Military Engineer Services-MES has published Tender For Repair To Drain Walls Culverts Replacement Of Fencing Posts Barbed Wire Chain Link Fencing And Other Misc Works At Alhilal Mil Stn. Submission Date for this Tender is 14-10-2023. Drainage Tenders in Kangra Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

39683562
Corrigendum : Tender For Repair To Drain Walls Culverts Replacement Of Fencing Posts Barbed Wire Chain Link Fencing And Other Misc Works At Alhilal Mil Stn
Open Tender
Indian
Himachal Pradesh
Kangra
14-10-2023

Tender Details

Repair To Drain, Walls, Culverts, Replacement Of Fencing Posts, Barbed Wire / Chain Link Fencing And Other Misc Works At Alhilal Mil Stn; 1 Demolition Of Reinforced Cement Concrete Of Any Description And In Any Position Not Otherwise Specifically Provided For, Complete All As Specified And Directed. 2 M&L Rcc 1:2:4 Type B-1 ( Using 20Mm Thick Crushed Stone Aggregate ) As In Cover Slab, Slab Supported On Walls / Baffle Wall, Beams And Columns In Floors, Roofs, Landings, Balconies, Canopies, Deck Slabs And In Shelves And The Like Complete All As Specified And Directed. 3 Formwork To Soffits Of Suspended Slabs Such As Roof Slabs, Floor Slabs, Landings And Similar Work; Not Exceeding 200Mm Thick ( Horizontal Or Sloping ) Complete All As Specified And Directed. 4 M&L Formwork To Edges Of Concrete Flats, Treads, Breaks In Floors, Window Cills, Concrete Railings, Opening In Concrete Walls, Floor And Roofs Not Exc 20Cm Wide And Sides Of Rcc / Pcc Bands In Walls, Horizontal Or Sloping And Similar Work Exc 10Cm But N Exc 20Cm Wide Complete All As Specified And Directed. 5 S&F Mild Steel Tmt Bars 10Mm Dia And Over, Cut To Length, Bent To Shape Required, Including Cranking, Bending Spirally For Hooping For Columns, Hooking Ends And Binding With And Including Mild Steel Wire ( Annealed ) Not Less Than 0.9Mm Dia Or Securing With Clips Complete All As Specified And Directed. 6 M&L Pre-Cast Cement Concrete Type B-1 1:2:4 ( 20Mm Graded Crushed Stone Aggregate ) As In Landings, Cover Slabs For Man Holes, Chullah Hoods, Chajjas, Water Troughs, Mangers, Shelves And Similar Articles With Plain Faces, Set In Cm 1:4 Complete All As Specified And Directed. 7 Demolition Ofbrickwork Or Stone / Boulder Masonry Built In Cement Mortar Or Cement Lime Mortar Including All Quoins, Arches, Pillars, Etc But Excluding Ashlar Facing, Dressed Stone Work Precast Concrete Articles Complete All As Specified And Directed. 8 M&L Walling Of Random Rubble Stone Masonry Uncoursed, Brought Upto Course With Best Quality Locally Available Harder Stones Such As Granite, Trap, Basalt Stone Etc. Well Bonded, Bedded And Solidly Hearted, Built In Cm 1:6 Complete All As Specified And Directed. 9 All As Per Item No. 08 Above But Except Stone.Note: Old Stone Obtained From Demolition Shall Be Used. 10 Extra Over Stone Walling ( Granite Or Trap Stone ) For Hammer Dressingwith Maximum Depression On Face From A Straight Edge Held Against The Dressed Surface N Exc Exceeding 40Mmand Dressing To Face Beds And Joints As Specified Of Random Rubble Walling Un-Courses Or Brought Upto Coarse Complete All As Specified And Directed. 11 M&L Plain Cement Concrete 1:2:4 Type B-1 Using 20 Mm Graded Stone Aggregate Cast In Situ In Lintels Up To 1.5 M Clear Span, Cills, Steps, Seismic And Other Similar Bands, Plinth Courses, String Courses, Lacing Courses, Parapets And Railings Up To 60 Cm In Height, Copings, Kneelers, Apex Stones, Bed Plates, Water Through And The Like Including Weathering, Slightly Rounded Or Chamfered Angles And Throating Including Use Of Form Work ( Straight Or Curved ) Complete All As Specified & Directed. 12 M&Lraised Pointing To Random Or Polygonal Rubble Stone Masonry, Un-Courses Or Brought Upto Course In Cement Mortar 1:4 Complete All As Specified And Directed. 13 Flush Pointing To Random Or Polygonal Rubble Stone Masonry, Un-Courses Or Brought Upto Course In Cement Mortar 1:4 Complete All As Specified And Directed. 14 Supply Only Pvc ( Swr ) Pipes 110Mm Bore, Single Socketed, In Any Length As In Wheep Holes Etc. Complete All As Specified And Directed. 15 Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding But Not Backing, Removing Serviceable Tiles To Store And Rubbish Off The Premises, Complete All As Specified And Directed. 16 M&L Glazed Ceramic Coloured Tiles In Vertical Surface 350Mm X 250Mm X 7Mm / 450Mm X 350Mm X 7Mm / 450X300x7mm / 600X300x7mm Thick Set And Jointed In Neat Cement Slurry, Pointed In White Or Coloured Cement To Match The Colour Of Tiles, Over And Including 10Mm Thick Backing Coatin Cm 1:4 To Receive Tiles, Complete All As Specified And Directed. 17 Demolition Of Cement Concreteunreinforced In Ground Floors, Kota Stone, Granite Flooring, Tiles Flooring AndpavingSnot Exceeding15cm Thickness ( Below Or Above Ground Level ) And Removal Unserviceable Materials, Debris And Rubbish To A Distance Not Exceeding 100M Complete All As Specified & Directed. 18 M&L Pcc 1:5:10 Type E-2 ( Using 40Mm Graded Crushed Stone Aggregate ) In Foundations, Filling And Mass Concretecomplete All As Specified And Directed. 19 M&L Pcc 1:3:6 Type C-2 ( Using 20Mm Graded Crushed Stone Aggregate ) As In Surface Channel Or Drain Etc. Complete All As Specified And Directed. 20 M&L Extra For Forming Fair Finished Drain Or Channel 30Cm Inner Girth In Cement Concrete, Using Extra Cement, Including Forms, Moulds, Mi- Tred / Stopped Ends Etc. Complete All As Specified And Directed. ( Inner Girth Only Measured ) 21 Taking Down Cement Plaster Of Any Description On Brick Or Stone Or Cement Concrete Block Walls Etc Including Raking Out Joints, Hacking For Key, Scrubbing Down With Water Etc, And Removal Of Rubbish Off The Premises And Leave The Work Clear Of Any Plasteringcomplete All As Specified And Directed. 22 M&L Rendering 15Mm Thickplaster In Cement Mortar ( 1:4 ) On Fair Faces Of Brick Work Or Concete Surfaces, Finished Even And Smooth Without Suing Extra Cement Complete All As Specified And Directed. 23 Rendering 10Mm Thick Plaster On Fair Faces Of Concrete Surfaces As In Facia Or Ceiling In Cement Mortar 1:3 Finished Even And Smooth Without Using Extra Cement, Complete All As Specified And Directed. 24 M&L Preparingnew Plastered Or Un-Plastered Surfaces Of Walls And Applying Two Coats Of Cement Base Paint Over A Coat Primercomplete All As Specified & Directed. 25 Dismantlingwrought Iron Or Mild Steel Work Of Any Description Not Other Wise Provided For Complete All As Specified And Directed. 26 S&F Rolled Mild Steel Sections Like Angle, Channel, Flat Etc As Inframed Work Such As Grills, Gratings, Etc, With Ends Of Bars Shouldered And / Or Riveted, Or Forged Into Spikes, Framed Guard Bars; Barred Iron Doors; Ladders ; Framed Balusters; Walk Ways; Railings; Framed Work Of Water Tanks And Similar Work Confirming Tofe-290Gde E-165 Complete All As Specified & Directed. 27 All As Per Item No. 25 Above But Erection And Fixing Only. 28 M&Lpreparing New Surface Of Steel Of Any Description, Over 10Cm Width Or Girth Not Other Wise Described And Appliying Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide, Zinc Chrome Primer, Complete All As Specified And Directed. 29 Providing And Laying At Or Near Ground Level Factory Made Kerb Stone Of M-25 Grade Cement Concrete In Position To The Required Line, Level And Curvature, Jointed With Cement Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) , Including Making Joints With Or Without Grooves ( Thickness Of Joints Except At Sharp Curve Shall Not To More Than 5Mm ) , Including Making Drainage Opening Wherever Required Complete All As Specified And Directed. 30 M&L 75Mm Thick Pcc 1:4:8 Type D-2 Using 40Mm Graded Crushed Stone Aggregate As In Sub Base Of Paver Block / Chequered Tile Complete All As Specified And Directed. 31 M&L 50Mm Sand Filling Under Floors Or In Foundations Including Watering And Consolidation Complete All As Specified And Directed. 32 M&L 80 Mm Thick Rubber Moulded Coloured Machine Pressed Precast Concreteinterlocking Paver Block Any Shape And Size ( Shape As Approved Bt Ge ) Laid In Path, Porch, Hard Standing Or Flooring Etc Conforming To Is-15658-2006, M-40 Grade Over And Including 25 Mm Thick Layer Of Sand Cushioning, Complete All As Specified And Directed . 33 M&L 30Cm X 30 Cm X 25Mm Thick, Coloured Rubber Moulded Chequered Cement Concrete Tiles With Grey Cement And Pigment Set And Jointed In Neat Cement Slurry And Pointed With White Or Coloured Cement To Match The Colour Of Tiles Over And Including 15Mm Thick Screed Bed Or Bedding Layer In Cm 1:6 Complete All As Specified And Directed. 34 Cleaning Away All Grass, Vegetation, Saplings, Shurbs, Bruswoods, Undergrowth, Roots And Trees Not Exc. 30Cm Girth ( Measured One Meter Above Ground Level ) And Removing Rubbish Upto Distance Of 50 Meter Outside The Periphery Of The Area Udner Clearance Complete All As Specified And Directed. 35 Dismantling Posts Or Struts ( Wood, Steel Or R.C.C ) Any Section, Including Taking Out Embedded Portion And Making Good Disturbed Ground Or Lean Concrete Etc. And Making Good Disturbed Portion Complete All As Specified And Directed. 36 Excavation Post Holes ( Or Similar Holes ) In Any Type Of Soil Each N Exc 0.50 Cu.M, Getting Out, Returning, Filling On And Ramming Earth Or Broken Rubble Mixed With Earth Around, In Layers Not Exceeding 25Cm, Complete All As Specified And Directed. 37 M&L Pcc 1:3:6 ( Nominal Mix ) , Type C-2 ( Using 20Mm Thick Crushed Stone Aggregate ) As In Foundation, Filling And Mass Concrete Etc. Complete All As Specified And Directed. 38 S&F Hand Rails, Half Round Or Other Steel Section Or Core For Wooden Hand-Rail Straight Portion, Drilled And Countersunk For Balusters Running Bars, For Doors, Balusters, Nosing To Steps Including Embeding In Concrete And Screweing Etc. Wind Ties For Roof Including Securing Bolts; Posts And Struts In Fencing Including Cutting Tops To Shape As Directed, Dilling Holes, Notching For Wire. Etc.; Flat Iron Fillets ( For Securing Wire Mesh Etc. ) Including All Necessary Drilling, Holting Or Riveting, Etc., And Similar Work Conforming To Fe-290 Gde E-165 Complete All As Specified And Directed. 39 S&F Galvanised, 2 Strand, Steel Barbed Wire 2.24Mm Dia Barbed With 2Mm Dia Barbs At 75Mm Spacings And Straining And Fixing To Any Type Of Standard Rails Straining Bolts, Including, Securing Or Tying At Crossings With And Provision Of Galvanised Mild Steel Wire, Staples Or Steel Pins, Etc. As Directed ( Each Line Wire To Be Measured ) Complete All As Specified And Directed. 40 Restraining And Resecuring Including Making Good Staples And Typing With Mild Steel Binding Wire ( Whenever Required ) Etc. In Existing Barbed Wire Fencing Of Any Description Complete All As Specified And Directed. 41 Mild Steel Galvanized, Chain Link Fencing Size Or Any Type Wt 3 To 4 Kg Per Sqm, Complete All As Specified And Directed. 42 Fixing Only Chain Link Fencing Including Line Wires, Any Mesh, Size And Type To Any Type Of Standards, Rails, Straining Bolts, Etc. Including Provision Of Binding Wire Complete All As Specified And Directed. 43 Mild Steel Screw Bolts ( Machine Made ) With Hexagonal Or Squire Heads At One End And Screwed The Other Ends, Or Screwed Both Ends Each Screw To Be Fitted With Washer And One Hexagonal Or Square Nuts, Length Of Bolt Not Exceeding 25Mm Long, Diameter Of Shank 12Mm, Complete All As Specified And Directed. 44 Preparation Of New Steel Surfaces Of Any Description Two Coat Of Black Bituminous Paint Wood, Steel, Iron, Concrete, Brick, Stone, Etc. Exceeding 10Cm In Width Or Girth Complete All As Specified And Directed.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 23-Sep-2023 Amendment BOQ 07-10-2023
2 07-Oct-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 14-10-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 80000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIR TO DRAIN, WALLS, CULVERTS, REPLACEMENT OF FENCING POSTS, BARBED WIRE/CHAIN LINK FENCING AND OTHER MISC WORKS AT ALHILAL MIL STN
Sl. No. Item Description
1Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for,complete all as specified and directed.
2M&L RCC 1:2:4 type B-1 (using 20mm thick crushed stone aggregate) as in cover slab, slab supported on walls/baffle wall, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
3Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
4M&L formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, opening in concrete walls, floor and roofs not exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed.
5S&F mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
6M&L pre-cast cement concrete type B-1 1:2:4 (20mm graded crushed stone aggregate) as in landings, cover slabs for man holes,chullah hoods,chajjas,water troughs,mangers,shelves and similar articles with plain faces, set in CM 1:4 complete all as specified and directed.
7Demolition ofbrickwork or stone/boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facing, dressed stone work precast concrete articles complete all as specified and directed.
8M&L walling of random rubble stone masonry uncoursed, brought upto course with best quality locally available harder stones such as granite, trap, basalt stone etc. well bonded, bedded and solidly hearted, built in CM 1:6 complete all as specified and directed.
9All as per item No. 08 above but except stone. Note: Old stone obtained from demolition shall be used.
10Extra over stone walling(Granite or trap stone)for hammer dressingwith maximum depression on face from a straight edge held against the dressed surface n exc exceeding 40mmand dressing to face beds and joints as specified of random rubble walling un-courses or brought upto coarse complete all as specified and directed.
11M&L plain cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate cast in situ in lintels up to 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates, water through and the like including weathering, slightly rounded or chamfered angles and throating including use of form work (straight or curved) complete all as specified & directed.
12M&Lraised pointing to random or polygonal rubble stone masonry,un-courses or brought upto course in cement mortar 1:4 complete all as specified and directed.
13Flush pointing to random or polygonal rubble stone masonry,un-courses or brought upto course in cement mortar 1:4 complete all as specified and directed.
14Supply only PVC (SWR) pipes 110mm bore, single socketed, in any length as in wheep holes etc. complete all as specified and directed.
15Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing, removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed.
16M&L Glazed ceramic coloured tiles in vertical surface 350mm x 250mm x 7mm/450mm x 350mm x 7mm/450x300x7mm/600x300x7mm thick set and jointed in neat cement slurry,pointed in white or coloured cement to match the colour of tiles, over and including 10mm thick backing coatin CM 1:4 to receive tiles,complete all as specified and directed.
17Demolition of cement concreteunreinforced in ground floors, kota stone, granite flooring, tiles flooring andpaving"snot exceeding15cm thickness (below or above ground level) and removal unserviceable materials, debris and rubbish to a distance not exceeding 100m complete all as specified & directed.
18M&L PCC 1:5:10 type E-2 (using 40mm graded crushed stone aggregate) in foundations,filling and mass concretecomplete all as specified and directed.
19M&L PCC 1:3:6 type C-2 (using 20mm graded crushed stone aggregate) as in surface channel or drain etc. complete all as specified and directed.
20M&L extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mi- tred/stopped ends etc. complete all as specified and directed.(inner girth only measured)
21Taking down cement plaster of any description on brick or stone or cement concrete block walls etc including raking out joints, hacking for key, scrubbing down with water etc, and removal of rubbish off the premises and leave the work clear of any plasteringcomplete all as specified and directed.
22M&L rendering 15mm thickplaster in cement mortar(1:4) on fair faces of brick work or concete surfaces, finished even and smooth without suing extra cement complete all as specified and directed.
23Rendering 10mm thick plaster on fair faces of concrete surfaces as in facia or ceiling in cement mortar 1:3 finished even and smooth without using extra cement, complete all as specified and directed.
24M&L preparingnew plastered or un-plastered surfaces of walls and applying two coats of cement base paint over a coat primercomplete all as specified & directed.
25Dismantlingwrought iron or mild steel work of any description not other wise provided for complete all as specified and directed.
26S&F rolled mild steel sections like angle, channel, flat etc as inframed work such as grills, gratings,etc,with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders ; framed balusters; walk ways; railings; framed work of water tanks and similar work confirming toFe-290Gde E-165 complete all as specified & directed.
27All as per item No. 25 above but erection and fixing only.
28M&Lpreparing new surface of steel of any description, over 10cm width or girth not other wise described and appliying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer, complete all as specified and directed.
29Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete all as specified and directed.
30M&L 75mm thick PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in sub base of paver block/chequered tile complete all as specified and directed.
31M&L 50mm sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
32M&L 80 mm thick rubber moulded coloured machine pressed precast concreteinterlocking paver block any shape and size (shape as approved bt GE) laid in path,porch,hard standing or flooring etc conforming to IS-15658-2006, M-40 grade over and including 25 mm thick layer of sand cushioning, complete all as specified and directed .
33M&L 30cm x 30 cm x 25mm thick, coloured rubber moulded chequered cement concrete tiles with grey cement and pigment set and jointed in neat cement slurry and pointed with white or coloured cement to match the colour of tiles over and including 15mm thick screed bed or bedding layer in CM 1:6 complete all as specified and directed.
34Cleaning away all grass, vegetation, saplings, shurbs, bruswoods, undergrowth, roots and trees not exc. 30cm girth (measured one meter above ground level) and removing rubbish upto distance of 50 meter outside the periphery of the area udner clearance complete all as specified and directed.
35Dismantling posts or struts (wood, steel or R.C.C) any section, including taking out embedded portion and making good disturbed ground or lean concrete etc. and making good disturbed portion complete all as specified and directed.
36Excavation post holes (or similar holes) in any type of soil each n exc 0.50 cu.m,getting out,returning,filling on and ramming earth or broken rubble mixed with earth around,in layers not exceeding 25cm, complete all as specified and directed.
37M&L PCC 1:3:6 (Nominal mix), type C-2 (using 20mm thick crushed stone aggregate) as in foundation, filling and mass concrete etc. complete all as specified and directed.
38S&F hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars,for doors, balusters, nosing to steps including embeding in concrete and screweing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, dilling holes, notching for wire. etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, holting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
39S&F galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and directed.
40Restraining and resecuring including making good staples and typing with mild steel binding wire (whenever required) etc. in existing barbed wire fencing of any description complete all as specified and directed.
41Mild steel galvanized, chain link fencing size or any type wt 3 to 4 kg per sqm, complete all as specified and directed.
42Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed.
43Mild steel screw bolts (machine made) with hexagonal or squire heads at one end and screwed the other ends, or screwed both ends each screw to be fitted with washer and one hexagonal or square nuts, length of bolt not exceeding 25mm long, diameter of shank 12mm, complete all as specified and directed.
44Preparation of new steel surfaces of any description two coat of black bituminous paint wood, steel, iron, concrete, brick, stone, etc. exceeding 10cm in width or girth complete all as specified and directed.