| 1 | Earthwork in excavation of foundation in hard soil including dressing & levelling of bed within initial lead of 50mt. & lift of 1.5mtr etc complete as per the direction of the Engineer-incharge. |
| 2 | Filling in foundation & plinth with sand including watering & ramming etc complete as per the direction of the Engineer-incharge. |
| 3 | Cement concrete (1:4:8) with 4cm size h.g.c.b. metal of approved quality from approved quarry with ramming watering and curring etc. complete including cost, taxes, royalty convence charge of all material to worksite, supply of cement T&P required etc. complete as per the direction of the Engineer-incharge. |
| 4 | Reinforced Cement Concrete (1:2:4) with 12cm size h.g.c.b. Chips of approved quality from approved quarry with ramming watering and curring etc. complete including cost, taxes, royalty convence charge of all material to worksite, supply of cement T&P required etc. co |
| 5 | Rigid smooth centering & shuttering for R.C.C. works including false work & dismateling then after including cost of materials in ground floor complete as directed by the Engineer-incharge. |
| 6 | M.S. reinforcement for R.C.C. work including supplying, cutting, bending, binding & tying the grills & placing in position including cost of binding wire 18 to 20 guage per Qntl. Including cost of HYSD Still Bar (FE 415/ FE 500) |
| 7 | 12mm cement plaster in cement mortar (1:6) finished smooth to brick work after racking out joints including waterring and curring with cost, taxes, royalty and conveyance charges of all material to the worksite and supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge. |
| 8 | Filling the foundation and plinth with excavated material as directed by the Engineer-incharge. |
| 9 | Dismantling of Lime concrete, cement concrete grade M-10 and below including T&P and scaffolding whereever necessary, sorting the dismantled material, disposal of unserviceable materials with all lifts and lead. |
| 10 | C.B. Brick masonry 25cm x 12cm x 8cm size having crushing strength not less than 75kg / cm2 with dimensional tolerrance + 8% in cement mortar (1:6) in foundation & plinth etc. complete as per the Engineer-incharge. |
| 11 | Cost of fitting of AR valve |
| 12 | Foundation Nut bolt. |
| 13 | Cost of laying & fittings of M.S./PVC Tee alongPVC pipeline(fitting of outlets) |
| 14 | Labour charges for letter writting on display board in black colour on yellow back ground painting including cost of material, labour etc. |
| 15 | Monoblock pump set total head of 18 mtrs capable to discharge 1700 LPM with 10 HP/7.50 KW squirrel cage induction motor fitted with bronze impeller TB-2 of IS 318/1981, companion flanges & Class \"F\"insulation suitable for operation 415 volt +6%-15% 3 phase, 50Hz AC poweer supply suction/deliveery= 100mmx100mm with BEE Star rated energy efficiency Pump & as per IS-9079/2002 with overall efficiency 62 to 65% of reputed brand having wide dealership net work for easy availability of spares.The materials of construction as given below (a) Casing: FC 200 as per IS 210/1978 (b) Impeller: Bronze grade LTB-2 of IS 318/1981 |
| 16 | Automatic Star Delta starter sheet steel enclosure suitable for operation of squirrel cage Induction motor upto 15 HP (13-20) with 16. Amp (AC-3) contactor at 415 volt +6%-15%, 3 phase, 50 Hz, AC supply with suitable overload relay & No volt coil with electric pnemutic timer suitable for operation at voltage range of 300-440 volt including cost of transportation to site The starter should provide dependable protection against overload and single phasing & should be of reputed brand having wide dealership network for easy availability of spares. |
| 17 | Cost of 63 Amp. Main Switch Triple pole & natural of voltage range 440 volt of re-wirable fuse and shall confirming to IS-4064(PT-I & II ) with ISI markincluding all taxes etc. |
| 18 | Empty Outdoor Irrigation Pannel Board size (0.45mtx0.25mtx1.20m of 18 SWG Cold Rolled M.S Sheet with 4legs of 300 size with one coat of Red Oxide Primer and two coats of Smoke grey /Navy bluetwo coats of powder coated paint of approved quality on both side (Inside & Outside) suitable to mount 3Phase Starter, Main Switch and Capacitor inside the Panel Board vertically over 18 SWG M.S.Sheet and the danger board fixed on the top of the Panel Door. |
| 19 | Motor hood size (0.45mx0.45mx0.60m) made with 18 SWG (cold rolled M.S.Sheet with one coat of red axide primer and two coats of powder coated paint of approved quality on both side (inside & outside) suitable to cover centrifugal monoblock Pump Set from 10 HP to 15 HP and having provision for attachement with the groves on rear side of the pannel board. |
| 20 | 4KVAR Power ShuntCapacitor with ISI mark of reputed company. |
| 21 | Base frame for panel (size 0.40mx0.20m) made with 3 size M.S. channel having suitable holes for fitting of panel Board, coloured with one coat of red oxide primer and two coats of powder coated paint of approved quality & Base frame for motor (size 0.50mx0.27m) made with 3 size M.S. channel having suitable holes for fittings of different size and make 3 phase centrifugal monoblock pump set from 10 HP. to 15 H.P. coloured with one coat of red oxide primer & two coats of powder coated paint of approved quality. |
| 22 | 3x10 sqmm PVC insulated (HD) tropoder armoured Electric Cable with alluminum conductor for use in 3 phase power system of working voltage upto & including 1100 volts at 50Hz confirming to IS 7098(Pt-II) including cost of transportation to site and laying below 0.9mtr of the ground and filling the excavated materials including watering and rammin including all taxed etc. |
| 23 | Cost of 12mm dia PVC Insulated Steel Wire Rope ISI mark of reputed Company. |
| 24 | Electrical Earthing including all materials as per the direction of the Engineer- incharge |
| 25 | Electrical installation and energisation (including cost of volt meter-5 nos, CT type Amp. Meter-5 nos, selector switch- 5 nos, CT - 2 nos(100:5), indicator - 15 nos,100 Amp Kit kat - 15 nos, cable socket, internal and external wiring at pump chamber etc. |
| 26 | 100mm dia nominal bore G.I.pipe having wall thickness 4.5mm electrical resistance welded of medium class confirming to IS- 1239(part-1/2004) with latest ammendments, screwed at both ends as per IS-554 with socketed at one end and the other end protected with plastic threaded protector including its transportation and unloading at L.I.P. site. The socket confirming to ISI 1239(part II/1992) with latest ammendments in random length of 4 to 7 mtr. Each pipe should bear IS certification and manufacturers name/trade mark. |
| 27 | 100mm dia G.I.Bend( Medium Duty) conforming to IS No-1239 (part II/1992) with ISI mark of reputed company. |
| 28 | 100mm dia G.I.Flange( Medium Duty) conforming to IS No-6392/1971 with ISI mark of reputed company. |
| 29 | 100mm dia C.I. Screw boss Foot Valve of swing type friction less with single disc conforming to IS-4038/1979 of reputed brand with ISI mark of reputed company having wide dealership network. |
| 30 | Thick Rubber Insertion and Nut & Bolt etc. |
| 31 | Supply of 200mm dia unplasticised riged UPVCpipe ivory in colour having specific gravity of 1.40 to1.46 gms/cc of straight length of 6(six) meter for portable water supplies conforming to IS-4985/2000 of BIS-Amendment-2 read with Table-1 of IS-specification bearingISImarks for working pressure CI-I UPVC pipe to withstand pressure of 2.5kgf/sqcm& the specification and manufacture name should be prominently marked on body of each pipe as per the latest Amendment of IS-4985. It includes the cost of sockets in case of plain ended pipe. PDI test are to be condcuted and should be marked on body of each pipe and report is to be obtained from CIPET, Bhubaneswar necessary approval of authority including transporation to work site in complete shape and handed over to Pani Panchayat President or Secretary. |
| 32 | Fitting of un-plasticised 200mm diaPVC Pipe for following inside dia mtr. for all classes of pipe including jointing the pipe with solvent cement by non-head application method including fitting and fixing of required no. of PVC Tee for outlet and PVC Shaddle and PVC Riser nipple for fitting air valve, equal Tee etc. complete including conveyance pipe from village to worksite and testing of pipe line etc. complete as per the direction of the Engineer-incharge. |
| 33 | 100mm dia C.I.Double Flanged Non Return Valve swing type PN-1.0 (IS-5312(Part-I-2004) with bypass arrangement with ISI mark of reputed company. |
| 34 | 50mm dia C.I.Air Release Valve (single action) with saddle and Raiser pipe conforming to IS 14845 (SI) with ISI mark from reputed company. |
| 35 | 200×200×200mm F P.V.C Equal Tee(W.P 4Kg/Cm2) conforming to IS-4995/ 1988 with latest amendment. |
| 36 | 200 mm F P.V.C End Cap (W.P-10 Kg/cm2) conforming to IS-4995/ 1988 with latest amendment. |
| 37 | 200 mm F P.V.C Coupler(W.P 4Kg/Cm2) agricultural PVC fittings conforming to IS-4995/ 1988 with latest amendment. |
| 38 | 100mm x 100mm x 25mm dia G.I. Priming Tee with Plug |
| 39 | Miscellaneous welding charges for \"Z\" joint, \"S\" bend etc. |
| 40 | 200mmx200mmx110mm dia Weldless G.I.Tee(3.6mm thickness) with bend, closing and opening arrangement of reputed company. |
| 41 | Labour charges for Installation of pumpset and delivery fitting including fitting of Priming Tee, Sluice Valve, NR Valve, Air Release Valve, Riser Tee, PVC Tee and lowering of pump and transportation etc complete. & fixing suction and delivery pipe to motor, NR Valve, Foot Valve, Sluice Valve and other fitting materials including cutting, welding etc. complete as per the direction of the Engineer-incharge. |
| 42 | Thick Rubber Insertion |
| 43 | Nuts and Bolts |
| 44 | 200mm diaC.I. Butter Fly Valve BS:5155/15: 13095-CI MOC Lever Operated PN-1.0 with ISI mark of reputed company. |
| 45 | Construction of 3 phase 11 KV HT line as per REC standard confirming to IE Rules 1956 with 300 kg 9 M long PSC Pole with 55 Sqmm Insulated Conductor average span length40mtr with ,11 KV \"V\" Cross arm, with required No.of 11 KV T & C Disc. Polymer Insulators in tension point &11 KV Pin Polymer insulators, Couping & Padding of Poles with all G.I.Channels. Danger Board at each Pole, Anti Climbing Devices, Stay Set at Bending point & double stay at end point with 18 mm G.I.H.T.Stay, concreting of Stay with Anchor plate, guarding at Road crossings etc if required including cost of all materials, labour transportation,inspection & commissioning etc. complete. |
| 46 | Construction anderection of 11 /0.4 KV ,25 KVA Double Pole mounted Substation with5mtrx3mtrx1.5mtr height mesonary toe wall /G.I. Flat fencing boundary wall withFlat with Polymer insulator ,L.T DistBox with MCCB , Aluminim bus bar of single bay with kitkat fuse , sand filling and metal spearding with M.S.Grill gate ,all Channel matrials should be G.I , 7 Nos earthing with chamber with 3mtr G.I pipe of40mm dia with connecting of 25mmx 5mm G.I flat to all earthing including 25KVA BIS Leble-II Star rated Transformer confirming to RE Rules 1956, mounted on 2.44 Mtr. Long structure, supported in 300 kg 9 mtr long PSC pole,transformer hard channel & top channel made of 2.8 M long 100 X 50 X 6 mm G.I.Channel, Transformer belting on 2.80 M long 50mm X 50mm X 5 mm G.I.Angle, (all REC SPN Std.F-3) with all accessories like 3 pole 11 KV HG Fuse(F-5)& A.B.Switches(F-9) both mounted on 2.8 M long 75mm X 40mm X 6 mm G.I.Channel and supported by 1.0 M long 50 X 50 X 5 mm G.I.Angle, with 3 No. 11 KV Lightening Arrestors and Danger board at each Pole, Anti climbing Devices & all other necessary fittings i.e required size Nuts & Bolts, Brackets, Cable, Cable Sockets as per TPCOCL specification etc. including cost of all materials, labour , transportation complete with liasioning for testing inspection & commissioning as per specification of TPCODL etc complete. |
| 47 | Construction of 3 Phase L.T.line as per REC standard confirming to RE rule 1956 with 300Kg 9 Mtr long PSC pole support in 0.33M span length with 3x35mm² +1x25 mm ² LT, XLPE AB cable with coil earthing device, LT dead end clam, Suspension clamp with G I hook , stay accessories such as wire insulator , clamp etc. nut bolts, alongwith concreting copping & padding of polesand stayset as per direction of Engineer in Charge. |