Tender For Providing Electrical Infrastructure Works, Ductabe Ac Units, Surveillance And Access Control System, Automatic Fire Detection Systemfor The Porposed Phase Ix.2 Server Installation At Ii Floor Msc, Te Dtax, Vijayawada. ( Sh: Ei & Fans , vijayawada-Andhra Pradesh

Bharat Sanchar Nigam Limited-BSNL has published Tender For Providing Electrical Infrastructure Works, Ductabe Ac Units, Surveillance And Access Control System, Automatic Fire Detection Systemfor The Porposed Phase Ix.2 Server Installation At Ii Floor Msc, Te Dtax, Vijayawada. ( Sh: Ei & Fans . Submission Date for this Tender is 22-09-2023. Electrification Work Tenders in vijayawada Andhra Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

39654954
Tender For Providing Electrical Infrastructure Works, Ductabe Ac Units, Surveillance And Access Control System, Automatic Fire Detection Systemfor The Porposed Phase Ix.2 Server Installation At Ii Floor Msc, Te Dtax, Vijayawada. ( Sh: Ei & Fans
Open Tender
Indian
Andhra Pradesh
vijayawada
22-09-2023

Tender Details

Providing Electrical Infrastructure Works, Ductabe Ac Units, Surveillance And Access Control System, Automatic Fire Detection Systemfor The Porposed Phase Ix.2 Server Installation At Ii Floor Msc, Te Dtax, Vijayawada. ( Sh: Ei & Fans )

Key Value

Document Fees
INR 590 /-
EMD
INR 8493.0 /-
Tender Value
Refer document

BOQ Items

Name of work:Providing Electrical Infrastructure works, Ductabe AC units,Surveillance and Access Control System, Automatic fire detection systemfor the porposed Phase IX.2 Server Installation @ II floor MSC,TE DTAX,Vijayawada. (SH: EI & Fans)
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
2Group C
3Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
4Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 2 Nos 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
5Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
62 x 1.5 sq. mm
73 x 1.5 sq. mm
84 x 1.5 sq. mm
9Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
1020mm
11Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings).
12Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required.
13Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB"s (but without MCB"s and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
144 way (4 + 12), Double door
15Supplying and fixing following way, single pole and neutral sheet steel MCB DB, 240 V, on surface /recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
162 + 8 way, Double door
17Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
18Triple pole
19Triple pole
20Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2163 A
22Supplying and drawing of 1" PVC flixible pipe for cables etc as reqd
2340 A
24Supplying and fixing Cable End Box (Loose wire box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.
25Supplying and fixing Cable End Box (Loose wire box)(IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and commissioning etc. as required. For 8 way, Double door SPN MCBDB
26Supplying and Laying of one number XLPE insulated and PVC sheathed aluminium conductor armoured power cable of 1.1 kV grade of following size on wall surface as required.
273½ X 50sq. mm
284 X 16sq. mm
29Supplying and Laying of one number XLPE insulated and PVC sheathed aluminium conductor armoured power cable of 1.1 kV grade of following size in the existing masonry open duct as required.
303½ X 50sq. mm
314 X 16sq. mm
32Laying of one number XLPE insulated and PVC sheathed aluminium conductor armoured power cable of 1.1 kV grade of following size on wall surface as required.
333½ X 240sq. mm
34Laying of one number XLPE insulated and PVC sheathed aluminium conductor armoured power cable of 1.1 kV grade of following size in the existing masonry open duct as required.
353½ X 240sq. mm
36Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
373½ X 240sq. mm
383½ X 50sq. mm
394 X 16sq. mm
40Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
41Supplying, Installation, testing and commissioning of the following pre-wiredLED fitting , complete with all accessories etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
42Surface/suspended type 4 Ft LED Integrated batten fitting with fire retardent extruded Plastic / metal frame withpower input of 20 W and withappx 2000 Lumens, 6500K or more. (Philips /Wipro Trim LED Neo LL 20/Bajaj Baton/Cromptionor Similar Superior make)
43SITC of floor/ wall mounting cubicle type LT panel suitable for 415V, 3 phase, 4 wire, 50 Hz AC supply systemfabricated in compartmentalized design from CRCA sheet of 2 mm thick for frame work & load bearing members and 1.6 mm for covers & doors, 2 mm thick for gland plates,powder coated in approved shade having 400 Amps 4 stripsAluminum alloy bus bars of high conductivity with heat shrinkable coloured sleeves,DMC/ SMC bus bar supports, , bottom base channel of MS section not less than 100mm x 50 mm x 5mm thick, entire panel shall have a common copper earth bar of size 25mm x 3 mm at the rear with 2 numbers earth stud, solid connections from main bus bars to switch gears with requiredsize Al. bus bars and control wiring with 1.5sq.mm PVC insulated copper conductor FRLSwires, cable alleys, cable gland plates in two halves, i/c providing following switch gears and providing necessary channel/angle iron supports of suitable size for mounting the panel etc as required as per specificationas required.
44Incoming 315 Amp 4 Pole Switch disconnector fuse unitwith HRC fuses - 2Nos. with mechanical inter locking Mechanism.
45Out going - 250 Amp 3 Pole SDF with HRC fuses- 04 Nos 125 Amp 3 pole SDF with HRC fuses-1 No 63 Amp 3 pole with HRC fuses- 2 Nos
46Metering Panel a. Digital VAF (96X96 mm) - 1 No. b.Suitble rating CTs - 1 Set c. RYB LED Indication Lamp - 1set
47Note: The panel drawing shall be got approved by the Engineer in charge before fabrication.( All Items shall be BSNL approved make)
48Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail