Tender For Repair To Internal Water Supply, Sanitary Fittings, Tiling And Other Misc B/R Works In Smq Accn In Zone B And Repair To Roof, Rcc Chajja, Tank Staging And Allied Engineering Works In Domestic Area At Akash Vihar And Maru Vihar At Af Stn Su, suratgarh-Rajasthan

Military Engineer Services-MES has published Tender For Repair To Internal Water Supply, Sanitary Fittings, Tiling And Other Misc B/R Works In Smq Accn In Zone B And Repair To Roof, Rcc Chajja, Tank Staging And Allied Engineering Works In Domestic Area At Akash Vihar And Maru Vihar At Af Stn Su. Submission Date for this Tender is 09-10-2023. Plumbing and Sanitary Work Tenders in suratgarh Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

39722951
Corrigendum : Tender For Repair To Internal Water Supply, Sanitary Fittings, Tiling And Other Misc B/R Works In Smq Accn In Zone B And Repair To Roof, Rcc Chajja, Tank Staging And Allied Engineering Works In Domestic Area At Akash Vihar And Maru Vihar At Af Stn Su
Open Tender
Indian
Rajasthan
suratgarh
09-10-2023

Tender Details

Repair To Internal Water Supply, Sanitary Fittings, Tiling And Other Misc B/R Works In Smq Accn In Zone B And Repair To Roof, Rcc Chajja, Tank Staging And Allied Engineering Works In Domestic Area At Akash Vihar And Maru Vihar At Af Stn Suratgarh

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 02-Oct-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 09-10-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 80000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIR TO INTERNAL WATER SUPPLY, SANITARY FITTINGS, TILING AND OTHER MISC B/R WORKS IN SMQ ACCN IN ZONE "B" AND REPAIR TO ROOF, RCC CHAJJA, TANK STAGING AND ALLIED ENGINEERING WORKS IN DOMESTIC AREA AT AKASH VIHAR AND MARU VIHAR AT AF STN SURATGARH
Sl. No. Item Description
1BOQ (REPAIR TO INTERNAL WATER SUPPLY, SANITARY FITTINGS, TILING AND OTHER MISC B/R WORKS IN SMQ ACCN IN ZONE "B" AND REPAIR TO ROOF, RCC CHAJJA, TANK STAGING AND ALLIED ENGINEERING WORKS IN DOMESTIC AREA AT AKASH VIHAR AND MARU VIHAR AT AF STN SURATGARH )
2Taking up or down 15 mm bore steel tubing with connections or fittings from wall, ceiling and floor etc., including cutting/chasing in wall/floor and removal from site, complete all as specified and directed by the Engineer in Charge.
3Taking up or down 20 mm bore steel tubing with connections or fittings from wall, ceiling and floor etc., including cutting/chasing in wall/floor and removal from site, complete all as specified and directed by the Engineer in Charge.
4S&F Steel water tubing, 15 mm bore medium grade, galvanized with all fittings and fixed complete to walls, ceiling or laid in floors, complete all as specified and directed by the Engineer in Charge.
5S&F Steel water tubing, 20 mm bore medium grade, galvanized with all fittings and fixed complete to walls, ceiling or laid in floors, complete all as specified and directed by the Engineer in Charge.
6Re-fixing steel water tubing of 15 mm bore, with all fittings at new or old position, laid in floor along wall or at ceiling, complete all as specified and directed by the Engineer in Charge.
7Re-fixing steel water tubing of 20 mm bore, with all fittings at new or old position, laid in floor along wall or at ceiling, complete all as specified and directed by the Engineer in Charge.
8S&F in repair for gun metal globe or gate valves with iron wheel head , screwed both ends for iron pipe & fixed of size 20 mm bore complete all as specified and directed.
9S&F in repair for gun metal globe or gate valves with iron wheel head , screwed both ends for iron pipe & fixed of size 25 mm bore complete all as specified and directed.
10Cutting holes into or through brick/ stone walls built in cement mortar of superficial area n exc 150 Sq.cm and making good in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified and directed
11Dismantling floors, hearth or wall tilingincluding cement mortar bedding , but not backing removing serviceable tiles to store and rubbish off the premises all as specified and directed .
12M&L for First qualityglazed ceramic colouredtiles of(450x350mm) x 7mm thick, laid on vertical surfaces of wall such as skirting, dados and risers to steps etc laid over and including10mm thick cement plaster in CM (1:4) set and jointed in neat cement paste ofhoney like consistancy and pointed in white or coloured cement to match the shadeof tiles ,complete all as specified and directed by the Engineer in Charge.
13M&L for First quality, Non skid ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 Sq.m but not exceeding 0.11 Sq.m, laid in floors with neat cement slurry @ 3.00 kg/Square Metre over and including 15 mm thick screed bed of cement mortar (1:6) including pointing in white cement with pigment to match the shade of tiles,complete all as specified and directed by the Engineer in charge.
14M&L for First quality, Non skid ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sq.m but not exceeding 0.18 Sq.m, laid in floors with neat cement slurry @ 3.00 kg/Square Metre over and including 15 mm thick screed bed of cement mortar (1:6) including pointing in white cement with pigment to match the shade of tiles,complete all as specified and directed by the Engineer in charge.
15M&L for First quality, Non skid ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sq.m but not exceeding 0.18 Sq.m, laid on vertical surfaces such as skirting, dados and risers to steps etc laid over and including10mm thick cement plaster in CM (1:4) set and jointed in neat cement paste ofhoney like consistancy and pointed in white or coloured cement to match the shadeof tiles ,complete all as specified and directed by the Engineer in Charge.
16Demolition of cement concrete (un-reinforced ) of any description in ground floors and paving not exceeding 15 cm thick (below or above the ground level) complete all as specified and directed.
17M&L 75mm thick cement concrete (1:3:6) Type C2(40 mm stone graded agg) as in plinth protection, finished even and smooth w/o using extra cement complete all as specified and directed .
18Taking down cement plaster of any description including racking out joints, hacking for keys , scrubing down with water etc complete all as specified and directed.
19M&L for Rendering 5 mm thick cement plaster in cement mortar (1:3) on concrete surfaces of roof projection ceilling etc including repairing of borken portion upto 6m height and surface finished even and smoothwithout using extra cement , complete all as specified and directed by the Engineer-in-Charge.
20M&L for Rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 , finished even and smooth without using extra cement, complete all as specified anddirected by Engineer-in-Charge.
21M&L for Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 , finished even and smooth without using extra cement, complete all as specified anddirected by Engineer-in-Charge.
22M&L for Preparation of new plastered or unplastered surfaces of ceiling,chajja etc, and applying three coats of white wash, complete all as specified and directed byEngineer –in-Charge.
23M&L for Preparation of new plastered or unplastered surfaces of wall and applying two coats of oil emulsion distemeper over one coat of primingand including 1-2mm thick JK/Birla wall care putty to achieve smooth finish surface,complete all as specified and directed byEngineer –in-Charge.
24M&L for Preparation of new plastered wall surfaces and applying two coats of exterior acrylic emulsion paint(in camouflage pattern using number of colours) , complete all as specified and directed by the Engineer-in-Charge.
25M&L for preparation of old decoratedsurfacesand applying one coat of oil bound distemper on walls surfaces for smooth finishes, complete all as specified and directed byEngineer –in-Charge. .
26M&L for Preparation of old decorated distempered surfaces of wall and applying two coats of oil emulsion distemeper over one coat of priming and over and including 1-2mm thick JK/Birla wall care putty to achieve smooth finish surface,complete all as specified and directed byEngineer –in-Charge.
27S&F in repair vitreous China wash down water closet pan (Padestal Pattern) white including plastic water closet seat cover as per reqd colour with flat bottom and cover and mild steel chromium plated or alluminium hinging device(excluding flushing cistern) etc complete all as specified and directed by Engr-in-Charge
28S&F in repairVitreous china squatting pan Orissa pattern size 580x440 mm white with integral footrest (exclusive flusing cistern & flush pipe) including cast iron "P" or "S" trap of 100 mm bore pipe fixed in PCC 1:2:4 type B-2and necessary lime concrete,, including making good the surface to match with existing floor finish fixed as in repair,complete all as specified and directed by the Engineer in Charge.
29S&F in repair Wash basins, vitreous china, white, flat back of size 550x400 mm including brackets and cutting for and pinning in ends of brackets or erecting stand 32 mm dia waste fittings, brass, chromium plated with long screwed shanks and fly nuts, 32 mm dia waste pipe and including new brackets , complete all as specified and directed by the Engineer in Charge.
30S&F PVCvalveless , syphonic action dual type flushing cisterns 10 ltrs capacity , low level , white, with inlet ball valves , float and handle including brackets and pvc flush pipe 32 mm dia for low level fixed in repair , complete all as specified and directed by the Engineer in -Charge
31S&F in repairsCP pressure JET for EWC including flexible pipe for 15 mmdia bore,complete all as specified and directed by the Engineer in -Charge
32S&F in repair health faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connection & fixed in position, complete all as specified and directed.
33S&F in repair Stop valve/Angle valve 15 mm dia cast copper alloy , chromium plated fancy type, screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified anddirected by Engineer-in-Charge.
34S&F in repairLong body bib taps,15 mm cast copper alloy,chromium plated ,fancy type ,screwed down , screwed for iron pipe , complete all as specified and directed by the Engineer in Charge.
35S&F in repairs brass Chromium plated 2 in 1 wall mixer for mixing hot and cold water screwed down for iron pipe 15mm bore fancy type etc.complete all as specified and directed. .
36S&F in repairs brass Chromium plated WHB mixer for mixing hot and cold water screwed down for iron pipe15mm bore fancy type etc.complete all as specified and directed. .
37S&F in repairs brass Chromium plated Sink mixer for mixing hot and cold water screwed down for iron pipe and fixed 15mm bore fancy type etc.complete all as specified and directed. .
38S&F Pillar taps, 15 mm borecast copper alloy chromium plated fancy type , with capstan heads, screwed down high pressure, with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe fixed as in repair, complete all as specified and directed by the Engineer in Charge.
39S&F Stainless steel sink with drainage board made of 1.00 mm thick sheet for kitchen or with plugs washers & wastes, including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915 mm x 460 mm with bowl size410mm x 330mm x 160mm, with and including PVC waste pipe and CP waste coupling 32 mm fixed as in repairand making good to disturbed surfaces, complete all as specified and directed by Engineer-in-Charge.
40S&F in repair Chromium plated brass shower rose 125 mm bore of rim with swivel joint, complete all as specified and directed by Engineer-in-Charge
41S&F fixed in repair 100/125 mm dia CP grating with/without hole, complete all as specified and directed by Engr-in-Charge
42S & F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. .
43S&Fin repair 15mm size PVC connection with PTMT nuts 600mm length.complete all as specified and directed.
44S&F in repair CP Tubular towel rail with hook 20 mmdia 600mm long between flanges offixed with and including chromium plated brass screws and wooden/plastic screws. complete all as specified and directed.
45S & F Ball valveof size 15mm dia high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe complete all as specified and directed.
46S & F Ball valveof size 20 mm dia high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe complete all as specified and directed.
47Dismantling existing water storage tanks exc 250 litres but n.exc 500 litres capacity by disconnecting existing water connection and removal from site , complete all as specified and directed by Engineer-in-Charge
48Dismantling existing water storage tanks exc 500 litres but n.exc 1000 litres capacity by disconnecting existing water connection and removal from site , complete all as specified and directed by Engineer-in-Charge
49S & F Rotational moulded PVC, tripple layered, white colour water storage tanks of capacity 500 litre (cylindrical vertical with closed top), ISI Marked, hoisted and fixed in position, with & including all fittings such as GI tank nipple etc.and union ( two nos each) including 20 mm ball valve brass high pressure, complete all as specified and directed by Engineer –in-Charge.
50S & F Rotational moulded PVC, tripple layered, white colour water storage tanks of capacity 1000 litre (cylindrical vertical with closed top), ISI Marked, hoisted and fixed in position, with & including all fittings such as GI tank nipple etc. and union ( two nos each) including 20 mm ball valve brass high pressure, complete all as specified and directed by Engineer –in-Charge.
51Dismantling of cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required up to 100mm internal dia of drains complete all as specified and directed.
52S&F 75mm Sand Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in wall complete all as specified and directed.
53S&F 100mm Sand Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in wall complete all as specified and directed.
54S&F Cast iron floor traps,75mm outlet dia with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed..
55S &F CI Branch pieces, Single (equal or unequal ), ordinary or inverted (spigot or socket type ) or with parallel branches of 100 mm dia complete all as specified and directed..
56S &F Cast iron Single "Y" or cross "T"junctions laid and jointed, in cement mortar 100 mm bore of pipe complete all as specified and directed.
57S & F Cast iron vent cowls 100 mm dia complete all as specified and directed.
58S & F in repair PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls 110 mm dia complete all as specified and directed.
59S&F in repairPVC (SWR)bend for 110 mm dia any radius complete all as specified and directed.
60Taking down Chowkhats with shutters (without taking of shutter from the frame) of any description not exceeding 1.50 Sq. m each, and making good the disturbed Surface in CM1:4 &finish the surface as exists, complete all as specified and as directed by the Engineer-in-Charge.
61S&F Factory made solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplied and fitted as per specification & drawing and as per manufacturer"s instructions,complete all as specified and directed by the Engineer in Charge.
62S&F Factory made solid panel PVC Door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails.MS frame shall be covered with heat moulded plain colour PVC "C" channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail,lock rail and bottom rail on either side as gap insert for top rails, bottom rail,panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, supply & fixing in the frame at site as per specification ,complete all as specified and directed by the Engineer in Charge.
63S&F Aluminium handles ,plate cast type anodised of 150 mm size, complete all as specified and directed by Engineer-in-Charge.
64S&F Aluminum anodizes barrel tower bolts of extruded section and fixed of 200 mm size, complete all as specified and directed by Engineer-in-Charge
65S&F Butt hinges medium weight cold rolled mild steel of 100 mm size and fixed ,complete all as specified and directed by the Engineer in Charge.
66Taking down shutters of any description exceeding 1 Sq. m but not exceeding 2 Sq. m each, complete all as specified and directed.
67S&F of 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels,one face is covered with decorative face veneer with lipping/frame to matchcomplete all as specified and directed.
68S& F in repair Stainless steel chromium plated curtain rail 25mm dia, with & including fixing brackets, knobs and wall side ,stops, rollers etccomplete all as specified and directed by Engineer –in-Charge.
69S&F in repairs Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm longcomplete all as specified and directed by Engineer –in-Charge
70S&F in repairs corner glass shelf assembly consisting of 5.5mm thick sheet glass shelfwith chromium plated bracket guard and railingcomplete all as specified and directed by Engineer –in-Charge
71Demolitionof stoneor brick masonry built in cement mortar including all quoins, arches etc.but excluding ashlar facing, dressed stone work etc, complete all as specified and directed.
72M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m meanradius built in cement mortar 1:6,complete all as specified and directed.
73All as per Srl item No. 71 here-in-before but except bricks.
74M&L for 15mm thick rendering in two layers i.e. 10 mm thick in cement morter 1:6 plus 5 mm thick in cement morter 1:4 mixed with approved water proofing compoundon fair facesofbricksurfacesor concretesurfaces,surfacefinished even and fair without using extra cement allas specified and directed. Note :Water proofing compound shall be measured & paid seprately.
75Material and labourforroughcastplasterwithamixtureconsistingofcrushed stone or fine gravel aggregate of size 6 to 8mm as directed, mixed with coarse sand and cement in the ratio 1:1:1, finshed even over rendering with under coat 15mm thick cement and sand mortar 1:4, complete all as specified and as directed.
76M&L for water proofing layer with Dr. Fixit primeseal on external wall waterproofing as per manufacturer instruction complete all as specified and as directed by Engr-in-Charge.
77M & L for preparation old surfaces of walls and cornices, spoiled by smoke soot, moulds moss and efflorescent salts and trading of oil and greasy sports by scraping with vacuum based sanding machine and washing with water andapplying 1.00-1.5mm wall care putty and rubbing of wall through sand paper to receive smooth finishesand applying one coat of oil bound distempercomplete all as specified and directed.
78Demolition of reinforced cement concrete of any description in any position not otherwise specifically provided for (Reinforcement cut as required to facilitate demolition), complete all as specified and directed.
79M&LforReinforcedcementconcrete,typeA-1(1:1.5:3)nomnal mix,using20mmgradedcrushedstoneaggregateasinslabs supported on walls, beams and columns in floors, roofs, landings, balconies,canopies,deckslabsandinshelvesandthelike, complete all as specifed and directed.
80M&L for RCC chajjas1:2:4 type B0 (using 12.5mm graded stone aggregate) as in approved design complete all as specifed and directed.
81Use and waste ofform work to soffits of suspended slabs such as roof slabs, floor slabs landings and similar work, not exceeding 200mm thick (horizontalorsloping)forroughfinishedsurfacesofconcrete, complete all as specified and directed.
82Use and waste of formwork to cornices and mouldings of any shape in cross section and any girth in fair finishedsurfaces of concrete complete all as specifed and directed.
83Use and waste of formwork to edges of concrete flats, treads breaks in floor, window cills, concrete railing, openings in concrete walls, floor and roofs and similar works exc 5cm but not exc 10cm wide rough finish surface of concrete, complete all as specifed and directed.
84Use and waste of formwork toedge of concrete flats, breaks in floors, opening in concrete walls, floors and roofs and side of RCC/PCC bands in walls and similar works not exc 20cm thick, complete all as specifed and directed.
85S&F for mild steel TMT bars 10mm dia and over , cut to length, bent to shape requred, including crankingbending and binding with mild steel (annealed) wire not less than 0.90mm dia, complete all as specifed and directed.
86S&F for mild steel TMT bars 6mm to 8mmdia , cut to length, bent to shape requred, including crankingbending and binding with mild steel (annealed) wire not less than 0.90mm dia, complete all as specifed and directed.
87Taking downexisting water proofing treatment from the top of RCC/arch slab, including taking down existing PCC padding tiles mud phuskaor plasterand hackingthe topofRCCslab,cleaning with water and disposal of rubbish outside the premises, complete all as specified and directed.
88M&L Cutting out cracks to V-section in existing RCC roof slabs or terracing , cleaning out & filling solidly with a hot mixture of bitumen and clean dry sand 1:1 ( by weight) complete all as specified and directed.
89M&L for PCC (1:2:4), nominal mix, type B-1, (using 20mm graded crushed stone aggregate) as in PCC padding on depression of roof finished even and fair without using extra cement, complete all as specified and directed..
90M&L for 80mm thick average consolidated thickness mud phushka on flat roofs including 25 mm thick mud plaster and 3mm thick leeping plaster complete all as specified and directed.
91M&L for WaterproofingtreatmentwithAPP(Atactic Polypropylene)modifiedPolymericmemberaneoverroof consistingofcleaningofconcreteorplastersurfaceofroofand applying evenly a bitumen primer conforming to IS 3488@ 0.30Kg persqmfollowedbyatackcoat@1.2kgperSqmusing85/25 gradeindustrialhotblown bitumenoveritlaid withAPP modified polymericwaterproofingmembraneminimumweight3.6kgper Sqmreinforcedwithnon-wovenpolyesterfabric(weightnotless than 160 gm persqm) unrolled& bondedto substratewith longitudinal and end laps 100mm as per manufacturer"s instruction andapplyingoveritatackcoatusing85/25gradeindustrialhot blown bitumen @ 1.2 kg sqm andas per manufacturer instruction and including taking the APP membrane will be required where the parapet wall exceed 45cm for carrying over and taking into parapet walls,cutoutneatlyahorizontalgroove6.5cmdeep,7.5cm widesectionwithloweredgeatnotlessthan15cmabovethe gradedroofsurfaceandgrooveshallbefinishedsmoothwith cement mortar 1:4 with WPC @3% by weight of cement where the parapet wall height is 45cm or less no groove will be required as the water proofing treatment will be carried over the top of parapet wall to its full thickness, complete all as specified and directed.
92M&L for 15 mmthickrenderingin cement mortar1:4on roofsurfaceusingwaterproofingcompundaspermanufacturer instructionsurfaces finished even and smoothwithoutusing extra cement asonwallcomplete all as specified and directed.
93M&L for 40 mm thick brick tiles laid on above treated surface and joints grounted flush in cement mortar 1:3 mixed with 5% crude oil by weight of cement on above treated surface all as specified.
94All as per above item here-in-before 92 but except brick tiles complete all as specified and directed.
95M&L for PCC M-15 (nominal mix), type B-0 (using 12.5mm graded crushed stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges, complete all as specified & directed.
96Supply only integral water proofing compound(ISI marked), complete all as specified and directed.
97M&Lfor repairing of RCC projections, chajjas , roofs, facia etc. by necessary preparation i.e. scrapping, cutting, chiseling, derusting and cleaning exposed reinforcement, sufaces of damaged, loose RCC surfaces and applying one coat of cement slurry and filling the surfaces with cement concrete (1:1.5:3) using 12.5mm graded crushed stone aggregate and reinforced withwelded mesh of weightexc 2kg per sq mtrbut n.exc 3kg/sqm with or without facia and finished with cement sand mortar (1:3) using coarse sand in patches are n.exc 70mm including applying two coats of finishes to match with the existing surfaces in at any height complete all as specified. Note:- Cost of formwork and welded mesh shall be deemed to be included in unit rate quoted by the contractor.
98S&F in repairs PVC (SWR) pipes, 110mm dia, single socketed, in anylengthwithrubberringjoints,laidintrenchesorinfloors,Wallscomplete all as specified & directed.
99M & L for Guniting work to RCC work in columns , beams , chajjas, balconies , slabs , landings and roof projection etc by removing loose concrete, cleaning of surfaces with brush and applying one coat of epoxy paint SIKA/fosrocto rusted reinforcement including welded wire mesh fabric of wire not less than 95mm X 95mm X 3mm , adhesive plaster grade for concrete admixture non providing guniting pressure 2.00/2.50 Kgs/sqm with admixture , 1part of cement and 3.25 part of sand with a thickness of 50mm averaging and making the surfaces even and smooth including all necessary form work /scaff folding and applying 5mm thick cement plaster in CM(1:3) complete all as specified and directed by Engr-in-charge.
100Dismantling structural steel work including doors, gatesand plate but excluding framed truss etccomplete all as specified and directed.
101S&F for mild steel work in tubular trussesincluding special shaped washersetc, complete using but ERW or induction butt welded tubes confirming to IS 1161- 1979 graded St 240 withone shop coat of zinc chromate primer paint, complete all as specified and directed.
102S&F for rolled mild steel plates (plain or chequered) channels, square cut or notched, forming holes, with riveted, bolted or welded attachment confirming to Fe 410 - W, complete all as specified and directed.
103S&F for mild steel forframed structure liketrussed, purlins, crane gantries,postrails and fastenings and heavy bracket framming (Beam,Tee, Angle, Channels, flat sections) including distance pieces, cleats etc conforming to Fe410-W (Gde-E-250) quality-A, complete all as specified and directed.
104Dismantling of asbestos cement (Corrugated, semicorrugated etc) sheets in roof coverings complete all as specified and directed.
105M&L for 6mm thick asbestos cement sheet, corrugated, or semi corrugated sheets in roofs, walls etc. and fixed with L hook or Cranked bolts, complete all as specified and directed.
106Ditto but all as per item No 104 but except sheet.
107S&F for Asbestos cement two adjustable plain wing ridge 6mm thick serrated ridge for corrugated or semi corrugated sheet Fixed with L-type or J-type or cranked hook bolts complete all as specified and directed.
108S&F for Roof tiles, Mangalore pattern, interlocking at side joints, laid drycomplete all as specified and directed.
109M&L for pre-painted galvanlume aluminium zinc coating havingGI based corrugated steel sheets 0.50mm thick of any colour and shape of sheet approved by GE as in tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screw complete all as specified and directed. Note: shape of sheet approved by GE
110S&F for mild steel screws bolt (Machine made) with hexagonal or square heads one end screwed , each screwed end have one washer and one nut, dia of shank 11mm-15mm and length of bolt exc 5cm and not exc 10cm, complete all as specified and directed.
111S&F for mild steel flat iron as wind tie for roof including necessary drilling for securing bolts etc, complete all as specified and directed.
112M&L for Providing and injecting chemical emulsion for glyphosate-based herbicides above external roof surface, roof kerbs , roof parapets , khuras and like using chemical emulsion at the rate of .5 litres per 10sqm of the vertical/horizontal surface including making good surface using cement mortar 1:2 (1 cement :2 coarse sand) to match the existing surface/sub surface complete all as specified and directed.
113Scrub/bush including grasses, herbs and geophytes to grubbing up including cutting of trunk portion protruding over roof, digging out roots, filling holes with cement mortar 1:2 and levelling off surface , stacking of serviceable material and removing of unserviceable material to a distance not exc. 1km and clearing sit complete all as specified and directed.
114M & L providing 35 mm thick pre-cast cement concrete 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in louvers & jallies (measured solid) including all mouldings and including pre-cast frames set in cement mortar 1:4 complete all as specified and as directed.
115M & L providingprecast concrete 1:2 :4 type B-1 using 20 mm graded stone aggregateas in RCC jali postsetting in mortar1:6 complete all as specified and directed.
116M&L for 15-20mm thick Leeri of Jodhpur sand stone with rock face bushing fixed in CM 1:3 complete all as specified and directed.
117M&L for sand stonemoulded weathered copings , window cills & the likes set in CM 1:6 with corbelling , throatings all as per design complete all as specified and directed.
118Cleaning and removing all scales and dirt etc from tanks and from mouths of circulating pipe etc for capacity exc 250 & n.exc 500 ltrs capacity of tanks as directed by Eningeer -in-Charge. (Note: Date of cleaning to be written on the tank after cleaning)
119Cleaning and removing all scales and dirt etc from tanks and from mouths of circulating pipe etc for capacity exc 500 & n.exc 1000 ltrs capacity of tanks as directed by Eningeer -in-Charge. (Note: Date of cleaning to be written on the tank after cleaning)
120Supply and fixing 2mm thick fibre glass reinforced translucent corrugated sheetingwithtwocorrugationsidelapfixedwithcoach screwsandwasherinroof,wall,chajjaetc.,complete all as specified and as directed.
121Dismantling of wall and ceiling or insulation boards/ slabs / PVC panelling any thickness and in any position incl frame grid and cover fillets and framework etc complete all as specified and as directed.
122Material and labour for providing and fixing false ceiling of 15mm thick fine fissure board sharped finished mineral fiber accoustic false ceiling tiles with back of the duly sanded and finished with a coat of protective paint and front duly finished of false system of size (600x600)mm having noise reduction co-efficient of 0.55 light reflection of 80% thermal conductivity k=0.057 W/WWC and humidity resistance of 95% fixed to true look PVC die KL-24 suspension system (hot dipped galvanised steel section) of exposed T Section grid with exposed face powder coated white colour.The suspension system consisting of panelling grid shall be following min sizes:main T section(24X38X0.3mm 3m long), Cross T section (24X25X0.3mm 6m long), wall angle (24X24X0.3mm 3m long),hanger rod 4 mmAdjust clip (85X30X0.8mm), soffit cleat (27X37X25X1.6mm), Dash fastener (12.5 mm dia) with complete all as specified and as directed.
123all as per item No 121 Except Board
124Material and labour for GI metal false ceiling lay in plain regular edge white color tiles of size 595X595X0.5mm thick with 8mm drop made of GI sheet having galvanizing of min 120 gms/sqm (both side inclusive ) & electro statically polyester powder coated of thickness 60 microns(min) including factory painted after bending ceiling grid shall be following min sizes:main T section(24X38X0.3mm 3m long), Cross T section (24X25X0.3mm 6m long), wall angle (24X24X0.3mm 3m long),hanger rod 4 mmAdjust clip (85X30X0.8mm), soffit cleat (27X37X25X1.6mm) , Dash fastener (12.5 mm dia) with complete all as specified and as directed.
125S&F for 8mm thick hollow printed coloured PVC sheet wall lining/panelling including frame work (sample kept in GE office) made of 1mm thick PVC sheet in strips and channels feathered at the edges for fixing of wall lining inclusive of solvent cement and fixing at site , complete all as specified and directed by the Engineer-in-Charge.
126Contract Amount shall be derived after deducting the amount of Schedule of Credit in General Summary on serial page No 17 of tender documents.