Tender For Work Of 11 Kv Overhead Line And Underground Cable At Hawai Patti Under Edd-Karwi Chitrakoot
Tender Value
18 Lakhs
Estimated cost
Bid Submission
20 Sep 2023
0 days left
EMD
18000
Bank guarantee accepted
Document Fee
3540
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
karwi → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Work Of 11 Kv Overhead Line And Underground Cable At Hawai Patti Under Edd-Karwi Chitrakoot
BOQ
| Sl. No. | Item Description |
| 1 | WORK |
| 2 | Cartage ofPole & material from store centrefrom any other place to the respective site of work through the Kachha Pacca road inclading the work of its loading & unloading at the respective ends also including the work of dragging etc. and also including the cost of labour, T&P carrier etc. required for proper completion of work. |
| 3 | PCC Pole 8.5 Mtr Long |
| 4 | 11 KV XLPE Cable 3X120 sq mm |
| 5 | Safe cartage of line material viz. conductor, cable, GI earth wire, cross arm, angle, channel, insulator, clamps and other line material from store centre or from any other place to the respective site of work through the Kachha Pacca road including the work of its loading & unloading at the respective ends also including the work of dragging. |
| 6 | Erection of 8.5 Mtr. Single PCC Pole including complete. H.T/L.T fittings as per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work. |
| 7 | Grouting of 8.5 Mtr. Single PCC Poleper RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work. |
| 8 | Laying of 11 KV XLPE Cable 3X120 sq mm twin cableby digging of trench 1050 mm, deep, 750 mm wide its boxing with brick,sand after laying of cable separation of cable by brick wall local sand filling and proper levelling& ramming (all the material shall be arranged by contractor) |
| 9 | Erection and Grouting of Earthing Completeincluding the work of nozelling etc. as per RESPO manual and also including the cost of all grouting material, labour, T&P etc required for proper completion of work. |
| 10 | Erection and Grouting of Stay set Complete including the work of nozelling etc. as per RESPO manual and also including the cost of all grouting material, labour, T&P etc required for proper completion of work. |
| 11 | Fixing & Commisioning of Danger Plate With Clamp as per norms complete in all respect as per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work. |
| 12 | Laying, Sagging and Binding & Jumpring of ACSR weasel conductor as per direction of Supervising Engineer. It including the cost of Labour T&P carrier etc required for proper completion of work. |
| 13 | Fixing & Commisioning of Ms Top Channel with clamp as per norms complete in all respect as per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work. |
| 14 | Fixing & Commisioning of Ms X-Bracing Angle with Clamp as per norms complete in all respect as per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work. |
| 15 | Fixing & Commisioning of 11 KV Jointing Kit 3X120 sq mm (Outdoor/Indoor) as per norms complete in all respect as per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work. (Arrange by the contractor on his own cost) |
| 16 | Fixing & Commisioning of 11 KV JOINTING KIT STRAIGHT THROUGH(3*120 Sqmm) as per norms complete in all respect as per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work. (Arrange by the contractor on his own cost) |
| 17 | ARRANGEMENT OF ROOM (5*5*5QFT WITH DOUBLE M.S.ANGLE 6FT) FOR RISER OF BOTH SIDE CABLE as per norms complete in all respect as per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work. (Material Arrange by the contractor on his own cost) |
| 18 | Fixing & Commisioning of 140mm OD PN-4 PE-80 Grade UV stabilized HDPE pipe as per IS 4984 in 6 mtr as per norms complete in all respect as per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work.(HDPE Pipe Arrange by the contractor on his own cost) |
| 19 | Fixing & Commisioning of GI PIPE 6\" DIA as per norms complete in all respect as per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work. (GI Pipe Arrange by the contractor on his own cost) |
| 20 | Road Restoration Charges for Pucca Road Crosingas per direction of Supervising Engineer. It including the cost of Labour T&P carrier etc required for proper completion of work.(All Civil material arrange by the contractor on his own cost) |
AI Tender Summary
Tender Timeline
Sep 15, 2023
11:30 IST
Tender Published
Tender notice published.
CompletedSep 20, 2023
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedSep 21, 2023
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer