Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 29-09-2023 | Technical Bid 2 | Technical Bid | 09-10-2023 |
| 2 | 27-09-2023 | Technical Bid | Technical Bid | 09-10-2023 |
| Sl. No. | Item Description |
| 1 | Rates for Development of Satpuli Water Supply Scheme in Distt Pauri Garhwal, Uttarakhand |
| 2 | Earth work for Pipe line & its ancillary work |
| 3 | Excavation in ordinary soil (loam, clay, sand) for pipe line trenches including lift up to 1.5M and lead up to 30M with back filling, watering, ramming of excavated earth in the trenches. |
| 4 | Excavation in soil mixed with single bouldres etc. requireing the use of specials T&P, if any, for pipe line trenches including lift up to 1.5M and lead up to 30M with back filling, watering, ramming of excavated earth in the trenches. |
| 5 | Bedding |
| 6 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 7 | Providing & laying Granular bedding with graded hard crusher broken stone of 100% passing through 20mm sheive, 20 to 50 % passing through 10mm sheive and 100 % retain on 6.3mm sheive, laying in layers of thickness 10/15cm including ramming, consolidation etc complete for all type of pipes of following sizes as per drawing and or as directed by Engineer. |
| 8 | Pipe line worka. Gravity Main |
| 9 | Providing of all materials, Carting from site store to site of work,lowaring into trenches with true to alignment, laying of MSERW Pipe grade Yst 210, confirming to IS: 1978-1982, jointionh by electric welding process with proper grade of electrodes suitable for jointing of water supply pipe line (Ador, L&T or equivalant electrodes) by cuting of pipe and making required bends by welding, comletion of work with testing of pipe line etc complete.100 mm dia 4.8 mm thickness |
| 10 | 150 mm dia 4.8mm thickness |
| 11 | 200 mm dia 4.8 mm thickness |
| 12 | Providing of all materials, Carting from site store to site of work,lowaring into trenches with true to alignment, laying of GI Pipe gradeconfirming to IS: 1239 ( PART-I )including supply of all jointing material like special white lead, hemp and oil etc in trenches with its cuttiong, threading and testing of pipe line etc complete.125mm |
| 13 | b. Rising Main/Pumping main |
| 14 | Providing of all materials, Carting from site store to site of work,lowaring into trenches with true to alignment, laying of GI Pipe gradeconfirming to IS: 1239 ( PART-I )including supply of all jointing material like special white lead, hemp and oil etc in trenches with its cuttiong, threading and testing of pipe line etc complete.125 mm |
| 15 | c. Distribution System |
| 16 | Providing of all materials, Carting from site store to site of work,lowaring into trenches with true to alignment, laying of MSERW Pipe grade Yst 210, confirming to IS: 1978-1982, jointionh by electric welding process with proper grade of electrodes suitable for jointing of water supply pipe line (Ador, L&T or equivalant electrodes) by cuting of pipe and making required bends by welding, comletion of work with testing of pipe line etc complete.200 mm dia 4.8 mm thick |
| 17 | Providing of all materials, Carting from site store to site of work,lowaring into trenches with true to alignment, laying of GI Pipe gradeconfirming to IS: 1239 ( PART-I )including supply of all jointing material like special white lead, hemp and oil etc in trenches with its cuttiong, threading and testing of pipe line etc complete.65 mm dia |
| 18 | 80 mm dia |
| 19 | 100 mm dia |
| 20 | 125 mm |
| 21 | 150 mm |
| 22 | Supply ofDI Sluice of approved make & design standard of following dia complete including jointing & jointing material ) including all material, labour, testing and commissioning along with pipe line as per Technical Specification & as per direction of Engineer.Manually operated class PN 1.6.65 mm dia |
| 23 | 80 mm dia |
| 24 | 100 mm dia |
| 25 | 125 mm dia |
| 26 | 150 mm dia |
| 27 | 200 mm dia |
| 28 | Installation ofDI Sluice of approved make & design standard of following dia 65 mm dia |
| 29 | 80 mm dia |
| 30 | 100 mm dia |
| 31 | 125 mm dia |
| 32 | 150 mm dia |
| 33 | 200 mm dia |
| 34 | Providing, lowering, laying, aligning, fixing in position in pipe line, Resilient Seated D/F DI Scour valves of approved make & design standard of following dia complete including jointing & jointing material ) including all material, labour, testing and commissioning along with pipe line as per Technical Specification & as per direction of Engineer.100 mm |
| 35 | Providing, lowering, laying, aligning, fixing in position and jointing in pipe line DI Kinetic Double Air Valves (PN 1.6) of following dia (including jointing and jointing material), including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer.50 mm |
| 36 | 80 mm |
| 37 | Providing, Supplying and fixing of D/F DI Pressure Reducing Valve in pipe line including jointing etc. complete as per standard/ technical specification and direction of Engineer-in-Charge. As per design.65 mm dia |
| 38 | 80 mm dia |
| 39 | 100 mm dia |
| 40 | 125mm |
| 41 | 150mm |
| 42 | 200mm |
| 43 | Supplying and fixing of following sizes of valves including carting the same upto site of work and fixing the same in water supply lines including cost of valves, specials, labour and T&P complete in all respect but excluding the cost of earth work and construction of chamber.80 mm diameter Fire Hydrant Valve Confirming to IS: 5290 (Flanged) |
| 44 | Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (suitable for sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning as per Technical Specifications and as per direction of Engineer.65 mm dia PN-1.1 |
| 45 | 80 mm dia PN-1.0 |
| 46 | 100 mm dia PN-1.0 |
| 47 | 125 mm dia PN-1.1 |
| 48 | 150 mm dia PN-1.0 |
| 49 | 200 mm dia PN-1.0 |
| 50 | Construction of brick masonry Sluice valve chamber for different type of valves with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 coarse sand),both side 12 mm thick cement plaster in CM 1:4(1 cement : 4 coarse sand),top cover slab 150mm thick RCC M25 gradeincluding earthwork excavation, 100mm thick leveling course of PCC M15 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of steel reinforcement not less than 80kg per cum CC, form work, proper curing complete in all respect as per standard specifications and drawings and as directed by Engineer.with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid (As per Unit Estimate)For 100-150 mm dia pipe |
| 51 | For 200-250 mm dia pipe |
| 52 | Construction of brick masonry Air valve chamber for different type of valves with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 coarse sand),both side 12 mm thick cement plaster in CM 1:4(1 cement : 4 coarse sand), top cover slab 150mm thick RCC M25 gradeincluding earthwork excavation, 100mm thick leveling course of PCC M15 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of steel reinforcement not less than 80kg per cum CC, form work, proper curing complete in all respect as per standard specifications and drawings and as directed by Engineer. (As per Unit Estimate)For 100-150 mm dia pipe |
| 53 | Construction of brick masonry Scour valve chamber for different type of valves with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 coarse sand),both side 12 mm thick cement plaster in CM 1:4(1 cement : 4 coarse sand), top cover slab 150mm thick RCC M25 gradeincluding earthwork excavation, 100mm thick leveling course of PCC M15 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of steel reinforcement not less than 80kg per cum CC, form work, proper curing complete in all respect as per standard specifications and drawings and as directed by Engineer.(As per Unit Estimate)For 100-150 mm dia pipe |
| 54 | Providing, installation, testing and commissioning of Electromagnetic Flow Meter etc. including all materials (excluding CI/DI fittings) and making connection with existing pipeline required for Electromagnetic Flow Meter including cutting the existing pipe line etc. complete in all respect as per technical specification and as per direction of Engineer.80 mm |
| 55 | 100 mm |
| 56 | 150 mm |
| 57 | 200 mm |
| 58 | Construction of RCC Electro-Magnetic Flow meter chamber including earthwork excavation, 100mm PCC M15 (1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) as leveling course, RCC M25 grade for base slab, side wall & cover slabincluding cost of steel reinforcement not less than 80kg per cum CC, form work, proper curing of concrete work complete in all respect as per standard specifications and drawings and as directed by Engineer. (As per Unit Estimate)Upto 250 mm dia pipe |
| 59 | Constructing masonry Chamber 60x60x75 cm, inside in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for fire hydrants,with C.I. surface box 350x350 mm top and 165 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : |
| 60 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level.1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) for Thrust block (As per Unit Estimate) |
| 61 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately). |
| 62 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo- mechanically Treated bars of grade Fe-500D or more. |
| 63 | Centering and shuttering including strutting, propping etc. and removal of form work for :Foundations, footings, bases for columns |
| 64 | Clear Water Reservoirs and Sump |
| 65 | Supply of all materials, labor, T&P etc and construction of R.C.C. CWR of following capacities ( in kiloliters ) with M.S. ladder outside the tank and alluminium ladder inside of the tank, M.S. M.H. cover with locking arrangement, lightning conductor as per electricity rules, water level indicator,supply and fixiing of outlet, inlet, over flow and wash out pipes with necessary sluice valves, pipe pieces (including cost of materials) flooring 0.60 M wide apron, painting on tank body vertical pipes, ladder, M.S. M.H. cover, ventilator column etc. complete with approved water proofing (apex) / enamal paint, testing, filling water for testing purpose etc. including supply of vertical pipes and specials, assuming bearing capacity as 8MT/M2. as per designDMA-05 |
| 66 | Kukraiti Band(MLA Mohalla) |
| 67 | Kukraiti Band |
| 68 | Malli Satpulla |
| 69 | Dhondiya Tok |
| 70 | Garbadyaq Tok |
| 71 | Sump 50 KL at RBF |
| 72 | Dismantling of Exsiting tank including disposal of dismantled material as per direction of Engineer-in charge . (As per Unit Estimate) |
| 73 | Provision of Bridge-Path for pipe crossing-5 meter (As per Unit Estimate) |
| 74 | Protection work as per site condition (As per Unit Estimate) |
| 75 | Repair work of existing CWR (150 KL) (As per Unit Estimate) |
| 76 | Repair work of existing CWR (60 KL) |
| 77 | Repair work of existing CWR (45 KL) |
| 78 | Water sources (BFG & 01 WTP) |
| 79 | Construction, Supplying and installationof French Well/Uttaranchal Koop (Size 1.5m x 1.5m) includingall labour, materials and T & P etc,as per standard specification and drawing as per direction and supervission of engineer in charge, in Series at Raitpur Gadhera (As per Unit Estimate) |
| 80 | Construction of new Boulder Filled Gallary (BFG) includingall labour, materials and T & P etc with 5.0m x 3.0 m sizeas per standard specification and drawing as per direction and supervission of engineer in charge. (As per Unit Estimate) |
| 81 | Construction of new SCC cum Roughening Filter includingall labour, materials and T & P etc with 3m x 2.5 m sizeas per standard specification and drawing as per direction and supervission of engineer in charge. (As per Unit Estimate) |
| 82 | Construction of newWTP 3.0 MLD (Non electric) includingall labour, materials and T & P etc as per standard specification and drawing as per direction and supervission of engineer in charge.at Raitpur Gadhera |
| 83 | Construction of RCC plate form of old RBF No.2 with arrangement of centering path of RBFincluding all labour, materials and T & P etc,as per standard specification and drawing as per direction and supervission of engineer in charge. (As per Unit Estimate) |
| 84 | Development of old RBF no.1 & 2 including dismentling of Tube well, welding equipment with air compressor as per standard specification and drawing as per direction and supervission of engineer in charge. |
| 85 | Constructionof Tin shade for protection of Generator set including all labour, materials ,T & P etc, as per standard specification, drawing and asper direction and supervission of engineer in charge suitable for 100 KVA DG Set |
| 86 | House service connection |
| 87 | Providing and making house service connections from water supply distribution uPVC/ DI/ CI pipe line upto water meter chamber inside the property using MDPE/ HDPE (Class-PE 80) PN 6 composite pipes for upto 5 metre length. The item consisting of composite pipes of MDPE/ HDPE pipe below the ground level and GI class B pipe above the ground level including supply and fixing of ferrules,Saddle, clamps,ball valve, rubber sheets, tapping, compression fittings, end capetc, complete including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer .Including disconnection of Existing connections (Note: Earthwork, Road cutting & restoration & Water meter shall be paid saparately ) (As per Unit Estimate)15 mm Connection |
| 88 | 20 mm Connection |
| 89 | 25 mm Connection |
| 90 | Estimate of Shifting for Existing Connection (15 mm) (As per Unit Estiamte) |
| 91 | Supply of dry dial inferential type, multijet, magnetically coupled class-B tamper, proof Domestic water meters plastic cap pre-equipped for remote reading complete with tubular strainer, brass nuts andnipplesasperIS:779:1994andISO 4064: standard with EEC/MID certification markshall bewithprotectionclassof IP 68 for wirless AMR water meter with guarntee/waranty of following sizes15 mm Connection |
| 92 | 20 mm Connection |
| 93 | 25 mm Connection |
| 94 | Installation of dry dial inferential type, multijet, magnetically coupled class-B tamper proof Domestic water meters plastic cap pre-equipped for remote reading complete withtubularstrainer,brass nutsand nipplesasperIS:779:1994andISO:complete with 4064 standardwithEEC/MIDcertificationmarkshall bewithprotectionclassofIP68 for wireless AMR water meter with gurantee/waranty of following sizes15 mm Connection |
| 95 | 20 mm Connection |
| 96 | 25 mm Connection |
| 97 | AMR Reading system hardware and software wireless meter reading device with display facilities( for walk byand dry by) one reader for minimum 5000 metering points. |
| 98 | Meter reading software which should be handle to catre 20000 AMR water meter connections, with one time licence fees for life Note:- Rates are inclusive of Water Meter data transfer from Meter to Server & to department System for 05 years. i.e during the O&M Period. |
| 99 | Providing, supplying and installation of PP box to accommodate domestic water meter of all sizes including fixing into ground with nails or by any other means such as with hinges including excavation curing etc complete as directed bu EIC. |
| 100 | Pump House and Buildings Works |
| 101 | Construction of Operation Building(45 SQM)as per drawing and technical specification including earth work, PCC work, RCC work, reinforcement, masonry work, plastering, painting, structural steel work etc. as per standard specification and drawing as per direction and supervission of engineer in charge. (As per Unit Estimate) |
| 102 | Construction of Office cum Billing Room (49 SQM) as per drawing and technical specification including earth work, PCC work, RCC work, reinforcement, masonry work, plastering, painting, structural steel work etc. as per standard specification and drawing as per direction and supervission of engineer in charge. (As per Unit Estimate) |
| 103 | Construction of Consumer facilities centre (49 SQM)as per drawing and technical specification including earth work, PCC work, RCC work, reinforcement, masonry work, plastering, painting, structural steel work etc.as per standard specification and drawing as per direction and supervission of engineer in charge. (As per Unit Estimate) |
| 104 | Construction of Boundary wallas per drawing and technical specification including earth work, PCC work, RCC work, reinforcement, masonry work, plastering, painting, structural steel work etc. as per standard specification and drawing as per direction and supervission of engineer in charge. (As per Unit Estimate) |
| 105 | Construction of CC road 5 mtr wide as per drawing and technical specification including all ancillary works. as per standard specification and drawing as per direction and supervission of engineer in charge. |
| 106 | Construction of Pumping Station cum SCADA Room (27 SQM) as per drawing and technical specification including earth work, PCC work, RCC work, reinforcement, masonry work, plastering, painting, structural steel work etc.as per standard specification and drawing as per direction and supervission of engineer in charge. (As per Unit Estimate) |
| 107 | Road Cutting works |
| 108 | Dismantling of flexible pavements and disposal of dismantled materials upto a lead of 100 m, stacking serviceable and unserviceable materials separately as per Technical Specification Clause 202By Manual Means |
| 109 | By Mechanical Means |
| 110 | Dismantling of cement concrete pavements by mechanical means using pneumatic tools breaking to pieces not exceeding 0.02 Cum in volume and stock piling at designated locations and disposal of dismantled materials upto a lead of 1000 m, stacking serviceable and unserviceable materials separately |
| 111 | Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. |
| 112 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 113 | 1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size) |
| 114 | ELECTRICAL EQUIPMENT |
| 115 | LT Panel (As per Unit Estimate) |
| 116 | LV APFC Panel:Supply, installation, testing & commissioning LV APFC panel consisting of required capacitor banks for continuous duty to improve P.F. 0.85 to 0.99 in required steps enclosed in dust & vermin proof compartment, indoor type, fabricated from CRCA sheet steel with minimum thickness of 3 mm for base frame / channel / gland plates, 2.0 mm for load bearing members / doors & 1.6 mm for internal partitions, minimum degree of protection - IP 42, busbar chamber, required size of Al bus bar/ terminals, minimum 10 stage APFC relay, metering, indicating lamps, push buttons, with detuned reactor complete as per IS: 16636-2017 with latest amendment & detailed technical specification and data sheet as under.Upto 50 Kvar capacity: APFC panel consisting following items-a. 125A, 50 kA for 1 Sec, TP, TM based MCCB based spreader terminals & rotary handle.b. 0-125 analogue ammeter of 96 X 96 mm size with selector switch.c. 3 nos 125/5A, 10VA, CL-1.0, cast resin type current transformer.d. Suitable rating MCCB/MCB & contractorfor each capacitor bank.e. Suitable rating APP type capacitor bank (vacuum impregnated with non-PCB/ Non-toxic oil. Internally delta connected with built in internal fuses complete with discharge resistances & thermal cover). Of approved make in required steps with well suited detuned reactor is placed in series with each capacitor step. (e.g. 50 kvar capacity will be provided in steps of 2 nos X 5 kvar, 2 nos X 7.5 kvar & 2 nos x 12.5 kvar).f. Enclosure dimension: 1600 (H) X 1150 (W) X 600 (D) |
| 117 | SITC of Variable Frequency Drives with panel supplied by manufacturer conforming to applicable standards with logic inputs & outputs, relay outputs and analogue outputs, plug in I/O connections, display of electrical parameters, state of load & operating time, RS 485 serial link for connections to Modbus.45 KW |
| 118 | From 3.3 KW to 7.5 KW DOL Starter Feeder with MCB, Main and Aux Contactor, O/L Relay, L/R Selector Switch,3 Indicating lamps, Start-Stop Push Button ,Control MCB (Size : 600 (W) x 400 (H) x 600 (D)Upto 3.7 KW |
| 119 | Pipe Earthing as per PWD specification for electrical Works as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. \" B \" class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurement book. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . |
| 120 | Supply & Laying following size earth strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .50mm x 6mm copper strip |
| 121 | 50mm x 6mm G.I. ( Hot Dipped ) Strip |
| 122 | 25mm x 6mm G.I. ( Hot Dipped ) Strip |
| 123 | S I T C of star rated Aluminium wound distribution Transformer of following rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & as per BEE star level- 2 & BIS approved as per IS 2026- 1977 & losses as defined as per IS 1180 part I 2014. including standard accessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, temperature rise in winding/oil 35-40 degree C upto 200 KVA & 40-45 degree C for above 200 KVA, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint, including carrying of pre-commission Testing & Charging of Transformer complete in all respect .NABL accredited / CPRI/ ERDA lab testing reports with OEM certificate must submitted to engineer in charge .Transformer must be tested from CTL test lab of discom (if reqd.) before charging of transformer & complete installation must be certified from Electrical Inspectorate office as per Indian Electricity rule, CTL testing charges & Inspection charges shall be reimbursed by the department to the contractor as per actual expenditure. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . No Load Voltage ratio : 11/0.433 KVNo. of phases / frequency : 3 Phases/ 50 Hz100 KVA |
| 124 | Supply & Installation of D.P. Structure With AIR BREAK SWITCH having following specifications:- All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .DP : Double pole structure on 2 no ISMB 150 x 100 mm, 10 mtr high using 7 no MS channel each of size 100 mm x 50 mm x 2500 mm complete in all respect with nuts, springs washers, clamps as required.GO:Off load type gang operated 3-pole vertical flute type switch suitable for 11KV ; 400A ,3-ø, central post rotating double break isolator complete with MS hardware , copper moving & fixed contact ,assembly of 9 nos pin insulator ,GI pipe of suitable length for operation.DO: 3nos Vertical / Horizontal mounted 11kv horn gap fuse set /drop out 11kv barrel fuses mounted on 6no pin insulatorsLA: 3 piece non linear resistor type. lighting arrestor of approved make suitable for 3 wire, 11kv Overhead line with rated voltage of 9kv rms & nominal discharge current rating of 5 ka & complete with galvanized clamping arrangement GI bolts, nuts, washer etc as required.JUMPERS: 3 no 11kv acsr conductors mounted on pin type insularors as required. 6.GENERAL:The go shall be operated by hand operated liver properly earthed with provision for locking mounted at 3’ |
| 125 | Supply , Installation, Testing and Commissioning of Silent DG Set (As per latest CPCB emission norms) having specifications as per A, B, C, D, E, F,G,HA. 1500 RPM Diesel Engine conform to BS:649/5514 of suitable BHP Engine shall have residential silencer (isolated from main DG chamber), up to 3 M exhaust piping (with insulation & cladding ) as required .B. AC Brush less SPDP Alternator conform to BS 5000 (part 99) or IS 4722.-2001 . Alternator shall be self regulated with standard Alternator Protection( Over voltage , over speed & under voltage, under speed warning & shutdown).Engine & Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupled.C. Standard canopy with Weatherproof, powder coated Accoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (structure) with side wall fabricated from 1.6 mm CRCA sheet & filled with glass wool (96Kg/m3)/ Foam. as per IS 8183 the doors of 28/40/50/85 mm thick as per rating and fabricated from 1.6mm CRCA sheet packed with accoustic material,All doors/opening are sealed with neoprene/EPDN gaskets. The enclosure has built in fuel tank, with protection and tripping of DG set against temperature of more than 50 degree centigrade.D. Electronic / Mechanical governor, Manual & electric Start ,Batteries with battery charger, Engine instruments panel,AVM pads All controls for operation of DG set are from outside the enclosure with DG control panel having Microprocessor based Genset monitoring & control system, MCCB/ACB of suitable rating, Ammeter, Voltmeter, PF meter, frequency meter, KWH meter,digital fuel display meter, Ind.lamps etc. mounted inside enclosure , visible and accessible from outside. The enclosure should be suitable for following capacity DG sets and alternator. Noise level shall be less than 75 dB at a distance of 1 Mtrs. duly certified by authorised agency etc. complete in all respect of following capacity :E. (A) Accoustic glass wool wall thickness should not be less then 40mm and not less then 20mm PU foam upto rating 100 KVA.(B).Accoustic glass wool wall thickness should not be less then 65mm and not less then 50mm PU foam upto rating 250 KVA.(C)Accoustic glass wool wall thickness should not be less then 100mm for rating above 250 KVA.F. First filling of the fuel tank shall be done by contractor and the prevailing fuel cost at that time shall be reimbursed to the contactor by department.G. Servicing of the DG set (as per OEM guidelines) during the DLP period shall be done by contractor including all consumables,actual charges shall be reimbursed to the contractor by department/client complete in all respect.H. OEM Must have BIS certificate and & shall have submit NABL / CPRI / ERDA/ CPCB standards approved lab type test reports before execution as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached withRadiator Cooled & Turbo Charged /AC82.5 KVA at 0.8 pf 415V 50Hz 3-? |
| 126 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Unarmoured / Armoured aluminium cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:-(a) Material :- H4- Grade aluminium conductor of purity >99.6 % & as per IS:1554 P-I / IS :7098 P – I(b) conductor shall have electrolytic aluminium confirming to IS8130, IS 3975-1999 for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures. (c) OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities for cables . Appropriate type test certificate / OEM test report shall be submitted . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR.3.5 C, 70 Sqmm |
| 127 | 3.5 C, 95 Sqmm |
| 128 | 3 C, 4 Sqmm |
| 129 | 3 C, 35 Sqmm |
| 130 | Supplying and making one end termination with heavy duty single compression brass gland (as per IS 12943- 1990) SIBG type, heavy duty Copper/ Bimetallic lugs (IS 8337- 1976) duly crimped with crimping tool, PVC tape as per PWD specification for electrical Works etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium/copper conductor cable of 1100 volt grade as required of size. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .3.5 C, 70 Sqmm |
| 131 | 3.5 C, 95 Sqmm |
| 132 | 3 C, 4 Sqmm |
| 133 | 3 C, 35 Sqmm |
| 134 | Adding cost of lighting - as per details enclosed |
| 135 | Mechanical Work |
| 136 | Supply, Installation, Testing & Commissioning of horizontal Split casing centrifugal pump motor set of specific duty parameters & guaranteed efficiency of following MOC with specified capacity, horizontal foot mounted TEFC squirrel cage induction motor (with minimum IE-3 efficiency class), working on 3-Ph AC supply with 50 Hz+-3%, Volt +-10%, rated speed 1450 RPM along with fabricated MS base frame, coupling, coupling guard, foundation bolts etc as per relevant IS.M.O.C.: Impeller & wearing Rings: CF8M, Casing: Cast Steel WCB, Shaft: SS410, Shaft Sleeves: SS410, Mechanical Seal (Above 30 Kw), Base Frame: MS588 LPM; Head- 220 Meter; 45 KW |
| 137 | Providing, installation, testing and commissioning of glycerin filled Pressure gauge of following ranges with isolation valve and tap off pipe complete in all respect as per technical specification and as per direction of Engineer.-0 to 4.0 / 0 to 6.0 / 0 to 10.0 kg/cm² |
| 138 | Providing, lowering, laying, aligning, fixing in position in pipe line, Resilient Seated D/F DI Sluice valves of approved make & design standard of following dia complete (including jointing & jointing material ) including all material, labour, testing and commissioning along with pipe line as per Technical Specification & as per direction of Engineer. Electrically Operated & SCADA Compatible class PN 2.5; 150 mm |
| 139 | Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) Swing type Non Return Valve of approved make of following Pressure rating & dia complete, generally confirming to IS: 5312 (part -1)/ 2004 (amended up to date) and of following specifications: Body, Bonnet & disc of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per IS 5312 (part -1):2004 Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body, cover and disc inside and outside . Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 410, Hinge SS AISI 316/410 ,Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR \"O \"ring seal Nut-Bolt confirming to IS:1363 and IS: 1367 (galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.Class PN 1.6150 mm |
| 140 | Fabrication, supply of flanged/ plain ended MS pipe made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete (excluding flanged jointing wherever required) including all material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer.MS pipe specials up to 600mm dia (with minimum 5mm thickness sheetColumn pipe |
| 141 | 900 Bend |
| 142 | AF Tee |
| 143 | DF Pipe |
| 144 | Providing, installation, testing and commissioning of Electromagnetic Flow Meter etc. including all materials (excluding CI/DI fittings) and making connection with existing pipeline required for Electromagnetic Flow Meter including cutting the existing pipe line etc. complete in all respect as per technical specification and as per direction of Engineer.150 mm |
| 145 | Supplying, erecting, testing & commissioning of Hand operated Travelling Crane (HOT) (single bridge girder carrying two wheels , complete with chain pulley block, load chain of welded construction of alloy steel as per IS:2429, hand chains for hoisting & traverse mechanism, totally encased Gears, trolley, trolley track wheels. Axle & shaft, swivel type lifting hook as per IS:3815, lock to prevent hook from swivelling, brakes for lifting gear, suitable for the above parameters and as per the direction of the Engineer.2 MT Capacity; Span 9 M and Lift 3 M |
| 146 | Add extra for additional per metre lift. |
| 147 | SCADA WorksCentralised SCADA Control Room |
| 148 | Design, manufacture, supply, installation, testing and commissioning of indoor type PLCpanel of size 1200 mm x 800 mm x 2100mm (lbh) , fabricated out of approx.min. 2 mm thick CRCA sheet Steel complete with latestconfiguration PC, necessary programming andScada software and comprising of all accessories Not limited to the following CENTRALISED REDUNDANT PROCESSORFor 12 RTU Station GIS based Communication & All field Instrument |
| 149 | FORDICHANNEL-Card with 16 channel & with base channels |
| 150 | FORDOCHANNEL-Card with 16 channel & with base channel |
| 151 | RELAY CARD -with8 channels |
| 152 | AICHANNEL - card with8 channels & with base channels |
| 153 | AO CHANNEL- card with4 channels & with base channels |
| 154 | SCADA Software & Centralised Cloud Based System, Data Aciquisition & Remote Monitring etc. |
| 155 | Programming Software |
| 156 | Communication Card With Cable |
| 157 | System Cabinet/ Panel |
| 158 | 24V Dc Power Supply Redundant |
| 159 | Remote I/O Panel |
| 160 | Server |
| 161 | Marshalling Panel |
| 162 | Hardware Switchgear Lot |
| 163 | Computer-32\"LED–Engg. Stn.1No .& Operating Stn-1 Nos.. Total -2 Nos.. |
| 164 | CommonDeskTop for Centralised SCADA Center |
| 165 | Lazer Printer-A4- Colour |
| 166 | Printer |
| 167 | Aux. Contactor-Lot |
| 168 | Furniture |
| 169 | Air Conditioner-1.5 T |
| 170 | UPS-Redundant 2Kva, 150 AH*2 Battery Unit, Backup For 3 Hours Backup |
| 171 | Remote Data Transer GSM/GPRS Modem -Wireless At Sending / Receiving End |
| 172 | RTU PANEL WITH HMI AT -3 Location |
| 173 | Design, manufacture, supply, installation, testing & commissioning of indoor type PLCpanel with 10” HMI, withsize 800 mm x 800 mm x 2100mm (lbh) , fabricated out ofapprox. min. 2 mm thick CRCAsheet complete with , necessary programming and HMI software and comprising of all accessories not limited to the following REDUNDANT PROCESSORwith48nos. I/O capacity with 10” HMI |
| 174 | FORDICHANNEL-Card with 16 channel & with base channels |
| 175 | FORDOCHANNEL-Card with 16 channel & with base channel |
| 176 | RELAY CARD -with8 channels |
| 177 | AICHANNEL - card with8 channels & with base channels |
| 178 | AO CHANNEL- card with4 channels & with base channels |
| 179 | HMI with ProgrammingSoftware |
| 180 | Communication Card With Cable |
| 181 | System Cabinet/ Panel |
| 182 | Power Supply Redundant |
| 183 | Hardware & Software Development–Lot |
| 184 | Remote Data Transfer GSM/GPRS Modem -Wireless At Sending / Receiving End With Dual Sim |
| 185 | UPS- 2 Kva with 150 AH*2 Battery Unit, Backup For 3 Hours for RTU Panel Location |
| 186 | RTU PANEL AT- 6 Location of Service Reservoir |
| 187 | Design, manufacture, supply, installation, testing & commissioning of indoor type PLCpanel with 10” HMI, withsize 800 mm x 800 mm x 2100mm (lbh) , fabricated out ofapprox. min. 2 mm thick CRCAsheet complete with , necessary programming and HMI software and comprising of all accessories not limited to the following REDUNDANT PROCESSORwith48nos. I/O capacity with 10” HMI |
| 188 | FORDICHANNEL-Card with 16 channel & with base channels |
| 189 | FORDOCHANNEL-Card with 16 channel & with base channel |
| 190 | RELAY CARD -with8 channels |
| 191 | AICHANNEL - card with8 channels & with base channels |
| 192 | AO CHANNEL- card with4 channels & with base channels |
| 193 | Communication Card With Cable |
| 194 | System Cabinet/ Panel |
| 195 | Power Supply Redundant |
| 196 | Hardware & Software Development–Lot |
| 197 | Remote Data Transfer GSM/GPRS Modem -Wireless At Sending / Receiving End With Dual Sim |
| 198 | UPS- 2 Kva with 150 AH*2 Battery Unit, Backup For 3 Hours for RTU Panel Location |
| 199 | Supply ofElectronically controlled, electrically actuated,diaphragm operated, chemical metering pump, wall mounting suitable for delivering up to 6 litres of chemical solution/sodium hypochlorite solution per hour under maximum delivery pressure up to 6.0 KG/cm2 and suction lift not less than 1.5 meter with accessories. |
| 200 | PRESURE TRANSMITTER AT DISCHARGE OF PUMPPRESSURE TRANSMITTERS- FOR ONLINE PRESSURE MEASUREMENT |
| 201 | Providing, Installation, Testing and Commissioning of Pressure Transmitter : Range: 0-10 Bar / Power Supply: 24 V DC / Output: 4-20 mA with HART / Diaphragm: SS316L / Process Connection: 1/2 \"NPT (M) / Accuracy: 0.15% Protection: IP67 |
| 202 | LEVELTRANSMITTER FORGLSR, SUMP & Service ReservoirSupply, Installation, testing and commissioning of Battery Operated Ultrasonic Level Transmitters with an accuracy of ± 0.25% of full scale, ingress protection IP 65, MOC electronic enclosure Aluminium die cast/SS316, battery life of min. 5 years, LCD display 8 X 1 character as per technical specifications; 0 to 6 Mtr. |
| 203 | pHANALYSER:pH Analyser: Transmitter: Range: 0-14 pH, Power Supply 230 VAC, Input: One Digital Sensor, Output: 4-20mA HART, IP66 Protection / Tx protection cover required / Sensor Range 0-14 pH , able to transmit digital signal to transmitter, calibration data can be transferred to Transmitter , process temp: 65 deg cen/ flow through tee MOC SS. |
| 204 | Turbidity Analyser:Providing, installation, testing and commissioning of Turbidity Analyser : Range - Selective 0 to 4000 NTU, Accuracy:+/-2% of reading or +/-0.02NTU; Compliance to US EPA180.1, With inbuilt transmitter with 4-20 mA output , Relay contacts & Modbus communication. |
| 205 | Providing, installation, testing and commissioning of followings instruments as per CBCP/SPCB guidelines.Chlorine Analyser : Transmitter : Range: 0.05 to 20 ppm, Power Supply 230 VAC, Input: 2 Digital Sensors - one for chlorine and second for pH, Output: 4-20mA HART, IP66/67 Protection / Tx protection cover required / Sensor Range 0-14 pH , able to transmit digital signal to transmitter, calibration data can be transferred to Transmitter , process temp: 65 deg cen/ Sensor range:0.05 to 20 mg/l. |
| 206 | Providing, installation, testing and commissioning of Electromagnetic Flow Meter etc. including all materials (excluding CI/DI fittings) and making connection with existing pipeline required for Electromagnetic Flow Meter including cutting the existing pipe line etc. complete in all respect as per technical specification and as per direction of Engineer65 mm |
| 207 | 80 mm |
| 208 | 100 mm |
| 209 | 125 mm |
| 210 | 200 mm |
| 211 | Providing, lowering, laying, aligning, fixing in position in pipe line, Resilient Seated D/F DI Sluice valves of approved make & design standard of following dia complete (including jointing & jointing material) including all material, labour, testing and commissioning along with pipe line as per Technical Specification & as per direction of Engineer.; Electrically Operated & SCADA Compatible class PN 1.6125 mm |
| 212 | EARTHING SYSTEM : |
| 213 | SITC of chemical Gel earthing system of Dual Pipe Technology made of with \"B\" Class G I Pipe as per IS 1239 ( part-1):2004 of Medium duty of following sizes as per points mentioned (a), (b), [c),(d), (e) below :-(a) filled with anti corrosive conductive compounds with the permanent sealings at both the ends, CPRI/ ERDA tested with RMS capacity of minimum 35- 40 KA for withstanding 1 second .(b) To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated lab for low resistivity ( less than 0.12 Ohm - meter) & high conductivity in nature with carbon as a major content as per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts(c) Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm.(d) Testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurement book.(e) Self certificate for confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .With Pipe in Pipe Technology (Outer pipe dia. / Inner pipe dia. ) Minimum 100 mm dia borewell; GI pipe 2000 mm long, 50 / 25mm, Terminal 40mm x 6 mm GI Strip |
| 214 | Supply & Laying following size earth strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,Jointing shall be done by overlapping and with 2 set of Brass (for Custrip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/work , refer Annexure \"A\" attached with this BSR .25X6 mm GI Strip |
| 215 | Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu thimble etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .8mm GIWires |
| 216 | 12 SWG Wire ForInstrument |
| 217 | Providing and laying XLPE/PVC insulated & PVC sheathed armoured control cables of 1.1 KV grade with copper conductor as per IS 1255 including excavationj of 30 CmX75 Cm size trench 25 Cm thick under layer of sand and Iind class bricks covering10C x 1.5 sq.mm |
| 218 | Operation, Maintenance & Repairing of Newly Constructed Water Supply Scheme having 05 DMA Comprising of 07 Nos. CWRs,Rising Mains, Gravity main, distribution Pipe Lines ofvariousDiameters, Water Connections for 05 Years including Repairing of Pipe Line Leakages,Removal of Pipe Line Chockages,Water Connections with required all material (Fittings & Specials) ,Labour, Cartage,T&P etc. complete of various Materials and Diameters, Valves Operation, DG Set. Operation & maintenance, Repairing of damaged Pumping Plants including Lowering/Lifting, Repairing of Electrical Instruments/Starters/Switch gears/ Protection Instruments, Main Switches, Cutouts, Cables,Change Over Switch etc., Repairing of Various types of Sluice Valves/Non Return Valves/Air Vaves/Scour Valves/Flow Meter.Fire Hydrants /etc.Supply, Transportation, Loading/Unloading, Mixing & Injecting of Sodium Hypo Chloride Solutions for Dosing including maintenance of Dosing Pumps/Analyser, Maintenance of Servo Voltage Stabilizers with Spares, SCADA related Electrical Instruments/ Panels/Computers/Printer Pressure Transmitters, Meter Reading/ maintenanance of Water Meters,OHT/CWRs Water Lever Indicater/Ground Water Level Indicater, Distribution of Bills,Collection of Water Samples & O.T. Testing,Distribution of Water through Water Tankers in case of failure of Water Supply,Repairing of Civil Work such as Scada Control Room ,Pump House/OHT,Valve Chambers/ Boundary Wall ,Entrance Gate etc. Revenue Collection,Customer Grievances addresal Excluding Electricity Charges.1) During First Year |
| 219 | 2) During Second Year |
| 220 | 3) During Third Year |
| 221 | 4) During Fourth Year |
| 222 | 5) During Fifth Year |