Amber Development And Management Authority-ADMA has published Tender For Comprehensive Annual Operation And Maintenance Of Hvac, Ac, Ahu, Air Curtain, Ro And Water Coolers Installed At Various Monuments At Jaipur. Submission Date for this Tender is 26-09-2023. Air Conditioner Tenders in jaipur Rajasthan. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Based on PWD BSR- 2013 & 2022 (Electrical) |
2 | Providingexperienced and Highly skilled/skilled/ semi-skilled/Un Skilledlabour for electric repair/ maintenance / operation of Air conditioning/Air cooling/Fire fighting/Lift/DG set/CCTV/EPABX or any other electromechanical systems as per requirement (one shift of 8 Hrs per day for 26 Working Days in a month) |
3 | Highly skilled Labour |
4 | All in all comprehensive maintenance of various type airconditioners After Defect Laibility Period of Equipment including repair / replacement of compressor, condensing/ cooling coil , refrigerant, piping , fan motor , remote , charging of refrigerant when ever required and periodical servicing as per OEM"s recommendations to meet out the efficient performance of the equipment. |
5 | 1.5/1.8/2.0 Tr Split type air conditioner |
6 | 2.2/3.0/3.6/4.2 Tr Floor Standing Tower Type Split AC |
7 | All in all comprehensive maintenance ofWater cooler after Defect Laibility Period of Equipmentincluding compressor, condensing/ cooling coil ,water tank with inner pipingincluding repair / replacement of components , charging of refrigerants when ever required , cleaning , servicing etc as per OEM"s recommendations to meet out the efficient performance of the equipment. |
8 | Water Chiller of capacity 1200 Ltrs/hr cooling Capacity and 500 Ltrs Storage Capacity |
9 | 150/400 Ltr to 225/400 Ltr capacity |
10 | 150/150 Ltr capacity |
11 | Up to 60/120 Ltr capacity |
12 | Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR . |
13 | 1.5 TR ISEER not less then 3.8 |
14 | Supply, installation, testing and comissioning ofinterconnectingcopperrefrigerant pipingof DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink MarkBrand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified "Class O" in Fire Propagationas per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR . |
15 | 12.7 mm O.D., wall thinkness = 0.8mm (insulation – 13 mm thick) |
16 | 9.5 mm O.D., wall thinkness = 0.8mm (insulation – 13 mm thick) |
17 | Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR . |
18 | 20 mm |
19 | Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR . |
20 | 4 kVA |
21 | Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia |
22 | 50 mm dia per running inch length |
23 | Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR . |
24 | Supply & fixing MS powder coated stand suitable for 2.5/3.0/4.0 Tr outdoor type of Split/Ductable/Tower AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR . |
25 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured Coppercable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withelectrolytic gradeCopper made of copper rodsconfirming to IS 613-1964, of purity >99.7 %,Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) includingtesting etc. as required of following size. OEM must have it"s own in house NABL accrediated Laboratory for testing procedure as per IS:10810 For additional technical parameters of product / work refer Annexure "A" attached with this BSR |
26 | 4.0 Sq. mm |
27 | 3 core |
28 | Part B NON BSRItems |
29 | Comprehensive Annual maintenance of existing centralized HV Air conditioning System, AHU, Air Curtains etc. installed at Central Museum Albert Hall, as per special terms and condition of Tender documents. |
30 | Comprehensive Annualmaintenance of Existing Airconditioning systems (Daikin make, A14 HP VRV model)at Interpretation centre of Jantar Mantar, as per special terms and condition of Tender documents. |
31 | ComprehensiveAnnual Maintenance of ROs and Water coolers installed at various monuments /museums of Jaipur under AD & MA, Jaipur as perlist of ROs / Water coolers enclosed and as per special terms and condition of the tender document. |
32 | RO 250LPH & above Sizes .,Eureka Forbes make |
33 | RO Upto 50LPH.Eureka Forbes/ Aquaguard make |