell\"s/Mescab/Anchor (2)PVC conduit of thiknss 1.5mm/2mm for wiring:-Polycab/ANCHOR/AKG (3) GI modular box of make -: Anchor/ Havells/Legrand/ (4)Switches/soket outlet for modular type:- Anchor (roma)/Havells(cabtree)Legrand (5)MCCB,MCB,SFU,CHANGEOVER,RCCB,MCB-DB:-Havell\"s/L&T/C&S (6)XLPE/PVC aramoured cable:-Havell\"s/Mescab/V-guard (7) LED ITTING FIXTURE -: Havells/Bajaj/Crompton (Model/as per E/I ) (8) CEALING / WALL / EXHAUST FAN -: Havells / Bajaj / Usha / Crompton (Model/as per E/I ) (9)OCTAGONAL POLE-: Bajaj/Philips/Surya (10) CHEMICAL EARTHING OF MAKE - TRUEPOWER EARTHING (11) CENTRALISED AIR CONDITIONING OF MAKE - VOLTAS/MITSHUBISHI/ TOSHIBA/DAIKIN (12)ALL ELECTRICAL WIRING WORK SHOULD BE CONCEALED |
| 251 | 1.3Point wiring in PVC conduit, with modular type switch:-Wiring for light point/fan point/exhaust fan point/call bell point with 1.5. sq.mm FR PVC Insuleted copper conductor single core cable in recessed PVC conduit, with modular type switch, pheonlic lamineted sheet,suitable size G.I.box etc. |
| 252 | 1.3.2Group B |
| 253 | 1.4Twin control point wiring PVC conduit with modular type switch:-wiring for Twin control point with 1.5 sq mm FR PVCInsuleted copper conductor single core cable in recessed PVC conduit, 2 way modular, switch, pheonlic lamineted sheet,suitable size G.I.box etc.as required.( for bed switch and staircase) |
| 254 | 1.5Power plug wiring in PVC conduit(2x4 sq mm) :- Wiring for light/Power plug with 2x4 sq mm FR PVC insuleted copper conductor single core cable in recess PVC conduit along with 1 Nos. 4 sq mm FR PVC insuleted copper conductor single core cable for loop earthing as required. |
| 255 | 1.7Circuit/submain wiring in PVC conduit:-Wiring for circuit/submain wiring along with earth wire with the following size PVC insuleted copper conductor single core cable in recessed PVC conduit as required |
| 256 | 1.7.12x1.5 sq mm+1x1.5 sq mm earth wire |
| 257 | 1.7.22x2.5 sq mm+1x2.5 sq mm earth wire |
| 258 | 1.7.22x2.5 sq mm+1x2.5 sq mm earth wire(for building lighting) |
| 259 | 1.7.104x6 sq mm+2x6 sq mm earth wire |
| 260 | 1.7.114x10 sq mm+2x10 sq mm earth wire |
| 261 | 1.16Teliphone wiring existing conduit:- Supplying and drawing following pair 0.5 sq mmFR PVC insuleted copper conductor, unaramed teliphone cable in existing recessed PVC conduit as required |
| 262 | 1.16.33 Pair |
| 263 | 1.17TV cable in existing conduit :- Supplying and drawing co-axial TV cable RG-6 grade copper conductor,PE insulated,withPVC sheath in the existing recessed PVC conduit as required. |
| 264 | 1.21S/F PVC conduit :-supplying and fixing of following sizes PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case recessed conduit as required . |
| 265 | 1.21.120mm |
| 266 | 1.24S/F modular type switch /socket :- Supplying and fixing following modular type switch box/cover including connections but excluding modular plate etc as required |
| 267 | 1.24.15/6 amps, one way switch |
| 268 | 1.24.315/16 amps, one way switch |
| 269 | 1.24.4 5/6amps, 3 pin socket outlet |
| 270 | 1.24.515/16 amp 6 pin socket outlet |
| 271 | 1.24.6Teliphone socket with shutter outlet |
| 272 | 1.24.7TV socket socket outlet |
| 273 | 1.25S/F Modular type electronic fan regulator:-Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connectionons but excluding modular plate etc, as required. |
| 274 | 1.26S/F Modular type blanking plate:-Supplying and fixing modular blanking plate on the existing modular plate switch boxexcluding modular plate etc, as required. |
| 275 | 1.27S/F Modular boxes, base & covre plate:-following size/ modular G.I box along with modular base & cover plate for modular switches in recess etc, as required. |
| 276 | 1.27.11 or 2 module(78mm x 78mm x 45mm) |
| 277 | 1.27.36 module(78mm x 205mm x 50mm) |
| 278 | 1.27.48/9 module(78mm x 230mm x 60mm) |
| 279 | 1.32S/F power plug point with modular type accessories:- Supplying and fixing suitable size G.I.box with modular plate and coverin front on recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular switchconection painting etc, as required. |
| 280 | 1.33S/F ceiling rose:-Supplying and fixing 2 pin 5 amp, ceiling rose on the existing junction box/wooden block including connection etc as required. |
| 281 | 1.34S/F Batten holder:-Supplying and fixing batten/angle holder including connection etc, as required. |
| 282 | 1.36S/F Dingdong Call bell :-Supplying and fixing dingdong call bell suitable for DC/AC single phase,230 volt, complete as required. |
| 283 | 1.44ITC ceiling/wall fan:-Instaliation, testing and commissioning of ceiling fan including wiring the down rod of standard length( uptwo 30 cm) with 1.5 sq mm.FR PVC insulated copper conductor, single core cable etc as required |
| 284 | 1.48ITC exhaust fan up to 450 mm, sweep:-Installation of exhaust fan up to 450 mm. sweep in the exiting opening, including making the hole to suit the size of above fan, making good the damage, connection testing commissioning etc as required. |
| 285 | 2.4S/F MCCB in cubical panel board:-Providing and fixing following rating and capacity four pole MCCB in existing panel bord,including drilling holes in cubical panelmaking connections etc as required. |
| 286 | 2.4.3125 amps, 16 KA fixed thermal seting |
| 287 | 2.5S/F Busbar chamber :-Providing and fixing following capecity busbar chamber with 4 strips of suitable size of copper, heavy duty, complite with all accessosries including connections, earthing the body , etc as required. |
| 288 | 2.5.2200 amps |
| 289 | 2.6S/F Sheet metal ON/OFF-Load chenge over:-Providing and fixing following capacity 2 pole/ 4 pole ON/OFF-Load chenge over switches with side handle opreation, in sheet inclosure in existing panel board including drilling holes in metal board, making connection, earthing the body etc as required |
| 290 | 2.6.6200 amps, 4 pole |
| 291 | 2.10S/F VERTICAL TYPE T.P.MCB DB:-Supplying and fixing following way three pole and nutral,sheet,MCB distribution board,415 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR) Note:- Vertical type MCB TPDB is normally used where three phase outlets are required. |
| 292 | 2.10.512 way (4+36),Double door,Vertical type |
| 293 | 2.9S/F T.P.MCB DB:-Supplying and fixing following way three pole and nutral,sheet,MCB distribution board,415 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR) |
| 294 | 2.9.44 way (4+12),Double door, Horizontal type |
| 295 | 2.11S/F \"B\" series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, \"B\" series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required. |
| 296 | 2.11.16/32 amps,single pole, \"B\" SERIES |
| 297 | 2.12S/F \"C\" series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, \"C\" series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required. |
| 298 | 2.12.16/32 amps,single pole, \"C\" SERIES |
| 299 | 2.12.640 amps ,DP |
| 300 | 2.16.940 amps,TPN |
| 301 | 2.12.1050/63 amps, TPN |
| 302 | 2.13S/F SP MCBblanking plate:-Supplying and fixing Single pole blanking plate in exiting MCB DB complete etc as required. |
| 303 | 2.19P/F M.V. danger notice plate:-Providing and fixing M.V danger notice plate of 200mm x150mm made of mild steel, at least 2mm thick, and vitreous enamelled white on both sides, and with inscription in single red coiour on front side as required. |
| 304 | 3.7S/L 8 SWG copper wire ground :-Supplying and laying 8 SWG copper wire 0.50 metre bellow ground level for conductor earth electrode, including soldring etc. as required. |
| 305 | 4.2P/F G.I. lightning conductor finial:-Providing and fixing of lighting cnductor finial, made of 25 mm dia 300mm long, copper tube having single prong at top, with 85mm dia 3mm thick G.I. base plate including holes etc. complete as required. |
| 306 | 4.4Reverting, sweating and soldering of copper/G.I. tape(with another coppr/G.I. tape, base of the finial or any other metallic object) as required. |
| 307 | 4.7P/F G.I. lightning conductor tape in horizontal run:-Providing and fixing GI tape 20mm x 3mmthick on parapet or surface of wall for lightning conductor complete as required(For horizontal run) |
| 308 | 4.8P/F G.I lightning conductor tape in vertical run:-Providing and fixing GI tape 20mm x 3mmthick on parapet or surface of wall for lightning conductor complete as required(for vertical run) |
| 309 | 5.1MV cable laying upto 35 sq.mm. in ground:-Laying of one number PVC insuleted and PVC sheathed/ XLPE power cable of 11 KV grade of size not exceeding 35 sq.mm. direct in ground including excavetion, sand coushioning, protective covering and refilling the trench etc as required. |
| 310 | 5.2MV cable laying upto 95 sq.mm. in ground:-Laying of one number PVC insuleted and PVC sheathed/ XLPE power cable of 11 KV grade of size exceeding 35 sq.mm.but not exceeding 95 sq.mm. direct in ground including excavetion, sand coushioning, protective covering and refilling the trench etc as required. |
| 311 | DSR 11.3Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required11.3.2 Above 6.5 metre and upto 8.0 metre |
| 312 | S/L PVC XLPE insuletd PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts,(conforms to IS:1554, part-1) |
| 313 | M-74016 sq.mm. 4 core |
| 314 | M-32850 sq.mm. 3.5 core |
| 315 | M-33095 sq.mm. 3.5 core |
| 316 | DSR 12.37Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required |
| 317 | DSR9.1Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 318 | DSR9.1.334 X 16 sq. mm (28mm) |
| 319 | DSR9.1.223½ X 50 sq. mm (35mm) |
| 320 | DSR9.1.243½ X 95 sq. mm (45mm) |
| 321 | FIXTURE AND CHEMICAL EARTHING |
| 322 | M-775Providing of 12\"\" (300 mm)exhaust fan of make bajaj/havells/usha/crompton |
| 323 | 9.4SITC of following size ceilling fan 3 blades confirming to IS :374:219 including wiring the down rods standard length ( up to 30 cm with 1.5 sqmm FRPVC insulated copper wire suitable for 230 volt 50Hz single phase supply etc complet as required of make Havells,Bajaj,Crompton,Polar9.4.11200 mm (48\") Ceilling fan |
| 324 | 9.4.11200 mm (48\") Ceilling fan |
| 325 | M-777Providing of 16\"\" (400 mm) Wall fan of make bajaj/havells/usha/crompton |
| 326 | M-856Supplying and fixing of LED 15/16 W of make bajaj/havells/crompton |
| 327 | 9.1 SITC of following rating LED street lighting luminarie with pressure dia cast housingh and toughned glass cover ,IP 66 Protection , LUMINOUSEFFICARY >_110 LM/W with lens in existing pole /pipe for supply voltage 100-270V AC ,50 Hz, luminarie shall be confirm to IS 10322 part -5 /section -3 and shall be complete with all neccssary accessosries as required. |
| 328 | 9.1.7SITC of LED street light (90/100 watt) of make bajaj/havells/crompton |
| 329 | 9.2S.I.T.C of following rating LED FLOOD lighting with pressure dia cast housing and toughened glass cover (IP 66 protection)in existing pole/pipe /platform/periferial wallfor supply voltage 100-270v AC,50Hz Luminire shall be confirmto IS-10322 part-5/ section-3 and shall be complete with all neccssary accessories as required.of make bajaj/havells/crompton |
| 330 | 9.2.5120 W LED FLOOD LIGHT of make bajaj/havells/crompton/C&S |
| 331 | M-869Providing of Bulkhead fitting with 9/10 watt LED/ CFL of make bajaj/havells/crompton |
