Supply, Installation, Testing And Commissioning Ofstrong Motion Accelerograph, Broad Band Seismograph & Communication System At Idamalayar, Sholayar And Poringalkuthu, Ernakulam-Kerala

Kerala State Electricity Board-KSEB has published Supply, Installation, Testing And Commissioning Ofstrong Motion Accelerograph, Broad Band Seismograph & Communication System At Idamalayar, Sholayar And Poringalkuthu. Submission Date for this Tender is 02-11-2023. Accelerometers Tenders in Ernakulam Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

39656131
Corrigendum : Supply, Installation, Testing And Commissioning Ofstrong Motion Accelerograph, Broad Band Seismograph & Communication System At Idamalayar, Sholayar And Poringalkuthu
Open Tender
Indian
Kerala
Ernakulam
02-11-2023

Tender Details

Supply, Installation, Testing And Commissioning Ofstrong Motion Accelerograph, Broad Band Seismograph & Communication System At Idamalayar, Sholayar And Poringalkuthu - Supply, Installation, Testing And Commissioning Of Strong Motion Accelerograph, Broad Band Seismograph And Communication System At Idamalayar, Sholayar And Poringalkuthu , For Supply Of Goods , Broad Band Seismograph ( Seismometer With Data Acquisition & Communication System, Including Software And All Components & Accessories ) For Field Stations ( Observatories ) Conforming To The Requirements Specified In Technical Specification.The System Shall Include Lightning Protection For The Observatory Building, Indoor Type Surge Protectors On Panel Board, Earthing With All Connectors As Per Relevant Standards, Etc Complete As Per Specifications , Strong Motion Accelerograph ( Accelerometer With Data Acquisition & Communication System Including Software And All Components & Accessories ) For Field Stations ( Observatories ) , Dam Crest / Free Field And Galleries Conforming To The Requirements Specified In Technical Specification.The System Shall Include Indoor Type Surge Protectors And Other Accessories Etc As Per Specifications With Necessary Weather Proof Enclosures Etc For Data Acquisition And For The Protection Of All Components. , Vsat System For Field Stations ( Observatories ) Including; • Odu ( Antenna With Transceiver ) . • Idu. • Ac Adapter. • Dc Adapter. • Ethernet Cable, Connectors Etc. Conforming To The Requirementsspecified In Technical Specification.The System Shall Include Indoor Type Surge Protectors And Other Accessories Etc As Per Specifications. , Solar Power System For Field Stations ( Observatories ) As Primary Power System Including Solar Panels, Charge Controller, Battery And All Cables, Cable Connectors, Mounting Racks, Indoor Type Surge Protection Devices And Any Other Accessories Conforming To The Requirements Specified In Technical Specification. , Secondary Power System For The Broad Band Seismographs At Field Stations ( Observatories ) Including Battery, Stabilizer, Battery Charger, Indoor Type Surge Protection Devices And Any Other Accessories, Conforming To The Requirements Specified In Technical Specification. , Secondary Power System For The Strong Motion Accelerographs At Field Stations ( Observatories ) Including Battery, Stabilizer, Battery Charger, Indoor Type Surge Protection Devices And Any Other Accessories, Conforming To The Requirements Specified In Technical Specification. , Secondary Power System For Vsat At Field Stations ( Observatories ) Including Battery, Stabilizer, Battery Charger, Indoor Type Surge Protection Devices And Any Other Accessories Conforming To The Requirements Specified In Technical Specification. , Power System For The Strong Motion Accelerographs At Various Installation Locations In Dam Crest / Free Field And Galleries By Extending Cables ( From The Main Ksebl Supply Point Including Providing A Common Control Switch At Starting Point ) Using 2.5 Mm2, 3 Core Armoured Cable With All Accessories And Including Battery For Back Up, Stabilizer & Battery Charger ( Ip 67 Rating ) With Spike Protection / Dc-Dc Converters, And Any Other Accessories, Conforming To The Requirements Specified In Technical Specification. , Desktop Computer For Control Room In Dam Safety Organisation Building, Pallom For Data Acquisition And Analysis Including Necessary Softwares And All Accessories Conforming To The Requirements Specified In Technical Specification. , Laptop For The Field ( Idamalayar, Sholayar And Poringalkuthu Field Offices ) Including Software And All Accessories Conforming To The Requirements Specified In Technical Specification. , For Related Services , Installation, Testing, Commissioning Of Broad Band Seismograph ( Seismometer With Data Acquisition& Communication System With Ksebl’S Crs Provided Etc. ) In Field Stations ( Observatories ) Conforming To The Requirements Specified In Technical Specifications, Providing Lightning Protection For The Observatory Building With Horizontal Conductors Above The Roof With Aluminium Strips 25 X 3 Mm Along The Outer Periphery Of The Building, Down Conductors And Plate Earthing At Two Locations, Providing Indoor Type Surge Protection Devices ( Spd ) On Panel Board, All Related Civil Works And Providing Necessary Training, Documentation Conforming To The Technical Specifications And Conditions Of Contract Etc Complete As Directed By The Engineer In Charge. , Installation, Testing, Commissioning Of Strong Motion Accelerograph ( Accelerometer With Data Acquisition & Communication System With Ksebl’S Crs Provided Etc. ) In Field Stations ( Observatories ) , Dam Crest / Free Field And Galleries Conforming To The Requirements Specified In Technical Specifications, Providing Indoor Type Surge Protection Devices ( Spd ) On Panel Board, All Related Civil Works, Providing Necessary Training, Documentation Conforming To The Technical Specifications And Conditions Of Contract Etc Complete As Directed By The Engineer In Charge , Installation, Testing And Commissioning Of Vsat Systemfor Field Station ( Observatory ) Conforming To The Requirements Specified In Technical Specifications, Providing Indoor Type Surge Protection Devices ( Spd ) On Panel Board, All Related Civil Works And Providing Necessary Training, Documentation Conforming To The Technical Specifications And Conditions Of Contract Etc Complete As Directed By The Engineer In Charge. , Installation, Testing And Commissioning Of Solar Power System For Field Stations ( Observatories ) As Primary Power System Including Solar Panels, Charge Controller, Battery And All Cables, Cable Connectors, Mounting Racks And Any Other Accessories Conforming To The Requirements Specified In Technical Specifications, Providing Indoor Type Surge Protection Devices ( Spd ) On Panel Board, All Related Civil Works And Providing Necessary Training, Documentation Conforming To The Technical Specifications And Conditions Of Contract Etc Complete As Directed By The Engineer In Charge. , Installation, Testing And Commissioning Of Secondary Power System For The Broad Band Seismographs At Field Stations ( Observatories ) Including Battery, Stabilizer, Battery Charger And Any Other Accessories, Conforming To The Requirements Specified In Technical Specifications, Providing Indoor Type Surge Protection Devices ( Spd ) On Panel Board, All Related Civil Works And Providing Necessary Training, Documentation Conforming To The Technical Specifications And Conditions Of Contract Etc Complete As Directed By The Engineer In Charge. , Installation, Testing And Commissioning Of Secondary Power System For The Strong Motion Accelerographs At Field Stations ( Observatories ) Including Battery, Stabilizer, Battery Charger And Any Other Accessories, Conforming To The Requirements Specified In Technical Specifications, Providing Indoor Type Surge Protection Devices ( Spd ) On Panel Board, All Related Civil Works And Providing Necessary Training, Documentation Conforming To The Technical Specifications And Conditions Of Contract Etc Complete As Directed By The Engineer In Charge. , Installation, Testing And Commissioning Of Secondary Power System For Vsat At Field Stations Including Battery, Stabilizer, Battery Charger And Any Other Accessories Conforming To The Requirements Specified In Technical Specifications, Providing Indoor Type Surge Protection Devices ( Spd ) On Panel Board, All Related Civil Works And Providing Necessary Training, Documentation Conforming To The Technical Specifications And Conditions Of Contract Etc Complete As Directed By The Engineer In Charge. , Installation, Testing And Commissioning Of Power System For The Strong Motion Accelerographs At Various Locations ( In Dam Crest / Free Field And Galleries ) Including 2.5 Mm2, 3 Core Armoured Cable, Control Switches, Battery, Stabilizer & Battery Charger ( Ip67 Rating ) With Spike Protection / Dc-Dc Converters, Providing Crossings For Cables ( Wherever Necessary ) And With All Other Accessories, All Related Civil And Electrical Works, Providing Necessary Training, Documentation Conforming To The Technical Specifications And Conditions Of Contract Etc Complete As Directed By The Engineer In Charge. , Installation, Testing And Commissioning Of Desktop Computer At Control Room In Dam Safety Organisation Building, Pallom With Necessary Softwares Etc Complete Conforming To The Requirements Specified In Technical Specifications, And Providing Necessary Training As Directed By The Engineer In Charge. , Installation, Testing And Commissioning Of Laptop With Necessary Softwares Etc Complete Conforming To The Requirements Specified In Technical Specifications, And Providing Necessary Training As Directed By The Engineer In Charge. , Integrating The Data Obtained From The Newly Added Seismic Equipments With The Existing Ksebl Network System Of Seismic Equipments And Connected Crs At Thiruvananthapuram, Making Arrangements To Obtain All Seismic Datas Received At Crs, Thiruvananthapuram In The Desktop Computer Installed At The Control Room In Dam Safety Organisation Building, Pallom Via The Seed Link Or Any Other Alternative Methods. The Work Includes Installation Of All Necessary Softwares Etc As Directed By The Engineer In Charge. , Recurring Expenditure For Vsat ( For Five Years ) , In Route: 36 Kbps Tdma In Route Bandwidth For Total Networking Including Dot & Wpc Share For Total Network. , Out Route: 16 Kbps Tdma Satellite Bandwidth Charges For Total Network Including Dot And Wpc Revenue Share And Vsat Network Monitoring Charges For Total Network. , Backhaul Connectivity: 24 Kbps Scpc Satellite Bandwidth Link Charges For Ksebl Including Dot And Wpc Revenue Share And Vsat Network Monitoring Charges For Total Network. , Camc Charges Of Entire System Including Seismic Equipment, Data Acquisition & Communication System, Maintenance Of Computers, Maintenance Related With Integration Of Data With The Crs System At Thiruvananthapuram And Obtaining All Seismic Data From Crs, Thiruvananthapuram In The Desktop Computer At Control Roomin Dam Safety Organisation Building, Pallom, Vsat System ( Including Spare Parts, Modules, Cards, Subunits, Consumables, Idu, Odu, Modem, Routers, Antennas, Cables, Connectors, Spds, Field Visit Charges, Providing Training, Repairing Charges, Transportation, Maintenance Cost Of Entire System Including That Of Related Civil Works ) Lightning Protection, Earthing And Surge Protection Etc. Completefor Year I After Warranty Period. , Camc Charges Of Entire System Including Seismic Equipment, Data Acquisition & Communication System, Maintenance Of Computers, Maintenance Related Withintegration Of Data With The Crs System At Thiruvananthapuram And Obtaining All Seismic Data From Crs, Thiruvananthapuram In The Desktop Computer At Control Roomin Dam Safety Organisation Building, Pallom, Vsat System ( Including Spare Parts, Modules, Cards, Subunits, Consumables, Idu, Odu, Modem, Routers, Antennas, Cables, Connectors, Spds, Field Visit Charges, Providing Training, Repairing Charges, Transportation, Maintenance Cost Of Entire System Including That Of Related Civil Works ) Lightning Protection, Earthing And Surge Protection Etc. Completefor Year Ii After Warranty Period. , Camc Charges Of Entire System Including Seismic Equipment, Data Acquisition & Communication System, Maintenance Of Computers, Maintenance Related Withintegration Of Data With The Crs System At Thiruvananthapuram And Obtaining All Seismic Data From Crs, Thiruvananthapuram In The Desktop Computer At Control Roomin Dam Safety Organisation Building, Pallom, Vsat System ( Including Spare Parts, Modules, Cards, Subunits, Consumables, Idu, Odu, Modem, Routers, Antennas, Cables, Connectors, Spds, Field Visit Charges, Providing Training, Repairing Charges, Transportation, Maintenance Cost Of Entire System Including That Of Related Civil Works ) Lightning Protection, Earthing And Surge Protection Etc. Completefor Year Iii After Warranty Period.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 05-Oct-2023 Corrigendum III Technical Bid 26-10-2023
2 05-Oct-2023 Corrigendum II Time Extension Date 26-10-2023
3 05-Oct-2023 Corrigendum I Technical Bid 26-10-2023
4 25-Oct-2023 Time Extension Corrigendum IV Date 02-11-2023

Key Value

Document Fees
INR 8850 /-
EMD
INR 100000.0 /-
Tender Value
INR 3.01 Crore /-

BOQ Items

Name of Work: SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OFSTRONG MOTION ACCELEROGRAPH, BROAD BAND SEISMOGRAPH & COMMUNICATION SYSTEM AT IDAMALAYAR, SHOLAYAR AND PORINGALKUTHU.
