| 1 | Sub Head : Laying of pipeline |
| 2 | Excavating trenches of required width for pipes, cables etc. including exacavation for sockets, dressing of sides where required, ramming of bottoms, depth upto 1500 mm including getting out the excavated soil and backfilling of soil as required after laying of pipeline, in layers not exceeding 200 mm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil with all required leads as per Chapter - 2 of CPWD specification and direction of the Engineer - in - charge. |
| 3 | A. For UPVC pipes in new work a). In all kinds of soili. For pipes not exceeding 90 mm dia |
| 4 | A. For UPVC pipes in new work a). In all kinds of soiliI). For pipes exceeding 90 mm dia but not exceeding 300 mm dia |
| 5 | B). For G.I. / C.I. / D.I. pipes in new worka). In all kinds of soilii). For pipes exceeding 90 mm dia but not exceeding 300 mm dia |
| 6 | Providing, fixing and laying rigid UPVC pipes conforming to IS : 4985 jointing with couplers, of same class conforming to IS : 10124 ( Pt-II ) with solvent cementconforming to IS : 14182 including testing of joints complete ( but excluding the cost of specials like bend, tees etc. which will be paid separately ) as perCPWD specification and direction of the Engineer - in - charge. A). Class - 3 ( working pressure 6.0 kg / cm2) |
| 7 | i) 40 mm OD |
| 8 | i) 50 mm OD |
| 9 | i) 90 mm OD |
| 10 | ii) 110 mm OD |
| 11 | iii) 140 mm OD |
| 12 | Providing and laying S & S Centrifugally Cast ( Spun ) Ductile Iron Class K-7 Pipes conforming to IS : 8329 as per CPWD specification and direction of the Engineer - in - charge. |
| 13 | i) 150 mm dia |
| 14 | Charges for push-on ( Tyton ) joints to centrifugually ( Spun ) cast iron pipes or ductile iron pipes including testing of joints and including the cost of rubber gasket as per chapter 20 of CPWD specification and direction of the Engineer - in - charge. |
| 15 | iv) 150 mm dia |
| 16 | Providing and fixing C.I. sluice valves ( with cap ) complete with bolts, nuts, rubber insertions etc. ( the tail pieces if required will be paid separately ) as per chapter 20 of CPWD specification and direction of the Engineer - in - charge. |
| 17 | iv). 150 mm dia. A) PN - 1.6 |
| 18 | Charges for cutting D.I. pipe with steel saw by manual means as per CPWD specification and direction of the Engineer - in - charge. |
| 19 | iii) 150 mm dia |
| 20 | Providing and laying D.I. specials of class K - 12 suitable for push -on jointing as per IS : 9523 as per chapter 20 of CPWD specification and direction of the Engineer - in - charge.i) Upto 300 mm dia |
| 21 | Constructing masonry Chamber 90 x 90 x 100 cm, inside with brick work in cement mortar 1 : 4 ( 1 cement : 4 fine sand ) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with chained lid and RCC top slab 1 : 2 : 4 mix ( 1 cement : 2 fine sand : 4 brick aggregate 1st class 20 mm nominal size ) necessary excavation foundation concrete 1 : 5 : 10 ( 1 cement : 5 fine sand : 10 brick aggregate 1st class 40 mm nominal size ) and inside plastering with cement mortar 1 : 3 ( 1 cement : 3 fine sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design, CPWD specification and direction of the Engineer - in - charge.A). With First class bricks |
| 22 | Providing and fixing brass ferrule with C.I. cover conforming to IS :2692 including boring and tapping the main as per chapter 20 of CPWD specification and direction of the Engineer - in - charge.ii) 15 mm nominal bore |
| 23 | Providing and laying of flexible PVC pipe (conforming to IS:7634) complete as per specification and direction of the Engineer - in charge (cost of earth work and fittings will be paid separately). |
| 24 | i. 15 mm dia |
| 25 | ii. 20 mm dia |
| 26 | Providing and fixing G.I. socket as per CPWD specification and direction of the Engineer - in - charge.i) 15 mm dia |
| 27 | Providing and fixing G.I. union as per CPWD specification and direction of the Engineer - in - charge. |
| 28 | i) 15 mm dia |
| 29 | Making road crossing by horizontal boring for smooth laying of UPVC / CI / DI / GI pipes etc. of required dia complete as per specification and the direction of the Engineer-in-charge.B). by manual means |
| 30 | Cutting bitumminous road (30 cm average depth) including getting out the dexcavated road materials and refitting the same.a). Stone aggregate. |
| 31 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering –a) All work upto plinth level:i) 1:2:4 ( 1 Cement: 2 fine sand : 4 graded stone aggregate 20 mm nominal size) |
| 32 | Constructionofsurface drain 250 mm. wide, 150 mm.deepand125 mm. side walls with 2nd class brick masonry work 1:4(1 cement: 4 river sand) on 100 mm. thick cement concrete bed of mix 1:5:10(1cement:5river sand: 10 jhama aggregate 40 mm. nominalgauge)and cement concrete 1:2:4 mix (1 cement: 2 river sand sand: 4 jhama aggregate 12.5 mm.nominal gauge) in drains including finishing |
| 33 | Providing and fixing G.I. Reducer with the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.i)100 x 80 mm dia |
| 34 | Providing and fixing G.I. Bend /elbow in the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.i) 15 mm dia. |
| 35 | Providing and fitting fixing PVC / plastic bib cock conforming to IS : 9763 in hydrant points at different locationas per specification & direction of the Engineer-in-charge.i) 15 mm dia PVC /plastic bib cock |
| 36 | Providing and fixing G.I. Nipple of medium class as per chapter 20 of CPWD specification and direction of the Engineer - in - chargeiii)15 mm dia 225 mm long |
| 37 | Providing andfixing DI specials as perCPWD specification and direction of the Engineer - in - charge. |
| 38 | A. D.I. Flanged Socketted tail piece |
| 39 | i). 150 mm dia |
| 40 | B. D.I. Flanged Spigotted tail piece |
| 41 | ii). 150 mm dia |
| 42 | C. D.I. all socketted tee |
| 43 | ii)150 x 150 x 100 mm dia |
| 44 | D) D.I. all socketted Bend 90 degree |
| 45 | ii) 150 mm dia |
| 46 | Providing & fitting fixing of MS flange ( 8 mm wall thickness ) by welding with G.I. / MS pipe and placing position as per specification and the direction of the Engineer-in-charge. |
| 47 | iv). 150 mm dia |
| 48 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 49 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.-All kinds of soil |
| 50 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. -All kinds of soil |
| 51 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. \"-All kinds of soil |
| 52 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering --All work upto plinth level:1:3:6 ( 1 Cement: 3 fine sand : 6 graded stone aggregate 40 mm nominal size) |
| 53 | 5.1 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement-All work upto plinth level:1) 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 54 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses,plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement-5.2.2 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 55 | Providing and fixing in position Precast RCC hydrant post enraved with logo of JJM and other necessarry details of size 150 x 150 mm at the bottom & 150 x 150 mm at the top and 1500 mm Long ( made with cement concrete 1 : 2 : 4 ( 1 cement : 2 sand : 4 stone aggregate of 10 mm nominal size) and steel reinforcement ( TMT bars ) 8 mm dia 1200 mm long 4 nos and 8 mm dia stirrup 11 Nos ), 300 mm shall be kept below ground level , embedding the same with in 500 x 500 x 500 mm cement concrete 1 : 5 : 10 ( 1 cement : 5 sand : 10 Stone aggregate of 40 mm nominal size ) as per approved drawing, including plastering the exposed surface with 6 mm thick cement mortar 1 : 4 ( 1 cement: 4 sand ) finished with a floating coat of neat cement ) including providing & embedding 15 mm dia G.I. pipe (medium class) 1250 mm long with necessary GI fittings like elbow 2 Nos, socket 1 no, nipple 300 mm long 1 no, union 1 no etc. and fitting fixing of CI long handle bib cock by welding with GI socket complete with all earth work required including refilling as per CPWD specification and direction of Engineer-in-charge. |
| 56 | Providing and fixing in position Precast RCC platform of size 750 x 750 mm x 75 mm with curb of size 60 x 50 mm keeping an opening of 100 mm long in a suitable place for draining out of water ( made with cement concrete 1 : 2 : 4 ( 1 cement : 2 sand : 4 Stone aggregate20 mm nominal size) and steel reinforcement ( TMT bars ) 6 Nos, 8 mm dia in both direction including plastering the exposed surface with 6 mm thick cement mortar 1 : 4 ( 1 cement: 4 sand ) finished with a floating coat of neat cement ) complete with all earth work required including refilling as per CPWD specification and direction of Engineer-in-charge |