| 332 | 9.5S.I.T.C of following rating surface mounted LED tube light fitting suitable for 230 volt 50 Hz single phase supply etc complet as required of make Havells,Bajaj,Crompton, C & S |
| 333 | 9.5.110/12 W LED Batten of make bajaj/havells/crompton/C&S |
| 334 | 9.5.220/22 W LED Battenof make bajaj/havells/crompton/C&S |
| 335 | 9.3SITC of following rating recess/ surface mounted LED round /square shape down light luminire with pressure dia cast housing for single phase supply voltage, Luminarie shall be confirmto IS:10322 part - 5/section -2 or IEC : 62722 with all neccessary accessories as required. |
| 336 | 9.3.315/16 W LED Round Down Lightof make bajaj/havells/crompton/C&S |
| 337 | 9.3.112\"x2\" LED Panel Light of make bajaj/havells/crompton/C&S |
| 338 | 9.3.136 W COB based round LED light with multiple beam angle (36 Degree)of make bajaj/havells/crompton/C&S/Jaguar |
| 339 | 9.6S.I.T.C of following rating LED Post top lamp made in dia cast aluminium housing with decoretive clear / opel acrylic diffuser on existing pipe including connection with 1.5 sq mm copper conductor etc all complete as required. Of make bajaj/philips/polycab/jaguar |
| 340 | 9.6.210/15 W LED Post top Lamp opel |
| 341 | 3.6Earthing with copper earth plate 600x600x3mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc (with charcoal or coke and salt) as required….. |
| 342 | M-742Supplying and fixing of 7 Mtr height octagomal Hot-Dip Galvanized pole (BOP-7030) with top dia 70 mm,bottom dia 130mm & made of 3 mm thick sheet ,base plate diamentions 200 MM X 200 MM X 12 MM (LxBxT) including suitable size of foundetion bolt and 1\"6\"\" long 50mmX50mm MS angle along with welded horizontally on top of octagonal pole all complete on exiting concreat platformas required OF MAKE BAJAJ/SURYA/PHILIPS |
| 343 | M-758Supplying and fixing of 1.5 mtr single arm suitable for 70 mm top of existing Octagonal pole OF MAKE BAJAJ/SURYA/PHILIPS |
| 344 | M 874Supplying and fixing of cable junction box of make sintex /Hensel |
| 345 | 1.16Teliphone wiring existing conduit:- Supplying and drawing following pair 0.5 sq mmFR PVC insuleted copper conductor, unaramed teliphone cable in existing recessed PVC conduit as required (FOR WATER PUMP CONTROLAR WIRING) |
| 346 | 1.16.34 Pair |
| 347 | DSR 1.53.1Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required.(Make- Legrand, Schneider- Digilink. |
| 348 | 9.8S.I.T.C of following rating approved make LED Bollard fitting with cylindrical shape of height 600 to 850 mm power input -8/9 watt with die cast aluminium |
| 349 | M-917 1.5Tr.5 Starsplit A.C (InverterType)I91391-part-I |
| 350 | M-9182.0Tr.5 StarSplitA.C (lnverterType)I91391-part-I |
| 351 | M-1618CopperTube of size 1/2\" for split ac unitT/7,s/2/3 tr capacity mtr includins nitride rubber insulation |
| 352 | M-1619CopperTube of size 3/8\" for split ac unitT/7,s/2/3 tr capacity mtr includins nitride rubber insulation |
| 353 | M-16214 KVA wallmountedautomadc voltage stablizerfrom range140V to 280V |
| 354 | M-16225 KVA wallmountedautomadc voltage stablizerfrom range140V to 280V |
| 355 | M-1623DrainPipe for AC |
| 356 | M-1624Outdoor stand for 1.5Tr SplitAC |
| 357 | M-1625Outdoor stand for 2.0Tr SplitAC |
| 358 | Rain Water Harvesting |
| 359 | 5.1.1Earth work in excavation in foundation trenches in ordinary soil (vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I. |
| 360 | 5.1.2Extra for earthwork in hard soil as per specification and direction of E/I. ( Vide classificationofsoil iten _B) |
| 361 | 5.1.10Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 362 | 5.6.1Providing designation 75 A one brick flat soling joints files with local sand including cost of watering taxes royalty all complete as per building specefication and direction of E/I |
| 363 | 5.3.1Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :5.3.1.31:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40 mm nominal size) |
| 364 | 5.2.2 Providing designation 75A brick work inC.M (1: 4) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I. |
| 365 | SOR Page 36 of Itm no M-009 & 10% CPStone Metal at quarry site .. Traxes and royalty all complete as per building specification and direction of E/I.90 mm Gravel filling |
| 366 | 0.90 M stone Boulder filling |
| 367 | 5.3.20Providing, hoisting and fixing above plinth level up to floor five level precast Reinforced cement concrete in shelves, including setting in cement mortar 1:3 (1cement : 3 coarse sand), cost of required centering, shuttering and finishing with neat cement punning on exposed surfaces but , excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size). |
| 368 | 5.7.1Providing 12mm thick cement plaster (1:3) with clean coarse sand ofF.M. 1.5 approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as perbuilding specification and direction of E/I. |
| 369 | 5.7.6 Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scafolding taxes and royalty all complete as per buildings specification and direction of E/I. |
| 370 | 5.5.4Providing Tor steel reinforcement of 8 mm dia rods as perapproved design and drawing excluding carriage of bars to work site cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per builing specification and direction of E/I. (TMT Fe 500 (Only valid for SAIL & TATA Steel ) |
| 371 | DSR 12.41.2Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter |
| 372 | DSR 12.42 Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS :5382, leaving 10 mm gap for thermal expansion. |
| 373 | ( 12.42.5.2) 110 mm bend |
| 374 | ( 12.42.6.2) Shoe 110 mm |
| 375 | DSR 12.43.2Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand)and making good the wall etc. complete(110 mm ) |
| 376 | Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I. |
| 377 | Bricks(1k+7p)= 8 km |
| 378 | Local Sand (3 km) |
| 379 | Coarse sand (1K+50P = 51 Km) |
| 380 | Stone Chips (1K+34P = 35 km) |
| 381 | Cement(5 km) |
| 382 | Steel (5 km) |
| 383 | SOR PHED (page no 56 M 1038) DT: Basic rate for 125/115 mm dia drilled Tube Well for drilling in all kinda of Soil and rock for installation o hand pump with DI rings all complete including supplyin all materials, labours , tools drilling rigs air compressor and equipments s well as fuel li\ubricant for making125/115 mm dia boring etc and cost of transporting rigmachine and other vechile up to site of work including contrctor profit & OH chares as per specification and directtion of Engineer Incharge(basic rate) |
| 384 | Drilling upto 30 M depth below G.L in Rulararea |
| 385 | Drillingbeyond 31 mtr upto 55 mtr below GL in Ruralarea |
| 386 | SOR PHED (page no 63 M 1041)Supplying all materials labours equipments for lowering 125 mm dia blue UPVC Casing Pipe as casing for protecting the sides from falling during the process of drilling all complete including carrriage of materials to work site (Basic Rate) |
| 387 | S/M/L forF/f wire mesh pipe |
| 388 | Land Development |
| 389 | DSR/16.68Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. |
| 390 | 5.1.10Providing coarse clean local sand in filling in foundation trenches or in plinth including ramming and watering in layer not exceeding 150mm thick with all leads and 1.5M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer Incharge (Mode of measurement compacted volume) |
| 391 | 5.3.2 Providing PCC M-15 with nominal mix of (1:2:4)in foundation with apporoved quality of stone chips 20mm to 6 mm size grades and clean course of F.M 2.5 to 3 including screening, shuttering, mixing cement concrete in mixture, cement concrete in mixture and placing in position , vibration, striking, curing taxes and royalty all complete as per building specification & direction of E/I. |
| 392 | 5.2.3Providing designation 75A brick work inC.M (1: 6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I. |
| 393 | 5.7.3Providing 12mm thick cement plaster (1:6)with clean coarse sand of F.M. 1.5 and including cost of screening, curingwith all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I |
| 394 | 13.46.1/ DSRFinishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primerapplied @ 2.20 kg/ 10 sqm) |
| 395 | 11.56/ DSR Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with whitecement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.11.56.1 Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 396 | 8.3/DSR Providing edge moulding to 18 mm thick marble stone counters, Vanitiesetc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.8.3.2 Granite work |
| 397 | 5.1.8Filling in foundation trenches and plinth layers not exceeding 150 mm thick well watered rammed fully compacted and fine dressed withearth obtained after cutting with in a lead of 50M and lift of 1.5M all complete as per building specification and directionof E/I ( Mode of measurement compacted volume)For Land Scapping Work |
| 398 | Cairage Of Meterial |
| 399 | Bricks(1k+7p)= 8 km |
| 400 | Coarse sand (1K+50P = 51 Km) |
| 401 | Stone Chips (1K+34P = 35 km) |
| 402 | Cement(5 km) |
| 403 | Earth( 3 KM) |
| 404 | Boundary Wall (150 mtr) |
| 405 | 5.1.1 EARTH WORK INEXCAVATION IN FOUNDATION Trenches in ordinary soil (vide classification of soil item -A) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I. |
| 406 | 5.1.2Extra for earthwork in hard soil as per specification and direction of E/I. ( Vide classificationofsoil iten _B) |
| 407 | 5.1.7EARTHFILLING IN FOUNDATION TRENCHES AND PLINTH in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume) |
| 408 | 5.1.10Providing coarse clean local SAND IN FILLING in foundation trenches or in plinth including ramming and watering in layer not exceeding 150 mm thick with all leads and 1.5 M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer Incharge (Mode of measurement compacted volume) |
| 409 | 5.6.1 Providing designation 75-A, BRICK FLAT SOLING joints filled with local sand including cost of watering,taxes and royalty all complete as per building specification and direction of Engineer Incharge |
| 410 | 5.3.1.4Providing P.C.C. M-10 with nominal mix of (1:3:6) inFoundation with approved quality of stone metal grade III (53 to 22.4 mm size) and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixture, placing in position, vibration, striking, curing, taxes and royalty all complete as per building specification & direction of E/I. |
| 411 | 5.3.9 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level.5.3.9.1 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 412 | 5.3.17.1Centering and Shuttering including strutting, propping etc. And removal of form for Foundation, footing, bases of column, etc. For mass concrete |
| 413 | 5.3.10R.C.C. Work in wall (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, column, pillars, piers, abutments, posts and stru etc. Above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size) |
| 414 | 5.3.17.6Centering and Shuttering including strutting, propping etc. And removal of form for Column, Pillars, Piers, Abutments, posts and Struts |
| 415 | 5.3.11 Providing R.C.C.M 20 (1: 1.5: 3) inBand at Plinth level with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and directionof E/I |
| 416 | 5.3.11Providing R.C.C.M 200 (1: 1.5: 3) inBand at Plinth level with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and directionof E/I |
| 417 | 5.3.17.21Centering and Shuttering including strutting, propping etc. And removal of form for Lintel, beams. Plinth beams, girders, bressumers and cantilevers with water proof ply 12mm thick |
| 418 | 5.2.11 Providing designation 75 A BRICK WORK in CM. (1:6) in SUPERSTRUCTURE with approved quality of clean coarse & of F.M. 2.5 including providing 10mm thick mortar joints cost of screening,racking out joints to 15 mm depth,curing, taxes and royalty all complete as per building specification and direction of Engineer Incharge |
| 419 | 5.7.3Providing 12 mm Thk. cement plaster(1:6) on inside walls with clean course sand of FM-1.5including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all completeas per building specification and direction of E/I |
| 420 | Providingtor steel reinforcement TMT FE 500 of following dia. rods as per approved design and drawing includingcarriage of bars to work site, cutting, bendingandbinding with annealedwirewithcostofwire, removal ofrustplacingtherods in position all complete as perbuilding specification and direction and direction of E/I.(Only valid for TATA TISCON / SAIL). |
| 421 | 5.5.4Providing Tor steel reinforcement of 8 mm dia rods as perapproved design and drawing excluding carriage of bars to work site cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complet |
| 422 | 5.5.5a10mm dia- TMT Fe 500 (Onaly valid for SAIL, TATA Stee, JSPL, Electro Steel Ltd and Vizal Steel) |
| 423 | 5.5.5b12mm dia- 20mm dia TMT Fe 500 (Onaly valid for SAIL, TATA Stee, JSPL, Electro Steel Ltd and Vizal Steel) |
| 424 | 5.5.5(c) 16mm (TMT coil Fe 500) (only valid forTata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL)}) |
| 425 | 5.5.620/25mm TMT bar Fe 500 (only valid forTata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL)}) |
| 426 | Finishing walls with Acrylic Smooth exterior paint of required shade New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 427 | DSR16.53Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron \"Y\" shaped placed 2.4 m or 3.00 m apartand with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Springcore (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) |
| 428 | Approved basic rates of material item No. 29+ 10%C.P.Supplying ofM.S.ANGLE OF 50X50X6 for support of Concertina wire including all carriage, taxes, all complete. |
| 429 | 5.5.23Drilling 6mm dia holes in M.S. angle iron for fixing of staples etc. as per building specification and direction of E/l. |
| 430 | 5.5.28Labour for fabricating, erecting, hoisting and fixing in position structural steel work in R.S. joist, channel, Angle, Tee, flat, plate, latice member, built up compound section in column, girder, staircase or truss including cost of gusset plates, holding down bolts, anchor plates at all heights and depths, bolting, welding (machining wherever necessary) with applying a priming coat of red lead paint all complete as per approved drawing, building specification and direction of E/l. |
| 431 | 5.5.24 Labour for cutting of M.S. angle iron post to required length, one end splitted as fishtailed in length of 150 mm complete as per building specification and direction of E/I. |
| 432 | 5.8.45Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly, scaffolding and taxes all complete as per building specification and direciton of E/l. |
| 433 | CARRAIGE OF MATERIALS |
| 434 | Bricks(1k+7p)= 8 km |
| 435 | Local Sand (3 km) |
| 436 | Coarse sand (1K+50P = 51 Km) |
| 437 | Stone Chips (1K+34P = 35 km) |
| 438 | Cement(5 km) |
| 439 | Steel (5 km) |
| 440 | Add 18% GST |
| 441 | Add 1% Lebour Cess |