Tender For Misc Repair/Replacement To Summer Appliances, Split Ac, Window Ac And Other Connected Misc E/M Works Under Ge (East) Delhi Cantt-10, delhi-Delhi

Military Engineer Services-MES has published Tender For Misc Repair/Replacement To Summer Appliances, Split Ac, Window Ac And Other Connected Misc E/M Works Under Ge (East) Delhi Cantt-10. Submission Date for this Tender is 16-10-2023. Air Conditioner Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

39723277
Corrigendum : Tender For Misc Repair/Replacement To Summer Appliances, Split Ac, Window Ac And Other Connected Misc E/M Works Under Ge (East) Delhi Cantt-10
Open Tender
Indian
Delhi
delhi
16-10-2023

Tender Details

Misc Repair/Replacement To Summer Appliances, Split Ac, Window Ac And Other Connected Misc E/M Works Under Ge (East) Delhi Cantt-10

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 26-Sep-2023 Corrigendum No 1 DE-65 Other 09-10-2023
2 09-Oct-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 16-10-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 88640.0 /-
Tender Value
INR 44.32 Lakhs /-

BOQ Items

Name of Work: MISC REPAIR/REPLACEMENT TO SUMMER APPLIANCES, SPLIT AC, WINDOW AC AND OTHER CONNECTED MISC E/M WORKS UNDER GE (EAST) DELHI CANTT-10
Sl. No. Item Description
1Attending the break down complaint of all nature for window/split AC/tower AC/ cassette AC and their electrical wiring from main DBs of any capacity and make them functional and also carry out the required repair on all days including Sunday and holidays complete all as specified and directed. Notes- (i) Store required for repairs shall be measured and paid separately under respective item of this Schedule as "Supply only". (ii) Adequate resources shall be deployed by the contractor for attending day to day defect being an essential installation. (iii) All complaint/repairs shall be attended/completedwithin 06 Hour failing which a recovery of Rs 1000/- per day per complaint shall be made from contractor dues.
2M&L for servicing of window type AC of 1.0/1.5/2.0 TR capacity, of any type/make, at site /wall, comprising of taking down carefully, removing power connections and front PVC grills, air filters, cleaning, washing, removing dirt, servicing including chemical wash of cooling coil, indoor cooling unit and condenser coil and providing oil and grease to all moving parts including condensing motor, checking and making serviceable electrical connection of DB"s, stabilizer, wiring of AC"s as per site condition and tightening all electrical connection with thimble and replacing the spare parts of the AC units wherever required, testing & commissioning including refixing at the original position and connecting with the system complete all as specified and as directed. Notes:- (i) Contractor shall maintain register of servicing as per format given by Engr-in-Charge duly signed by User, where the servicing of equipment carry out and produce as & when asked by Engr-in-Charge or GE. (ii) Spare parts required for repairs shall be measured and paid separately under respective item of this Schedule as supply only.
3M&L for servicing of split type AC of 1.5/2.0 TR capacity, of any type/make, at site /wall, including removing power connections and front PVC grills, air filters, cleaning, washing, removing dirt, servicing including chemical wash of cooling coil, cooling unit and condenser coil of outdoor unit, checking and making serviceable electrical connection of DB"s, stabilizer, wiring of AC"s as per site condition and tightening all electrical connection with thimble and replacing the spare parts of the AC units wherever required, testing & commissioning including refixing at the original position and connecting with the system complete all as specified and as directed. Notes:- (i) The cost of additional inlet/outlet copper pipes, drain pipe and electrical cord, if required and making good of surface as original by plastering/ whitewash/ colour/ distemper etc shall deemed to be included in quoted rate and no extra payment shall be made to contractor on this account. (ii) Contractor shall maintain register of servicing as per format given by Engr-in-Charge duly signed by User, where the servicing of equipment carry out and produce as & when asked by Engr-in-Charge or GE . (iii) Spare parts required for repairs shall be measured and paid separately under respective item of this Schedule as supply only.
4All as per srl item No 3.00 here-in-before but Tower type split AC of any capacity complete all as specified and as directed.
5Supply only of remote for window/ split type AC any type and any capacity as per existing make/ model at site cpmplete all as specified and directed.
6Taking down, repairing and re-fixing PCB, suitable for inverter type/ non inverter type split AC/ window AC ofany capacity and modelcomplete all as specified and directed.
7S&F in replacement of PCB, suitable for inverter/ non-inverter type, split AC/ window AC of any capacity and model complete all as specified and as directed.
8Taking down, repairing and re-fixingPCB, suitablefor tower type AC/ cassette type AC ofany capacity and modelcomplete all as specified and directed.
9S&F in replacement of PCB suitable for tower type AC/ cassette type AC of any capacity and model complete all as specified and as directed.
10M&L for making necessary arrangement/alteration to make reversible system (reverse valve) to functioning as heat engine in winter i.e. cooling in summer and heating in winter, by providing necessary copper tubing, refrigerant valve, modification in remote unit (PCB) and allied work for the split/ window Air Conditioner of 1.5/2.0 TR capacity complete all as specified and as directed. Note: Charging of refrigerant gas, if required, shall be measured and paid separately.
11S & F in replacement sealed compressor unit, reciprocating type/ rotary type/ Scroll type, suitable for 1.5 TR window type AC/ Split AC of existingcapacity and makecomplete all as specified and as directed.
12S & F in replacement sealed compressor unit, reciprocating type/ rotary type/ scroll type, suitable for 2.0 TR window type AC/ Split AC of existingcapacity and makecomplete all as specified and as directed.
13S & F in replacement sealed compressor unit, reciprocating type/ rotary type/ scroll type, suitable for 3.0 TR tower type AC suitable for 3 phase supply of existingcapacity and make complete all as specified and as directed.
14S&F in replacement sealed compressor unit, reciprocating type/ rotary type/ scroll type,, suitable for 3.5 TR Tower type AC, 3 phase power supplyof existingcapacity and make complete all as specified and as directed.
15S&F in replacement sealed compressor unit, reciprocating type/ rotary type/ scroll type,, suitable for 4.5 TR Tower type AC, 3 phase power supplyof existingcapacity and make complete all as specified and as directed.
16Supply only in replacement window AC Kit internal wiring for 1.5 / 2.0 TR capacity AC complete all as specified and as directed.
17Supply only in replacement Split type AC Kit internal wiring for 1.5 / 2.0 TR capacity AC complete all as specified and as directed.
18Supply only in replacement drain pipe PVC medium grade size 25 mm dia including fittings complete all as specified and as directed.
19Supply only in replacement drain pipe PVCtype 15/20 mm dia including fittings complete all as specified and as directed.
20Supply only in replacement starting capacitors 80 -100 MFD complete all as specified and as directed.
21Supply only in replacement starting capacitors 100 -120 MFD complete all as specified and as directed.
22Supply only in replacement running capacitor 50+6 MFD complete all as specified and as directed.
23Supply only in replacement running capacitor 45+6 MFD complete all as specified and as directed.
24Supply only in replacement capacitor 4 MFD complete all as specified and as directed.
25Supply only in replacement Capacitor 6 MFD complete all as specified and as directed.
26Supply only in replacement indoor unit swing motor, suitable for split AC of existingcapacity and model complete all as specified and as directed.
27Supply only in replacement Split AC Indoor Unit blower motor, single shaft suitable for existingcapacity and make complete all as specified and as directed.
28Supply only in replacement Indoor unit Air blower for Split type AC 1.5/2.0/3.0 TR complete all as specified and as directed.
29Supply only in replacement display suitable for Split type AC/ window type AC of existing make complete all as specified and as directed.
30Supply only in replacement Split AC outdoor unit fan motor for any capacity, Single shaft suitable for existingmake and model complete all as specified and as directed.
31Taking down repairing/rewinding and fixing Split AC ODU fan motor for any capacity of Single shaft suitable for existingmake and model complete all as specified and directed.
32Supply only in replacement fan blade of Condenser motor for Split AC of capacity 1.5TR/2.0 TR complete all as specified and as directed.
33Supply only in replacement fan blade of motor for window AC of capacity 1.5TR/2.0 TR complete all as specified and as directed.
34Supply only in replacement Motor suitable for window type AC of existing capacity, double shaft complete all as specified & as directed.
35Taking down repairing/rewinding and fixingMotor suitable for window type AC of existingcapacity , double shaft complete all as specified & directed.
36Supply only in replacement Air blower for Window type AC 1.5/2.0 TR complete all as specified and as directed.
37Supply only in replacement cooling coil made out of copper tube & Aluminium fins of window AC 1.5/2.0 Ton complete all as specified and as directed.
38Supply only in replacement condenser coil made out of copper tube & Aluminium fins complete of window AC 1.5/2.0 TR as per existing system complete all as specified and as directed.
39S&F in repair Evaporator Coil made out of copper tube & Aluminium fins, suitable for indoor unit of split AC of capacity 1.5/2.0 TR of existing make and model complete all as specified and as directed.
40S&F in repair Condenser Coil, size 24 inch and 2 row, made out of copper tube & Aluminium fins, suitable for Outdoor Unit of split AC of capacity 1.5/2.0 TR of existing make and models complete all as specified and as directed.
41S&F in repair Evaporator Coil made out of copper tube & Aluminium fins, suitable for indoor unit of Tower type AC of 3.0/4.0/4.5 TR capacityof existing make and model complete all as specified and as directed.
42S&F in repair Condenser Coil, made out of copper tube & Aluminium fins, suitable for Outdoor Unit ofTower type AC of 3.0/4.0/4.5 TR capacity of existing make and models complete all as specified and as directed.
43Supply only in replacement starting relay suitable for window type AC/ split type AC of existingcapacity and make complete all as specified and as directed.
44Supply only in replacement over load protector relay for window type AC/ Split type AC of any capacity complete all as specified and as directed.
45Supply only in replacement starting relay suitable for tower type AC of existingcapacity and make complete all as specified and as directed.
46Supply only in replacement over load protector relay for tower type AC of any capacity complete all as specified and as directed.
47S&F in repair contactor of suitable capacity for split type AC of any capacity complete all as specified and as directed.
48Supply only in replacement PVC insulated, multi stranded, 3 core, flexible, copper conductor cable, of size 2.5 sqmm complete all as specified and as directed.
49Supply only in replacement PVC insulated, multi stranded, 3 core, flexible, copper conductor cable, of size 4.0 sqmm complete all as specified and as directed.
50Supply only in replacement flexible copper conductor cable 4.0 Sqmm, 4 core, PVC insulated & PVC sheathedcomplete all as specified and directed.
51Supply and charging R-22 refrigerant gas, including and after carrying out the pressure test with nitrogen and rectify the leakage of split AC/window AC/ water cooler/ tower AC/Cassette AC complete all as specified and as directed.
52Supply and charging R-134A refrigerant gas, including and after carrying out the pressure test with nitrogen and rectify the leakage of split AC/window AC/ water cooler/ tower AC/Cassette AC complete all as specified and as directed.
53Supply and charging R-410A refrigerant gas, including and after carrying out the pressure test with nitrogen and rectify the leakage of split AC/window AC/ water cooler/ tower AC/Cassette AC complete all as specified and as directed.
54Supply and charging R-32 refrigerant gas, including and after carrying out the pressure test with nitrogen and rectify the leakage of split AC/window AC/ water cooler/ tower AC/Cassette AC complete all as specified and as directed.
55Supply only in replacement front grill as per sample, suitable for existing model of window type AC 1.5TR/ 2.0 TR capacity complete all as specified and as directed.
56Supply only in replacement front grill as per sample suitable for 1.5 TR/ 2.0 TR capacity Split type AC complete all as specified and as directed.
57Supply only in replacement copper pipe 1/2” dia, wall thickness 0.032 mm including insulation complete all as specified & as directed.
58Supply only in replacement copper pipe 1/4" dia, wall thickness 0.030 mm including insulation complete all as specified & as directed.
59Supply only in replacement copper pipe 5/8" dia, wall thickness 0.035 mm including insulation complete all as specified & as directed.
60Supply only in replacement copper pipe 3/8" dia, wall thickness 0.032 mm including insulation complete all as specified & as directed.
61S&F in replacement copper tubing 6/8" dia & wall thickness 0.039 mm including insulation complete all as specified and directed.
62S&F in replacement of Pin/service/ charging valve of size 1/2", 1/4", 3/8", 5/8" for window AC and Split AC of existing model complete all as specified and as directed.
63S&F in replacement of outdoor stand of floor mounted type/ Wall mounted type with fastener for split AC complete all as specified and as directed.
64Supply only in replacement plug top 3 pin, 15 Amp, complete all as specified & as directed.
65M&L for shifting of Split type AC of any capacity, any type/make, with stabilizer including taking down carefully indoor and outdoor unit, copper piping, drain pipe and thermal sleeve, lifting angle etc and installing the same to new location using existing copper piping for suction and delivery with insulation, drain pipe and re-fixing arrangement i. e. lifting angle, fasteners, nut bolt, washer etc, testing & commissioning complete all as specified and directed. Notes: (i) The cost of making hole for passing through inlet/outlet copper pipes, drain pipe and electrical cord and making good of surface at both location as original by plastering / whitewash / colour / distemper etc shall deemed to be included in quoted rate and no extra payment shall be made to contractor on this account. (ii) The additional copper piping & Gas charging, if required shall be measured and paid separately under respective items of this Schedule.
66M&L for shifting of window type AC of any capacity, any type/make, with stabilizer from one location to another complete with and including making of suitable opening in brick wall or removing aluminium grill and/or glass pane from existing window, including supply and fixing of new wooden frame of suitable size and thickness for proper fixing of outer chassis of AC at new location, making good of disturbed surface to match with the original, including testing & commissioning complete all as specified and as directed. Note: The cost of making suitable opening in brick wall or removing aluminium grill and/or glass pane from existing window and making good of surface at both location as original by plastering / white wash / colour / distemper etc shall deemed to be included in quoted rate and no extra payment shall be made to contractor on this account.
67S&F in replacement of Voltage Stabilizer for automatic operation, single phase, naturally air cooled, indoor type & designed for input variation between 150V - 285 V with output voltage stabilized at 230V with accuracy of + 2.5% and of capacity 4.0 KVA complete all as specified and as directed. Note - Old dismantled voltage stabilizer shall be deposited to MES store yard from existing location. The quoted rate shall includes necessary transportation & Manpower for dismantling and transporting the unit.
68S&F in replacement of Voltage Stabilizer for automatic operation, single phase, naturally air cooled, indoor type & designed for input variation between 150V - 285 V with output voltage stabilized at 230V with accuracy of + 2.5% and of capacity 5.0 KVA complete all as specified and as directed. Note - Old dismantled voltage stabilizer shall be deposited to MES store yard from existing location. The quoted rate shall includes necessary transportation & Manpower for dismantling and transporting the unit.
69Supply only in replacement industrial type metal clad socket only of 20 Amps complete all as specified and as directed.
70Supply only in replacement metal clad top 20 Amp complete all as specified and as directed.
71Supply only in replacement tower AC outdoor unit fan motor for any capacity, Single shaft suitable for existingmake and model complete all as specified and as directed.
72Taking down repairing/rewinding and fixing tower AC ODU fan motor for any capacity of Single shaft suitable for existingmake and model complete all as specified and directed.
73S&F in replacement of indoor unit complete set, suitablefor 1.5 TR split AC of existing make & model, consisting of blower motor, blower, wiring kit complete with display, electronic card with remote assembly, evaporative /cooling coil, remoting system, and plastic housing with bracket frame suitable for Non CFC gases complete all as specified and as directed.
74S&F in replacement of indoor unit complete set, suitablefor 2.0 TR split AC of existing make & model, consisting of blower motor, blower, wiring kit complete with display, electronic card with remote assembly, evaporative /cooling coil, remoting system, and plastic housing with bracket frame suitable for Non CFC gases complete all as specified and as directed.
75S&F in replacement of outdoor unit complete set, suitablefor 1.5 TR split AC of existing make & model, including condenser coil with fins, outdoor fan motor with fan blade, chassis/ cabinet, base plate complete set except compressor complete all as specified & as directed.
76S&F in replacement of outdoor unit complete set, suitablefor 2.0 TR split AC of existing make & model, including condenser coil with fins, outdoor fan motor with fan blade, chassis/ cabinet, base plate complete set except compressor complete all as specified & as directed.
77S&F in replacement of window AC suitable for 1.5 TR Capacity of existing make & model, including condenser and evaporative coil, dual shaft motor with blower and blade, chassis, base plate complete set except compressor complete all as specified & as directed.
78S&F in replacement of window AC suitable for 2.0 TR Capacity of existing make and model, including condenser and evaporative coil, dual shaft motor with blower and blade, chassis, base plate complete set except compressor complete all as specified & as directed.
79S&F in replacement of AC filter of suitable size for window type/ split type AC complete all as specified and directed.
80S&F in replacement of indoor AC unit back plate for split type AC complete all as specified and directed.
81S&F in replacement of indoor AC blower fan bush of suitable size for split type AC of any capacity complete all as specifed and directed.
82M&L in repair sub main wiring with 2 runs of 4.0 Sqmm single core, PVC insulated & unsheathed FRLS cable, 1100 Volts grade, with multi stranded, copper conductor, drawn through and including 25 mm dia, surface, PVC, rigid conduit, medium grade, as per IS, inclusive of boxes (junction/terminal), all tees, bends, elbows, reducers bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook including all fixtures /fittings, fixed on wall/ceiling with saddles PVC and one run of 4.0 Sqmm size PVC insulated FRLS copper conductor complete all as specified and directed. (Note: Two run of 4.0 Sqmm cable and one run of 4.0 Sqmm earth conductor along with 25 mm PVC conduit with accessories shall be measured as one length)
83M&L in repair sub main wiring with 2 runs of 6.0 Sqmm single core, PVC insulated & unsheathed FRLS cable, 1100 Volts grade, with multi stranded, copper conductor, drawn through and including 32 mm dia, surface, PVC, rigid conduit, medium grade, as per IS, inclusive of boxes (junction/terminal), all tees, bends, elbows, reducers bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook including all fixtures /fittings, fixed on wall/ceiling with saddles PVC and one run of 6.0 Sqmm size PVC insulated FRLS copper conductor complete all as specified and directed. (Note: Two run of 6.0 Sqmm cable and one run of 6.0 Sqmm earth conductor along with 25 mm PVC conduit with accessories shall be measured as one length)
84M&L in repair sub main wiring with 4 runs of 10.0 Sqmm single core, PVC insulated & unsheathed (FR) cable, 1100 Volts grade, with multi stranded, copper conductor, drawn through and including 40 mm dia, surface, PVC, rigid conduit, medium grade, as per IS, inclusive of boxes (junction/terminal), all tees, bends, elbows, reducers bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook including all fixtures /fittings, fixed on wall/ceiling with saddles PVC and 1 run of 10.0 Sqmm size PVC insulated copper conductor complete all as specified and directed. (Note: Four run of 10.0 Sqmm cable and one run of 10.0 Sqmm earth conductor along with 40 mm PVC conduit with accessories shall be measured as one length)
85S & F in repair distribution board (DB), double door type, made out of sheet metal enclosure (CRCA sheet), dust and vermin proof, MCB DB, SPN, 8 way, with 200 Amps rated copper bus bar, neutral bar, earth bar, IP 43 protection, 240 Volts, flush to wall complete all as specified and as directed
86S & F in replacement of MCB, SPN, 240 Volts, 32 to 40 Amps, C curve type complete all as specified and as directed.
87S & F in replacement of MCB, SP, 240 Volts, 6 to 40 Amps complete all as specified and as directed.
88S&F in replacement of sheet metal enclosure with socket plug top, single pole and neutral enclosure with a two pin earth plug and socket complete with one MCB of capacity 25 Amps, 240 Volts complete all as specified and as directed.