Tender For Rewiring / Renovation Of Existing Burn Out Electrical Accessories At Govt. Sarvodaya Kanya Vidyalaya, Burari, Delhi.
Tender Value
13.32 Lakhs
Estimated cost
Bid Submission
26 Sep 2023
0 days left
EMD
26641
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
burari → Delhi
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Rewiring / Renovation Of Existing Burn Out Electrical Accessories At Govt. Sarvodaya Kanya Vidyalaya, Burari, Delhi.
BOQ
| Sl. No. | Item Description |
| 1 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. i) Group C |
| 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. i)Group C |
| 3 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core in surface /recessed steel conduit as required i) 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 4 | Supplying and drawing following sizes of FR PVC insulated copper conductor , single core cable in the existing surface / recessed steel/ PVC conduit as required. i) 3 x 1.5 sq. mm |
| 5 | 6 x 1.5 sq. mm |
| 6 | 3 x 4 sq. mm |
| 7 | 6 x 4 sq. mm |
| 8 | 3 x 6 sq. mm |
| 9 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. i) 5/6 amps switch |
| 10 | 15/16 A switch |
| 11 | 3 pin 5/6 A socket outlet |
| 12 | 6 pin 15/16 A socket outlet |
| 13 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 14 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. i) 20 mm |
| 15 | 25mm |
| 16 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. i) 20 mm |
| 17 | 25mm |
| 18 | Replacement ofsuitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection, painting etc as required. |
| 19 | Replacement ofsuitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 amps & 5/6 amp modular socket outlet and 15/16 amps modular switch, connection, painting etc as required. |
| 20 | Replacement offollowing size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. i) 3 Module (100 mmX75 mm) |
| 21 | 6 Module (200mmX75mm) |
| 22 | 8 Module (125mmX125mm) |
| 23 | 12 Module (200 mmX150 mm) |
| 24 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) i)i) 4 way (4 + 12), Double door |
| 25 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) i) 8 way, Double door |
| 26 | Supplying and fixing Cable End Box (Loose wire box)(IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and commissioning etc. as required. i) For 8 way, Double door SPN MCBDB |
| 27 | Supplying and fixing 5 amps to 32 amps rating 240 volts \"C\" curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections , testing and commissioning etc. as required. i) Single pole |
| 28 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. i) 63 amps |
| 29 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 30 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 31 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 32 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 33 | S.I.T.C of surface/wall mounted(Integrated type) 18to20 W LED batten fitting 1200 mm long (N/S) made out ofCRCA sheet duly power coated/Aluminum extruted body confirming to IP - 20, suitable for operation on 150 V to 270 V, 50 Hz AC Supply, having power factor = 0.90, CRI = 80,Luminaries efficacy = 100 lumen/watt , Driver efficiency > 85%, 2.5 kv surge protection, L-70 Life, 50,000 burning hours. complete i/c dismantling of existing fitting, connection, etc. complete as reqd. |
| 34 | Supplying and fixing of 1200 mm sweep AC ceiling fan with Three star rating and above complete with all accessories but without regulator i/c wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm FRLS PVC insulated copper conductor cable i/c dismantling the existing non-working fan etc complete as required. |
| 35 | SITC of 450mm size heavy duty exhaust fan, 1 phase, 230v 900 RPM in the existing/making opening, i/c supplying and fixing of suitable gravity louvers from outside including making the connection, testing etc. as required. |
| 36 | Supplying & Laying of one number PVC insulated and PVC sheathed / XLPE power aluminum conductor armoured cable of 1.1 kV grade of following size on existing DWC Pipe etc as required. 1) 4 x 25 sq.mm |
| 37 | S.I.T.C of 150 Watt LED Flood Light Fittings confirming to IP - 66, made out of Aluminum body for installation on pole/wall surface, suitable for operation on 150 V to 270 V, 50 Hz AC Supply, having power factor > 0.95, CRI > 80, Luminaries efficacy = 100 lumen/watt, (5000 to 6500K) Driver efficiency > 85%, 10 ka surge protection, L-70 Life 50,000 burning hours. complete i/c dismantling of existing fitting, connection, etc. complete as reqd. |
| 38 | Credit of old dismantle material i) Assorted wire/Cable |
| 39 | Old Switches/ Sockets |
| 40 | Old MCB/DB |
| 41 | Old LED Fittings |
| 42 | Old Ceiling Fan/Exhaust Fan |
AI Tender Summary
Tender Timeline
Sep 19, 2023
11:30 IST
Tender Published
Tender notice published.
CompletedSep 26, 2023
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedSep 26, 2023
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender