Tender For Upgradation Of Commercial Estate Morigaon
Tender Value
1.89 Crore
Estimated cost
Bid Submission
03 Oct 2023
0 days left
EMD
3.78 Lakhs
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
morigaon → Assam
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Upgradation Of Commercial Estate Morigaon
BOQ
| Sl. No. | Item Description |
| 1 | Civil Work |
| 2 | PILE WORK |
| 3 | Providing, driving with hydraulic piling rigs with power units and installing driven cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carrysafe working load not less than specified, excluding the cost of steel reinforcement but including the cost of shoe and the length of pile to be embedded in the pile cap etc. all complete. (Length of pile for payment shall be measured from top of shoe to the bottom of pile cap) : |
| 4 | 400 mm dia piles |
| 5 | Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge.Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing.Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge. |
| 6 | Single pile upto 50 tonne Safe capacity |
| 7 | Initial test (Test Load 2.5 times the Safe capacity) |
| 8 | Routine test (Test Load 1.5 times the Safe capacity) |
| 9 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 10 | EARTH WORK |
| 11 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. |
| 12 | All kinds of soil |
| 13 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 14 | Supplying and filling in plinth with sand under floors, including watering ramming, consolidating and dressing complete. |
| 15 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : |
| 16 | Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete: |
| 17 | With Chlorpyriphos/ Lindane E.C. 20% with 1%concentration |
| 18 | Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.: |
| 19 | 2.35.2.1 With Chlorpyriphos/ Lindane E.C. 20% with 1%concentration |
| 20 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drillin 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: |
| 21 | With Chlorpyriphos/Lindane E.C. 20% with 1%concentration |
| 22 | CONCRETE WORK |
| 23 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 24 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stoneaggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 25 | REINFORCED CEMENT CONCRETE |
| 26 | CAST IN SITU |
| 27 | Providing and laying in position specified grade of reinforced cemen concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
| 28 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 29 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing andreinforcement : |
| 30 | 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 31 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels,bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarsesand(zone-III) derived from natural sources : 3 graded stone aggregat 20 mm nominal size derived from natural sources). |
| 32 | STEEL REINFORCEMENT |
| 33 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 34 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 35 | Steel reinforcement for R.C.C. work including straightening, cutting bending, placing in position and binding all complete above plinth level. |
| 36 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 37 | FORM WORK |
| 38 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 39 | Foundations, footings, bases of columns, etc. for mass concrete |
| 40 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 41 | Suspended floors, roofs, landings, balconies and access platform |
| 42 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 43 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 44 | Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additionalheight of 1 metre or part thereof (Plan area to be measured). |
| 45 | Suspended floors, roofs, landing, beams and balconie (Plan area to be measured) |
| 46 | MASONRY WORK |
| 47 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
| 48 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 49 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level inall shapes and sizes in : |
| 50 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 51 | CEMENT PLASTER (IN FINE SAND) |
| 52 | 12 mm cement plaster of mix : |
| 53 | 1:4 (1 cement: 4 fine sand) |
| 54 | 15 mm cement plaster on the rough side of single or half brick wall of mix: |
| 55 | 1:4 (1 cement: 4 fine sand) |
| 56 | Providing and applying plaster of paris putty of 2 mm thickness overplastered surface to prepare the surface even and smooth complete. |
| 57 | Applying one coat of water thinnable cement primer of approved brandand manufacture on wall surface : |
| 58 | Water thinnable cement primer |
| 59 | Finishing walls with textured exterior paint of required shade : |
| 60 | New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 61 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : |
| 62 | Two or more coats on new work |
| 63 | Applying priming coat: |
| 64 | With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 65 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : |
| 66 | Two or more coats applied on walls @ 1.25 ltr/10 sqmover and including one coat of Special primer applied @0.75 ltr /10 sqm |
| 67 | Applying priming coat: |
| 68 | With ready mixed red oxide zinc chromate primer ofapproved brand and manufacture on steel galvanised iron/ steel works |
| 69 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : |
| 70 | Painting Steel work with Deluxe Multi Surface Paint togive an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 71 | FLOORING |
| 72 | VITRIFIED FLOOR TILES |
| 73 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08%and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement:4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. Thetiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 74 | Glazed vitrified floor tiles polished finish of size |
| 75 | Size of Tile 1200 x 1200 mm |
| 76 | Glazed Vitrified tiles Matt/Antiskid finish of size |
| 77 | Size of Tile 600 x 1200 mm |
| 78 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of stepsand dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shadecomplete. |
| 79 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building allcomplete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with whitecement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and asdirected by the Engineer-in-Charge. |
| 80 | Polished Granite stone slab colour of Black, Cherry/Rub Red or equivalent |
| 81 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs ordash fastener shall be paid for separately). |
| 82 | Second class teak wood |
| 83 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 plyveneering with vertical grains or cross bands and face veneers on both faces of shutters: |
| 84 | 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 85 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). |
| 86 | Providing & Fixing decorative high pressure laminated sheet of plain /wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conformingto IS : 2046 Type S, including cost of adhesive of approved quality. |
| 87 | 1.5 mm thick |
| 88 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screwsetc. complete : |
| 89 | 300x16 mm |
| 90 | 250x16 mm |
| 91 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). |
| 92 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), withnecessary accessories and screws etc. complete. |
| 93 | Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providingEPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete. |
| 94 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length andjointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. |
| 95 | 80x1.25 mm M.S. laths with 1.25 mm thick top cover |
| 96 | Providing and fixing ball bearing for rolling shutters. |
| 97 | Extra for providing mechanical device chain and crank operation foroperating rolling shutters. |
| 98 | Exceeding 16.80 sqm in area |
| 99 | Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer-in- charge,(area of grill to be measured). |
| 100 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 101 | Fixed to openings /wooden frames with rawl plugs screws etc. |
| 102 | 12 mm cement plaster finished with a floating coat of neat cement of mix : |
| 103 | 1:4 (1 cement: 4 fine sand) |
| 104 | Providing & fixing at all heights, levels and locations colour finish Aluminium alloy roofing sheets of alloy IS designation 31500, temper Hx8 conforming to IS 737 and dimensions as per IS code 2676 with characteristics of good formability and corrosion resistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex cap headed self drilling/tapping Stainlesssteel screws M6, 50 mm long with 3 mm EPDM seal washer etc. all inclusive of labour, scaffolding, T&P and sundries etc. complete as per directions of the Engineer-In-Charge. (Cost of truss/frame workshall be paid separately). |
| 105 | SANITARY & WATER SUPPLY WORKS |
| 106 | Providing and fixing vitreous china dual purpose closet suitable foruse as squatting pan or European type water closet (Anglo IndianW.C pan) with seat & lid fixed with C.P. brass hinges and rubberbuffers, 10 litre low level flushing cistern with fitting and brackets, 40mm flush bend, 20 mm over flow pipe, with specials of standardmake and mosquito proof coupling of approved municipal designcomplete, including painting of fittings and brackets, cutting andmaking good the walls and floors wherever required: |
| 107 | White vitreous china dual purpose WC pan with whitesolid plastic seat and lid with white vitreous china flushingcistern and C.P. flush bend. |
| 108 | Providing and fixing white vitreous china flat back half stall urinal ofsize 580x380x350 mm with white PVC automatic flushing cistern,with fittings, standard size C.P. brass flush pipe, spreaders withunions and clamps (all in C.P. brass) with waste fitting as per IS :2556, C.I. trap with outlet grating and other couplings in C.P. brass,including painting of fittings and cutting and making good the wallsand floors wherever required : |
| 109 | Single half stall urinal with 5 litre P.V.C. automaticflushing cistern |
| 110 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CPBrass single hole basin mixer of approved quality and make, includingpainting of fittings and brackets, cutting and making good the wallswherever required:- |
| 111 | (a) White Vitreous China Wash basin size 550x400 mm with a15 mm CP Brass single hole basin mixer |
| 112 | Providing and fixing CP Brass 32mm size Bottle Trap of approvedquality & make and as per the direction of Engineer-in-charge. |
| 113 | Providing and fixing P.V.C. waste pipe for sink or wash basin includingP.V.C. waste fittings complete. |
| 114 | Semi rigid pipe |
| 115 | 40 mm dia |
| 116 | Providing and fixing 600x450 mm beveled edge mirror of superiorglass (of approved quality) complete with 6 mm thick hard boardground fixed to wooden cleats with C.P. brass screws and washerscomplete. |
| 117 | Providing and fixing toilet paper holder : |
| 118 | C.P. brass |
| 119 | 18.51 Providing and fixing C.P. brass long body bib cock of approved qualityconforming to IS standards and weighing not less than 690 gms.18.51.1 15 mm nominal bore |
| 120 | 15 mm nominal bore |
| 121 | Providing and fixing C.P. brass stop cock (concealed) of standarddesign and of approved make conforming to IS:8931. |
| 122 | 15 mm nominal bore |
| 123 | Providing and fixing C.P. brass angle valve for basin mixer and geyserpoints of approved quality conforming to IS:8931 |
| 124 | 15mm nominal bore |
| 125 | Providing and fixing PTMT liquid soap container 109 mm wide, 125mm high and 112 mm distance from wall of standard shape withbracket of the same materials with snap fittings of approved qualityand colour, weighing not less than 105 gms. |
| 126 | Providing and fixing PTMT Waste Coupling for wash basin and sink,of approved quality and colour. |
| 127 | Waste coupling 38 mm dia of 83 mm length and 77mmbreadth, weighing not less than 60 gms |
| 128 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVCplain & brass threaded fittings This includes jointing of pipes & fittingswith one step CPVC solvent cement, trenching, refilling & testing ofjoints complete as per direction of Engineer in Charge. |
| 129 | External work |
| 130 | 25 mm nominal dia Pipes |
| 131 | 32 mm nominal dia Pipes |
| 132 | 40 mm nominal dia Pipes |
| 133 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps,i/c cutting and making good the walls etc. |
| 134 | Internal work - Exposed on wall |
| 135 | 15 mm dia nominal bore |
| 136 | 25 mm dia nominal bore |
| 137 | Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, IS : 12701 marked, with cover and suitable lockingarrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank. |
| 138 | Boring/drilling bore well of required dia for casing/ strainer pipe, bysuitable method prescribed in IS: 2800 (part I), including collectingsamples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools,plants & machineries required for the job, all complete as per directionof Engineer-in-charge, upto 90 metre depth below ground level. |
| 139 | All types of soil |
| 140 | 300 mm dia |
| 141 | Supplying, assembling, lowering and fixing in vertical position in borewell, unplasticized PVC medium well casing (CM) pipe of requireddia, conforming to IS: 12818, including required hire and labourcharges, fittings & accessories etc. all complete, for all depths, asper direction of Engineer -in-charge. |
| 142 | 200 mm nominal size dia |
| 143 | Supplying, assembling, lowering and fixing in vertical position in borewell unplasticized PVC medium well screen (RMS) pipes with ribs,conforming to IS: 12818, including hire & labour charges, fittings &accessories etc. all complete, for all depths, as per direction ofEngineer-in-charge. |
| 144 | 200 mm nominal size dia |
| 145 | Gravel packing in tubewell construction in accordance with IS: 4097,including providing gravel fine/ medium/ coarse, in required grading& sizes as per actual requirement, all complete as per direction ofEngineer-in-charge. |
| 146 | Development of tube well in accordance with IS : 2800 (part I) and IS:11189, to establish maximum rate of usable water yield without sandcontent (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well is fullydeveloped, measuring yield of well by \"V\" notch method or any otherapproved method, measuring static level & draw down etc. by stepdraw down method, collecting water samples & getting tested inapproved laboratory, i/c disinfection of tubewell, all complete, includinghire & labour charges of air compressor, tools & accessories etc.,all as per requirement and direction of Engineer-in-charge. |
| 147 | Providing and fixing suitable size threaded mild steel cap or spotwelded plate to the top of bore well housing/ casing pipe, removableas per requirement, all complete for borewell of: |
| 148 | 200 mm dia |
| 149 | Providing and fixing M.S. clamp of required dia to the top of casing/housing pipe of tubewell as per IS: 2800 (part I), including necessarybolts & nuts of required size complete. |
| 150 | 200 mm clamp |
| 151 | ELECTRICAL WORKS |
| 152 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 153 | Group A |
| 154 | Group B |
| 155 | Group C |
| 156 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loopearthing as required. |
| 157 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loopearthing as required. |
| 158 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 159 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 160 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 161 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 162 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 163 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 164 | Supplying and drawing following sizes of FRLS PVC insulatedcopper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. |
| 165 | 2 x 1.5 sq. mm |
| 166 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessedconduit as required. |
| 167 | 20 mm |
| 168 | 25 mm |
| 169 | 32 mm |
| 170 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 171 | 5/6 A switch |
| 172 | 3 pin 5/6 A socket outlet |
| 173 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 174 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 175 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 176 | 1 or 2 Module (75mmX75mm) |
| 177 | 6 Module (200mmX75mm) |
| 178 | 8 Module (125mmX125mm) |
| 179 | 12 Module (200mmX150mm) |
| 180 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required |
| 181 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required. |
| 182 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 183 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 184 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVCinsulated, copper conductor, single core cable and earthing etc. as required. |
| 185 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable,including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 186 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 187 | Upto 450 mm sweep |
| 188 | Supplying and fixing of following ways surface/ recessmounting, vertical type, 415 V, TPN MCB distribution board ofsheet steel, dust protected, duly powder painted, inclusive of200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 189 | 12 way (4 + 36), Double door |
| 190 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 191 | Single pole |
| 192 | Supplying and fixing single pole blanking plate in the existingMCB DB complete etc. as required. |
| 193 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 194 | 63 A |
| 195 | Earthing with copper earth plate 600 mm X 600 mm X 3 mmthick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 196 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brassnut bolt & spring washer spaced at 50mm) |
| 197 | FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL) |
| 198 | Supplying, installation, testing & commissioning of heat detector operating at 54ºC/57ºC with rate of rise cum fixed temperature (dual thermistor) type with |
| 199 | Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. |
| 200 | Supplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required. 10 Zone panel for fire alarm system 250 Watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all accessories as required - 2 Nos.(one to act as standby) Talk back master station with LED PTT (press to talk) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/communication suitable for 20 Nos.talk back unit -1 set. Annoucement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc. complete as required -1 set. Amplifier change over switch for inter changing amplifier -1 No. Monitor panel for loudspeaker complete with output selector, ON/OFF switch, fuse, visual indications etc. complete as required- 1 No.Gooseneck microphone with stand and ON/OFF switch- 1 No. Main ON/OFF switch, fuse indication lamps, DC and AC voltmeters & ammeters, terminal blocks etc. complete as required -1 set. Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos.12 volt, 60 AH each sealed maintenance free batteries -1 set. |
| 201 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. |
| 202 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 203 | Above 35 sq. mm and upto 95 sq. mm |
| 204 | Supplyof following size Power/Control Copper cables, Solid Copper conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armoured (Galvanised for cables up to 10 x 1.5 sq mm.8 x 2.5 sq mm.2 x 10 sq mm.3 x 10 sq mm.4 x 6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . |
| 205 | 3 & 1/2 Core A2XFY |
| 206 | 35.00 Sq.mm.3 & 1/2 Core U.G.armoured cable |
| 207 | Supplying including installation, commissioning of vermin and dust proof totally enclosed, Phosphatised Powder Painted cubical indoor type floor/wall mounting compartmentalize panel board of size 1.35M X 1.20MX 0.40M made of 16 SWG1.66 m thick C.R. sheet and35mm X 35mm X 5mm size angle having 4 no legs at the bottom. The panel board is to be erected in 1 : 3 : 6 PCC foundation including brick soling / grouting etc. complete neatly Wiring done with provision for one no 250A 4pole MCCB or Switch Fuse Unit as incomer and provision for 6nos DP or TPN out going as specified and directed by the deptt. confirming to IP 43 protection comprising of the following electrical items:1. 20mm X 5mm4 strip copper Bus-Bar 0.6 M length each2. Digital 3 Phase Voltmeter Accuracy class 0.5- 1 no3. Digital 3 Phase Ammeter Accuracy class 0.5- 1 no 4. Pilot Lamp with integral ckt LED 110- 230 V (Red, Yellow,& Blue - 3 no 5. Voltmeter & Ammeter Selector Switch- 2 no6. 2 A Slide fuse unit - 3nos |
| 208 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 209 | 100 A, 16 KA,TPMCCB |
| 210 | 200 A, 25 KA,TPMCCB |
| 211 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 212 | 63 A |
| 213 | Supplyingoffollowing type recessed / surface mounted LED light fixture complete with drivers, earthing point complete as required. (Havells or equivalent) |
| 214 | 1) 12W LED |
| 215 | 2) 15W LED |
| 216 | d) 20W LED bulb |
| 217 | Supplying of followingA.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. |
| 218 | High Speed 225 mm sweep(Havellsmake) |
| 219 | FIRE FIGHTING WORKS |
| 220 | FIRE PUMP WORKS FOR HYDRANTS & SPRINKLER SYSTEM |
| 221 | 1.NOC from fire authority shall be in the scope of Contractor . Only fee paid to the fire authority shall be reimbursed against the submission of the receipt and nothing shall be paid extra. |
| 222 | 2.All the Fire Fighting works shall be done in compliance of Fire Fightinga uthority requirement & relevant codes/standards. |
| 223 | Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) |
| 224 | Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 |
| 225 | Suitable HP squirell cage induction motor TEFC typesuitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-\"F\" insulation, conforming to IS-325. |
| 226 | M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. |
| 227 | Suitable cement concrete foundation duly plastered and with anti vibration pads. |
| 228 | 900 lpm at 35 m Head |
| 229 | PIPING & ACCESSORIES |
| 230 | Providing laying, testing & commissioning of \"C\" class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. |
| 231 | 150 mm. Dia |
| 232 | Providing, laying, testing & commissioning of \"B\" class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : |
| 233 | 80 mm dia. |
| 234 | Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : |
| 235 | Single headed Stainless steel |
| 236 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts,washers, gaskets conforming to IS 13095 of following sizes as required : |
| 237 | 150 mm dia |
| 238 | Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. |
| 239 | 150 mm dia |
| 240 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : |
| 241 | Gun Metal |
| 242 | Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : |
| 243 | 4 way - 150 mm dia M.S. Pipe |
AI Tender Summary
Tender Timeline
Sep 13, 2023
11:30 IST
Tender Published
Tender notice published.
CompletedOct 03, 2023
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedOct 03, 2023
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender