Tender For Construction Of Auditorium Hall Inc. Water Supply Senitary Fitting And Electrification Work In Govt. Digree College Sidhi, Under Sub. Dn. Sidhi Distt. Sidhi. Pwd Sor W.E.F 15-09-22, sidhi-Madhya Pradesh

Public Works Department-PWD has published Tender For Construction Of Auditorium Hall Inc. Water Supply Senitary Fitting And Electrification Work In Govt. Digree College Sidhi, Under Sub. Dn. Sidhi Distt. Sidhi. Pwd Sor W.E.F 15-09-22. Submission Date for this Tender is 23-09-2023. Electrification Work Tenders in sidhi Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

39711852
Tender For Construction Of Auditorium Hall Inc. Water Supply Senitary Fitting And Electrification Work In Govt. Digree College Sidhi, Under Sub. Dn. Sidhi Distt. Sidhi. Pwd Sor W.E.F 15-09-22
Open Tender
Indian
Madhya Pradesh
sidhi
23-09-2023

Tender Details

Tender For Construction Of Auditorium Hall Inc. Water Supply Senitary Fitting And Electrification Work In Govt. Digree College Sidhi, Under Sub. Dn. Sidhi Distt. Sidhi. Pwd Sor W.E.F 15-09-22

Key Value

Document Fees
INR 12500 /-
EMD
INR 132720.0 /-
Tender Value
INR 1.32 Crore /-

BOQ Items

Name of Work: Construction of Auditorioum Hall including Water Supply Sanitary fitting & Electrification work in AtGovt. Girls Digree College Sidhi, Distt. Sidhi (M.P.) "@ PWD Building SOR w.e.f. 15.09.2022
Sl. No. Item Description
1Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- Charge.
2Demolishing brick work manually/ by mechanical means including stacking ofserviceable material and disposal of unserviceable material within 50 metres leadas per direction of Engineer-in- Charge. 15.6.3 In cement mortar.
3Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- Charge: 15.8.2 In cement mortar.
4Surface dressing of the ground including removing vegetation and in- equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. in all kinds of soil.
5Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including dressing of sides and ramming of bottom disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed. (No extra lift is payable if work is done by mechanical means) All kinds of soil
6Filling available excavated earth (excluding hard rock/Ordinary rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
7Supplying and filling in plinth under floors including watering ramming consolidating in layers not exceeding 20cm in depth and dressing complete.
8Supplying and filling in plinth with crusher stone dust / coarse sand under floors including, watering, ramming and compacting in layers not exceeding 20cm in depth and dressing complete Note: - Maximum thickness of this layer shall be 20 cm.
9Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level : 4.1.2 With 40mm nominal size graded stone aggregate. 4.1.2.1 M-15 - Grade concrete
10Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level : 4.1.2 With 40mm nominal size graded stone aggregate. 4.1.2.2 M-10 Nominal (Mix -1 Cement : 3 sand : 6 graded stone aggregate)
11Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets etc. upto floor two level, excluding the cost of centering, shuttering and finishing : 4.2.1 With 20mm nominal size graded stone aggregate 4.2.1.2 M 20 – Grade concrete
12Providing and laying in position specified grade of reinforced cement concrete (with 20mm nominal size graded stone aggregate) excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.1 M 20 –Grade Concrete
13Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, posts and struts etc. above plinth level and upto floor two level excluding cost of centering, shuttering, finishing and reinforcement: 5.2.1 M-20 Grade Concrete
14Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate)in beams, suspended floors, roofs havingslope of any degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiralstaircases above plinth level and upto floor two level excluding the cost of centering, shuttering, finishing and reinforcement inconcrete grade. 5.3.1 M-20 Grade Concrete
15Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets etc. up to floor two level, excluding the cost of centering, shuttering and finishing : 4.2.1.3 M 15 — Grade concrete
16Centering and shuttering including strutting, propping etc. and removal of form for : 5.9.1 Foundations, footings, bases of columns, etc. for concrete up to plinth level.
17Centering and shuttering including strutting, propping etc. and removal of form for : 5.9.2 Walls (any thickness) in cluding attached pilasters butter esses, plinth beams and string courses etc.
18Centering and shuttering including strutting, propping etc. and removal of form for : 5.9.6 Columns, P i l l a r s , Piers, Abutments, Posts and Struts.
19Centering and shuttering including strutting, propping etc. and removal of form for : 5.9.3 Suspended floors, roofs, landings, balconies and access platform.
20Centering and shuttering including strutting, propping etc. and removal of form for : 5.9.5 Lintels, beams, girders, bressumers and cantilevers
21Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including cost of binding wire all wastages and overlaps, couplers (overlaps shall be provided as per requirement of IS 13920 for ductile detalingIS 456 RCC Design & SP 34 Reinforcement detailing ) etc. complete . (Note:- 1. Spacer bars (chairs) shall be paid separately as shown in the drawing and as per direction of engineer in charge. 2. No extra payment shall be done for overlaps and/or couplers. 3. Couplers shall be conforming to IS code on “Reinforcement Couplers for Mechanical Splices of Bars for Concrete Reinforcement - Specification”) 5.16.3 Cold twisted bars (CTD)
22Brick work with extruded burnt fly ash clay sewer bricks (Conforming to IS: 4885 ) in foundation and plinth : Cement Mortar 1:4 ( 1 cement : 4 sand)
23Brick work with fly ash lime bricks (FALG Bricks) conforming to IS:12894-2002, in super structure above plinth level up to floor two level in : 6.7.3 Having 50 kg / cm2 average compressive strength. 6.7.3.2 Cement mortar 1:6 (1 cement : 6 sand)
24Half brick masonry with fly ash lime Gypsum bricks (FALG bricks) conforming to IS: 12894, in super structure above plinth and upto floor two level. 6.15.3 Having 50 kg/cm2 average compressive strength. 6.15.3.2 Cement mortar 1 : 4 (1 cement : 4 sand)
25Extra for providing and placing in position 2 Nos. 8mm dia. M.S. bars at every third course of in half brick masonry.
26Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutter. 9.18.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
27Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured).
28Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
29Providing and Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding qualityconforming to IS : 2046 Type S including cost of adhesive of approved quality. 9.134.2 1.0 mm thick.
30Providing and fixing factory made door frame (single rebate) made out of single piece extruded solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having62 mm width and 32 mm thickness, frame will be mitred and Jointed with self driven self tapping screws of size 38 mm x 4 mm and PVC solvent cement, including fixing the frame to wall with suitable dia and length anchor fastener as per manufacturer’s specification and direction of Engineer-in- charge.
31Providing and fixing factory made 30 mm thick PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for styles and 15x15mm for top and bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5mm thick heat moulded PVC "C" channel of size 30mm thickness, 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45degree angle on both side forming styles; and 5mm thick, 95mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115mm wide PVC sheet out of which 75mm shall be flat and 20mmshall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be 9.166.1 Plain PVC door shutters.
32Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete: 9.109.1 300x16 mm
33Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete: 9.109.2 250x16 mm
34Providing and fixing aluminium towerbolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: 9.110.2 300x10 mm
35Providing and fixing aluminium towerbolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: 9.110.4 200x10 mm
36Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: 9.113.1 125 mm
37Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 9.114.2 Twin rubber stopper
38Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or dash fastener shall be paid for separately). 9.1.2 Sal wood
39Providing and fixing M.S. Tubular frames and shutters or frames only or shuttersonly for doors, windows, ventilators and cupboard with any sections, made of 1.60 mm or 1.25 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size as per drawing, including fixing of necessary butt hinges, stays and screws andapplying a priming coat of approved steel primer excluding cost of all fittings such as handles, tower bolts, sliding door bolts, latches etc. and panels. 10.13.1 Fixing with 15x3 mm lugs 10 cm. long embedded in cement concrete block 15x10x10 cm of Cement Concrete 1:3:6 (1 Cement : 3 sand : 6 graded stone aggregate 20 mm nominal size).
40Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 10.22.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
41Steel work in built up M.S. tubular section (round, square or rectangular hollow tubes etc.) trusses/frame work etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washersetc. complete. 10.14.1 Hot finished welded type tubes
42Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete with base of cement mortar 1 : 4 (1 cement : 4 sand) 25 mm thick.(Area of slab to be over 0.25 sqm) Note: - Deduction shall be made for not mirror polishing according to item no 11.43
43Kota stone slabs in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
44Providing and laying rectified Glazed Ceramic floor tiles 300x300 mm or more (having thickness 9 to 10mm) of 1st quality conforming to IS : 15622 of approved make in all colours white, ivory, grey, fume red brown laid on 20mm thick cement mortar 1:4 (1 Cement : 4 sand) including grouting the joints with white cement and matching pigments etc., complete.
45Providing and laying rectified Glazed Ceramic wall tiles 300x450 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in all colours white, ivory, grey, fume red brown laid on 12 mm thick cement mortar 1:3 (1 Cement : 3 sand) including grouting the joints with white cement and matching pigments etc., complete.
46Providing and fixing 18mm thick gang saw cut mirror polished (premoulded and prepolished) machine cut for kitchen platforms, vanitycounters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding and polishing to edge to givehigh gloss finish wherever required etc. complete at all levels. Samples approved by Engineer-in- Charge. 11.22.5 Cuddpah stone
47Chequeredterrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors jointed with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing complete on 20 mm thick bed of cement mortar 1:4 (1 cement :4 sand) : 11.17.3 Dark shade pigment using ordinary cement.
48Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 0.05 % total coated thickness, Zinc coating 120gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15- 18 microns using self-drilling/ self- tapping screws complete : 12.16.1 Ridges plain (500 - 600mm).
49Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 sand : 4 stone aggregate 10mm and down grade) including finishing with cement mortar 1:3 (1 cement : 3 sand) as per standard design : In 75x75mm deep chase
50Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints toget required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre- painted with polyester paint, allcomplete for all heightsas per specifications, drawings and as directed by Engineer-in-charge. 12.59.4 12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing.
51Providing and Fixing colour coated profile sheet of minimum 1015 mm effective cover width and nominal 28.5 mm deep ribs with subtle square fluting in the five pan at nominal 203 mm centre-to-centre. The end rib shall be designed for anti-capillary action,to avoid any seepage of water through the lateral overlap. The profile sheet of 0.5 mm thick, Hi-strength steel with min. 550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% Aluminium, 45% Zinc) as per AS 1397 - Zincalume AZ150 (Min. 150 gms/sq.mt total on both sides) with steel quality paint coat. The paint shall have a total coating thickness of nominal 35 µm, comprising of nominal 20 µm exterior coat on top surface and nominal 5 µm reverse coat on back surface over nominal 5 µm primer coat on both surface. The sheet shall have brand marking of the manufacturer giving product details on the back of the sheet at every 1 meter c/c for confirming genuinity of the material. The sheet shall be fixed using self- drilling /self-tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape
526 mm cement plaster of mix : 1:3 (1 cement : 3 sand)
5315 mm cement plaster on the rough side of single or half brick wall of mix 13.2.2 1:6 (1 cement : 6 sand)
5412 mm cement plaster of mix : 13.1.2 1:6 (1 cement : 6 sand)
5512 mm cement plaster finished with a floating coat of neat cement of mix : 13.4.1 1:3 (1 cement : 3 sand)
56Providing for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
57Providing and applying white cement based putty of average thickness 1 mm, of approved brand over the plastered wall surface to prepare the surface even and smooth i/c all cost of material, labour and scaffold etc in all position complete. Note : Putty shall be applied only on the internal walls, for application on the exterior walls prior permission of APD/Chief Engineer will be required.
58Finishing walls by any mechanical or manual means with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : 13.54.3 Two or more coats applied on walls @ 1.25 ltr/10 sqm. Over and including one coat of Special primer applied @ 0.75 ltr / 10 sqm.
59Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture.
60Making plinth protection 50mm thick of cement concrete grade M10 over 75mm bed of dry metal ballast 40mm nominal size well rammed and consolidated and filled with sand including finishing the top smooth (with 20mm nominalsize graded stone aggregate.)
61Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top,bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : 21.1.1 For fixed portion. 21.1.1.3 Polyester powder coated aluminium (minimum thicknessof polyester powder coating 50 micron)
6221.1.2 For shutters of doors, windows and ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings whereverrequired including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). 21.1.2.3 Polyester powder coated aluminium (minimum thicknessof polyester powder coating 50 micron)
63Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item) : 21.3.2 With float glass panes of 5.0 mm thickness (weight not less than 12.50 kg/sqm )
64Providing and laying factory made machine pressed precast cement concrete interlocking paver block of any shape and size conforming to IS:15658- 2006 and ISI marked of 60 mm thickness, M-30 grade with grey cement and pigment all as specified. Made by block making machine with strong vibratory compaction, laid in required colour andpattern over and including 50mm thick compacted bed of stone dust, filling the jointswith sand etc. all complete as per thedirection of Engineer-in- Charge.
65Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work.
66Water Supply Sanitary fitting Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100mm sand cast Iron P or Strap, UPVC P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures completeincluding cutting and making good thewalls and floors wherever required : 17.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests.
67Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete including cutting andmaking good the walls and floors wherever required : 17.2.1 W.C. pan with ISI marked white solid plastic seat and lid
68Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass including painting of fittings and cutting and making good the walls and floors wherever required 17.7.4 Range of four half stall urinals with 10 litre P.V.C. automatic flushing cistern.
69Providing and fixing 18mm thick gang saw cut mirror polished (premoulded and prepolished) machine cut for kitchen platforms, vanitycounters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding and polishing to edge to givehigh gloss finish wherever required etc. complete at all levels. Samples approved by Engineer-in- Charge. 11.22.2 Granite fine grained dark crystal of other colours and various patterns
70Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 17.6.4 Range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern.
71Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : 17.11.9 White Vitreous China Surgeon type wash basin of size 660x460 mm with single 15 mm C.P. brass pillar tapswith elbow operated levers ISI marked.
72Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 17.64.2 Flexible pipe (only in residential & complaxes) 17.64.2.1 32 mm dia
73Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 sand ) R.C.C. top slab with Cement Concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stoneaggregate 20mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design 19.9.1 Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be notless than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : 19.9.1.1 With well burnt bricks
74Providing and fixing uplasticised PVC connection pipe with brass unions 18.17.2 45 cm length 18.17.2.1 15 mm nominal bore
75Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank
76Providing and fixing UPVC trap ofself cleaning design complete. Including cost of cutting and making good the wall and floors. 100 mm inlet and 75 mm outlet
77Providing and fixing PTMT grating of approved quality and colour. 18.48.1 Circular type. 18.48.1.1 100 mm nominal dia.
78Boring/drilling bore well of required dia perfectly vertical to receive casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire and running charges of all equipments, tools, plants and machineries required for the job, all complete as per direction of Engineer–in-Charge, upto 90 metre depth below ground level. 16.1.2 Rocky strata including Boulders.Upto 90 metre depth. 16.1.2.2 150 mm dia.
79Boring/drilling bore well of required dia perfectly vertical to receive casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire and running charges of all equipments, tools, plants and machineries required for the job, all complete as per direction of Engineer –in-charge, beyond 90 metre depth below ground level. 16.2.2 Rocky strata including Boulders. 16.2.2.2 150 mm dia.
80Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS)pipes with ribs, conforming to IS: 12818, including hire and labour charges, fittings and accessories etc. All complete, for all depths, as per direction of Engineer-in- Charge. 16.3.2 150 mm nominal size dia.
81Providing and fixing on wall face Rigid Unplasticised rigid PVC (upvc) Single socketed rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 12.32.2 110 mm diameter (minimum wall thickness 2.2mm)
82Providing and fixing unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 17.59.1 Coupler 17.59.1.2 110 mm
83Providing and fixing unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 17.59.3 Single tee with door 17.59.3.2 110x110x110 mm
84Providing and fixing unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 17.59.5 Bend 87.50 17.59.5.2 110 mm bend
85Providing and laying cement concrete 1:3:6 (1 cement: 3sand: 6 graded stone aggregate 20 mm nominal size) all-round PVC. pipes including bed concrete as per standard design: 19.5.1 110 mm diameter PVC. Pipe
86Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of jointscomplete as per direction of Engineer- in-Charge. 18.6.1.3 25 mm nominal outer dia .Pipes.
87Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of jointscomplete as per direction of Engineer- in-Charge. 18.6.1.2 20 mm nominal outer dia .Pipes.
88Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of jointscomplete as per direction of Engineer- in-Charge. 18.6.1.1 15 mm nominal outer dia .Pipes.
89Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plainand brass threaded fittings. This included jointing of pipes and fittings with onestep CPVC solvent cement, trenching, refilling andtesting of joints complete as per direction of Engineer-in- Charge. External Work 18.7.2 20 mm nominal outer dia .Pipes.
90Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plainand brass threaded fittings. This included jointing of pipes and fittings with onestep CPVC solvent cement, trenching, refilling andtesting of joints complete as per direction of Engineer-in- Charge. External Work 18.7.3 25 mm nominal outer dia .Pipes.
91Providing and fixing gun metal non- return valve of approved quality (screwed end) : 18.15.1 25 mm nominal bore 18.15.1.1 Horizontal
92Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 18.14.2 20 mm nominal bore
93Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 18.14.3 25 mm nominal bore
94Providing and fixing C.P. brass bib cock of approved quality conforming to IS: 8931, 15 mm nominal bore.
95Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS: 8931. 15 mm nominal bore.
96Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:893115 mm nominal bore
97Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : 18.27.3 25 mm nominal bore.
98Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded inand including cement concrete blocks 10x10x10cm of Cement Concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. 12.28.1 100 mm diameter
99Providing and fixing CP jet assembly to including connection etc complete.
100Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement :2 sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement :5 sand:10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement :3 sand) 12mm thick finished with a floating coat of neat cement complete as per standard design :- 18.18.1 With common burnt clay bricks of 25 kg /sqcm compressive strength.
101Constructing soak pit 1.20x1.20x1.20m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20m long complete as per standard design.
102Providing and laying cement all-round S.W. pipes concrete 1:5:10 (1 cement : 5 sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design: 19.2.6 300 mm diameter S.W. pipe
103Electrification work Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screwless connector for joints etc. as required as per specification for :- 4.1.1 Light Point/Fan Points. 4.1.1.1 Primary short point
104Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screwless connector for joints etc. as required as per specification for :- 4.1.1 Light Point/Fan Points. 4.1.1.2 Primary medium point
105Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screwless connector for joints etc. as required as per specification for :- 4.1.1 Light Point/Fan Points. 4.1.1.3 Primary long point
106Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screwless connector for joints etc. as required as per specification for :- 4.1.3 3 Pin 6 Amp socket outlet on separate board 4.1.3.1 Short point
107Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screwless connector for joints etc. as required as per specification for :- 4.1.3 3 Pin 6 Amp socket outlet on separate board 4.1.3.2 Medium point
108Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screwless connector for joints etc. as required as per specification for :- 4.1.3 3 Pin 6 Amp socket outlet on separate board 4.1.3.3 Long point
109Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screwless connector for joints etc. as required as per specification for :- 4.1.4 Call bell/buzzer points 4.1.4.3 Long point
110Point wiring (excluding metallic switch box & sheet but including switches, sockets) for 3 pin 6 Amp. socket outlet point with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size and 1.5sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit with required materials as per specification on same board.
111Wiring for circuit wiring with PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) of ISI marked suitable size etc. as required as per specification 4.3.1 2x2.5 Sq.mm.
112Wiring for circuit wiring with PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) of ISI marked suitable size etc. as required as per specification 4.3.2 4x2.5 Sq.mm.
113Wiring for circuit wiring with PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) of ISI marked suitable size etc. as required as per specification 4.3.3 6x2.5 Sq.mm.
114Wiring for circuit wiring with PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) of ISI marked suitable size etc. as required as per specification 4.3.4 8x2.5 Sq.mm.
115Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size etc. with 20/16 Amp. F.T. switch &ocket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screwless connector for joints as per specification for :- 9.1.1 On separate board 9.1.1.1 Short point
116Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size etc. with 20/16 Amp. F.T. switch &ocket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screwless connector for joints as per specification for :- 9.1.1 On separate board 9.1.1.2 Medium point
117Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size etc. with 20/16 Amp. F.T. switch &ocket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screwless connector for joints as per specification for :- 9.1.1 On separate board 9.1.1.3 Long point
118Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size etc. with 20/16 Amp. F.T. switch &ocket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screwless connector for joints as per specification for :- 9.1.1 On separate board 9.1.1.4 Extra long-I
119Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size etc. with 20/16 Amp. F.T. switch &ocket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screwless connector for joints as per specification for :- 9.1.1 On separate board 9.1.1.5 Extra long-II
120Supply and fixing PVC conduit ISI marked FRLS along with the accessories in concealed system etc. as required 16.1.1 PVC. conduit 20 mm (HMS)
121Supply and fixing PVC conduit ISI marked FRLS along with the accessories in concealed system etc. as required 16.1.2 PVC. conduit 25 mm (HMS)
122Supply and fixing PVC conduit ISI marked FRLS along with the accessories in concealed system etc. as required 16.1.3 PVC. conduit 32 mm (HMS)
123Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:- 18.3.1 1 Or 2 Module PVC box
124Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:- 18.3.2 3 Module PVC box
125Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:- 18.3.3 4 Module PVC box
126Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:- 18.3.5 8/9 Module PVC box
127Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:- 18.3.6 12 Module PVC box
128Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:- 18.3.7 16 Module PVC box
129Supplying and drawing single core PVC insulated cable FRLS with copper multi strand conductor ISI marked in existing rigid PVC casing and capping/conduit in surface or concealed as per specification. 19.1.1 1.5 sq. mm. wire 19.1.1.3 3 X 1.5 sq. mm.
130Supplying and drawing single core PVC insulated cable FRLS with copper multi strand conductor ISI marked in existing rigid PVC casing and capping/conduit in surface or concealed as per specification. 19.1.1 1.5 sq. mm. wire 19.1.1.4 4 X 1.5 sq. mm.
131Supplying, erection and testing of approved make electric Ceiling fan of double ball bearing complete with standard down rod, canopy, hanging shackle, Aluminium blades, without regulator, A.C. 230-250 volts including connections with all necessary material complete of approved as required confirming to IS :374/2019 with upto date amendments. 30.1.2 Ceiling Fan (ISI marked)-1200 mm Sweep, with minimum air delivery 210 m³/min and service value = 4.00 as per BEE..
132Supply and fixing of approved make step type modular electronic fan regulator including connection etc. as required on existing board 29.25.2 100 Watt(2 module)
133Supply, fixing & testing of approved make of LED integral type bollard cylindrical/square shape housing cast aluminium dome shape top cover fixed with cylindrical shape acrylic cover having base plate with holes for direct mounting complete with all accessories including preparation of foundation, fixing, connection etc. as required. LED of 1 to 3 Watt each assembled on single MCPCB, system lumens output with efficacy>90 lm/W. luminaire having color temp upto 6500K & 50000 burning hrs. life with minimum @ L 70, The colour rendering index of LED light should be more than 70. Luminiare, comprises of driver PF> 0.95 & surge protection 10KV. IP65 protection. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. 31.16.1 Bollard LED 8-10 Watt cylindrical shape height > 700mm, color temp 3000-6000k
134Supply, fixing & testing of approved make of LED integral type bollard cylindrical/square shape housing cast aluminium dome shape top cover fixed with cylindrical shape acrylic cover having base plate with holes for direct mounting complete with all accessories including preparation of foundation, fixing, connection etc. as required. LED of 1 to 3 Watt each assembled on single MCPCB, system lumens output with efficacy>90 lm/W. luminaire having color temp upto 6500K & 50000 burning hrs. life with minimum @ L 70, The colour rendering index of LED light should be more than 70. Luminiare, comprises of driver PF> 0.95 & surge protection 10KV. IP65 protection. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. 31.16.2 Bollard LED 8-10 Watt mushroom shape height > 600mm, color temp 3000-6000k
135Suppling,Fixing and Testing of Compact ,Fluorescent Lamp Non-Retrofit ISI marked of approved make as required as per specification 29.24.5 18 Watt, 4Pin / 4 Pin, L Type
136Suppling,Fixing and Testing of Compact ,Fluorescent Lamp Non-Retrofit ISI marked of approved make as required as per specification 29.24.6 36 Watt, 4Pin L Type
137Supply and fixing of recessed mounting LED swivel type COB downlighter, having color temp upto 6500K & having 20000 burning hrs life with minimum @ L 70, system lumen output should be minimum with efficacy>80lm/W. LED driver PF > 0.9, THD < 20% & surge protection 5KV. The colour rendering index of LED light should be more than 70. Housing made of pressure die cast aluminium / CRCA powder coated frame with glare free diffused polycorbonate cover. Submission LM 80-08 Form LED Source Manufacturer & LM79-08 / IS16106 from NABL approved lab. Manufacturer manadatory. i/c connection wire, testing etc. to complete the job. Guarantee as per tender agreement condition. 31.8.2 6/7W
138Supply and fixing of recessed mounting LED swivel type COB downlighter, having color temp upto 6500K & having 20000 burning hrs life with minimum @ L 70, system lumen output should be minimum with efficacy>80lm/W. LED driver PF > 0.9, THD < 20% & surge protection 5KV. The colour rendering index of LED light should be more than 70. Housing made of pressure die cast aluminium / CRCA powder coated frame with glare free diffused polycorbonate cover. Submission LM 80-08 Form LED Source Manufacturer & LM79-08 / IS16106 from NABL approved lab. Manufacturer manadatory. i/c connection wire, testing etc. to complete the job. Guarantee as per tender agreement condition. 31.8.4 12/15W
139Supplying of approved make, powder coated metal double door vertical TPN MCB DB IP 43 protection with provision for MCCB upto160A TP/FP 36kA as incomer and space for SP/TP MCBs as outgoing (without MCCB/MCBs) inclusive of busbar & connections etc 27.14.3 8 Way without MCCB
140Supplying of approved make, powder coated metal double door vertical TPN MCB DB IP 43 protection with provision for MCCB upto160A TP/FP 36kA as incomer and space for SP/TP MCBs as outgoing (without MCCB/MCBs) inclusive of busbar & connections etc 27.14.4 12 Way without MCCB
141Fixing of MCB/MCCB/Isolator in sheet steel enclosure as required as per accepted practice, including mounting on busbar and cable connection etc. complete (labour only) 28.4.1 MCB/Isolator SP/DP
142Fixing of MCB/MCCB/Isolator in sheet steel enclosure as required as per accepted practice, including mounting on busbar and cable connection etc. complete (labour only) 28.4.2 MCB/MCCB Isolator TP/TPN/FP
143Labour charges for fixing sheet steel enclosures, MCB/MCCBDB flush mounting type, as per accepted practice, duly embedded and end plate completely flushed in wall, cable connection etc. complete
144Wiring for sub-mains with PVC insulated cable FRLS with copper multi strand conductor ISI marked in recessed/concealed rigid PVC conduit (HMS) FRLS ISI marked of suitable size (conduit included) including 2mm thick accessories, connection etc, as required as per specification. (Refer General Notes for Classification of Conduit Wiring Point No.11) 23.1.4 4 Wire sub main 23.1.4.3 6.0 sq. mm. cable
145Wiring for sub-mains with PVC insulated cable FRLS with copper multi strand conductor ISI marked in recessed/concealed rigid PVC conduit (HMS) FRLS ISI marked of suitable size (conduit included) including 2mm thick accessories, connection etc, as required as per specification. (Refer General Notes for Classification of Conduit Wiring Point No.11) 23.1.4 4 Wire sub main 23.1.4.4 10.0 sq. mm. cable
146Wiring for sub-mains with PVC insulated cable FRLS with copper multi strand conductor ISI marked in recessed/concealed rigid PVC conduit (HMS) FRLS ISI marked of suitable size (conduit included) including 2mm thick accessories, connection etc, as required as per specification. (Refer General Notes for Classification of Conduit Wiring Point No.11) 23.1.4 4 Wire sub main 23.1.4.5 16.0 sq. mm. cable
147Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of "C" series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002 & 60947-2 but without enclosures :- 27.8.1 Single pole 27.8.1.2 MCB SP 6Amp to 32Amp 10kA rating
148Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of "C" series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002 & 60947-2 but without enclosures :- 27.8.3 For Triple pole 27.8.3.3 MCB TP For 40Amp 10kA rating
149Supply of XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI marked with alu. stranded /solid conductor 41.1.8 3½ core armoured 41.1.8.1 25 sq. mm
150Supply of XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI marked with alu. stranded /solid conductor 41.1.8 3½ core armoured 41.1.8.2 35 sq. mm
151Supply of XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI marked with alu. stranded /solid conductor 41.1.8 3½ core armoured 41.1.8.3 50 sq. mm
152Supply of XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI marked with alu. stranded /solid conductor 41.1.10 4 4 core armoured 41.1.10.2 10 sq. mm.
153Supply of XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI marked with alu. stranded /solid conductor 41.1.3 Unarmoured 2 core 41.1.3.1 2.5 sq. mm.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail