Military Engineer Services-MES has published Tender For Repair And Replacement Of Window / Split Ac And Other Summer Appliances At Army And Af Area Under Ge Avadi. Submission Date for this Tender is 17-10-2023. Air Conditioner Tenders in avadi Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

39629319
Corrigendum : Tender For Repair And Replacement Of Window / Split Ac And Other Summer Appliances At Army And Af Area Under Ge Avadi
Open Tender
Indian
Tamil Nadu
avadi
17-10-2023

Tender Details

Repair And Replacement Of Window / Split Ac And Other Summer Appliances At Army And Af Area Under Ge Avadi

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 05-Oct-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 12-10-2023
2 12-Oct-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 17-10-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 92000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIR AND REPLACEMENT OF WINDOW/ SPLIT ACS AND OTHER SUMMER APPLIANCES AT ARMY AND AF AREA UNDER GE AVADI
Sl. No. Item Description
1Supply &Fix for Sub main wiring with 2 x 2.5 Sqmm size PVC insulated unsheathed single core multistranded copper conductor cable ISI marked for working voltage 1100 volts grade, drawn in toand includingPVCconduit and conduit accessories , including 2.5 sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to earth dolly and to be terminated and including taking down the old wiring complete all as specified and as directed.
2Supply &Fix for Sub main wiring with 2x 4 Sqmm size PVC insulated unsheathed single core multistranded copper conductor cable ISI marked for working voltage 1100 volts grade, drawn in toand includingPVCconduit and conduit accessories , including 4.0 sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to earth dolly and to be terminated and including taking down the old wiring complete all as specified and as directed.
3Supply &Fix for Sub main wiring with 2x 6 Sqmm size PVC insulated unsheathed single core multistranded copper conductor cable ISI marked for working voltage 1100 volts grade, drawn in toand includingPVCconduit and conduit accessories , including 6.0 sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to earth dolly and to be terminated and including taking down the old wiring complete all as specified and as directed.
4Supply & fixing single pole andneutral metal enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 A including taking down the old enclosure
5Taking down the existing unserviceable switch socket outlet 2 in 1, 3 pin, 6 and 16 A flush type universal and taken on credit and replacing with new 2 in 1 16A flush type socket complete all as specified and as directed.
6Supply and fix in repairs15 A plug top for water cooler, refrigerator,and geyser
7Supply and fix in repairs 15 A metal glad plug top for water cooler, refrigerator,and geyser
8Supply and fix in repairsswitch piano, flush type single pole one way 16 Amps
9Supplyand fixin repairs socket outletpiano, flush type 3 pin,16 Amps
10Supplyand fixin repairsmodularswitchone way 16 Amps 1 module
11Supplyand fixin repairs modular socket 6A / 16A - 2 / 3 pin combined 2 module.
12Taking down the existing unserviceable PVC 3 core 2.5 sqmm copper cable and taken on credit and replacing with new PVC 3 core 2.5 sqmm copper cable suitable for Water cooler / Refrigerator / Deepfreezer complete all as specified and as directed.
13Taking down the existing unserviceable PVC 3 core 4 sqmm copper cable and taken on credit and replacing with new PVC 3 core 4 sqmm copper cable suitable for Split AC /Geyser complete all as specified and as directed.
14Taking down the existing unserviceable MCB SP 5A to 32A and taken on credit and replacing with new MCB SP 5A to 32A suitable for Split AC complete all as specified and as directed.
15Taking down electricwater heater/ geysers of capacity 25ltrs from its mounting place for repair, re-assembling and refixing the same after repair and testing complete all as specified and as directed by Engineer-in-charge.
16All as per srl item No.15 here in before geyser of capacity 50 ltrs Note :- (i) 15 & 16 spares Items replaced shall be measured separatly. (ii)Any damage if ooccured during the process of cleaning the geyser will be made good by contactor at no extra cost.
17S&F in replacement of heating element of 1.5 KW ratingdouble tube typewith cup type of circular /traingle shape includingrubber washerssuitable to fitin the existing geyser without any water leakage completeall as specified and as directed by Engr-in-Charge .
18S&F in replacement of heating element of 2 KW ratingdouble tube typewith cup type of circular /traingle shape includingrubber washerssuitable to fitin the existing geyser without any water leakage completeall as specified and as directed by Engr-in-Charge .
19S&F in replacement of the heat proof rubber PVC gasket suitable for the different make of 25 litres capacitygeysers as per side requirement complete, all as specified and as directed by Engr-in-Charge-.
20All as per item No. 19 here in before but suitable for capacity 50ltrs.
21S&F apparatus plate (Geysers assembly) suitable for existing Geysers of Cap 25 Leters of copper r/brash complete with nuts and bolts and rubber washer complete all as specified and directed
22S&F apparatusplate (Geysers assembly) suitable for existing Geysers of Cap 50 Leters complete with nuts and bolts and rubber washer complete all as specified and directed
23S&F in replacement of vertical non return valve 15 mm dia GM as per site requirement complete, all as specified and as directed by Engr-in-Charge . ISI mark
24S&Fstainless steelinner tank 18 gauge heavy duty in replacement of steel inner tankhaving pressure bearing capacity 4Kg/Cm.sq. suitable tothe existing25 ltrscapacity geysers. complete, all as specified and as directed by Engr-in-Charge .
25S&Fcopperinner tank 18 gauge heavy duty in replacement of copper inner tankhaving pressure bearing capacity 4Kg/Cm.sq. suitable tothe existing25 ltrscapacity geysers. complete, all as specified and as directed by Engr-in-Charge .
26S&Fstainless steelinner tank 18 gauge heavy duty in replacement of steel inner tankhaving pressure bearing capacity 4Kg/Cm.sq. suitable tothe existing50 ltrscapacity geysers. complete, all as specified and as directed by Engr-in-Charge .
27All as per serial items No 26 here in before but copper inner tank suitable for 50 ltrscapacity geysers.
28S&F in replacement the thermostat for the geysers 25Ltrs capacity as per site requirement complete, all as specified and as directed by Engr-in-Charge .
29All as per serial items No 28 here in before but suitable for 50 ltrscapacity geysers.
30S&F in replacement of safety valve/high pressure valve 15mm,as per side requirement completeall as specified and as directed by Engr-in-Charge . ISI marked.
31Supply and fixing in replacement of theinsulatingmaterial i. e. glass wool. complete, all as specified and as directed by Engr-in-Charge .
32S&F in replacement chromium plate copper connecting pipe 450 mm long with two brass nut and nylon washer suitable for 15mmdia pipe and connecting up complete, all as specified and as directed by Engr-in-Charge .
33S&F in replacement heavy duty braided PVC connecting pipe with brass adapters 450 mm long suitable for 15 mm dia pipe and fixing in position all as approved by Engineer-in-charge.Make :Havells/Prayg.
34S&F in replacement heavy duty braided PVC connecting pipe with brass adapters 600 mm long suitable for 15 mm dia pipe and fixing in position all as approved by Engineer-in-charge. Make :Havells/Prayg.
35S&F in replacement of top cover made of M S sheet 18 SWG duly painted with two coats of super enamel paint by spray painting suitable for25 ltrsgeysers. complete, all as specified and as directed by Engr-in-Charge .
36All as per serial items No 35 here in before but50litres geysers.
37S&F in replacementsuitable fastner not less than 100 mm for geyserincluding making good to disturbed surface of wall and maching existing surface and finishingcomplete all as specified and as directedin Engr – in- Charge.
38S&F in replacement of split inspection bottom cover made of M S sheet 20 SWG duly painted with two coats of super enamel paint by spray painting complete all as specified and as directedin Engr – in- Chargesuitable for 25 ltrsgeysers.
39All as per serial items No 38here in before but50litres geysers.
40S&F in replacement of indicating lamp Red or Green as per Geyser suitability complete all as specified and as directed by Engr In Charge
41Testing the leakagein system, arresting the leakby vacumising the system, dehydration andcharging therefrigerent R-22 /R-32 into the system including replacement of strainer and capillary tube made out of copper complete suitable for 1.5 TonWindow Air conditioner all as directed by Engr-in-charge.
42Testing the leakagein system, arresting the leakby vacumising the system, dehydration andcharging therefrigerent R-22 /R-32 into the system including replacement of strainer and capillary tube made out of copper complete suitable for 1.5 Ton Split Air conditioner all as directed by Engr-in-charge.
43Testing the leakagein system, arresting the leakby vacumising the system, dehydration andcharging therefrigerent R-22 /R-32 into the system including replacement of strainer and capillary tube made out of copper complete suitable for 2.0 Ton Split Air conditioner all as directed by Engr-in-charge.
44Taking down the existing unserviceable compressor sealed unit by disconnecting the incoming / out going refrigerant lines and taken on credit and replacing with new compressor sealed unit, reconnecting refrigerant lines, detection of leakage and arresting the same by welding / brazing, flushing vacuuming and charging with gas of required quantity, after dehydration as per standard practice, compressor suitable for water coolerof capacity 1.5 ton capacity any make / model complete all as specified and as directed.
45All as per item No. 44 above but suitable for 1.5 Ton capacity window Air Conditioner
46All as per item No. 44 above but suitable for 2.0 Ton capacity split window Air Conditioner
47Taking down the existing unserviceble Condenser coil and taken on credit and replacing with new Condenser coil suitable forSplit AC,1.5toncapacity of any make / model complete all as specified and as directed.
48Taking down the existing unserviceble Coolingcoil and taken on credit and replacing with new Coolingcoil suitable forSplit AC,1.5toncapacity of any make / model complete all as specified and as directed.
49Taking down the existing unserviceble Condenser coil and taken on credit and replacing with new Condenser coil suitable forWindow AC,1.5toncapacity of any make / model complete all as specified and as directed.
50Taking down the existing unserviceble Coolingcoil and taken on credit and replacing with new Cooling coil suitable forWindow AC,1.5toncapacity of any make / model complete all as specified and as directed.
51Taking down the existing unserviceble Condenser coil and taken on credit and replacing with new Condenser coil suitable forSplit AC,2.0toncapacity of any make / model complete all as specified and as directed.
52Taking down the existing unserviceble Coolingcoil and taken on credit and replacing with new Coolingcoil suitable forSplit AC,2.0toncapacity of any make / model complete all as specified and as directed.
53Removing and pump down the split AC of cap 1.5 Ton and refixing including shifting the same all as directed by Engr-in-charge.
54All as per the item 53above but2.0Ton capacity SplitAir conditioner
55Taking down the existing unserviceble indoor unit fan motor and taken on credit and replacing with new indoor unit fan motor suitable forSplit AC,1.5toncapacity of any make / model complete all as specified and as directed.
56All as per the item 55above but2.0Ton capacity SplitAir conditioner
57Taking down the existing unserviceble outdoor unit fan motor and taken on credit and replacing with new outdoor unit fan motor suitable forSplit AC,1.5toncapacity of any make / model complete all as specified and as directed.
58All as per the item 57above but2.0Ton capacity SplitAir conditioner
59Dismantling and taking down unserviceable fan motor, Supply and fix newfan motor for 1.5 Ton window AC all as directed by engr-in-charge.
60All as per the item 59above but2.0Ton capacity SplitAir conditioner
61Taking down the existing window type AC, 1.5 tonton capacity of any make / model from its position and cleaning the AC externally and servicing the AC including cleaning of condensor, filter, cooling coil, base bottom and fins, with soap water, checking of electrical wiring,ensure smooth functioningand re-install and reconnect the AC unit in its exising location after proper cleaning of the place and testing and commissioning complete all as specified and as directed.
62Servicing the split type AC, 1.5 tonton capacity of any make / modelcleaning the AC externally and servicing the AC including cleaning of condensor coil without removing the outdoor unit,and filter, cooling coil base bottom and fins,with soap water, checking of electrical wiring, after proper cleaning of the AC and testing and commissioning complete all as specified and as directed.
63All as per the item 62above but2.0Ton capacity SplitAir conditioner
64S&F in replacement PCB suitable for 1.5 / 2.0 TonACas per site requirement all as directed
65S& F in replacement of copper tubing set 1/4" and 1/2" suitable for Split AC incl PUF insulation and connected accessories complete all as directed
66S& F in replacement of copper tubing set 1/2" and 3/8" suitable for Split AC incl PUF insulation and connected accessories complete all as directed
67Supply and fix in replacement starting relay suitable for 1.5 / 2.0Ton A/C all as directed.
68Supply and fix in replacement wiring kit suitable for 1.5 / 2.0 Ton A/C all as directed
69Supply and fix in replacement running capacitor 36mfd 230/415 Voltall as directed .
70All as per item No. 69 but 50 mfd 230/415 all as directed
71Supply and fixi in replacement starting capacitor 80/100mfd 230/415 Volt
72S&F Pvc drain pipe size 15mm /20mm suitable for A Call as directed
73S&F PUF insulation for copper tubing suitable for splitAC all as directed
74Supply and filling refrigerent R-22, suitable for Window AC/water cooler of any type all as directed
75Supply and filling refrigerent R-32 suitable for SplitAC/water cooler of any type all as directed
76Taking down the existing unserviceble Over load Protector and taken on credit and replacing with new Over load Protector suitable for Window AC / Split AC,1.5 / 2.0ton capacity of any make / model complete all as specified and as directed.
77Taking down the existing unserviceble Thermostat switch and taken on credit and replacing with new Thermostat switch suitable for Window AC / Split AC,1.5 / 2.0 toncapacity of any make / model complete all as specified and as directed.
78Supply and fix unserviceable Remote control sensor and digital device complete set with remote suitable for split type AC, anycapacity.
79Supply and fix unserviceable Air filter suitable for window / Split type AC, 1.5 ton capacity.
80Supply and fix unserviceable Oscillating motor / device to change direction of air flow suitable for split type AC, 1.5 / 2.0 ton capacity.
81Supply and fix unserviceableMagnetic coil suitable for split type AC, 1.5 / 2.0 toncapacity.
82Taking down the existing unserviceble GI bracket including all accessories and taken on credit and replacing with new GI bracket including all accessories suitable to fix out door unit of split type AC, of any make / model complete all as specified and as directed
83Taking down the existing unserviceable compressor sealed unit by disconnecting the incoming / out going refrigerant lines and taken on credit and replacing with new compressor sealed unit, reconnecting refrigerant lines, detection of leakage and arresting the same by welding / brazing, flushing vacuuming and charging with gas of required quantity, after dehydration as per standard practice, compressor suitable for water coolerof capacity 80 ltrs any make / model complete all as specified and as directed.
84All as per item No. 83 above but suitable for 120 ltr cap water cooler
85All as per item No. 83 above but suitable for 150 ltr cap water cooler
86Taking down the existing unserviceble copper condenser coil and taken on credit and replacing with newopper condenser coil cap 80 ltrs water cooler of any make / model complete all as specified and as directed
87All as per item No. 86 above but suitable for 120 ltr cap water cooler
88All as per item No. 86 above but suitable for 150 ltr cap, water cooler
89Taking down the existing unserviceblecondenser fan motor and taken on credit and replacing with new condenser fan motor any capwater cooler of any make / model complete all as specified and as directed
90Taking down the existing unserviceable strainer and capillary tube and taken on credit and replacing with new strainer and capillary tube suitable for water coolerof any make / model / cap complete all as specified and as directed.
91Taking down the existing unserviceable short circuited wires and terminal clipsand taken on credit and replacing with new wires and terminal clips suitable for water coolerof any make / model / cap complete all as specified and as directed.
92Taking down the existing unserviceable PVC water inlet pipe and taken on credit and replacing with newPVC pipe, transparent,heavy duty 20mm dia water inlet pipe for water cooler complete all as specified and as directed.
93Taking down the existing unserviceable PVC pipe as drain out pipe and taken on credit and replacing with newPVC pipe, heavy duty 25mm dia drain out pipe laid on walls / floor for water cooler complete all as specified and as directed.
94Supply and fix unserviceable Starting Relay suitable for water cooler of any capacityall as directed
95S&F in replacement running capacitor cap 30 Mfd suitable for water cooler of any capacityall as directed
96S&F in replacement starting capacitor cap 60 to 80Mfd suitable for water cooler of any capacityall as directed
97All as per item No. 96 above butcap of 40 to 60 mfd .
98S&F in replacement thermostate switch suitable for water cooler of any capacityall as directed. .
99S&F in replacement OLP suitable for water cooler of any capacityall as directed.
100Supply and fix in replacement new fan motor suitable for water cooler any capacityall as directed.
101Supply and fix unserviceable chromiam coated brass bip Tap for water cooler 15mm size, straight type
102Supply and fix unserviceable chromiam coated brass bip Tap for water cooler 15mm size, angle type with round disc
103Supply and fix unserviceable drain tray (stainless Steel) for water cooler of any capacity
104Supply and fix unserviceable 15 mm ball valves high pressureof PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed and minium weight 142 gms. For water cooler
105Taking down the existing unserviceable compressor sealed unit by disconnecting the incoming / out going refrigerant lines and taken on credit and replacing with new compressor sealed unit, reconnecting refrigerant lines, detection of leakage and arresting the same by welding / brazing, flushing vacuuming and charging with gas of required quantity, after dehydration as per standard practice, compressor suitable for digital inverter refrigerator of any make / model and capacity 340 lits complete all as specified and as directed.
106All as per item No. 105 above but cap of Refrigerator 300 to 320 ltrs
107All as per item No. 105 above but cap of Refrigerator 210 to 285 ltrs
108Cutting thesuction/ discharge tubes ofthecompressor lineand Flushing, vacuuming and charging of water cooler of any make / modelwith refrigerantgas (R-12/R-404), after dehydration as per standard practice, including detection of leaks and arresting the same by welding/brazing complete cap of refrigerator 340 ltrsall as specified and as directed
109All as per item No. 108 above butcap of Refrigerator 300to 320 ltrs .
110All as per item No. 108 above butcap of Refrigerator 210 to 285 ltrs .
111Taking down the existing unserviceable digital electronic circuit board and taken on credit and replacing with new digital electronic circuit board suitable for digital inverter refrigerator of any make / model and capacity complete all as specified and as directed.
112Taking down the existing unserviceable strainer and capillary tube and taken on credit and replacing with new strainer and capillary tube suitable for refrigeratorof any capacityany make / model complete all as specified and as directed.
113Taking down the following existing spare parts and taken on credit and replacing with new spare parts suitable for refrigerators of any make / any capacity any model complete all as specified and as directed.
114Magnetic door gasket suitable for refrigerator of any capacity
115Freezer (cooling coil) suitable for refrigerator of any capacity
116Thermostat switch with knob
117Relay box type suitable for refrigerator of any capacity .
118Relay open type suitable for refrigerator of any capacity .
119Timer switch suitable for refrigerator of any capacity .
120Blower motor suitable for refrigerator of any capacity .
121Running capacitor 4 Mfd suitable for refrigerator.
122Pigmy lamp screw / pin type with holder suitable for refrigerator of any capacity .
123Taking down the existing unserviceable compressor sealed unit by disconnecting the incoming / out going refrigerant lines and taken on credit and replacing with new compressor sealed unit, reconnecting refrigerant lines, detection of leakage and arresting the same by welding / brazing, flushing vacuuming and charging with gas of required quantity, after dehydration as per standard practice, compressor suitable for Deep Freezer of capacity 300 to 320 lits of any make / model complete all as specified and as directed.
124All as per item No. 114 above but cap of Deep Freezer 400 to 425ltrs
125Taking down the existing unserviceable digital electronic circuit board and taken on credit and replacing with new digital electronic circuit board suitable for Deep freezer of any make / model and capacity complete all as specified and as directed.
126Taking down the following existing spare parts and taken on credit and replacing with new spare parts suitable for Deep freezers of any make / any capacity any model complete all as specified and as directed.
127Relay withOLP suitable for Deep freezer of any capacity .
128Thermostat switch suitable for Deep freezer of any capacity .
129Condensing motor suitable for Deep freezer any capacity .
130Starting capacitor 40 Mfd to 60 Mfd suitable for Deep freezer any capacity .
131Running capacitor 4 Mfd suitable for Deep freezer .
132Deep freezer door hinges with spring, screw etc suitable for freezer of any capacity .
133Taking down the existing unserviceable compressor sealed unit by disconnecting the incoming / out going refrigerant lines and taken on credit and replacing with new compressor sealed unit, reconnecting refrigerant lines, detection of leakage and arresting the same by welding / brazing, flushing vacuuming and charging with gas of required quantity, after dehydration as per standard practice, compressor suitable for Three phase ductable type Split AC, 5.5 ton capacity of any make / model complete all as specified and as directed.
134Testing the leakagein system, arresting the leakby vacumising the system, dehydration andcharging therefrigerent R-407A into the system including replacement of dryer filter complete suitable for 5.5 TR ductable type SplitAir conditioner all as directed by Engr-in-charge.
135Taking down the existing unserviceble Dischargevalve and taken on credit and replacing with new Discharge valve suitable for ductable type SplitAC 5.5 toncapacity of any make / model complete all as specified and as directed.
136Taking down the existing unserviceble Suction valve and taken on credit and replacing with new Suction valve suitable for ductable type Split AC 5.5 toncapacity of any make / model complete all as specified and as directed.
137Taking down the existing unserviceble Copper Condenser coil and taken on credit and replacing with new Copper Condenser coil suitable for ductable type Split AC 5.5 toncapacity of any make / model complete all as specified and as directed.
138Taking down the existing unserviceble Copper Evoperator coil and taken on credit and replacing with new Copper Evoperator coil suitable for ductabletype Split AC 5.5 toncapacity of any make / model complete all as specified and as directed.
