Public Administrative Department Local Bodies Closing in 0 days TDR #39670926

Tender For Permanent Lighting Arrangement At Under Concourse Level Street Light Of Nicco Park Metro Station Under Ndita Area.

Issued by Local Bodies · ndita, West Bengal
Tender Value
10.72 Lakhs
Estimated cost
Bid Submission
29 Sep 2023
0 days left
EMD
21457
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
ndita → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Permanent Lighting Arrangement At Under Concourse Level Street Light Of Nicco Park Metro Station Under Ndita Area.

BOQ

Name of Work: Permanent lighting arrangement at under concourse Level Street light ofNicco ParkMetro Station under NDITA area.
Sl. No. Item Description
1Supplying of25 Sqmm, 4 Core XLPEinsulated Aluminium conductor armoured cables of 1.1KV grade as per IS 7098 (Part.1) 1988 Size: 25 Sqmm, 4 Core
2Supplying of10 Sqmm, 4 Core XLPEinsulated Aluminium conductor unarmoured cables of 1.1KV grade as per IS 7098 (Part.1) 1988 Size: 10 Sqmm, 4 Core
3Laying of one No. cable upto 35 Sqmm. In underground trench 460mm wide x 760mm average depth. With brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, levelling up and restoring surface duly rammed.
4Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & FMS saddles with earthing attachment in 10 SWG GI (Hot Dip)Wire, making holes etc. as necy. mending good damages and painting
5Supply of High Density Poly-ethylene Pipe conforming to IS - 4984 - 1985(Dia) [PE - 63]A. 6 Kg / Sq.Cm. (Working Pressure)Dia - 50mm
6Labour for fitting and fixing high density poly-ethylene pipes or P.V.C. pipes for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineer-in-charge. (Payment will be made on centre line measurement of the total pipeline including specials. )(B)Under Ground(vi) 50 mm dia.
7Supplying and fixing medium gauge GI Pipe (ISI-Medium) Protection with necessary fittings and jointing metarials as required of size 80mm dia.
8Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring or dust & moisture-proof entry of XLPE/PVC armoured cables.Size: 10 sqmm, 4 core.
9Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring or dust & moisture-proof entry of XLPE/PVC armoured cables.Size: 25 sqmm, 4 core.
10Finishing the end of following XLPE/PVCarmoured cables by crimping method including supplying and fixing solderless socket (Dowels make), taps, anticorrosive paste & jointing materilas.i) 4 core, 10 Sqmm.
11Finishing the end of following XLPE/PVCarmoured cables by crimping method including supplying and fixing solderless socket (Dowels make), taps, anticorrosive paste & jointing materilas.i) 4 core, 25 Sqmm.
12Connecting the equipments to earth busbar including S & F GI(Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. asrequired and mending good damages(a) Solid GI wire(iv) No. 10 SWG
13Supply & fixing M.S. loop box (10 SWG) of size 269 x 219 x 125mm having almirah type cover complete with special type locking arrangement including supply & fixing 200mm x 150mm x 6mm backlite sheet 1 No. 4-way ebonite connector block. 1 No. 15 Amp fuse unit (BPC/Juvas/ Havells make) fitted inside the box and suitable size danger board riveted on cover of the box outside & fixing the box with pole by means of M.S.Clamps of 25mm x 6mm of suitable length and encasing the box by 1:2:4 cement concrete with graded stone chip (19mm down). The depth of the concrete should be 60cm x 45cm x 45cm including Plasteringand neat cementing and supply & fixing 2Nos compression gland of suitable size and making all necessary connection as required.
14Supplying and fixing 240/415V MCB of Breaking Capacity 10KA & C characteristics on din rail of existing DBs and necessary connection.6-32A (SP), Make: Legrand/seimens/Schneider
15Supplying and drawing 1.1KV Single Core stranded \"FR\" PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necessary connection as required from terminal box at Bottom end to the respective LED fittings.1.b) 3 x 22/0.3(1.5 sqmm.)
16Supply and fixing of greenline V2 street light (115 watt) complete with all accessories to be fixed/ projected from the wall of the building or on pole incl. making holes/providing Clamping arrangement & necy. GI reducer as required. S&F 40mm GI pipe (ISI- Medium) quality 1.5 mts. Average length having suitable bend S&F necy. length 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending gooddamages to wall incl. painting etcMake:- Philips, pansonic, Bajaj, Crompton
17Supplying & Erection of big size feeder pillar box of Size (1372 x 914 x 607 mm) made up of 3.15 mm thick MS Plate along with suitable M.S. Angle. The P.B. have double hinge door at the front & back with suitable locking arrangement. The box will be painted by 2 cores of aluminiam paint over 1 coat of red oxide paint. Suitable arrangement should be provided for fixing of Timer unit, fuse unit & other accessories. Leg of the pillar box will be 900 mm in length by made up of (35x35x3 mm MS Angle with suitable base Plate. Legs of the Pillar box will be erected at 300 mm below the ground level with cement concrete (6:3:1). Rest portion coverd by 5\" Brick Wall with plastering & net cement & bottom portion filled with silver sand as drawing & direction of E.I.C.
18Supplying of Bakelite Sheeta) 3 mm thick
19Supply and Fixing of fuse unit complete with base and bridge on existing Board and necessary connection, for the following range.e)100 Amp., 415 V
20Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – (As per Drawing no. 470 of PWD Specification Book – May 1991)4 bars 415V 200A X 50 X 5 mm
21Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection.100 AMake: Legrand/Siemens/Schneider
22Supplying and fixing 240/415V MCB of Breaking Capacity 10KA & C characteristics on din rail of existing DBs and necessary connection32A(FP)Make: Legrand/seimens/Schneider
23Supplying and drawing 1.1KV Single Core stranded \"FR\" PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necessary connection at Feeder piller box.1.o) 4 x 80/0.4 (10 sqm)
24Supply and delivery of Electronic Timer suitable for 240/ 360/ 415V, 50 Hz(Make: L&T/ABB/Schneider/Simence/GE/Minilic) of the following time (Second) range:b) 12.0 to 120.0
25Supply and fixing of 240/230 volt, 50 Hz, T.P., powercontactor (Make: L & T/ABB/Schneider/Simence/ GE) havingcontact block of the following range.g) 50-85Amp
26Supply and delivery of Thermal overload relays(Make: L & T/ABB/Schneider/Simence/ GE/Minilec) of thefollowing range:j) 30-50, MN5
27Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:(a) By ISI-Medium GI pipe
28Excavation of soil for installation of Earth Electrode and filling & ramming.(a) For Soft Soil
29Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe.
30Add GST@18% on Sl. No. 1 to 29
31Add labour cess @1% on Sl. No. 1 to 30

AI Tender Summary

OUR REF NO 39670926
AUTHORITY Local Bodies
TENDER VALUE 10.72 Lakhs
LAST DATE 29-09-2023
Authority
Authority Name Municipal Affairs Department
Work Description Tender For Permanent Lighting Arrangement At Under Concourse Level Street Light Of Nicco Park Metro Station Under Ndita Area.
Basic Detail
Tender No WBMAD/NDITA/44/2023-24
Bidding Type Tender
Location
City ndita
State West Bengal
Key Dates
Publish Date 14 Sep 2023
Submission Date 29 Sep 2023
Open Date 03 Oct 2023
Finance
Tender Value 10.72 Lakhs
Tender Fee Ref. Documents
EMD 21457
Exemption Not Available
Document List
4bf4a25f-ab80-4427-906e-17f10a1ac20c.html
BOQ_1188484.xls
FORM1C.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 14, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 29, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Oct 03, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

4bf4a25f-ab80-4427-906e-17f10a1ac20c.html

xls

BOQ_1188484.xls

pdf

FORM1C.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders