Tender For Repair, Maintenance Of Unserviceable Perimeter Lights, Tower Lights, Lt Panels, Timers And Allied Works And Repair, Maintenance And Replacement Of Unserviceable Solar Street Lights And Accessories, Pole Painting And Pole Foundation At Nav, visakhapatnam-Andhra Pradesh

Military Engineer Services-MES has published Tender For Repair, Maintenance Of Unserviceable Perimeter Lights, Tower Lights, Lt Panels, Timers And Allied Works And Repair, Maintenance And Replacement Of Unserviceable Solar Street Lights And Accessories, Pole Painting And Pole Foundation At Nav. Submission Date for this Tender is 30-09-2023. LED Light Tenders in visakhapatnam Andhra Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

39705843
Tender For Repair, Maintenance Of Unserviceable Perimeter Lights, Tower Lights, Lt Panels, Timers And Allied Works And Repair, Maintenance And Replacement Of Unserviceable Solar Street Lights And Accessories, Pole Painting And Pole Foundation At Nav
Open Tender
Indian
Andhra Pradesh
visakhapatnam
30-09-2023

Tender Details

Repair, Maintenance Of Unserviceable Perimeter Lights, Tower Lights, Lt Panels, Timers And Allied Works And Repair, Maintenance And Replacement Of Unserviceable Solar Street Lights And Accessories, Pole Painting And Pole Foundation At Naval Dockyard

Key Value

Document Fees
INR 1000 /-
EMD
INR 144940.0 /-
Tender Value
INR 79.96 Lakhs /-

BOQ Items

Name of Work: REPAIR, MAINTENANCE OF UNSERVICEABLE PERIMETER LIGHTS, TOWER LIGHTS, LT PANELS, TIMERS AND ALLIED WORKS AND REPAIR, MAINTENANCE AND REPLACEMENT OF UNSERVICEABLE SOLAR STREET LIGHTS AND ACCESSORIES, POLE PAINTING AND POLE FOUNDATION ATNAVAL DOCKYARD VISAKHAPATNAM UNDER GE (I) (DM) VISAKHAPATNAM
Sl. No. Item Description
1S&F PVC junction box of outdoor type, weather proof, with provision of hole at bottom for cable entry, hinged door with locking arrangement, of size not less than 200mm (L) x 100mm(B)x 300mm (H) incl taking down unserviceable one, fixed to pole with MS clamp, nuts, bolts and washers complete including one 3ph 4 pole connection block complete including taking out old unserviceable one complete all as specified and as directed. Make- Syntex / Hansel
2S&F street light bracket made with 40mm bore medium grade MS pipe, bent to shape of total length 1200 mm with 2 pair of MS clamp, made out from 50mm x 6mm MS flat iron with suitable size of nuts bolts washers including painted brack with one coat of red oxide and two coat of aluminium paint complete including dismatling taking out unsv one complete all as specified and as directed.
3Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in soft loose soil complete all as specified and as directed.
4Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed.
5Removing of excavated material not exceeding 50m and depositing where directed at a level not exceeding1.5m above the starting point complete all as specified and as directed.
6Supply and fixing/Layingdouble layer HDPE corrugatd pipe 40mm bore through trench.surface or wall including required necessary saddle/clamp any heightfor cable protection laid in trenches in lieu of sand/brick protection complete all as specified and as directed.
7Supply and fixing/Laying through trench.surface or wall including required necessary saddle/clamp any hightHDPE double wall pipe corugated pipe of size 75 mm dia for cable protection laid in trenches in lieu of sand/brick protection complete all as specified and as directed.
8Supply and laying in trenches/surface/ wall/trusses PVC insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 Volts grade cross section area 6 Sqmm 3 core and connection complete with aluminium cable lugsincl dismantling taking down unsv one complete all as specified and as directed.
9All as per ser No 8.00 above but of size 10 sqmm, 4 core
10All as per ser No 8.00 above but of size 16 Sqmm 4 core
11All as per ser No 8.00 above but of size 25 Sqmm 3.5 core
12All as per ser No 8.00 above but of Size 35 Sqmm 3.5 core
13S/F MS cross arm, bracings, supports, clamps, nuts, bolts and washers on Pole including painting with one primer coat, one under coat and one finishing coat of aluminium paint incl dismantling taking down unserviceable one complete all as specified and as directed.
14M&L for dismatling and taking out street light cable loop near pole forsize of cable 6sqmm to 25 sqmm after dismantling connection from junction box, cutting, removing damaged portion of the cable ends, providing new aluminium cable end terminals, laying of cable through protection pipe through coping to junction box including necessary connection complete all as specified and as directed. Note: earth work, Pole coping PCC, cable protection, pipe measured separately
15Supply & fixing Flood Light fitting LED 350 watt incl dismantling taking down unsv one complete all as specified and directed.
16Supply & fixing Flood Light fitting LED 250 watt incl dismantling taking down unsv one complete all as specified and directed.
17Supply & Fixing street Light fitting LED 150 watt incl dismantling taking down unsv one complete all as specified and directed.
18Supply & FixingStreet light LED 100 watt incl dismantling taking down unsv one complete all as specified and directed.
19Supply only power contactor 3 phase, 415V, 32 amps cap utilsed for heavy duty by taking down the old perished / deteriorated contactor complete all as specified and as directed. Make: Schneider, Model-ETVS-LC1E3201 or equivelent of Legrand/L&T/ABB
20Supply only MCB, SP, 10KA, "C" 6-32 A including dismantling taking down unsv one complete all as specified and as directed. Make:- Schneider or equivelent of Legrand/ABB /L&T
21Supply only MCB, DP, 10KA, "C" 32 A including dismantling taking down unsv one complete all as specified and as directed. Make:- Schneider or equivelent of Legrand/ABB /L&T
22Supply only MCB, 4P, 10KA, "C" 40A-63 A including dismantling taking down unsv one complete all as specified and as directed. Make:- Schneider or equivelent of Legrand/ABB/L&T
23Supply only MCCB with thermal magnetic release, 18 KA, 3 pole, 415V, 16A to 100 A, complete all as specified and as directed. Make:- Schneider , Model- Easy compact CVS 100 BS, LV510950 to 58 or equivelent of Legrand/ABB/L&T
24S&F on wall/pole timer enclosure complete with timerAnalog time switchesheavy duty of 230 V 50Hz,power contactor 3 phase MNX 18 , 415V, 32 amps, MCB, TPN, 10KA, "C" 40A-63 A with, rotary switch with connector for incoming and outgoing cable entry including taking out old one complete all as specified and as directed. Make Indo Asian/Havells
25Supply & fixing Building Security Light fitting LED 30watt with necssary electrial connections incl dismantling taking down unsv one complete all as specified and directed.
26Supply & fixing Building Security Light fitting LED 60watt with necssary electrial connections incl dismantling taking down unsv one complete all as specified and directed.
27Attending electrical complaints and call on repair of control panel of street light, security light, garden light, perimeter light, tower light & high mast light providedinsideDockyard, decarbonizing all contact points of contactors , replacement of wornout aluminium cable lugs, wornout screws, nuts, bolts and washers, tightening the loose connections whereever required, adjustment of timer, cleaningand restore the power supply complete all as specified and as directed. Note : (i) Replacement of spares vizMCB, MCCB, contactors, timers, cables, will be measured and paid for separately as supply only and labour element for taking down the replaced spares shall be deemed to include in the unit rate quoted. (ii) If the qty of complaints to be attended in a control panel/LT panel is more than 01 No in a day, altogether the complaints will be considered only 1 (one). (iii) The contractor has to engage qualified electricians and helpers in sufficient Nos to attend and rectify the defects.
28M&L earthing with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25 m deep below ground level with top edge of the plate not less than 1.5 m below normal ground level connected to GI strip32x6 mm by means of nuts, bolts check nuts, washers of galvanised iron or steel all as shown in electrical plate No:5 of SSR Part I connected to earth test point including excavation work with precasted pcc earth pith chamber and cover with GI protection pipe 40 mm dia light gde upto 7.5 mtr/20 mm dia tunnel pipe med grade but all as specified and directed.
29M&L for Dismantling old LT panel carefully and supply, installation, testing and commissioning of Floor mounted cubical/trunk type Outdoor made out of 3 mm thick CRCA steel sheet traded and powder coated, prewired, factory made , with provision for one incoming and multiple outgoing as mentioned below, with suitable CT"s, individual compartmentdust and vermin proof, weather proof electrical panel and with Godrej type lock, cable glands etc. and consisting of the following all as specified and as directed :- (i) Electrolytic aluminium Bus bar of capacity 600 Amps for phases and 400 Amps neutral. (ii) MCCB 400 Amps 4 pole 36KA as incommer-01 Nos. (iii) MCCB 100 Amps 4 pole 16KA as outgoing- 06 Nos (iv) MCB TPN 63A 25KA as outgoing - 02 (v) Digital Ammeter 0-2000 Amps-01 Nos . (vi) Digital voltmeter 0-500 Volts-01 Nos . (vii) Indication lamps RYB -03 sets.
30Note : (i) Drawing for LT panel showing layout of incoming and outgoing switch gear with capacity before errection shall be approved by Engr-in-Charge. (ii)Unit rate quoted include for necessary grouting / chipping of concrete and Anchor fastners and providing necessary PCC foundation to fix the LT Panel enclosure.(iii) quoted rate are Inclusive of aluminum bus bar & switchgears.
31Taking down unserviceable solar light fittings and call on repair of all in-one compact fittings and refixing the same after replacenment of LiFepo4Bty, change controller, DC driver, panel, sensor provided inside dockyard, thightening all screws, nuts, bolts, waher or replace wherever required proper cleaning of Solar panel/fittings carefully complete all as specified and directed.
32Supply only 12.8 V, 42Ah (BIS Cert) battery (LiFePo4) suitable for existingunserviceable all in one solar street light fittings (SUNSOKO) etc all as specified and directed.
33Supply only charge controller MPPT buck type suitable for existing unserviceable all in one solar street light fittings (SUNSOKO)etc all as specified and directed.
34Supply only LED DC-DC driver suitable for Unsv all in one solar street light fittings (SUNSOKO) etc., all as specified and directed.
35Supply only PIR type dusk down sensar suitable for existing unserviceable all in one solar light fittings (SUNSOKO) etc., all as specified and directed.
36Supply only solar panel 75W (-0/+4W) Mono type copact & fully intigrated designed reust proof AI housing suitable for unsv all in one solar street light fittings (SUNSOKO) etc all as specified and directed.
37Taking down unserviceablesolar light fittings and Supply & fix in repair all in one LED Solar street light fittings 60 watts having solar panel 75W (0/+4W) Mono type compact & fully intigrated designed rust proof AI housing , LED DC driver , PIR type sensor, 600K, IP 65 complete with all fixing material or as specified and directed. Make :- Bajaj SUNSOKO AIO- BSZSL 75L LED (114405) or equivalentin Havells/ Philips.
38M&L for preparation of old painted surface of exiting solar light pole of 60 mm dia of 6M height by removing all dirt, dust, with two coat of synthetic enamel paint and marking the pole number of approved color all as specified and directed.
39M & L for PCC 1: 3:6 type C-1 with 20mm graded stone agregate in copping icluding necessary from work all as directed by Engr-In-Charge.
40M&L for white wash for coping of solar street light pole by removing all dirt, dust complete all as directed by Engr-in-Charge.