Rate Contract Of Ctvs Cardiac Items , Rate Contract Ofctvs Cardiac Items , Bileaflet Prosthetic Heart Valve With Pivot Guard ( I ) Bileaflet Prosthetic Heart Valve, Made Up Of Pyroytic Arbon ( Mitral And Aortic ) With Opening Angel Of 80 Degree Or More ( Ii ) It Should Have Pivot Guards, Less Leaflet Exposure Area. ( Iii ) It Should Have Minimal Gradient Across The Valve In Vitro And Vivo All Sizes From 17 Mm To 29 Mm In Aortic Position And 23 To 33 In Mitonl Position. ( Iv ) They Should Have Rotatable Ring To Give Optional Positioning Of Valve During Surgery. ( V ) They Should Be In Use Universally For More Than Fifteen Years ( To Give Their Time Tested Results ) ( Vi ) Acceptability By Cardiac Surgery All Over The World So As To Know About The Long Term Result Must Be Fda Approved. , Bileaflet Prosthetic Heart Valves With Open Pivot ( I ) The Valve Should Be Made Up Of Pyrolite Carbon ( Mitral And Aortic With Opening Angle Of 80 Degree Of More. ( Ii ) It Should Have Minimal Gradient Across The Valve In Vivo And In Vitro Among All Sizes ( Aortic 17 To 29 And Mitral 23-33 ) ( Iii ) The Housing Should Be Rotatable To Give Optional Positioning For Valve. ( Iv ) Should In Use Universally For More Than Fifteen Years And Acceptability By Cardiac By Cardiac Surgeon All Over The World So As To Know About The Long Term Results. ( V ) Must By Fda Approved Swing Ring Should Be Thin To Give Optimal Implantation Size ( Like Homodynamic Plus ) , Tilting Disc Prosthetic Heart Valve Pryloite Carbon Technology ( Mitral And Aortic ) ( I ) Low Prople Tilting Valve Should Have Disc Made Up Of Pyrolite Carbon, Opening Angle Should Be More Than 70 Degree ( Ii ) Should Have Sufficient Back Wash To Minimize The Risk Ofvalve Thromboses ( Iii ) Single Piece Housing Will Be Preferably & Should Have Minimal Gradient Across Valve In Vivo And In Vitro ( Iv ) The Housing Should Be Rotatable To Give Optimal Positioning.It Should Have Mechanism To Rotate The Disc For Even Urban. ( V ) Should Be In Use Universally For More Than Fifteen Years And Acceptability By Cardiac Surgeon All Over The World So As To Know About Long Term Result. ( Vi ) Should Have All Sizes Available For Mitral And Aortic Position Must Be Fda Approved. / Ce Certified With 4 Digit Notified Body Number Product. ( Vii ) Indian Make Will Also Be Taken Into Consideration. , Ball Cage Prothetic Hert Valve ( I ) Ball Made Up Of Silicon Rubber Barium Impregnated Surgical Acceptable Sewing Ring. ( Ii ) Valve Should Be In Clinical Use All Over World For More Than15 Years With Better Results And Wide Acceptability By Cardiac Surgeons Must Be Fda Approved. , Stainless Tissue Heart Valve For Mitral And Aortic Position With All Sizes Available. Should Be In Clinical Use For More Than 10 Years With Long Term Good Results. , Free Style Tissue Heart Valves With Aortic Condmit ( I ) Should Be Available In All Sizes To Replace Aortic Root, Should Be Stentlen. ( Ii ) It Should Have Zero Pressure Preservation Technique To Give Long Term Durability. , Pericardial Tissue Valves It Should Be Available In All Sizes In Aortic And Mitral Position. It Should Have Long It Should Have Long Term Good Results And More Than 15 Years Durability In Vivo , Porcien Bio Prosthetic Heart Valves Should Have Excellent Homodynamic Large Flow Area. They Should Have Zero Pressure Fixation, Low Profile Stent. They Should Have World Wide Acceptability More Than 15 Years Sizes Aortic 21-29, Mitral 25-33 , Conduct Prosthetic Valves To Replace Aortic Root Prosthetic Valves Of Tilting Disc Mono Leaflet Or Bilejet Variety ( As Specifications Given For Metallic Valves ) Should Be Available In All Sizes Should Be Fd Approved. , Annuoplaty Rings For Mitral And Tricuspid Valves Both Types- A ) Flexible, B ) Rigid Are Acceptable Depend On Anatomy Should Be Available In All Sizes And Time Tested. , Cardic Pathces For Root Widening Teflon Feld A ) 5Cmx7.5Cmb ) 5Cmx15cm Polytatra Flouroethy Line Thin And Thick All Sizes Dacron Patches Single And Double Velore 10Cmx10cm Teflon Patches And Bovine Pericardial Patecles. , Aortic Perfusion Cannula Of Different Sizes 16 Fr., 18 Fr., 20 Fr., 22 Fr., 24 Fr.Should Have In-Built Proximal Connection, Non Wirere-Enforced, And Wire Enforced With Adjustable Guard. Plastic Curve Tips , Armour Endotracle Tube All Size , Balloons For Intra-Aortic Balloon Pump – 34 Fr. To 40 Fr. With Sheath , Coronary Loop Suture , B ) Bifuracted ( Ring Re Enforced ) ( Size 14 / 7, 16 / 7 ) , Disposable Coronary Artery Probes :- 1.6 Mm, 1.5 Mm, 2.0 Mm, 2.5 Mm , Disposable Internal Mammary Artery Cannula To Perfuse I.M.A. , Minimal Invasive Disposable Aortic And Venous Cannula , Retrograde Cardioplegia Cannula Adult And Paediatric Size A ) Wire Re-Enforced, Should Have Additional Limb To Check The Delivery Pressure. , Pacing Wire For Atrial And Ventricular Should Have Self Retaining Device. , Pacmaker Cell , Teflon Felt , Teflon Pledget , C ) Femoral Direct And Percutaneaus Arterial Cannula. , D ) Femoral Direct And Percutaneaus Venous Cannula. , Radiofrequency Probe ( Variclosure Endovenous Rf ) Vein Ablation Varicose For Vain ( Variclosure Endovenous Rf Make Machine Compatible ) , Centrifugal Disposable Pump ( Sorain ) Only , Inj Papaverine , Inj Sodium Nitroprusside , Inj Pentoxifylline , Inj Tissue Glue For Bronchial Fistula , Ntg Spray , Inj Sodium Tetradecylsulphate ( Setrol ) , Inj Amiodarone , Ptfe Hand Switch Disposable Pencil ( Amramya Cautery Smoke Evacautor )