Uttar Pradesh Power Transmission Corporation Limited-UPPTCL has published Tender For Work For Replacement Of 132Kv Control Relay Panel, Maintenance Of 132 Kv Cb And Replacement Of 33 Kv Bus Pt At 132 Kv S/S Banda Under Etd, Banda. Submission Date for this Tender is 29-09-2023. Control Relays Tenders in banda Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Details of Work. |
2 | Dismantaling of Old control relay Panel of 132KV Banda -Banda Line by removing all cable connection wiring. |
3 | Erection of New Control relay panel and connection of all control cablewiring connection as per drawing |
4 | cable laying4Cx2.5 Sq.mm |
5 | cable laying 6Cx2.5 Sq.mm |
6 | Dismantaling of old damaged 33KV 3 Phase BusPT by removing all wiring cnnectionat 132KV Banda. |
7 | Dismantaling of New33KV 3 Phase PT from 10MVAR capacitor bank bay at 132KV S/S Pailani |
8 | Carriage of New33KV 3 Phase PT from 132KV S/S Pailani to 132KV S/S Banda including loading &unloading etc |
9 | Erection of New 33KV 3 Phase PT for 33KV Busat 132KV Banda |
10 | Repairing and Overhauling & Servicingof 145KV Circuit Breakerat 132 KV S/S Banda. Work consist of : (a) Complete dismantling of 01 No. pole mechanism assemby, main spring, ratchet gear and other connected part. Necessary repairing/rectification of defective part. (b) Replacement of all damaged and defective parts closing latch assembly, trip latch, close coil etc and its proper adjustment. Cleaning & greasing. (c)CheckGas pressure switch with proper adjustment and calibartion (d)Dismentling of all pole linkage, pins and rod assembly, cleaning, greasing and its proper adjustment.(e)Check statisfactory close/trip operation of the breaker both by local remote . (f)Check close/trip timing by digital timer |
11 | Repairing and Overhauling & Servicingof 33 KV VCB at 132 KV substation Banda.Work consist of : (a) Checking & Adjustment of Snatch gap travel of drive Insulators rod and tie rod of each Pole.(b) Replacement of all damaged and defective parts closing latch assembly, trip latch, close coil etc and its proper adjustment. Cleaning & greasing. (c)Oiling and Greasing of CRANK gear by openng of lock, circlip etc.(d)Dismentling of all pole linkage, pins and rod assembly, cleaning, greasing and its proper adjustment.(e)Check statisfactory close/trip operation of the breaker both by local remote . (f)Check close/trip timing by digital timer (g) Repairing of mechanism for solving the mechnical problem..After Overhauling of VCB following test to be carried out. (i) Opening & Closing time of breaker of each Pole (ii)carring of contact resistance measurement of each Pole.(iii) Checking of Megger value of breaker Pole. |
12 | Rates qouted by the bidders shall be without taxes. Taxes applicable if any to paid extra |