Tender For Supply Of Material And Works Against System Strengthening Works In Muncipal Area On Semi Turn Key Basis In Eudd-Mayohall, Bamrauli And Tagore Town Under Eudc-Ii, Prayagraj., prayagraj-Uttar Pradesh

Purvanchal Vidyut Vitaran Nigam Limited has published Tender For Supply Of Material And Works Against System Strengthening Works In Muncipal Area On Semi Turn Key Basis In Eudd-Mayohall, Bamrauli And Tagore Town Under Eudc-Ii, Prayagraj.. Submission Date for this Tender is 25-09-2023. Cleaning Rags and Cloths Tenders in prayagraj Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

39712522
Tender For Supply Of Material And Works Against System Strengthening Works In Muncipal Area On Semi Turn Key Basis In Eudd-Mayohall, Bamrauli And Tagore Town Under Eudc-Ii, Prayagraj.
Open Tender
Indian
Uttar Pradesh
prayagraj
25-09-2023

Tender Details

Supply Of Material And Works Against System Strengthening Works In Muncipal Area On Semi Turn Key Basis In Eudd-Mayohall, Bamrauli And Tagore Town Under Eudc-Ii, Prayagraj.- 1 SUPPLY OF MATERIALS (Part-A) 2 Trip Coil OCB/VCB 24 V 3 Multi Meter (100 Amp & 750V) 4 Digital Earth Tester 5 Volt Meter 6 Clamp Meter 7 Relly for 11 KV Pannel 8 PLA Relly 24 V DC/240 V AC 9 Closing Coil 24 V 10 Breather 11 WTI 12 OTI 13 Remote Switch 14 Amp Meter 15 LED Indicator Bulb 16 33 KV Braker Moter 17 33 KV Really ABB Make 18 11 KV SLR 140 C Really 19 11 KV Pannel Charging Motar 20 11 KV Really P 122 micon 21 11 KV Really P 127 micon 22 33 KV REF 615 Really 23 Busbar Spout (test) 24 T/f Bushing HV/LV (Test) 25 Structure for 33 KV VCB (Test) 26 Structure for CT(Test) 27 Structure for Linghting Arrester(Test) 28 Control Cable 4x2.5 sqmm sizes (test) 29 Control Cable 6x2.5 sqmm sizes (Test) 30 Control Cable 4x1.5 sqmm sizes (Test) 31 Holding Clamp for ST Pole-Cross Arm 32 Holding Clamp for Top Chanel (STP/PCC) 33 Suspension Clamp for ABC Cable 34 Dead End Clamp for ABC Cable 35 Stone Pad (300x300x75 MM) 36 Danger Board with clamp for 11KV & 33 KV 37 GI Barbed wire 38 Aluminium Binding wire 6 SWG 39 Aluminium Paint 40 Chemical Earthing Complete 41 Red Oxide Paint 42 Bolts, Nut & Washer All size 43 Aluminium Crimping Lug 70sqmm 44 Aluminium Crimping Lug 240 sqmm 45 Aluminium Crimping Lug 400 sqmm 46 LT Shackle Insulator 47 Copper Z Clamp 48 I- Hook 49 PRC 120 Sqmm 50 PRC 90 Sqmm 51 DD Wire PVC 70 Sqmm 52 LT Cubical Box For Tailness Unit 53 Tailness Unit 500 Amp 54 Copper Strip 50x6sqmm 55 GI Strip 50x6 56 Service Clamp for ST Pole 57 PVC Cable 1x35 Sqmm 58 MS Angle 50x50x6 MM 18 59 U-Bolt with Nuts 60 MOUNTING, FITTING & ERECTION OF WORK AS PER RESPO NORM. (Part-B) 61 Eerection, grouting, plinthing & painting of 11 mtr single supportwith disconnent from old pole,tapping on new pole of 11 KV line ,1 no v cross armincluding fixing of necessary clamps, other accessories likeguarding angle ,disc insulator with fitting, pin insulator, L.T arm, shackle insulatoretc. grouting ratio 1:4:8, cement, stone grit & coarse sand, plinthing of support of size 0.4x0.45x0.3 Mtr.with cement sand& bricks blast in ratio 1:4:8 and 12 mm thick plastring around the plingth in ration 1:2:4 with 12 mm thickness curing of plingth should be done properly (Grouting , plinthing and all required material will be arranged by the contractor as per Resspo and Electrical Safety rule,only S.T.Pole provided by Deptt.) 62 Fixing & grouting of stay rod with cement, sand and bricks ballast in ratio !:4:8 and fasteniong the stay wire with pole and stay rod nozzling.(Grouting material will be arranged by the contractorasper Resspo and Electrical safety rules.) 63 Earthing of support complete with the help of M.S. rod 16 mm dia and 2.5 mtr. long, fastening of G.I. wire with clamps/X-arm/support to M.S. earth rodas per Resspo and Electrical Safety rule 64 Spreading and stringing of 1 stay wire continuous conductor for hanging 11 KV cable including binding of insulator complete in all respect. The work includes jumpering/connecting of conductor at sectional poleas per Resspo and Electrical Safety rule 65 Laying of single 11 KV, 3x185 sq mm XLPE cable Hanging with the help of stay wire/normal soil by digging of trench 900 mm deep, 600 mm wide including supply of required material like first class brick, stone pad and sand etc. The enter axial spacing between two cable( in case of any other cable is also running in parallel) should be in between o.25 mtr. to .40 mtr. The cable shall be laid between two continous rows of bricks, river sand packing on all side of cable shall be done. After laying down of the cable the stone slab shall be laid in such a manner so that cable channel is completely covered from top. The cable shall be laid strictly in compliance to RESSPO Norms and Electrical safety rules (All material required for laying will be supplied by the contractor. 11 KV cable provided by Deptt.) 66 Laying of single 11 KV, 3x120 sq mm XLPE cable Hanging with the help of stay wire/normal soil by digging of trench 900 mm deep, 600 mm wide including supply of required material like first class brick, stone pad and sand etc. The enter axial spacing between two cable( in case of any other cable is also running in parallel) should be in between o.25 mtr. to .40 mtr. The cable shall be laid between two continous rows of bricks, river sand packing on all side of cable shall be done. After laying down of the cable the stone slab shall be laid in such a manner so that cable channel is completely covered from top. The cable shall be laid strictly in compliance to RESSPO Norms and Electrical safety rules (All material required for laying will be supplied by the contractor. 11 KV cable provided by Deptt.) 67 Fixing ofHeat Shrink cable type end Terminations suitable for 11 KV, 3x185/3x120 sq mm XLPE cable and 11 KV 3x185/3x120 sq mmasper Resspo and Electrical safety rules. 68 Outdoor/indoor jointing kit 69 Straight through jointing kit 70 Erection & commissioning of 11 KV VCB incoming in the switch gear room, by grouting base channel 100 x 50 x 6 x 1000mm. Fixing of 11 KV switchgears rag bolt with proper connection & earthing with GI Strip 50x6mm , control cable & Earthing Materials provided by contractor. 11 KV VCB provided by Deptt. 71 Erection & commissioning of 11 KV VCBoutgoing in the switch gear room, by grouting base channel 100 x 50 x 6 x 1000mm. Fixing of 11 KV switchgears rag bolt with proper connection, & earthing with GI Strip 50x6mm , control cable & Earthing Materialsby contractor. 11 KV VCB provided by Deptt. 72 Erection, grouting, plinthing, earthing & painting of 11 mtr long sub station type D/P formounting of T/Fs with all accessories like 11 kv fuse set, TPMO, top channel, grouting in ratio1:4:8, cement, stone grit & coarse sand, plinthing of support of size 0.4x0.45x0.3 Mtr.with cement sand& bricks blast in ratio 1:4:8 and 12 mm thick plastring around the plingth in ration 1:2:4 with 12 mm thickness curing of plingth should be done properly as per Resspo and Electrical Safety rule 73 Fixing & grouting of stay rod with cement, sand and bricks ballast in ratio !:4:8 and fasteniong the stay wire with pole and stay rod nozzling.(Grouting material will be arranged by the contractorasper Resspo and Electrical safety rules.) 74 Earthing of support complete with the help of M.S. rod 16 mm dia and 2.5 mtr. long, fastening of G.I. wire with clamps/X-arm/ support to M.S. earth rodas per Resspo and Electrical Safety rule 75 Construction of 11/0.4 KV Transformer plinth in size 1.5x1.5x 1.8 mtr. Height, including 0.6 mtr. below G.l. in bottom 1:4:8 cement sand and brick ballast; concreting upto 15 cm. thickness after ramming should be done. Thickness of 1st class brick work should be 0.35 mtr. below G.L. and above G.L. It should be 0.23 mtr. brick work bill be done with 1:4 cement, sand mortar, The space between the four walls should be filled with sand by ramming and watering keeping a space of 0.15 mtr on lop for 1:2:4 cement stone ballast and sand concreting. The two channels should be grouted as per direction of site in charge. All the sides of wall above G, L. should be plastered by 1:6 cement sand mortar having 12 mm thickness. 76 Providing and fixing of welded wire mesh fencing, around transformer plinth having one locking arrangements, Fencing should be provided by grouting MS angle 40x40x5 mm. length of 1.5 m. on all the sides as per standard practice and design. The painting of fencing should be done by good quality green paint with two coats after rubbing and cleaning and providing one coat red oxide primer. The fencing should be 2 M. above ground level. The rates should be inclusive of all materials required for completion of above work. (Plinthing and all required material will be arranged by the contractor per Resspo and Electrical Safety rule) 77 Erection & commissioningof T/F 250 KVA on plinth. along with HT/LT connections with copper L-piece. Complete in all respect,as per Resspo and Electrical Safety rule 78 Earthing of transformer body and neutral by lowering of chemical pipe/Rod (earthing)connecting with GI Strip of size 50x6 mm with clamps, as per Resspo and Electrical Safety rule 79 Spreading and stringing of 1 stay wire continuous conductor for hanging 11 KV cable including binding of insulator complete in all respect. The work includes jumpering/connecting of conductor at sectional poleas per Resspo and Electrical Safety rule 80 Laying of single 11 KV, 3x70 sq mm XLPE cable by Hanging with the help of stay wireThe cable shall be laid strictly in compliance to RESSPO Norms and Electrical safety rules (All material required for laying will be supplied by the contractor. 11 KV cable provided by Deptt.) 81 Fixing ofHeat Shrink cable type end Terminations suitable for 11 KV, 3x70 sq mm XLPE cable and 11 KV 3x70 sq mmasper Resspo and Electrical safety rules. Outdoor jointing kit 82 Laying of single 11 KV, 1x70 sq mm XLPE cable Hanging from HT line to T/F HT bhushing including Tapping from HT Line,crimping lug both sides and all Related HT,LT connection etc (All material required for laying will be supplied by the contractor. 11 KV cable provided by Deptt.) 83 Erection and grouting of LT Cubical Box, Making platform for stepping, plastering the same with cement sand in raio 1:6 Fising the tailless unit 500 Amp making LT Bus Bar and its taping. 84 Errection andFixing the tailless unit 500 Amp in existing LT cubical Box/Double pole making Copper LT Bus Bar and its taping. 85 Laying/hanging of following LT cable of different sizes for main/distribution/connecting the main cable from T/F to tailless unit and for distribution, from tailless unit to LT section Pole, crimping the both ends of cable if required and tapping be made inside distribution box making channel of first class brick and filling with soil. 86 1x400 sq. mm. 87 3 ½x240 sq. mm. 88 Errection & Commissioning of (3x120+1x195+1x16) sq.mm ABC,necessary clamps, I-Hook, dead end clamp, suspension clamp,pierising connecter 1x35 sq.mm. & 1x16 sq.mm. PVC cable as per RESSPO norms will be arranged by the contractor exept AB cable as per Resspo and Electrical Safety rule 89 Errection & Commissioning of distribution boxes/kiosk on the LT poles including all clamps & materials required, connections & sealing its connection in between Distribution Box & ABC 1x35 sq. mm LT PVC cable (all required Local materialsarranged by the contractor as per Resspo and Electrical Safety rule) 90 Construction of 11/0.4 KV Transformer plinth in size 1.5x1.5x 1.8 mtr. Height, including 0.6 mtr. below G.l. in bottom 1:4:8 cement sand and brick ballast; concreting upto 15 cm. thickness after ramming should be done. Thickness of 1st class brick work should be 0.35 mtr. below G.L. and above G.L. It should be 0.23 mtr. brick work bill be done with 1:4 cement, sand mortar, The space between the four walls should be filled with sand by ramming and watering keeping a space of 0.15 mtr on lop for 1:2:4 cement stone ballast and sand concreting. The two channels should be grouted as per direction of site in charge. All the sides of wall above G, L. should be plastered by 1:6 cement sand mortar having 12 mm thickness. 91 Erection & commissioningof T/F 400 KVA on New/Existing plinth. along with HT/LT connections with copper L-piece. Complete in all respect,as per Resspo and Electrical Safety rule 92 Earthing of transformer body and neutral by lowering of chemical pipe/Rod (earthing)connecting with GI Strip of size 50x6 mm with clamps, as per Resspo and Electrical Safety rule 93 Erection and grouting of LT Cubical Box, Making platform for stepping, plastering the same with cement sand in raio 1:6 Fising the tailless nit 500/300 Amp making LT Bus Bar and its taping. 94 Errection andFixing the 500 Amp. tailless unit in existing LT cubical Box/Double pole making LT Bus Bar and its taping. 95 Laying/hanging of following LT cable of different sizes for main/distribution/connecting the main cable from T/F to tailless unit and for distribution, from tailless unit to LT section Pole, crimping the both ends of cable if required and tapping be made inside distribution box making channel of first class brick and filling with soil. 96 1x400 sq. mm. 97 3 ½ x240 sq. mm. 98 Errection & Commissioning of (3x120+1x195+1x16)/ (3x95+1x70+1x16) sq.mm ABC,necessary clamps, I-Hook, dead end clamp, suspension clamp,pierising connecter 1x35 sq.mm. & 1x16 sq.mm. PVC cable as per RESSPO norms will be arranged by the contractor exept AB cable as per Resspo and Electrical Safety rule 99 Errection & Commissioning of distribution boxes/kiosk on the LT poles including all clamps & materials required, connections & sealing its connection in between Distribution Box & ABC 1x35 sq. mm LT PVC cable (all required Local materialsarranged by the contractor as per Resspo and Electrical Safety rule) 100 Dismantling of all the HT/LT line, connections & earthing of old 11/.4 kV, 250 KVA transformer along with LT cubical box, cable GO set, DO set & T/F, safe loading carrage and unloading of dismentled item from site of work to center store Naini/Power House store/New site. 101 Erection, grouting, plinthing,& painting of single support pole 9 mtr long STPfor LT line, including fixing of necessary clamps grouting in ratio1:4:8, cement, stone grit & coarse sand,plinthing of support of size 0.4x0.45x0.3 Mtr.with cement sand& bricks blast in ratio 1:4:8 and 12 mm thick plastring around the plingth in ratio 1:2:4 with 12 mm thickness curing of plingth should be done properly (Grouting & plinthing related all required material will be arranged by the contractor except 9 mtr long STPas per Resspo and Electrical Safety rule) 102 Errection & Commissioning of (3x120+1x195+1x16) sq.mm ABC,necessary clamps, I-Hook, dead end clamp, suspension clamp,pierising connecter 1x35 sq.mm. & 1x16 sq.mm. PVC cable as per RESSPO norms will be arranged by the contractor exept AB cable as per Resspo and Electrical Safety rule 103 Errection & Commissioning of ACSR Weasl for neutral conductor in LT AB line with fixing of LT X-arm, LT shackle insulator, clamps etc. at existing LT pole Weasel Conductor provided by Deptt. 104 Errection andFixing the tailless unit 500 Amp.in existing LT cubical Box/Double pole making LT Bus Bar and its taping. 105 Opeing from old line & Reconnection with New LT Line of Consumers service cable of three phase /single phase 106 Single Phase 107 Three Phase 108 Laying/hanging of following LT cable of different sizes for main/distribution/connecting the main cable from T/F to tailless unit and for distribution, from tailless unit to LT section Pole, crimping the both ends of cable if required and tapping be made inside distribution box making channel of first class brick and filling with soil. 109 3 ½ x/240 sq. mm. 110 Errection & Commissioning of distribution boxes/kiosk on the LT poles including all clamps & materials required, connections & sealing its connection in between Distribution Box & ABC 1x35 sq. mm LT PVC cable (all required Local materialsarranged by the contractor as per Resspo and Electrical Safety rule) 111 Erection, grouting, plinthing,& painting of single support pole 9 mtr long STPfor LT line, including fixing of necessary clamps grouting in ratio1:4:8, cement, stone grit & coarse sand,plinthing of support of size 0.4x0.45x0.3 Mtr.with cement sand& bricks blast in ratio 1:4:8 and 12 mm thick plastring around the plingth in ratio 1:2:4 with 12 mm thickness curing of plingth should be done properly (Grouting & plinthing related all required material will be arranged by the contractor except 9 mtr long STPas per Resspo and Electrical Safety rule) 112 Earthing of support complete with the help of M.S. rod 16 mm dia and 2.5 mtr. long, fastening of G.I. wire with clamps/X-arm/ support to M.S. earth rodas per Resspo and Electrical Safety rule 113 Opeing from old line & Reconnection with New LT Line of Consumers service cable of three phase /single phase 114 Single Phase 115 Three Phase 116 Dismantling of old LT/HT supports along with all accessories on pole. 117 9 Mtr STP. 118 Loading cariedge and unloading of dismentaled item from site of work to centre store Naini/power house store. 119 9 Mtr STP 120 Other petty materials as conductor, cross arms, channels, angles, D.O. fuse set, TPMO, LT cubical box, clamps etc. 121 Eerection, grouting, plinthing & painting of 11 mtr single supportwith disconnent from old pole,tapping on new pole of 11 KV line ,1 no v cross armincluding fixing of necessary clamps, other accessories likeguarding angle ,disc insulator with fitting, pin insulator, L.T arm, shackle insulatoretc. grouting ratio 1:4:8, cement, stone grit & coarse sand, plinthing of support of size 0.4x0.45x0.3 Mtr.with cement sand& bricks blast in ratio 1:4:8 and 12 mm thick plastring around the plingth in ration 1:2:4 with 12 mm thickness curing of plingth should be done properly (Grouting , plinthing and all required material will be arranged by the contractor as per Resspo and Electrical Safety rule,only S.T.Pole provided by Deptt.) 122 Earthing of support complete with the help of M.S. rod 16 mm dia and 2.5 mtr. long, fastening of G.I. wire with clamps/X-arm/ support to M.S. earth rodas per Resspo and Electrical Safety rule 123 Opeing from old line & Reconnection with New LT Line of Consumers service cable of three phase /single phase 124 Single Phase 125 Three Phase 126 Dismantling of old LT/HT supports along with all accessories on pole. 127 9/11/13 Mtr STP. 128 Loading cariedge and unloading of dismentaled item from site of work to centre store Naini/power house store. 129 9/11 Mtr STP 130 Other petty materials as conductor, cross arms, channels, angles, D.O. fuse set, TPMO, LT cubical box, clamps etc. 131 Earthing of transformer body and neutral by lowering of chemical pipe (earthing)connecting with GI Strip of size 25x6 mm with clamps, as per Resspo and Electrical Safety rule 132 Cartage of 11/9 Mtr STP from Store to dump store/work Site Including loading and unloading 133 Cartage of 400/250 kva Transformer from Store to dump store/work Site Including loading andunloading 134 Cartage of LT 1x400, 1x240, 3.5x400, 3.5x240 sqmm from Store to dump store/work Site Including loading and unloading 135 Cartage of 3X185, 3x120, 3x70 SQ MM xlpe 11 KV XPLE CABLE from Store to dump store/work Site Including loading and unloading 136 Cartage of LT ABC from Store to dump store/work Site Including loading and unloading 137 Cartage of ACSR Weasel conductor from Store to dump store/work Site Including loading and unloading 138 Other petty materials as conductor, cross arms, channels, angles, D.O. fuse set, TPMO, LT cubical box, clamps etc.

Key Value

Document Fees
INR 11800 /-
EMD
INR 889500.0 /-
Tender Value
INR 4.44 Crore /-

BOQ Items

Name of Work: Supply of Material and works against system strengthening works in muncipal area on Semi Turn Key Basis in EUDD-Mayohall, Bamrauli & Tagore Town Under EUDC-II, Prayagraj.
Sl. No. Item Description
1SUPPLY OF MATERIALS (Part-A)
2Trip Coil OCB/VCB 24 V
3Multi Meter (100 Amp & 750V)
4Digital Earth Tester
5Volt Meter
6Clamp Meter
7Relly for 11 KV Pannel
8PLA Relly 24 V DC/240 V AC
9Closing Coil 24 V
10Breather
11WTI
12OTI
13Remote Switch
14Amp Meter
15LED Indicator Bulb
1633 KV Braker Moter
1733 KV Really ABB Make
1811 KV SLR 140 C Really
1911 KV Pannel Charging Motar
2011 KV Really P 122 micon
2111 KV Really P 127 micon
2233 KV REF 615 Really
23Busbar Spout (test)
24T/f Bushing HV/LV (Test)
25Structure for 33 KV VCB (Test)
26Structure for CT(Test)
27Structure for Linghting Arrester(Test)
28Control Cable 4x2.5 sqmm sizes (test)
29Control Cable 6x2.5 sqmm sizes (Test)
30Control Cable 4x1.5 sqmm sizes (Test)
31Holding Clamp for ST Pole-Cross Arm
32Holding Clamp for Top Chanel (STP/PCC)
33Suspension Clamp for ABC Cable
34Dead End Clamp for ABC Cable
35Stone Pad (300x300x75 MM)
36Danger Board with clamp for 11KV & 33 KV
37GI Barbed wire
38Aluminium Binding wire 6 SWG
39Aluminium Paint
40Chemical Earthing Complete
41Red Oxide Paint
42Bolts, Nut & Washer All size
43Aluminium Crimping Lug 70sqmm
44Aluminium Crimping Lug 240 sqmm
45Aluminium Crimping Lug 400 sqmm
46LT Shackle Insulator
47Copper Z Clamp
48I- Hook
49PRC 120 Sqmm
50PRC 90 Sqmm
51DD Wire PVC 70 Sqmm
52LT Cubical Box For Tailness Unit
53Tailness Unit 500 Amp
54Copper Strip 50x6sqmm
55GI Strip 50x6
56Service Clamp for ST Pole
57PVC Cable 1x35 Sqmm
58MS Angle 50x50x6 MM 18"
59U-Bolt with Nuts
60MOUNTING, FITTING & ERECTION OF WORK AS PER RESPO NORM. (Part-B)
61Eerection, grouting, plinthing & painting of 11 mtr single supportwith disconnent from old pole,tapping on new pole of 11 KV line ,1 no "v" cross armincluding fixing of necessary clamps, other accessories likeguarding angle ,disc insulator with fitting, pin insulator, L.T arm, shackle insulatoretc. grouting ratio 1:4:8, cement, stone grit & coarse sand, plinthing of support of size 0.4x0.45x0.3 Mtr.with cement sand& bricks blast in ratio 1:4:8 and 12 mm thick plastring around the plingth in ration 1:2:4 with 12 mm thickness curing of plingth should be done properly (Grouting , plinthing and all required material will be arranged by the contractor as per Resspo and Electrical Safety rule,only S.T.Pole provided by Deptt.)
62Fixing & grouting of stay rod with cement, sand and bricks ballast in ratio !:4:8 and fasteniong the stay wire with pole and stay rod nozzling.(Grouting material will be arranged by the contractorasper Resspo and Electrical safety rules.)
63Earthing of support complete with the help of M.S. rod 16 mm dia and 2.5 mtr. long, fastening of G.I. wire with clamps/X-arm/support to M.S. earth rodas per Resspo and Electrical Safety rule
64Spreading and stringing of 1 stay wire continuous conductor for hanging 11 KV cable including binding of insulator complete in all respect. The work includes jumpering/connecting of conductor at sectional poleas per Resspo and Electrical Safety rule
65Laying of single 11 KV, 3x185 sq mm XLPE cable Hanging with the help of stay wire/normal soil by digging of trench 900 mm deep, 600 mm wide including supply of required material like first class brick, stone pad and sand etc. The enter axial spacing between two cable( in case of any other cable is also running in parallel) should be in between o.25 mtr. to .40 mtr. The cable shall be laid between two continous rows of bricks, river sand packing on all side of cable shall be done. After laying down of the cable the stone slab shall be laid in such a manner so that cable channel is completely covered from top. The cable shall be laid strictly in compliance to RESSPO Norms and Electrical safety rules (All material required for laying will be supplied by the contractor. 11 KV cable provided by Deptt.)
66Laying of single 11 KV, 3x120 sq mm XLPE cable Hanging with the help of stay wire/normal soil by digging of trench 900 mm deep, 600 mm wide including supply of required material like first class brick, stone pad and sand etc. The enter axial spacing between two cable( in case of any other cable is also running in parallel) should be in between o.25 mtr. to .40 mtr. The cable shall be laid between two continous rows of bricks, river sand packing on all side of cable shall be done. After laying down of the cable the stone slab shall be laid in such a manner so that cable channel is completely covered from top. The cable shall be laid strictly in compliance to RESSPO Norms and Electrical safety rules (All material required for laying will be supplied by the contractor. 11 KV cable provided by Deptt.)
67Fixing ofHeat Shrink cable type end Terminations suitable for 11 KV, 3x185/3x120 sq mm XLPE cable and 11 KV 3x185/3x120 sq mmasper Resspo and Electrical safety rules.
68Outdoor/indoor jointing kit
69Straight through jointing kit
70Erection & commissioning of 11 KV VCB incoming in the switch gear room, by grouting base channel 100 x 50 x 6 x 1000mm. Fixing of 11 KV switchgears rag bolt with proper connection & earthing with GI Strip 50x6mm , control cable & Earthing Materials provided by contractor. 11 KV VCB provided by Deptt.
71Erection & commissioning of 11 KV VCBoutgoing in the switch gear room, by grouting base channel 100 x 50 x 6 x 1000mm. Fixing of 11 KV switchgears rag bolt with proper connection, & earthing with GI Strip 50x6mm , control cable & Earthing Materialsby contractor. 11 KV VCB provided by Deptt.
72Erection, grouting, plinthing, earthing & painting of 11 mtr long sub station type D/P formounting of T/Fs with all accessories like 11 kv fuse set, TPMO, top channel, grouting in ratio1:4:8, cement, stone grit & coarse sand, plinthing of support of size 0.4x0.45x0.3 Mtr.with cement sand& bricks blast in ratio 1:4:8 and 12 mm thick plastring around the plingth in ration 1:2:4 with 12 mm thickness curing of plingth should be done properly as per Resspo and Electrical Safety rule
73Fixing & grouting of stay rod with cement, sand and bricks ballast in ratio !:4:8 and fasteniong the stay wire with pole and stay rod nozzling.(Grouting material will be arranged by the contractorasper Resspo and Electrical safety rules.)
74Earthing of support complete with the help of M.S. rod 16 mm dia and 2.5 mtr. long, fastening of G.I. wire with clamps/X-arm/ support to M.S. earth rodas per Resspo and Electrical Safety rule
75Construction of 11/0.4 KV Transformer plinth in size 1.5x1.5x 1.8 mtr. Height, including 0.6 mtr. below G.l. in bottom 1:4:8 cement sand and brick ballast; concreting upto 15 cm. thickness after ramming should be done. Thickness of 1st class brick work should be 0.35 mtr. below G.L. and above G.L. It should be 0.23 mtr. brick work bill be done with 1:4 cement, sand mortar, The space between the four walls should be filled with sand by ramming and watering keeping a space of 0.15 mtr on lop for 1:2:4 cement stone ballast and sand concreting. The two channels should be grouted as per direction of site in charge. All the sides of wall above G, L. should be plastered by 1:6 cement sand mortar having 12 mm thickness.
76Providing and fixing of welded wire mesh fencing, around transformer plinth having one locking arrangements, Fencing should be provided by grouting MS angle 40x40x5 mm. length of 1.5 m. on all the sides as per standard practice and design. The painting of fencing should be done by good quality green paint with two coats after rubbing and cleaning and providing one coat red oxide primer. The fencing should be 2 M. above ground level. The rates should be inclusive of all materials required for completion of above work. (Plinthing and all required material will be arranged by the contractor per Resspo and Electrical Safety rule)
77Erection & commissioningof T/F 250 KVA on plinth. along with HT/LT connections with copper L-piece. Complete in all respect,as per Resspo and Electrical Safety rule
78Earthing of transformer body and neutral by lowering of chemical pipe/Rod (earthing)connecting with GI Strip of size 50x6 mm with clamps, as per Resspo and Electrical Safety rule
79Spreading and stringing of 1 stay wire continuous conductor for hanging 11 KV cable including binding of insulator complete in all respect. The work includes jumpering/connecting of conductor at sectional poleas per Resspo and Electrical Safety rule
80Laying of single 11 KV, 3x70 sq mm XLPE cable by Hanging with the help of stay wireThe cable shall be laid strictly in compliance to RESSPO Norms and Electrical safety rules (All material required for laying will be supplied by the contractor. 11 KV cable provided by Deptt.)
81Fixing ofHeat Shrink cable type end Terminations suitable for 11 KV, 3x70 sq mm XLPE cable and 11 KV 3x70 sq mmasper Resspo and Electrical safety rules. Outdoor jointing kit
82Laying of single 11 KV, 1x70 sq mm XLPE cable Hanging from HT line to T/F HT bhushing including Tapping from HT Line,crimping lug both sides and all Related HT,LT connection etc (All material required for laying will be supplied by the contractor. 11 KV cable provided by Deptt.)
83Erection and grouting of LT Cubical Box, Making platform for stepping, plastering the same with cement sand in raio 1:6 Fising the tailless unit 500 Amp making LT Bus Bar and its taping.
84Errection andFixing the tailless unit 500 Amp in existing LT cubical Box/Double pole making Copper LT Bus Bar and its taping.
85Laying/hanging of following LT cable of different sizes for main/distribution/connecting the main cable from T/F to tailless unit and for distribution, from tailless unit to LT section Pole, crimping the both ends of cable if required and tapping be made inside distribution box making channel of first class brick and filling with soil.
861x400 sq. mm.
873 ½x240 sq. mm.
88Errection & Commissioning of (3x120+1x195+1x16) sq.mm ABC,necessary clamps, I-Hook, dead end clamp, suspension clamp,pierising connecter 1x35 sq.mm. & 1x16 sq.mm. PVC cable as per RESSPO norms will be arranged by the contractor exept AB cable as per Resspo and Electrical Safety rule
89Errection & Commissioning of distribution boxes/kiosk on the LT poles including all clamps & materials required, connections & sealing its connection in between Distribution Box & ABC 1x35 sq. mm LT PVC cable (all required Local materialsarranged by the contractor as per Resspo and Electrical Safety rule)
90Construction of 11/0.4 KV Transformer plinth in size 1.5x1.5x 1.8 mtr. Height, including 0.6 mtr. below G.l. in bottom 1:4:8 cement sand and brick ballast; concreting upto 15 cm. thickness after ramming should be done. Thickness of 1st class brick work should be 0.35 mtr. below G.L. and above G.L. It should be 0.23 mtr. brick work bill be done with 1:4 cement, sand mortar, The space between the four walls should be filled with sand by ramming and watering keeping a space of 0.15 mtr on lop for 1:2:4 cement stone ballast and sand concreting. The two channels should be grouted as per direction of site in charge. All the sides of wall above G, L. should be plastered by 1:6 cement sand mortar having 12 mm thickness.
91Erection & commissioningof T/F 400 KVA on New/Existing plinth. along with HT/LT connections with copper L-piece. Complete in all respect,as per Resspo and Electrical Safety rule
92Earthing of transformer body and neutral by lowering of chemical pipe/Rod (earthing)connecting with GI Strip of size 50x6 mm with clamps, as per Resspo and Electrical Safety rule
93Erection and grouting of LT Cubical Box, Making platform for stepping, plastering the same with cement sand in raio 1:6 Fising the tailless nit 500/300 Amp making LT Bus Bar and its taping.
94Errection andFixing the 500 Amp. tailless unit in existing LT cubical Box/Double pole making LT Bus Bar and its taping.
95Laying/hanging of following LT cable of different sizes for main/distribution/connecting the main cable from T/F to tailless unit and for distribution, from tailless unit to LT section Pole, crimping the both ends of cable if required and tapping be made inside distribution box making channel of first class brick and filling with soil.
961x400 sq. mm.
973 ½ x240 sq. mm.
98Errection & Commissioning of (3x120+1x195+1x16)/ (3x95+1x70+1x16) sq.mm ABC,necessary clamps, I-Hook, dead end clamp, suspension clamp,pierising connecter 1x35 sq.mm. & 1x16 sq.mm. PVC cable as per RESSPO norms will be arranged by the contractor exept AB cable as per Resspo and Electrical Safety rule
99Errection & Commissioning of distribution boxes/kiosk on the LT poles including all clamps & materials required, connections & sealing its connection in between Distribution Box & ABC 1x35 sq. mm LT PVC cable (all required Local materialsarranged by the contractor as per Resspo and Electrical Safety rule)
100Dismantling of all the HT/LT line, connections & earthing of old 11/.4 kV, 250 KVA transformer along with LT cubical box, cable GO set, DO set & T/F, safe loading carrage and unloading of dismentled item from site of work to center store Naini/Power House store/New site.
101Erection, grouting, plinthing,& painting of single support pole 9 mtr long STPfor LT line, including fixing of necessary clamps grouting in ratio1:4:8, cement, stone grit & coarse sand,plinthing of support of size 0.4x0.45x0.3 Mtr.with cement sand& bricks blast in ratio 1:4:8 and 12 mm thick plastring around the plingth in ratio 1:2:4 with 12 mm thickness curing of plingth should be done properly (Grouting & plinthing related all required material will be arranged by the contractor except 9 mtr long STPas per Resspo and Electrical Safety rule)
102Errection & Commissioning of (3x120+1x195+1x16) sq.mm ABC,necessary clamps, I-Hook, dead end clamp, suspension clamp,pierising connecter 1x35 sq.mm. & 1x16 sq.mm. PVC cable as per RESSPO norms will be arranged by the contractor exept AB cable as per Resspo and Electrical Safety rule
103Errection & Commissioning of ACSR Weasl for neutral conductor in LT AB line with fixing of LT X-arm, LT shackle insulator, clamps etc. at existing LT pole Weasel Conductor provided by Deptt.
104Errection andFixing the tailless unit 500 Amp.in existing LT cubical Box/Double pole making LT Bus Bar and its taping.
105Opeing from old line & Reconnection with New LT Line of Consumers service cable of three phase /single phase
106Single Phase
107Three Phase
108Laying/hanging of following LT cable of different sizes for main/distribution/connecting the main cable from T/F to tailless unit and for distribution, from tailless unit to LT section Pole, crimping the both ends of cable if required and tapping be made inside distribution box making channel of first class brick and filling with soil.
1093 ½ x/240 sq. mm.
110Errection & Commissioning of distribution boxes/kiosk on the LT poles including all clamps & materials required, connections & sealing its connection in between Distribution Box & ABC 1x35 sq. mm LT PVC cable (all required Local materialsarranged by the contractor as per Resspo and Electrical Safety rule)
111Erection, grouting, plinthing,& painting of single support pole 9 mtr long STPfor LT line, including fixing of necessary clamps grouting in ratio1:4:8, cement, stone grit & coarse sand,plinthing of support of size 0.4x0.45x0.3 Mtr.with cement sand& bricks blast in ratio 1:4:8 and 12 mm thick plastring around the plingth in ratio 1:2:4 with 12 mm thickness curing of plingth should be done properly (Grouting & plinthing related all required material will be arranged by the contractor except 9 mtr long STPas per Resspo and Electrical Safety rule)
112Earthing of support complete with the help of M.S. rod 16 mm dia and 2.5 mtr. long, fastening of G.I. wire with clamps/X-arm/ support to M.S. earth rodas per Resspo and Electrical Safety rule
113Opeing from old line & Reconnection with New LT Line of Consumers service cable of three phase /single phase
114Single Phase
115Three Phase
116Dismantling of old LT/HT supports along with all accessories on pole.
1179 Mtr STP.
118Loading cariedge and unloading of dismentaled item from site of work to centre store Naini/power house store.
1199 Mtr STP
120Other petty materials as conductor, cross arms, channels, angles, D.O. fuse set, TPMO, LT cubical box, clamps etc.
121Eerection, grouting, plinthing & painting of 11 mtr single supportwith disconnent from old pole,tapping on new pole of 11 KV line ,1 no "v" cross armincluding fixing of necessary clamps, other accessories likeguarding angle ,disc insulator with fitting, pin insulator, L.T arm, shackle insulatoretc. grouting ratio 1:4:8, cement, stone grit & coarse sand, plinthing of support of size 0.4x0.45x0.3 Mtr.with cement sand& bricks blast in ratio 1:4:8 and 12 mm thick plastring around the plingth in ration 1:2:4 with 12 mm thickness curing of plingth should be done properly (Grouting , plinthing and all required material will be arranged by the contractor as per Resspo and Electrical Safety rule,only S.T.Pole provided by Deptt.)
122Earthing of support complete with the help of M.S. rod 16 mm dia and 2.5 mtr. long, fastening of G.I. wire with clamps/X-arm/ support to M.S. earth rodas per Resspo and Electrical Safety rule
123Opeing from old line & Reconnection with New LT Line of Consumers service cable of three phase /single phase
124Single Phase
125Three Phase
126Dismantling of old LT/HT supports along with all accessories on pole.
1279/11/13 Mtr STP.
128Loading cariedge and unloading of dismentaled item from site of work to centre store Naini/power house store.
1299/11 Mtr STP
130Other petty materials as conductor, cross arms, channels, angles, D.O. fuse set, TPMO, LT cubical box, clamps etc.
131Earthing of transformer body and neutral by lowering of chemical pipe (earthing)connecting with GI Strip of size 25x6 mm with clamps, as per Resspo and Electrical Safety rule
132Cartage of 11/9 Mtr STP from Store to dump store/work Site Including loading and unloading
133Cartage of 400/250 kva Transformer from Store to dump store/work Site Including loading and unloading
134Cartage of LT 1x400, 1x240, 3.5x400, 3.5x240 sqmm from Store to dump store/work Site Including loading and unloading
135Cartage of 3X185, 3x120, 3x70 SQ MM xlpe 11 KV XPLE CABLE from Store to dump store/work Site Including loading and unloading
136Cartage of LT ABC from Store to dump store/work Site Including loading and unloading
137Cartage of ACSR Weasel conductor from Store to dump store/work Site Including loading and unloading
138Other petty materials as conductor, cross arms, channels, angles, D.O. fuse set, TPMO, LT cubical box, clamps etc.
Disclaimer :