Public Works Department-PWD has published Tender For Replacement And Supply, Installation, Testing, Commissioning Of Air Handling Units In Trauma Centre At Sms Hospital , Jaipur. Submission Date for this Tender is 30-09-2023. Air Handling Unit Tenders in Jaipur Rajasthan. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 20-Sep-2023 | work period | Other | 28-09-2023 |
2 | 24-Sep-2023 | boqpdf | Other | 28-09-2023 |
3 | 29-Sep-2023 | Due Date Extended | Admin Corrigendum Date Extend | 30-09-2023 |
Sl. No. | Item Description |
1 | Supply , Installation, Testing and Comissioning of site fabricated ducting made from GI sheet metal conforming to IS:277 with a zinc coating grade not less than 120 GSM (both side inclusive)& fabricated as perIS:655 and as per approved drawings & designs including the cost of hangers, supports, angle, expansion fasteners , closed cell neoprene gasket T&P etc. as required of following thickness. Test Certificate for Galavanizing with lot no. to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR . |
2 | 0.80mm |
3 | Supply , installation, testing & balancing of 20 Gauge G I Damper with brass bushes and 6" pitch multiblade box type galvanised sheet steel construction volume control damper for Ducting and air washers to be provided with suitable links and quadrants for control of volume of air as per specifications complete as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR . |
4 | Supply & fixing of external thermal closed-cell Nitrile rubber Insulation material FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified "Class O" in Fire Propagation(as per BS 476 Part 6 in form of sheet on duct,under deck,AHUrooms,indoorspace etc) including cost of adhesive (CPRX Compound) complete as required.All as per pre approved by Engineer in charge. |
5 | 13mm thick for Outdoor Application with 26 SWG Aluminium Cladding |
6 | Supplying , installing, testing and commissioning of following capacity New double skin floor mounted type Air HANDLING UNIT on buy back basis of existing old 4400 CFM ZECO make AHU(Removal, dismentlling,pumpdown the referegent,transportation,cleaning of site etc as directed by engineer incharge).New AHU should be with with 25 mm thick panel PUF CFC FREE DENSITY 42±2 kg/M3 with thermal break property . the AHU inner skin shall be 0.6 mm pre coated GI , THE AHU outer skin shall be 0.6 mm pre coated GI with colour.complete with fan section centrifugal back-word curved DIDW type fan(s), belt drive , vibration isolators, prefilter (EU 4) effiency90% down to 10 micron mixing box for return air , fresh air. SS drain pan.6 rowdeep DX cooling coil of copper tube & aluminium fins, 12-13 FPI , mixing box with inlet louvers,system is completed with fresh air intake and bleed module with filtration , bypass filter not more then 0.12.fan motor shall be suitable for 415±10%volts, 50Hz , 3 phase ACsupply and shall be high efficiency(IE-2 Class).including fresh air , return air , supply air damper with air volume control. |
7 | AHU(CFM) TYPE RD SP(mm) PHASE |
8 | 4400FM 61103 |