Sl. No. Item Description
1For Supply of goods
2Broad Band Seismograph (Seismometer with Data Acquisition & Communication System, including software and all components & accessories)for field stations (Observatories) conforming to the requirements specified in Technical specification.The system shall include lightning protection for the observatory building, indoor type Surge Protectors on panel board, Earthing with all connectors as per relevant standards, etc complete as per specifications
3Strong Motion Accelerograph (Accelerometer with Data Acquisition & Communication System including software and all components & accessories) for Field Stations (Observatories), dam crest / free field and galleries conforming to the requirements specified in Technical specification.The system shall include indoor type Surge Protectors and other accessories etc as per specifications with necessary weather proof enclosures etc for data acquisition and for the protection of all components.
4VSAT system for field stations (Observatories) including; • ODU (Antenna with transceiver). • IDU. • AC adapter. • DC adapter. • Ethernet Cable, Connectors etc. conforming to the requirementsspecified in Technical specification.The system shall include indoor type Surge Protectors and other accessories etc as per specifications.
5Solar Power System for field stations (Observatories) as Primary Power System including Solar panels, Charge controller, battery and all cables, cable connectors, mounting racks, indoor type Surge Protection devices and any other accessories conforming to the requirements specified in Technical specification.
6Secondary Power System for the Broad Band Seismographs at field stations (Observatories) including Battery, Stabilizer, Battery charger, indoor type Surge Protection devices and any other accessories, conforming to the requirements specified in Technical specification.
7Secondary Power System for the Strong motion Accelerographs at field stations (Observatories)including Battery, Stabilizer, Battery charger, indoor type Surge Protection devices and any other accessories, conforming to the requirements specified in Technical specification.
8Secondary Power System for VSAT at field stations (Observatories)including Battery, Stabilizer, Battery charger, indoor type Surge Protection devices and any other accessories conforming to the requirements specified in Technical specification.
9Power system for the Strong Motion Accelerographs at various installation locations in dam crest / free field and galleries by extending cables (from the main KSEBL supply point including providing a common control switch at starting point) using 2.5 mm2, 3 core armoured cable with all accessories and including Battery for back up, Stabilizer & Battery charger (IP 67 rating) with spike protection / DC-DC converters, and any other accessories, conforming to the requirements specified in Technical specification.
10Desktop Computer for Control Room in Dam Safety Organisation building,Pallom for data acquisition and analysis including necessary softwares and all accessories conforming to the requirements specified in technical specification.
11Laptop for the field (Idamalayar,Sholayar and Poringalkuthu field offices) including software and all accessories conforming to the requirements specified in Technical specification.
12For Related Services
13Installation, testing, commissioning of Broad Band Seismograph (Seismometer with Data Acquisition& Communication System with KSEBL’s CRS provided etc.)in field stations (Observatories) conforming to the requirements specified in Technical Specifications, Providing lightning protection for the observatory building with horizontal conductors above the roof with aluminium strips 25 x 3 mm along the outer periphery of the building, down conductors and plate earthing at two locations, Providing indoor type Surge Protection devices (SPD) on Panel Board, All related civil works and Providing necessary training, documentation conforming to the Technical specifications and conditions of contract etc complete as directed by the Engineer in charge.
14Installation, testing, commissioning of Strong Motion Accelerograph (Accelerometer with Data Acquisition & Communication System with KSEBL’s CRS provided etc.) in field stations (Observatories), dam crest / free field and galleries conforming to the requirements specified in Technical Specifications,Providing indoor type Surge Protection devices (SPD) on panel board, All related civil works,Providing necessary training, documentation conforming to the Technical specifications and conditions of contract etc complete as directed by the Engineer in charge
15Installation, testing and commissioning of VSAT systemfor field station (Observatory)conforming to the requirements specified in Technical Specifications, Providing indoor type Surge Protection devices (SPD) on panel board, All related civil works and Providing necessary training, documentation conforming to the Technical specifications and conditions of contract etc complete as directed by the Engineer in charge.
16Installation, testing and commissioning of Solar Power System for field stations (Observatories) as Primary Power System including Solar panels, Charge controller, battery and all cables, cable connectors, mounting racks and any other accessories conforming to the requirements specified in Technical specifications,Providing indoor type Surge Protection devices (SPD) on panel board, All related civil works and Providing necessary training, documentation conforming to the Technical specifications and conditions of contract etc complete as directed by the Engineer in charge.
17Installation, testing and commissioning of Secondary Power System for the Broad Band Seismographs at field stations (Observatories) including Battery, Stabilizer, Battery charger and any other accessories, conforming to the requirements specified in Technical specifications,Providing indoor type Surge Protection devices (SPD) on panel board, All related civil works and Providing necessary training, documentation conforming to the Technical specifications and conditions of contract etc complete as directed by the Engineer in charge.
18Installation, testing and commissioning of Secondary Power System for the Strong motion Accelerographs at field stations (Observatories) including Battery, Stabilizer, Battery charger and any other accessories, conforming to the requirements specified in Technical specifications,Providing indoor type Surge Protection devices (SPD) on panel board, All related civil works and Providing necessary training, documentation conforming to the Technical specifications and conditions of contract etc complete as directed by the Engineer in charge.
19Installation, testing and commissioning of Secondary Power System for VSAT at field stations including Battery, Stabilizer, Battery charger and any other accessories conforming to the requirements specified in Technical specifications,Providing indoor type Surge Protection devices (SPD) on panel board, All related civil works and Providing necessary training, documentation conforming to the Technical specifications and conditions of contract etc complete as directed by the Engineer in charge.
20Installation, testing and commissioning of Power System for the Strong motion Accelerographs at various locations (in dam crest / free field and galleries) including 2.5 mm2, 3 core armoured cable, control switches, Battery, Stabilizer & Battery charger (IP67 rating) with spike protection / DC-DC converters, providing crossings for cables (wherever necessary ) and with all other accessories, all related Civil and Electrical works, Providing necessary training, documentation conforming to the Technical specifications and conditions of contract etc complete as directed by the Engineer in charge.
21Installation, Testing and commissioning of Desktop Computer at Control Room in Dam Safety Organisation building, Pallom with necessary softwares etc complete conforming to the requirements specified in Technical Specifications, and providing necessary training as directed by the Engineer in charge.
22Installation, Testing and commissioning of Laptop with necessary softwares etc complete conforming to the requirements specified in Technical Specifications, and providing necessary training as directed by the Engineer in charge.
23Integrating the data obtained from the newly added seismic equipments with the existing KSEBL network system of seismic equipments and connected CRS at Thiruvananthapuram,making arrangements to obtain all seismic datas received at CRS, Thiruvananthapuram in the desktop computer installed at the Control Room in Dam Safety Organisation building, Pallom via the SEED link or any other alternative methods. The work includes installation of all necessary softwares etc as directed by the Engineer in charge.
24Recurring Expenditure for VSAT (for five years)
25In Route: 36 kbps TDMA in route bandwidth for Total networking including DOT & WPC share for total network.
26Out Route: 16 kbps TDMA satellite bandwidth charges for total network including DOT and WPC revenue share and VSAT network monitoring charges for total network.
27Backhaul connectivity: 24 kbps SCPC Satellite bandwidth link charges for KSEBL including DOT and WPC revenue share and VSAT network monitoring charges for total network.
28CAMC charges of entire system including Seismic equipment, Data Acquisition & Communication System, maintenance of Computers,maintenance related with integration of data with the CRS system at Thiruvananthapuram and obtaining all seismic data from CRS, Thiruvananthapuram in the desktop computer at Control Roomin Dam Safety Organisation building,Pallom, VSAT system (including spare parts, modules, cards, subunits, consumables, IDU, ODU, Modem, Routers, antennas, cables, connectors,SPDs,field visit charges, providing training, repairing charges, transportation, maintenance cost of entire system including that of related civil works) Lightning Protection, Earthing and Surge protection etc. completefor Year I after warranty period.
29CAMC charges of entire system including Seismic equipment, Data Acquisition & Communication System, maintenance of Computers, maintenance related withintegration of data with the CRS system at Thiruvananthapuram and obtaining all seismic data from CRS, Thiruvananthapuram in the desktop computer at Control Roomin Dam Safety Organisation building,Pallom, VSAT system (including spare parts, modules, cards, subunits, consumables, IDU, ODU, Modem, Routers, antennas, cables, connectors, SPDs, field visit charges, providing training, repairing charges, transportation, maintenance cost of entire system including that of related civil works) Lightning Protection, Earthing and Surge protection etc. completefor Year II after warranty period.
30CAMC charges of entire system including Seismic equipment, Data Acquisition & Communication System, maintenance of Computers, maintenance related withintegration of data with the CRS system at Thiruvananthapuram and obtaining all seismic data from CRS, Thiruvananthapuram in the desktop computer at Control Roomin Dam Safety Organisation building,Pallom, VSAT system (including spare parts, modules, cards, subunits, consumables, IDU, ODU, Modem, Routers, antennas, cables, connectors, SPDs, field visit charges, providing training, repairing charges, transportation, maintenance cost of entire system including that of related civil works) Lightning Protection, Earthing and Surge protection etc. completefor Year III after warranty period.