Supply, Soil Investigation, Design, Supply Of All Materials, Labour, T&P Etc. Required For Construction,Erection, Completion, Testing And Commissioning Of Water Supply Works Such As Rcc Oht, Rising Main, Distribution System, Tube Wells, Pump House, Staff , meerut-Uttar Pradesh

Uttar Pradesh Jal Nigam-UPJN has published Supply, Soil Investigation, Design, Supply Of All Materials, Labour, T&P Etc. Required For Construction,Erection, Completion, Testing And Commissioning Of Water Supply Works Such As Rcc Oht, Rising Main, Distribution System, Tube Wells, Pump House, Staff . Submission Date for this Tender is 10-10-2023. Pump Supply Tenders in meerut Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

39640143
Supply, Soil Investigation, Design, Supply Of All Materials, Labour, T&P Etc. Required For Construction,Erection, Completion, Testing And Commissioning Of Water Supply Works Such As Rcc Oht, Rising Main, Distribution System, Tube Wells, Pump House, Staff
Open Tender
Indian
Uttar Pradesh
meerut
10-10-2023

Tender Details

Supply, Soil Investigation, Design, Supply Of All Materials, Labour, T&P Etc. Required For Construction, Erection, Completion, Testing And Commissioning Of Water Supply Works Such As Rcc Oht, Rising Main, Distribution System, Tube Wells, Pump House, Staff Quarter, Boundry Wall And Site Development Works Etc. And Other Appurtenant Works Including Scada And Automation As Per Specifications In Tender Document For Kithaur Water Supply Re-Organization Scheme. The Scope Of Work Also Includes Trial Run Of 03 Months And Defect Liability Period Of 12 Months For Civil Works And 24 Months For E / M Works After Completion Of Successful Trial Run. All Completed And Commissioned Work Under Kithaur Water Supply Re-Organization Scheme Shall Be Handed Over To Kithaur Nagar Panchayat After 03 Months Successful Trial Run Period.

Key Value

Document Fees
INR 23600 /-
EMD
INR 1795000.0 /-
Tender Value
INR 17.94 Crore /-

BOQ Items

Name of Work: Supply, Soil investigation, Design, Supply of all materials, Labour, T&P etc. required for construction,erection, completion, testing and commissioning of water supply works such as RCC OHT, Rising main, Distribution system, Tube wells, Pump house, staff quarter, Boundry wall and site development works etc. and other appurtenant works including SCADA and Automation as per specifications in tender document for Kithaur Water Supply Re-organization Scheme. The scope of work also includes trial run of 03 months and defect liability period of 12 months for civil works and 24 months for E/M works after completion of successful trial run. All completed and commissioned work under Kithaur Water Supply Re-Organization Scheme shall be handed over to Kithaur Nagar Panchayat after 03 months successful trial run period.
Sl. No. Item Description
1OHT
2Submission of design, drawing, testing of bearing capacity of soil and supply of all material, labour T&P etc. and construct as per tenderer"s own seismic proof design and drawings (approved by the department) complete intze Type on raft or pile cum raft foundation with columns and braces R.C.C. Over Head Tank of following capacity and staging from made up ground level at site to the top of bottom ring beam of tank, with a minimum free board of 15cm. The design of the tank shall base on safe bearing capacity of soil at site as 8 T/m2 and depth of foundation as 2.50m from existing ground level on pile/raft foundation. made up level of OHT will be taken as 0.70 m above existing gound level. Extra earth required for made up level will be arranged by the contractor at his own cost.If the bearing capacity of soil less than 8 T/m2than the contractor will submit the design on the same B.C.No extra payment will be paid for this. All other details of tank not covered here shall also be as per specifications enclosed.
31650 Kl/ 20 m staging (zone-3)
4Submission of detailed design and drawing from any recognized University such as I.I.T. etc. or as per direction of Engineer in-charge.
5R.C.C. as per approved design including fixing variours pipes and ventilator at top and fixing of M.S. sheet of 10 mm gauge manhole cover of 60cm x 60cm size with frame and locking arrangement and railing including supply of all material.
6Two coloumn R.C.C. stair case with 1.0 m minimum clear width attached with tank body as an access to Balcony and Top Dome of tank from ground level as per design & drawing with 1.25 m high railling andss gate with cabin as per specification including supply of all materials.
7Supply and fixing of S.S.. ladder from inside the tank body from roof to the bottom dome of the tank in a slope of 3 : 1 (3 vertical : 1 horizontal) with raling as specified.
8Railing on staircase & its landings, all around balcony & top dome for access up to ventilator as specifications including supply of all material. Railing shall be provided in three rows of G.I. pipe.icluding ss casing aproved by E/C
9Supply and fixing of digitalwater level indicator as per specifications and fixing of lightening conductor and earth plate etc. as per specifications.
10Testing of tank for water tightness as per specifications enclosed including supply of water.
11Supply of all materials and construction of 25mm thick P.C.C. floor over 80 mm PCC 1:4:8 in apron and 15 cm dia semi circular drain around apron in a slope towards wash out chamber.
12Three coats of approved quality and shade ofApex Painting of as per direction of Engineer incharge over concrete work including supply of all materials etc.
13Supplying, carting and fixing of following sizes C.I. D/F pipes with required specials such as reducers, duck foot bend, bell mouth etc. in inlet the tank including supply of M.S. clamps, rubberinsertion sheet, nut bolts, washer etc. complete as per specifications :a. 200 mm (z-3)dia in inlet-3 Nos b. 350 mm (z-3)dia in outlet-1No. c. 300mm(z-3)dia in over flow-1No d. 150 mm dia (z-3)in wash out-1No.
14Supplying and fixing of following sizes C.I. D/F sluice valves as per relevent latest I.S. specifications including supply of all jointing and other materials such as rubber insertion sheet, nut bolts, washer etc. complete as per specifications.a. 200 mm (z-3)dia in inlet-3 Nos b. 350 mm (z-3)dia in outlet-1No. c. 300mm(z-3)dia in over flow-1No d. 150 mm dia (z-3)in wash out-1No.
15Suplly all materials labour T&P and construct brick masonry sluice valve chambers including R.C.C. cover as per deptt. Type design at inlet, outlet and washout pipes. The R.C.C. cover shall be casted inS.S. Channel section with handles on both sides. (Sluice valve chamber for over flow & wash out may be combined)
16The words U.P. Jal Nigam (urban), stating year of construction, capacity of O.H.T. and slogan approved by Engineer in charge shall be painted prominently in letter not less than 30 cm. in height.
17Maintenance for 12 months inclucding supply of all materials etc. complete.
18RISING MAIN
19Dismantling of following type of road surface for laying of pipe line including sorting out of serviceable and unserviceable materials proper stacking of serviceable materials at suitable place and disposal of unserviceable materials at suitable place.
20Bituminous Road
21Concrete Tile Road
22Cement ConcreteRoad
23Excavation of earth in ordinary soil (loam, clay or sand) to give upto 1 mt. Cover from top of the pipe including lift upto 1.5mt. and leadfrom centre of trenches and refilling of earth in 20 cm. layers with watering and ramming etc. complete in all respect.
24Supply of following pipesincluding cost ofpipes, FOR destination, all taxes duties and insurance charges,cost ofjointing materials, loadingunloading, third party inspection charges, packing and forwarding charges, road transportation charges etc complete.
25200 mm diaD.I. K-9 Pipe (conforming to IS : 8329)or latest amenment
26150 mm diaD.I. K-9 Pipe (conforming to IS : 8329)or latest amenment
27Carting, laying & jointing following type ofpipes and lowering the same into already prepared trenches and laying true to alignment and gradient, includingall labour, T&P, supply & fixing of allD.I./ CI specials conforming to latest / relevant IS specification as per requirement of site, loading and unloading, shifting of public utilities if any, alsoincludes sectional pressuretesting of pipe line etc. all complete as per direction of Engineer in charge.
28200mm diaD.I. K-9 Pipe
29150mm diaD.I. K-9 Pipe
30Supply, Carting to site of work, lowering, fixing and jointing of following sizes of fittings in trenches including FOR destinstion,all taxes and insurance, cost of fittings, all jointing materials, such as rubber packing, nut bolts any type of D.I.specials etc. complete work as per direction of Engineer in charge.
31200 mm C.I. D/F Sluice Valve IS 780-1969
32150mm C.I. D/F Sluice Valve IS 780-1969
33CI double orifice type Air valve 20 mm dia
34RCC thrust block in RCC 3:1.5:1 (3 parts stone grit 10 to 20 mm, 1.5 parts coarse sand and 1 part of cement) including cost of material, all labour T&P etc. complete work.
35MS steel of iron work in plain work such as R.C.C.work (when not included in overall rates) brought to required shape as necessary including bending for proper completion of the work including supply of steel and wastage.
36Supply of all materials and construction of following chambers as per type design of U.P. Jal Nigam including supply of labour, materials, T&P etc. complete.
37Sluice Valve Chambers (Masonry Type)
38Air Valve Chambers
39Reinstatement of following type of roads including supply of materials, labour T&P etc. as per specifications
40Bituminous Road which includes Laying of Bituminous road providing grannular sub base, WBM, Dense bituminous macadam and bituminous concrete course in desired thickness along with primer, tack coat and seal coat (Thick ness may be taken according to PWD specification of the respective roads) and proper compaction including all material, labour, T&P etc. complete.
41C.C.Tiles Road which includes Laying of 80mm thick C.C soling including dressing surface and including supply of tile, filling of jointing with local sand spreading and blinding coat of 10 mm to 25 mm deep of local sand over the entire surface and including all labour T&P etc. required for proper completion of work with P.C.C. 1:6:12 in cement course sand and 40 mm th. Stone ballast.
42Cement ConcreteRoad which includes Laying C C road slab 100mm thick in 1:2:4 cement, coarse sand and 20 mm stone ballast including supply of all labour, material, T&P etc. complete as per direction of engineer in charge.
43P.C.C. (1:4:8)in base concrete 75 mm thick in cement, course sand and 40 mm th. Stone ballast including supply of all labour, material, T&P etc. completeas per direction of engineer in charge.
44DISTRIBUTION SYSTEM
45Dismantling of following type of road surface for laying of pipe line including sorting out of serviceable and unserviceable materials proper stacking of serviceable materials at suitable place and disposal of unserviceable materials at suitable place.
46Bituminous Road
47Cement Concrete Road
48Interlocking C.C. TileRoad
49Excavation of earth in ordinary soil (loam, clay or sand) to give 1 mt. Cover from top of the pipe including lift upto 1.5 mt. and leadfrom centre of trenches and refilling of earth in 20 cm. layers with watering and raimming etc. complete in all respect.
50Supply of following pipesincluding cost ofpipes, FOR destination, all taxes duties and insurance charges,cost ofjointing materials, loadingunloading, third party inspection charges, packing and forwarding charges, road transportation charges etc complete.
51D.I. Pipe K-7 conforming to IS 8329 / 2000or its latest amendment
52200 mm dia
53250 mm dia
54300 mm dia
55350 mm dia
56400 mm dia
57HDPE PipePN 6 : class PE 100 as per B.I.S. code no. 4985 / 2000 or its latest amendment
58110 mm dia
59140 mm dia
60160 mm dia
61180 mm dia
62Carting, laying & jointing following type ofpipes and lowering the same into already prepared trenches and laying true to alignment and gradient, includingall labour, T&P, supply & fixing of all HDPE / D.I./ CI specials conforming to latest / relevant IS specification as per requirement of site, loading and unloading, shifting of public utilities if any, alsoincludes sectional pressuretesting of pipe line etc. all complete as per direction of Engineer in charge.
63D.I. Pipe K-7 conforming to IS 8329 / 2000or its latest amendment
64200 mm dia
65250 mm dia
66300 mm dia
67350 mm dia
68400 mm dia
69HDPE PipePN 6 : class PE 100 as per B.I.S. code no. 4985 / 2000 or its latest amendment
70110 mm dia
71140 mm dia
72160 mm dia
73180 mm dia
74Supply, Carting to site of work, lowering, fixing and jointing of following sizes of fittings in trenches including FOR destinstion,all taxes and insurance, cost of fittings, all jointing materials, such as rubber packing, nut bolts any type of HDPE/D.I.specials etc. complete work as per direction of Engineer in charge.
75C.I. D/F Sluice Valve (PN 1.0/ IS 14846)
76400mm dia
77300mm dia
78250mm Dia
79200mm Dia
80150mm Dia
81Scour Valve(PN 1.0/ IS 14846)
82100mm Dia
83150mm Dia
84Fire Hydrant ( as per latest IS specifications)
8580 mm dia (Sluice Valve Type)
86Air Valve Single Orifice( as per latest IS specifications)
8720 mm dia
88Supply of all materials and construction of following chambers as per type design of U.P. Jal Nigam including supply of all labour, material, T&P etc. complete.
89Sluice Valve Chambers (Surface Box Type)
90Fire Hydrant Chambers
91Air Valve Chambers
92Crossing of Nala (big) above 1.0mwide and culvert by making hole below its bed without obstructing the flow of water and also including the repair of any damages done during this work including suppyling and laying of C.I. Pipe etc. complete as per direction of engineer in charge.
93Crossing of Nalasmall (up to 1.0 m wide) and culvert by making hole below its bed without obstructing the flow of water and also including the repair of any damages done during this work including suppyling and laying of C.I. Pipe etc. complete as per direction of engineer in charge.
94Reinstatement of following type of roads including supply of all materials, labour,T&P etc.required for proper compiition of workas per specifications
95Bituminous Road which includes Laying of Bituminous road providing grannular sub base, WBM, Dense bituminous macadam and bituminous concrete course in desired thickness along with primer, tack coat and seal coat (Thick ness may be taken according to PWD specification of the respective roads) and proper compaction including all material, labour, T&P etc. complete.
96Cement ConcreteRoad which includes Laying C C road slab 100mm thick in 1:2:4 cement, coarse sand and 20 mm stone ballast including supply of all labour, material, T&P etc. complete as per direction of engineer in charge.
97P.C.C. (1:4:8)in base concrete 75 mm thick in cement, course sand and 40 mm th. Stone ballast including supply of all labour, material, T&P etc. completeas per direction of engineer in charge.
98C.C.Tiles Road which includes Laying of 80mm thick C.C soling including dressing surface and including supply of tile, filling of jointing with local sand spreading and blinding coat of 10 mm to 25 mm deep of local sand over the entire surface and including all labour T&P etc. required for proper completion of work with P.C.C. 1:6:12 in cement course sand and 40 mm th. Stone ballast.
99Supply of all labour, materials, T&P etc. all complete and inter - connecting existing system with the proposed distribution network at various points. Diameter from 100 mm to 500mm pipeincluding all labour T&P etc. required for proper completion of work
100Supply of all labour, materials, T&P etc. all complete and disconnecting existing system to segregate zonal distribution network at various points. including all labour T&P etc. required for proper completion of workDiameter from 100 mm to 500mm pipe
101Supply of all material like HDPE pipe 20mm (OD), GI pipe 15 mm dia, clamp with saddle, all specials, brass ferrule, bibcock as per relevent IS specification for making house connection with distribution main including dismantling of road, supply, carting of specials, lowering them into trenches, fixing them in proper alignment and jointing including bailing out of water, necessary excavation for connection including all labour, T&P etc. required for proper completion of the work.
102110 mm to125mmdia HDPE Pipe
103140 mm to 180 mm dia HDPE Pipe
104200 mmto 250 mm dia DI K-7 Pipes
105300 mm to 350 mm DI K-7 Pipes
106400 mm to 500 mm DI K-7 Pipes
107Supply of all material like HDPE pipe 20mm (OD), GI pipe 15 mm dia, clamp with saddle, all specials, brass ferrule, bibcock as per relevent IS specification for Shifting of water house hold connectionsincluding dismantling of road, supply, carting of specials, lowering them into trenches, fixing them in proper alignment and jointing including bailing out of water, necessary excavation for connection including all labour, T&P etc. required for proper completion of the work.
108110 mm to125mmdia HDPE Pipe
109140 mm to 180 mm dia HDPE Pipe
110Surveysite Investigation Planning, design Drawings (crossing length 15m to 20m ), Road for of required dia Rising main and distribution pipe with casing pipe as required for proper completion of work required size of MS casing pipe as per drawing and as per (IS:3589 & made from confining to IS:2062) with 750 Micron PU coating internally and 250 micron anti corrosive bituminous paint externally by trenchless technology method at an average depth 2.0 mtr from normal ground level up to top of casing pipe including excavation & filling of Pit, Dewatering arrangement, Supporting system for soil,all complete work including supply & fixing specials in carrier pipe over main pipe, including supply of all materials, labour T&P etc. for proper completion of work as per instruction of Engineer in charge
111Road crossing for 250 mm dia pipe
112BUILDING WORK
113Excavation in foundation in ordinary soil (loam,clay or sand) including lift up to 1.50 m & lead up to 50 m,refilling,watering and ramming of evcavated earth into the trenches or space betwwen the building and sides of foundation trenches or into the plinth and disposal of surplus earth anydistance inside gram panchayat boundary as per site engineer instructions.
114Concrete with 40 mm gauge brick ballast,local sand and cement in proportion in 12:6:1 in foundation including supply of all material,labour T & P etc. required for proper completion of work.
115Concrete with 40 mm gauge brick ballast,local sand and cement in proportion in 8:4:1 in foundation including supply of all material,labour T & P etc. required for proper completion of work.
116Ist. Class brick work in 1:6 cement and local sand mortar in foundation and plinth including supply of all material,labour T & P etc. required for proper completion of work.
117Ist. Class brick work in 1:4 cement and coarse sand mortar in foundation and plinth including supply of all material,labour T & P etc. required for proper completion of work.
11820 mm thick D.P.C.with cement and approved coarse sand 1:2 including 5% water proofing material or in proportion as specied by the manufactures including supply of all material,labour T & P etc. required for proper completion of work.
119Ist. Class brick work in 1:6 cement and coarse sand mortar in super structure including supply of all material,labour T & P etc. required for proper completion of work.
120Ist. Class brick work in 1:4 cement and coarse sand mortar in super structure in half brick thick wall including supply of all material,labour T & P etc. required for proper completion of work.Ist.
121Supply and fixing of M.S. angle iron chaukhats of 40 mm x 40 mm x 5 mm with 20 gauge M.S. sheet door shutter including simple moulding straightg work as in chaukhats and also supply of all material,labour T & P etc. required for proper completion of work.
122Supply and fixing of M.S. angle ironof 50 mm x 50 mm x 6 mm post as per drawing including two coat of painting(4.15m length @4.5kg/m)T & P etc. required for proper
123Fixing of hold fast of door and windows choukhats already moulded on choukhats in PCC 1:2:4 etc. required in all respect to complete of work.
124R.C.C. work with cement,coarse sand and 20 mm gauge approved stone ballast in proportion of 1:1.5:3 in sun shed and lintel on doors and windows excluding supply of reinforcement and its bending but including its fixing and binding the same with 0.50 mm thick binding wire and the cost of binding wire and including necessary centering and shuttering supply of all material,labour T & P etc. required for proper completion of work.
125R.C.C. work with cement,coarse sand and 20 mm gauge approved stone ballast in proportion of 1:1.50:3 in slabs excluding supply of reinforcement and its bending but including its fixing and binding the same with 0.50 mm thick binding wire and the cost of binding wire and including necessary centering and shuttering supply of all material,labour T & P etc. required for proper completion of work.
126M. S. or Iron work in plain work such as R.C.C.or R.B. work (when not included in over all rates) brought to required shape as necessary including bending for proper completion of the work including supply of steel and its wastage.
127Supply and fixing of Z- Section section window frames fitted with M.S. bar grill and Shutters openable outside as per drawing and design approved by E/I, hinges of approved quality,M.S. or C.I. handles,hold fast 4 nos of M.S. flat 25x5 mm and 150 mm long, pegs of M.S. 30 cm long having 4 holes with pagester and brackets welded or riveted to frame complete including the cost of Glass Panes & including supply of all material,labour T & P etc. required for proper completion of work.
12812 mm thick plaster with cement and coarse sand mortar I:6 over brick work minimum thickness not to be less than 10 mm including supply of all material,labour T & P etc. required for proper completion of work.
12912 mm thick plaster with cement and coarse sand mortar 1:4 over ceiling including supply of all material,labour T & P etc. required for proper completion of work.
130Supply and fixing of 5 mm thick and20 mm wide glass strips in panels including supply of all material,labour T & P etc. required for proper completion of work.
13125 mm thick 1:2:4cement concrete floor with cement coarse sand and 20 mm gauge stone ballast laid in pannels finished with 3 mm floating coat of neat cement or cement and marble dust in ratio 1:5as specified and removing any overlaping or mortar at the joints of panels if any and giving them uniform finish over 80 mm thick PCC 1:4:8 base concrete including supply of all material,labour T & P etc. required for proper completion of work.
132Painting or varnishing new work or new wood work in small areas with one priming coat and two coat of approved quality paint or varnish including supply of all material,labour T & P etc. required for proper completion of work.
133White washing three coat including supply of all material,labour T & P etc. required for proper completion of work.
134Finishing walls with water proof cement paint of approved make (Apex painting) and quality on new work with two coats to give an even shade including supply of all material,labour T & P etc. required for proper completion of work.
135Supply and fixing of Girder (ISMB) of 225 mmx110 mm size over the pump house including its painting with approved quality paint and also one priming coat.
136Sand filling in plinth staff quarter pump house and chloronating room including supply of all material,labour T & P etc. required for proper completion of work.
137Supply and lay 4 cm thick insulation layer of sand and clay over R.C.C. roof including supply of all material,labour T & P etc. required for proper completion of work.
138Supply cutting and dressing with size and fixing V-Notch of size 90 x90 cm in the by pass chamber as per direction of E/I including supply of all material,labour T & P etc. required for proper completion of work.
139Mud Faska on R. B. or R.C.C. Roof with 100 mm thick clay layer on roof and laying of tiles and jointing them with cement and sand mortar including supply of all material,labour T&P etc. complete.
140Supply & Fix 110 mm dia P.V.C. down pipes complete with rose & bend and gratingswith M.S. clamps 25 X 3 mmfixed on walls & supply of 150 mm long, 6 mmdia nails complete.
141Construction of R.C.C. manhole cover 70x70x10 cm for opening in roof slab and fixing it at openingincluding supply of all material,labour T&P etc. complete.
142Provide and fix R.C.C jalies of size 30x30cm and fixing of R.C.C. jalies and plastering the same including supply of all material,labour T&P etc. complete.
143Earth filling in campusincluding its cost and cartage up to site of work complete including supply of all material, labour T&P etc. complete
144Provision of Internal electrification (conceiled fitting) in PUMP HOUSE suitable 5 Amp lightpoints in each room/verandah/nd 15 Amp Power points with latest ISI fittings & fixtures like LED lights, PVCinsulated 2.50 mm copperwires for L/F points & 4.00 mm for power points and also supply & fixing of main switch boards( MCB Box) of approved quality in each pumphouse as per direction of engineer-in-charge including supply of all material,labour,T&P etc. complete.(other specifications and details can be get from engineer-in-charge.)
145Fixing of 3.6 m wide M.S gate with 1.0 m wide wicket gate as per departmental type design and drawing including fabrication, supply and construction of boundary pillars etc all complete.including supply of all material,labour T&P etc. complete as per direction of engineer in charge.
146M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.
147(1046)115mmstringordripcoarseofIst.Class brick in 1:6 cement and local sand mortar including plastering, cutting drip notch as required and includingsupplyof allmaterial,labourT&Petc. required for proper completion of work.
148(1201) 20 mm thick plaster in dado or skirting in 1:2 cementandsandmortarincludingsupplyofall material,labourT&Petc.requiredforproper completion of work.
149(1206) Sameasitemno1202butwithout base concrete.pcc flooring
150(1161&1162) Same as item no 1161 but pcc in Apron.
151provision for water supply and sanitary works including supply of all ISI marked fittings such asautomatic WC, wash basin, sink , faucet or mixter tap for hot and cold water material, labour,T&Petc. complete as per aproved by E/C in staff quarter and Office cum lab.
152provision for internal electrification including supply ofallISI markedmaterial such copper wire ,modern board, switch ,up to maximum 10nos electric points,ceillingfen and exhaust fen with, ceilling round or sqare led lights ,under ground conduit wiring , including all labour,T&Petc. complete in all respect.in each rooms of staff quarter and lab etc as per direction of engineer-in-charge including in staff quater room and lab .5 Amp lightpoints in each room/verandah/nd 15 Amp Power points with latest ISI fittings & fixtures like LED lights, PVCinsulated 2.50 mm copperwires for L/F points & 4.00 mm for power points and also supply & fixing of main switch boards( MCB Box) of approved quality in staff quarter and Office cum lab.
153Supply of barbed wire
154(1159)Fixingofbarbedwirefencing posttopostin4rowswithtwocross rows12x12gaugeafterstretchingit includinglabour,T&Petc.requiredfor proper completion of the work.
155(1015)Cementconcretewith20 mmgaugestoneballast,coarsesand and cement in proportion of 4:2:1 including supplyofallmaterial,labour T&Petc. required for proper completion of work. In column of baundry wall.
156Construction of 80 mm thick CC Tile approach road over 1:6:12 base concrete including preparation of subgrade etc. completeand spreading 40mm thick local sand including supply of all material,labour T & P etc. required for proper completion of work.
157Recharge of ground water by roof top rain water of pump house and staff quarter, water available from bye pass of tube well and over flow of over head tank as per drawing including supply of all materials,labour, T&P etccomplete (withwater taping arrangement from roof)
158Provision of solar street light withm. s pole 200 W led , automaticaly turn on off etc as per direction of engineer-in-charge including supply of all material,labour,T&P etc. complete.grouting in pcc 1:1:2 (other specifications and details can be get from engineer-in-charge.)
159E&M Works
160Zone-1 T.W.-2,Zone-2 T.W.-1 & 2
161Drilling of borehole for Tubewell contruction by RC Rig Machine including transportation, erection, dismantling of Rig and assoiated T & P complete in all respect including required all material, labour etc.
162Transportation, Erection and Dismantling of Rig Machine
163Drilling by RC Rig Machine 600 mm dia
1640 to 65 mtr. deep
16565 to 100 mtr. deep 500 mm dia
166100 to 145mtr. 500 mm dia
167Tubewell Assembly
168M.S. tubewell assembly with all required parts like plain pipe, slotted pipe (as required upto 50% of plain pipes) rings, well cap, bail plug, clamp, reducer, central guide, support structer etc. As required & as per typed design complete in all respect.
169300 mm. Dia MS ERW Housing/ casing pipe having wall thickness of 7.1mm.
170200 mm. Dia MS ERW Housing/ casing pipe having wall thickness of 7.1mm.
171Supply of pea gravel
172Logging of bore hole by departmental / approved electric logger.
173Lowering of Tube well assembly duly welded including welding electrode and shurounding of pea gravel complete in all respect.
174Lowering of 300mm dia pipe from GL to 60m deep BGL.
175Lowering of 200mm dia pipe from 60 to 100m deep BGL.
176Lowering of 200mm dia pipe from 100 to 130m deep BGL.
177Development of Tubewell by compressor
178Transportation, Installation and Dismantling of 350 PSI Compressor
179Development of Tubewell by Adequate Capacity Air compressor
180Development of Tubewell by O.P. Unit
181Transportation, Installation and Dismantling of3 Cusec O.P. Unit & Yield Test.
182Development of Tubewell by Adequate Capacity by O.P. Unit
183Chemical and Bacterological test of water sample from depaprtmental/ approved lab.
184Baricading/ fencing of the site during the construction of T.W. to ensure that site is not exposed to risk of accident.
185Zone-3 T.W.-1, 2 & 3
186Drilling of borehole for Tubewell contruction by RC Rig Machine including transportation, erection, dismantling of Rig and assoiated T & P complete in all respect including required all material, labour etc.
187Transportation, Erection and Dismantling of Rig Machine
188Drilling by RC Rig Machine 600 mm dia
1890 to 65 mtr. deep
19065 to 100 mtr. deep 500 mm dia
191100 to 165mtr. 500 mm dia
192Tubewell Assembly
193M.S. tubewell assembly with all required parts like plain pipe, slotted pipe (as required upto 50% of plain pipes) rings, well cap, bail plug, clamp, reducer, central guide, support structer etc. As required & as per typed design complete in all respect.
194300 mm. Dia MS ERW Housing/ casing pipe having wall thickness of 7.1mm.
195200 mm. Dia MS ERW Housing/ casing pipe having wall thickness of 7.1mm.
196Supply of pea gravel
197Logging of bore hole by departmental / approved electric logger.
198Lowering of Tube well assembly duly welded including welding electrode and shurounding of pea gravel complete in all respect.
199Lowering of 300mm dia pipe from GL to 60m deep BGL.
200Lowering of 200mm dia pipe from 60 to 100m deep BGL.
201Lowering of 200mm dia pipe from 100 to 150m deep BGL.
202Development of Tubewell by compressor
203Transportation, Installation and Dismantling of 350 PSI Compressor
204Development of Tubewell by Adequate Capacity Air compressor
205Development of Tubewell by O.P. Unit
206Transportation, Installation and Dismantling of3 Cusec O.P. Unit & Yield Test.
207Development of Tubewell by Adequate Capacity by O.P. Unit
208Chemical and Bacterological test of water sample from depaprtmental/ approved lab.
209Baricading/ fencing of the site during the construction of T.W. to ensure that site is not exposed to risk of accident.
210EXISTING PUMPING PLANTfor Zone-01, TW-1
211SITC of Submersible pump set 600 LPM, 56m head(Tentative) with 24m column pipe, NRV,CI D/F Bend 90 ,CI A/F Tee, D/F pipe (1.5 m long 2 nos and 1.0 m long 1 no) Earthing ,Painting ,Toolset, Stablizer,wiring of pump house internal and external, Chain pulley block,and all Pumping plant accessories with nut bolts and rubber packing etc.(All other items for pumping plant item not included in SCADA Automation pumping plant items).
212Copper cable size 2x3cx4 sq mm. Flat
2133mtr heavy duty column pipe 80 mm dia (1 Set consist of 02 column pipe of 3mtr length each)
214Dismentling of old Pumping plant from site and carting upto Nagar Palika Store.
215Automatic chlorination system
216Soft starter with RS-485 port-400V Class 15 Kw rating or more suitable for pump set.
217Auto Phase reversal unit with inbuilt time delay and enclosure (100 Amp.)
218Motor operated actuator with sluice valve 80mm Sluice Valve
219CE & UL certified Inteligent Smart Energy Meter
220CE & UL certified Electro magnatice flow Meter 80mm size
221CE & UL certified hydro static type sub soil water level transmitter for tubewell.
222CE & UL certified pressure transmitter
223CE & UL certified Surge protector for control panel
224Complete cabling of tubewell including all power and control cables of all equipment at pump house and OHT
225Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments)
226REBORE PUMPING PLANTfor Zone-02,Tw-1&2
227SITC of Submersible pump set 1000 LPM, 56m head (Tentative) with 24m column pipe,NRV,CI D/F Bend 90 ,CI A/F Tee, D/F pipe (1.5 m long 2 nos and 1.0 m long 1 no) Earthing ,Painting ,Toolset, Stablizer,wiring of pump house internal and external, Chain pulley block,and all Pumping plant accessories with nut bolts and rubber packing etc.(All other items for pumping plant item not included in SCADA Automation pumping plant items).
228Copper cable size 2x3cx4 sq mm. flat
2293mtr heavy duty column pipe 100 mm dia (1 Set consist of 02 column pipe of 3mtr length each)
2304 x 25 sq. mm Al. cable for power connection
231Dismentling of old Pumping plant from site and carting upto Nagar Palika Store.
232Automatic chlorination system
233Soft starter with RS-485 port-400V Class 15 Kw rating or more suitable for pump set.
234Auto Phase reversal unit with inbuilt time delay and enclosure (100 Amp.)
235Motor operated actuator with sluice valve 100mm Sluice Valve
236CE & UL certified Inteligent Smart Energy Meter
237CE & UL certified Electro magnatice flow Meter 100mm size
238CE & UL certified hydro static type sub soil water level transmitter for tubewell.
239CE & UL certified pressure transmitter
240CE & UL certified Surge protector for control panel
241Complete cabling of tubewell including all power and control cables of all equipment at pump house and OHT
242Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments)
243NEW PUMPING PLANTfor Zone-01, Tw-2
244SITC of Submersible pump set1000 LPM, 60m head (Tentative) with 24m column pipe,NRV,CI D/F Bend 90 ,CI A/F Tee, D/F pipe (1.5 m long 2 nos and 1.0 m long 1 no) Earthing ,Painting ,Toolset, Stablizer,wiring of pump house internal and external, Chain pulley block,and all Pumping plant accessories with nut bolts and rubber packing etc.(All other items for pumping plant item not included in SCADA Automation pumping plant items)
2453mtr heavy duty column pipe 100 mm dia (1 Set consist of 02 column pipe of 3mtr length each)
246Copper cable size 2x3cx4 sq mm.
2474 x 25 sq. mm Al. cable for power connection
248Automatic chlorination system
249Soft starter with RS-485 port-400V Class 22 Kw rating or more suitable for pump set.
250Auto Phase reversal unit with inbuilt time delay and enclosure (100 Amp.)
251Motor operated actuator with sluice valve 100mm Sluice Valve
252CE & UL certified Inteligent Smart Energy Meter
253CE & UL certified Electro magnatice flow Meter 100mm size
254CE & UL certified hydro static type sub soil water level transmitter for tubewell.
255CE & UL certified pressure transmitter
256CE & UL certified Surge protector for control panel
257Cabling
258Complete cabling of tubewell including all power and control cables of all equipment at pump house and OHT
259Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments)
260NEW PUMPING PLANTfor Zone-3 Tw-1,2&3
261SITC of Submersible pump set 1500 LPM, 64m head (Tentative) with 24m column pipe,NRV,CI D/F Bend 90 ,CI A/F Tee, D/F pipe (1.5 m long 2 nos and 1.0 m long 1 no) Earthing ,Painting ,Toolset, Stablizer,wiring of pump house internal and external, Chain pulley block,and all Pumping plant accessories with nut bolts and rubber packing etc.(All other items for pumping plant item not included in SCADA Automation pumping plant items)
2623mtr heavy duty column pipe 150 mm dia (1 Set consist of 02 column pipe of 3mtr length each)
263Copper cable size 2x3cx6 sq mm. flat
2644 x 25 sq. mm Al. cable for power connection
265Automatic chlorination system compactable to SCADA system
266Soft starter with RS-485 port-400V Class 30 Kw rating or more suitable for pump set.
267Auto Phase reversal unit with inbuilt time delay and enclosure (125 Amp.)
268Motor operated actuator with sluice valve 150mm Sluice Valve
269CE & UL certified Inteligent Smart Energy Meter
270CE & UL certified Electro magnatice flow Meter 150mm size
271CE & UL certified hydro static type sub soil water level transmitter for tubewell.
272CE & UL certified pressure transmitter
273CE & UL certified Surge protector for control panel
274Complete cabling of tubewell including all power and control cables of all equipment at pump house and OHT
275Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments)
276SCADA SYSTEM FOR PUMPING PLANTfor Zone-1,2&3
277SCADA Automation Items
278CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations
279G.S.M./G.P.R.S. based wireless communication with 4G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges
280CE & UL certified 7" HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter.
281Installation, commissioning & testing for one tubewell / OHT
282Trial run for 03 months period for one tubewell
283E&M Work for OHTforZone-1,2&3
284Motor operated actuator for existing sluice valve on exist OHTof 250mm size. Of Zone 1&2
285Motor operated actuator with sluice valve on new OHTof 350mm size. Of Zone 3
286Flow Meter on OHT delivery line of size 250 mm dia for exist OHT of Zone 1&2
287Flow Meter on OHT delivery line of size 350 mm dia for new OHT of Zone 3
288CE/UL certified Radar type Level Transmitter forOver head Tank
289Chlorine Analyzer rnge 0-5ppm (electrolyte with membrane cap; Type- Amperometric.
290SCADA OF OHTforZone-1,2&3
291CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each ZPS/ OHTto store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations FOR STANDALONE OHT
292G.S.M./G.P.R.S. based wireless communication with 4G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges.
293CE/UL certified 03 KVA UPS with batteries at each OHT for proper working of actuator valve and other SCADA items At the time of electricity failure
294MASTER CONTROL CENTRE (MCS)
295CE/UL & BIS Certifed industrial grade LED MONITOR with latest configuration
296(i) 65" (upto 50 Tubewells).
297Desktop/PC with i5/i7 processor for as per spec mentioned in technical bid documents
298CE/UL Certified 3KVA UPS with batteries .
299Full development version of required TAGS SCADA Software with coustomization of sowftware for MCS as per requirement .
300CE/UL Certified master control room PLC with redundant CPU & power supply at MCS in IP54 enclouser
301CE/UL Certified Field gateway agent for transfering data from MCS to Central control room.
302GSM based wireless/Broaband/Equipment communication system for PLC capable to transfer & received data & gather data from remote sites to control satation, All accessories included signal enhancer antenna along with running expences, till DLP.
303CE/UL Certified Firewall for network protection.
304SURGE PROTECTOR FOR ETHERNET communication protection.
305CE/UL certified industrial grade Ethernet Switch.
306Mobile App Facility system architecture (industries internet based & viewed through mobile apps for increased local & Remote Visibility).
307Canon/HP or equivalent Laser Printer 1018 or equivement.
308Security Sureillance IP camera with recorder (optional)
309Installion, Commissioning & testing including required furniture, A/c etc.
310Trial run of MCS for 03 months period
311Trial Run
312Trial Run for Tubewells of 03 No. Zones including Liquid Chlorine & Staff Operator / Technician (E/M) & Technician (Electronic) excluding electricity charges.