139Taking down the existing unserviceble blower fan motor and taken on credit and replacing with new blower fan motor suitable for ductable type type SplitAC 5.5 toncapacity of any make / model complete all as specified and as directed.
140Supply and Top up of refrigerent gas R-407A of 5.5 ton ductabletype Split AC
141Taking down the following existing spare parts and taken on credit and replacing with new spare parts suitable for voltage stabilizers of capacity 5 kVA / 4 kVA / 3 KVAof any make / model complete all as specified and as directed.
142Main transformer
143Transistorised electronic relay.
144Electronic PC circuit plate having diodes, condensers etc.,
145High / low voltage cut-off relay
146Time delay relay
147Disconnecting and dismantling of RO plant of capacity 200LPH/ 250LPH / 500 LPHetc.,and servicing / overhauling, cleaning of sand / carbon / micro filter / membrane filmtech, check water leakage in filters and pipe, re-installing, reconnecting, testing and commissioning for proper and smooth functioning complete all as specified and as directed Note :-Spares as required shall be measured and paid separately.
148Taking down the following existing spare parts and taken on credit and replacing with new spare parts suitable for RO plant of capacity200LPH/ 250 LPH / 500 LPHcomplete all as specified and as directed.
149Raw water pump 0.50HP.
150Sand / carbon filter vessel 1054
151Sand bag 10 kg as 1 unit
152Fine Sand bag 10 kg as 1 unit
153Silex 10 kg as 1 unit
154Pebbles 10 kg as 1 unit
155Carbon bag 450IV 10 kg as 1 unit
156Multi port valve 20NB
157Dozing pump upto 500 LPH
15820 inch housing filter
15920 inch filter spun
16020 inch wound
161Antiscalant liquid
162High pressure pump (CRI) 2-100
16340-40 membrane housing
164End cup
165End cup "O" ring
166Saddles and straps
167Membrane (Filmtech), (hydro nautics)
168Membrane connecter
169Auto electric panel
170UPVC pipe 20mm dia and accessories
171Ultra violet media upto 500LPH
172Clip forUltra violet media
173Membrane cleaning liquid
174Disconnecting and dismantling of RO water purifier of capacity 15LPH / 50 LPHetc.,and servicing / overhauling, cleaning of sand / carbon / micro filter / membrane filmtech, check water leakage in filters and pipe, re-installing, reconnecting, testing and commissioning for proper and smooth functioning complete all as specified and as directed Note:- Spares as required shall be measured and paid separately.
175Taking down the following existing spare parts and taken on credit and replacing with new spare parts suitable for RO plant of capacity 15 LPH / 50 LPHcomplete all as specified and as directed.
176Carbon granules filter
1775-5 membrane and housing assembly .
178Pressure pump 48 V
179Adaptor 48 V
180Carbon black filter.
181Micron filter
182Taking down the unserviceable cable and Supply and laid in trenches / floors or fixed on wall forcable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 sq mm 4 core including fixcing materials like lugs, cable glands etc complete all as specified and directed.
183Excavation in trenches not exc 1.5m in width and 1.5 M in depth and getting out excavated soil soft/loose soil.
184Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25cm
185Removing excavated material / soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge.
186Supply and filling sand cushioning spreading levelling for cable trenches all as specified kand directed
187Supply and laying well burnt bricks sub class "B" in trenches for cable protection of U/G cable all as specified
188M&L Electrical Earthing complete with GI plate Electrode of size 60 Cm X 60 Cm X 6 mm thick burried directly inground vertically at a depth not less than 2.25 mtr. Below normal ground level, with top edge of earth plate at a depth not less than 1.5 mtr. below normal ground level , connected to galvanised earth lead with 4.0 mm thick GI wire by means of bolts, nuts and washers of galvanised iron , earth lead wire protected by means of 15 mm bore dia light grade GI pipe up to switch board / panel board , all as specified and shown in MES schedule Electrical Plate No:-5 of SSR Part I, including excavation and earth work in any type of soil , PCC 1 : 2 : 4 type C1 in chamber , RCC 1:2:4 type C1 40 mmthick cover slab with 6 mm dia MS bars at 100 mm centre to centre both ways,with 6 mm dia MS hook, Charcoaldust, salt , funnel for watering complete all as specified and as directed by Engr-in-Charge.
189Supply and fix Galvanised iron wire 4.0 mm as earth continuity conductor including fixing arrangement on suitable size insulator complete all as directed.