}

Tender For Repair/ Maint Of Pumps Motor, Cleaning Of Semi Underground Water Tanks And Replacement Of Water Supply Lines And Other Connected Works At Hq Cif (R) And Signal Regt Under Age (I) Cif (R)., Udhampur-Jammu And Kashmir

Military Engineer Services-MES has published Tender For Repair/ Maint Of Pumps Motor, Cleaning Of Semi Underground Water Tanks And Replacement Of Water Supply Lines And Other Connected Works At Hq Cif (R) And Signal Regt Under Age (I) Cif (R).. Submission Date for this Tender is 19-10-2023. Pump repair and Maintenance Tenders in Udhampur Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

39628410
Corrigendum : Tender For Repair/ Maint Of Pumps Motor, Cleaning Of Semi Underground Water Tanks And Replacement Of Water Supply Lines And Other Connected Works At Hq Cif (R) And Signal Regt Under Age (I) Cif (R).
Open Tender
Indian
Jammu And Kashmir
Udhampur
19-10-2023

Tender Details

Repair / Maint Of Pumps Motor, Cleaning Of Semi Underground Water Tanks And Replacement Of Water Supply Lines And Other Connected Works At Hq Cif ( R ) And Signal Regt Under Age ( I ) Cif ( R ) .

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 07-Oct-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 14-10-2023
2 14-Oct-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 19-10-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 15480.0 /-
Tender Value
INR 7.74 Lakhs /-

BOQ Items

Name of Work: REPAIR/ MAINT OF PUMPS MOTOR, CLEANING OF SEMI UNDERGROUND WATER TANKS AND REPLACEMENT OF WATER SUPPLY LINES AND OTHER CONNECTED WORKS AT HQ CIF (R) AND SIGNAL REGT UNDER AGE (I) CIF (R).
Sl. No. Item Description
1Excavation in trenches in soft/loose soil not exc 1.5m wide and n.exc 1.5m in depth for electric poles stay foundation, under ground electric power cables, water supply pipe lines and getting out, complete all as specified and directed.
2Returning, filling in, including spreading, levelling, watering and well ramming in layers n. exc 25 cm in any type of soil complete all as specified and directed.
3Removing surplus spoil to a distance not exceeding 50m and deposited where directed at a level not exceeding 1.50m from the starting point., all as specified .
4Sand cushioning to underground cables complete all as specified in clause 19.75 of SSR Part-I laid before and after laying of cable, complete all as specified.
5M&L for Brick covering with width equal to length of brick as mechanical protection to cables with well burnt sub class ‘B’ (old size) bricks laid dry flat, complete all as specified and directed.
6XLPE insulated, armoured, heavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 25 Sqmm 4 core laid in trenches or passing through pipes/ducts or fixed to walls/polesincluding taking down old u/s cable, complete all as specified. Note:-(Earth work, brick protection and sand cushioning shall be measured and paid for separately).
7XLPE insulated, armoured, heavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 70 Sqmm 3.5 core laid in trenches or passing through pipes/ducts or fixed to walls/polesincluding taking down old u/s cable, complete all as specified. Note:-(Earth work, brick protection and sand cushioning shall be measured and paid for separately).
8XLPE insulated, armoured, heavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 95 Sqmm 3.5 core laid in trenches or passing through pipes/ducts or fixed to walls/polesincluding taking down old u/s cable, complete all as specified. Note:-(Earth work, brick protection and sand cushioning shall be measured and paid for separately).
9Aluminium cable thimble of size 95 Sqmm for UG Cable including connection and crimping in replacement complete all as specified and directed .
10Aluminium cable thimble of size 50 Sqmm for UG Cable including connection and crimping in replacement complete all as specified and directed.
11Aluminium cable thimble of size 35 Sqmm for UG Cable including connection and crimping in replacement complete all as specified and directed.
12Aluminium cable thimble of size 25 Sqmm for UG Cable including connection and crimping in replacement complete all as specified and directed.
13Supply and fixing in replacementMCCB 250 Amps, four pole, 415 volt,50 Hz with breaking capacity 36 KA with adjustable thermal and fixed magnetic, complete all as specified and directed.
14Supply and fixing in replacementMCCB 200 Amps, four pole, 415 volt,50 Hz with breaking capacity 36 KA with adjustable thermal and fixed magnetic, complete all as specified and directed.
15Supply and fixing in replacementMCCB 160 Amps, four pole, 415 volt,50 Hz with breaking capacity 36 KA with adjustable thermal and fixed magnetic, complete all as specified and directed.
16Supply and fixing in replacementMCCB 100 Amps, four pole, 415 volt,50 Hz with breaking capacity 16 KA with adjustable thermal and fixed magnetic, complete all as specified and directed.
17Servicing the Reverse Osmosis Plant of output capacity 25 Litre per hour+UV water purification with ultraviolet disinfection with Arsenic, floride and chloride removal having 3 candles with micron filter/pre filter having particulate filter porosity 10 micro with pressure vessel dual media filter electrically operated semi automatic with external cut off operating voltage 230 Volts 50 Hz AC Supply including High Pressure pump , raw water/ chemical cleaning Pump and testing complete all as specified and directed by Engr In Charge.
18Taking out submersible pump and motor of capacity 2 HP from the tube well lowered at the depth of 90 to 110 mtr from the ground level including taking out HDPE pipes of completelength and one Nos submersible cable 2 core of any size incl disconnecting electrically and delivery out let pipe and lowering after complete repair and maint of the same complete as in order to start the submersible pump complete all as directed by Engr-in-charge
19Rewinding submersible motor 2 HP of01 Phase, 240 voltswith PVC insulated solid copper conductor (wire) superior quality of approved make, size & number of wire as per existing complete including replacement of worn out cable connections, spare partsincluding testing and commissioningof motor after rewinding complete all as specified. Note:- Spare parts shall be measured and paid separately under respactive items
20Supply only the following spare parts for submersible motor as per existing make and size :-
21GM Bearing Bush
22Rotor sleeve
23Water seal
24Thrust bearing
25Housing upper
26Housing lower
27Cable seal
28Thrust plate
29Coupling S/S
30Key for coupling
31LNK bolt S/S
32Revolving disc
33Seal bush
34Sand guard
35Opening and reassembling of submersible pump of capacity 2 HP and replacement of the worn out spare parts as mentioned under respective item no 19 here in after. Note:- Spare parts shall be measured and paid separately under respactive items
36Supply only the following spare parts forsubmersible pump as per existing make and size :- Make of pump
37Stage bowl
38Impellers
39Pump shaft S/S (single stage)
40Hook bolt (Upper & lower)
41GM neck ring
42Key for pump shaft (Each stage)
43Distance sleeve
44D.O.L Bush
45Sand guard
46Impeller key
47Inter ring
48Guide bush
49Suction chamber
50D.O.L. Sleeve
51Dismantling of existing defective induction motor of thesize 5 HP capacity any makefrom the foundation, disconnecting the electric connection, coupling pulley, and taking out to work shop cutting down and removing existing burnt out copper windings, cleaning of slots and rewinding with super enamelled solidcopper conductor ( winding wire) complete including varnishing, drying, ovening, overhauling, greasing and fixing in the same position, making necessary electric connection and testing of induction motor complete all as specified and as directed by Engineer-in-Charge.
52Dismantling of existing defective induction motor of thesize 20 HP capacity any makefrom the foundation, disconnecting the electric connection, coupling pulley, and taking out to work shop cutting down and removing existing burnt out copper windings, cleaning of slots and rewinding with super enamelled solidcopper conductor ( winding wire) complete including varnishing, drying, ovening, overhauling, greasing and fixing in the same position, making necessary electric connection and testing of induction motor complete all as specified and as directed by Engineer-in-Charge.
53Supply & Fix in replacement Single phase submersible pump set controller /starter for upto 2 HP submersible pump set with suitable cap starting & running capacitors, complete all as specified and directed by Engr-in-Charge. Make:-L&T Model MU-G6 DOL or equivalent make as specified in list of make here-in-after.
54Supply & Fix in replacement three phase starter for20 HPpump setstarting & running, complete all as specified and directed by Engr-in-Charge. Make:-Havells Cat. No.IHHASDUBor equivalent make as specified in list of make here-in-after.
55Supply & Fix in replacement three phase starter for30 HPpump setstarting & running, complete all as specified and directed by Engr-in-Charge. Make:-Havells Cat. No.IHHASDWBor equivalent make as specified in list of make here-in-after.
56Taking up or down GI tubing including connections carefully,for relaying or removal to store all as directed andspecified by Engr - in - Charge of following size. Note- Excavation and earth work shall measured and paid saperately under relativeitem.
5725 mm dia bore
5840 mm dia bore
5950 mm dia bore
60S&F 25 mm bore steel water tubing "medium grade" galvanised with all fitting (i.e. Tee, socket, bend etc) laid in trenches, complete all as specified and directed by Engr-in-Charge.
61S&F 40 mm bore steel water tubing "medium grade" galvanised with all fitting (i.e. Tee, socket, bend etc) laid in trenches, complete all as specified and directed by Engr-in-Charge.
62S&F 50 mm bore steel water tubing "medium grade" galvanised with all fitting (i.e. Tee, socket, bend etc) laid in trenches, complete all as specified and directed by Engr-in-Charge.
63S&F 80 mm bore steel water tubing "medium grade" galvanised with all fitting (i.e. Tee, socket, bend etc) laid in trenches, complete all as specified and directed by Engr-in-Charge.
64S & F in replacement of cast iron sluice valve 80 mm dia both side flanged PN-1.6 confirming to IS 14846 (ISI marked) with stainless steel spindle and iron wheel non raising type including, nuts and bolts, complete all as specified and directed by Engr-in-Charge.
65Supply and fix in repair gun metal gate valve20 mm bore with iron wheel screwed both ends for iron pipes complete all as specified and directed.
66Supply and fix in repair gun metal gate valve25 mm bore with iron wheel screwed both ends for iron pipes complete all as specified and directed.
67M&L dewatering, cleaning of reservoirs with high pressure jet incl lime wash internally complete incl Writing of the date of cleaning of the water tankall as directed as under for the following. (i) Dewatering the tank with portable submersible pump set. (ii) Removal of left over dirty water and sludge with special sludge removal pump set . (iii) Cleaning of wall ceiling and floor by high pressure rotary water jet . (iv)Removing of remaining sludge from the floor with the help of industrial vacuum cleaner. (v)Spraying of non toxic biodegraded eco friendly anti bacterial agent certified by a Govt approved lab to disinfect the tank from harmful bacteria. (vi) Epoxy Paint two coats on external and internal surfaces after removing/ scraping old distemper complete
6870,000 Ltrs capacity U/G sump at Main Pump House
6935,000 Ltrs capacity U/G sump at Gate No 01
70Supply, fabricating and installing of perforated M.S. cable trays of size 50 x 200 x 2 mm thick including horizontal and vertical bends, reducers, tees, cross members and other accessories as required, and duly suspended from the ceiling with M.S. suspenders, including painting, complete all as specified and directed by Engr-in-Charge.
71M&Lof sub main wiring with four run of single core PVC insulated FRLSH stranded copper conductor cable of size 10 Sq mm and two run of 10 Sq mm PVC insulated FRLSH copper conductor cable as earth continuity conductordrawn in and including PVC casing and caping with necessary accessories complete all as directed. Note : 4 Runs of 10 sqmm cable and two run of 10.00 sqmm earth wire with PVC casing and caping shall be measured as one length.
72Supplying & laying in trencies 32mm outside dia CPVC pipes shedule -80, IS 4985 for potable waterincludin all Crimp type internal sealing Plastic-Metal Composite fittings (such as elbows, tees, reducers, etc.), complete all as specified and directed by Engr-in-Charge.
73Taking out submersible pump and motor of capacity 7.5 HP from the tube well lowered at the depth of 90 to 110 mtr from the ground level including taking out 50 mm MS pipes of completelength and one Nos submersible cable 3 core of any size incl disconnecting electrically and delivery out let pipe and lowering after complete repair and maint of the same complete as in order to start the submersible pump complete all as directed by Engr-in-charge
74Rewinding submersible motor 7.5 HP of03 Phase, 415 voltswith PVC insulated solid copper conductor (wire) superior quality of approved make, size & number of wire as per existing complete including replacement of worn out cable connections, spare partsincluding testing and commissioningof motor after rewinding complete all as specified. Note:- Spare parts shall be measured and paid separately under respactive items
75Supply only the following spare parts for submersible motor as per existing make and size :-
76GM Bearing Bush
77Rotor sleeve
78Water seal
79Thrust bearing
80Housing upper
81Housing lower
82Cable seal
83Thrust plate
84Coupling S/S
85Key for coupling
86LNK bolt S/S
87Revolving disc
88Seal bush
89Sand guard
90Opening and reassembling of submersible pump of capacity 7.5 HP and replacement of the worn out spare parts as mentioned under respective item no 42 here in after. Note:- Spare parts shall be measured and paid separately under respactive items
91Supply only the following spare parts forsubmersible pump as per existing make and size :- Make of pump
92Stage bowl
93Impellers
94Pump shaft S/S (single stage)
95Hook bolt (Upper & lower)
96GM neck ring
97Key for pump shaft (Each stage)
98Distance sleeve
99D.O.L Bush
100Sand guard
101Impeller key
102Inter ring
103Guide bush
104Suction chamber
105D.O.L. Sleeve
106M&L water sample testing, water sample collecting from water point, B5 Post Bore well, C1 Post Bore well, C2 Post Bore well and Main Pump house water tank.Water shall be tested from Govt Authorised Labs for the following parameters and testing report to be submitted to the Engr-in-Charge in triplicate :- (a) Water testing shall be done as Pe IS: 10500:2012 : Colour, Odour, Taste, Turbidity, pH, Total Dissoloved Solids, Total hardness (as CaCO3), Calcium (as Ca), Magnesium (as Mg), Chloride (as Cl), Sulphate (as SO4), Iron (as Fe), Residual Free Chlorine (as Cl2), Copper as (Cu), Manganese (as Mn), Nitrate (as NO3), Fluride (as F), Phenolic Compound (as C6H5OH), Mercury (as Hg), Cadmium (as Cd), Selenium (as Se), Arsenic (as As), Cyanide (as CN), Lead (as Pb), Zinc (as Zn), Anionic Detergents (as MBAS), Total Alkalinity (as CaCO3), Aluminium (as Al) Boron (as B), Mineral Oil, Barium (as Ba), Chloramines (as Cl2), Silver (as Ag), Sulphide (as H2S), Molybdenum (as MO), Nickel as (Ni), Total Chromium (as Cr), Ammonia (as Total Ammonia-N, E, Coil), Total Coliforms, Ploynuclear Aromatic, Hydeocarbons (as PAH), Polychlorinated Biphenyls, Pesticides, Alachlor, Atrazine, Aldrin, Dieldrin, Alpha MCH, Beta HCH, Gamma-HCH (Lindane), Delta HCH, Butachlor, Chlorpyrifos, 2, 4-Dichlorophenoxy Acetic Acid,2, 4, DDT, 4,4 DDT, 2,4 DDD, 4,4 DDD, 2,4 DDE, 4,4 DDE, Endosulfan, Endosulfan-1, Endosulfan-II, Ethion, Isoproturon, Malathion, Methyl Parathion, Monocrotophos, Phorate, Trichloromethane, Bromofrom, Dibromochloromethan, Bromodichloromethane, Chloroform.
107Supply & Fix in replacement three phase starter for7.5 HPSubmersible pump setstarting & runningcomplete all as specified.
108S & F in replacement of gland dori8mm to 12.5mm dia, complete all as specified and directed by Engr-in-Charge.
109S & F in replacement of rubber coupling any size/tyre flaxible suitable for 5 HP to 30 HP pump motor, complete all as specified and directed by Engr-in-Charge.
110Supply only calcium Hypo Chlorite granular in factory sealed HDPE container (45 Kg each) decomposing at 177 C , Mol Wt : 142.98, Toxicity: Oral rat LD : 850mg /kg having chlorination concentration level 70%, complete all as specified and directed. Make- Puri Chlor (Sree Rayalaseema Hi-Strength Hypo Ltd) or equivelent make as approved byEngr-in-Charge (E-in-C"s Branch approved brand only).
111S & F in replacement three phase starter for 5 HP pump set starting & running, complete all as specified and directed by Engr-in-Charge.
112S & F in replacement GI nut bolts, washera any size, complete all as specified and directed by Engr-in-Charge.
113Supply & Fix in replacement three phase starter for12.5 HP submersible pumpmotor setstarting & runningcomplete all as specified. Make:-Havells Cat. No.IHSDOAM1*Aor equivalent make as specified in list of make here-in-after.
114Servicing the Reverse Osmosis Plant of output capacity 500 Litre per hour+UV water purification with ultraviolet disinfection with Arsenic, floride and chloride removal having 3 candles with micron filter/pre filter having particulate filter porosity 10 micro with pressure vessel dual media filter electrically operated semi automatic with external cut off operating voltage 230 Volts 50 Hz AC Supply including High Pressure pump , raw water/ chemical cleaning Pump and testing complete all as specified and directed by Engr In Charge.
115Deduction to be made from BOQ for schedule of credit (Sch "A" Part - II) Amount of ? 27,895.00during AOC Note:- Tenderers shall not quote for this Schedule
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail