}

Tender For The Erection Work Of 11 Kv Lines Due To Bifercation Of Various 11 Kv Feeders And Increasing Capacity Of Power Transformer From 8 Mva To 10 Mva Under Business Plan 2023-24 Under Eudd, Banda, banda-Uttar Pradesh

Dakshinanchal Vidyut Vitran Nigam Limited has published Tender For The Erection Work Of 11 Kv Lines Due To Bifercation Of Various 11 Kv Feeders And Increasing Capacity Of Power Transformer From 8 Mva To 10 Mva Under Business Plan 2023-24 Under Eudd, Banda. Submission Date for this Tender is 28-10-2023. Electrification Work Tenders in banda Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

39719224
Corrigendum : Tender For The Erection Work Of 11 Kv Lines Due To Bifercation Of Various 11 Kv Feeders And Increasing Capacity Of Power Transformer From 8 Mva To 10 Mva Under Business Plan 2023-24 Under Eudd, Banda
Open Tender
Indian
Uttar Pradesh
Banda
28-10-2023

Tender Details

The Erection Work Of 11 Kv Lines Due To Bifercation Of Various 11 Kv Feeders And Increasing Capacity Of Power Transformer From 8 Mva To 10 Mva Under Business Plan 2023-24 Under Eudd, Banda- 1 The Following Works Under Various Places / Sub-Stations Under Business Plan Scheme 2023-24 Under Edd, Atarra, Including Carriage Of All Required Material From Esc Banda To Work Site, Alongwith Its Loading, Unloading & Dragging At The Respective Ends And Also Safe Carriage Of Old Line Material / Scraped From Site To Store Centre, If Any. Some Petty Material Like All Types Clamps, Cable Boxes, Aluminium Tape, Lugs, Hoisting Clamp / Cable Hanging U Clamps, Danger Board, Number Plate, Angle, Hdpe / Gi Pipes, Nut-Bolts & Washers Etc. Of Appropriate Size & All Plinth / Fencing Materials Will Be Arranged By Contractor On His Own Cost. The Bidder Shall Be Responsible For Complete Execution Of The Work Under The Scope Of Tender Specification. Any Work / Activity Not Specifically Indicated But Is Required For Systematic Execution Of Job Shall Be Carried Out By The Contractor Without Any Extra Payment. Details Of The Work As Given Below ;- 2 Erection Of 11 Kv Ht Lines -Due To Bifercation Of 11 Kv Baberu & Singhpur Feeder 3 Safe Cartage Of 11 Mtr. Long Stp Poles From Store Centre Or From Any Other Place To The Respective Site Of Work. 4 Safe Cartage Of 8.5 Mtr. Long Pcc Poles From Store Centre Or From Any Other Place To The Respective Site Of Work. 5 Safe Cartage Of Line Material Viz. Conductor, Cable, G.I. Earth Wire, Cross Arm, Angle, Channel, Insulator, Clamps And Other Line Material From Store Centre Or From Any Other Place To The Respective Site Of Work. 6 Erection Of Sp Structure On 11 Mtr. Long St Poles, Including Complete H.T. / L.T. Fittings As Per Resspo Manual And As Per Direction Of Engineer Incharge. 7 Erection Of Dp Structure On 11 Mtr. Long St Poles, Including Complete H.T. / L.T. Fittings As Per Resspo Manual And As Per Direction Of Engineer Incharge. 8 Erection Of Sp Structure On 8.5 Mtr. Long Pcc Poles, Including Complete H.T. / L.T. Fittings As Per Resspo Manual And As Per Direction Of Engineer Incharge. 9 Grouting Of Sp Structure On 8.5 / 11 Mtr. Long Pcc / St Poles, Including Complete H.T. / L.T. Fittings As Per Resspo Manual And As Per Direction Of Engineer Incharge. The Support Shall Be Grouted With Cement, Sand And Brick Ballast / Stone Ballast In Ratio 1:4:8 ( 0.285 Cu. Mtr. Each ) . 10 Grouting Of Dp Structure On 11 Mtr. Long St Poles, Including Complete H.T. / L.T. Fittings As Per Resspo Manual And As Per Direction Of Engineer Incharge. The Support Shall Be Grouted With Cement, Sand And Brick Ballast / Stone Ballast In Ratio 1:4:8 ( 0.285 Cu. Mtr. Each ) . 11 Erection And Grouting Of Stay Set With Nozelling & Binding As Per Norms. 12 Fixing Of Earthing Rod As Per Resspo Manual. 13 Laying, Sagging, Stringing, Binding And Jumpering Etc. Of Acsr Weasel Conductor On The Newly Erected Pole As Per Direction Of Supervising Engineer / Resspo Manual. 14 Laying, Sagging, Stringing, Binding And Jumpering Etc. Of Acsr Dog Conductor On The Newly Erected Pole As Per Direction Of Supervising Engineer / Resspo Manual. 15 Laying, Stringing, Binding And Termination Etc. Of Xlpe Cable 11 Kv 3X185 Sq.Mm. On The Erected Line As Per Direction Of Supervising Engineer / Resspo Manual. 16 Supply & Fixing Of M.S. T-Off Channel With Clamp & N&B Alongwith Fitting Of All Accessories As Per Resspo Manual ( Arranged By Contractor At His Own Cost ) . 17 Supply & Fixing Of 11 Kv Cross Arm Holding Clamp With N&B Alongwith Fitting Of All Accessories As Per Resspo Manual ( Arranged By Contractor At His Own Cost ) . 18 Supply & Fixing Of 11 Kv 3X185 Sq.Mm. Cable Jointing Kit I / D With Fitting Of All Accessories As Per Resspo Manual ( Arranged By Contractor At His Own Cost ) . 19 Supply & Fixing Of 11 Kv 3X185 Sq.Mm. Cable Jointing Kit O / D With Fitting Of All Accessories As Per Resspo Manual ( Arranged By Contractor At His Own Cost ) . 20 Supply & Fixing Of M.S. Bracing Angle With 4 Clamps & Nut-Bolts Alongwith Fitting Of All Accessories As Per Resspo Manual ( Arranged By Contractor At His Own Cost ) . 21 Supply & Fixing Of Clamp For Channels With N&B Alongwith Fitting Of All Accessories As Per Resspo Manual ( Arranged By Contractor At His Own Cost ) . 22 Supply & Fixing Of F-Clamp With N&B Alongwith Fitting Of All Accessories As Per Resspo Manual ( Arranged By Contractor At His Own Cost ) . 23 Supply & Fixing Of Danger Board With Clamp & N&B Alongwith Fitting Of All Accessories As Per Resspo Manual ( Arranged By Contractor At His Own Cost ) . 24 Supply & Fixing Of Guarding Angle With Clamps & Nut-Bolts Alongwith Fitting Of All Accessories As Per Resspo Manual ( Arranged By Contractor At His Own Cost ) . 25 Increasing Capacity Of Power Transformer From 5 Mva To 10 Mva -33 / 11 Kv Sub-Station, Badausa & Bisanda 26 Safe Removal Of Following Capacity Old Transformer From Existing Plinth As New Transformer Will Be Replaced By Store And After Installation Reconnecting Transformer To Circuit - 27 5 Mva Transformer 28 Supply & Fixing Of 11 Kv Indoor Type Cable Jointing Kit Of Size 3X300 Sq.Mm. With Fitting Of All Accessories As Per Resspo Manual ( Arranged By Tenderer At His Own Cost ) . 29 Supply & Fixing Of 11 Kv Outdoor Type Cable Jointing Kit Of Size 3X300 Sq.Mm. With Fitting Of All Accessories As Per Resspo Manual ( Arranged By Tenderer At His Own Cost ) . 30 Repairing Cable Trench From Switchgear To Transformer And Upto 33 Kv Breacker And Laying Of 11 Kv Xlpe Cable 3X300 Sq.Mm.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 04-10-2023 Date Extention Corrigendum5 Date 09-10-2023
2 09-10-2023 Date Extension Corr. Date 14-10-2023
3 14-10-2023 Date Extension Corr.2 Date 18-10-2023
4 18-10-2023 Date Extension Corr.3 Date 21-10-2023
5 21-10-2023 Date Exten Corrigendum Date 25-10-2023
6 23-09-2023 Date Extention Corrigendum3 Date 29-09-2023
7 25-10-2023 Date Exten Corrigendum1 Date 28-10-2023
8 29-09-2023 Date Extention Corrigendum4 Date 04-10-2023

Key Value

Document Fees
INR 1180 /-
EMD
INR 8500.0 /-
Tender Value
INR 8.30 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail