Tender For Providing Internal Electrification Of Newly Constructed Tribal India Show Room Cum Sales Counter At Kmr Tribal Rest House Premises At Melarmath Agartala, agartala-Tripura

Public Works Department-PWD has published Tender For Providing Internal Electrification Of Newly Constructed Tribal India Show Room Cum Sales Counter At Kmr Tribal Rest House Premises At Melarmath Agartala. Submission Date for this Tender is 25-09-2023. Electrification Work Tenders in agartala Tripura. Bidders can get complete Tender details and download the document.




Tender Notice

39621454
Tender For Providing Internal Electrification Of Newly Constructed Tribal India Show Room Cum Sales Counter At Kmr Tribal Rest House Premises At Melarmath Agartala
Open Tender
Indian
Tripura
agartala
25-09-2023

Tender Details

Providing Internal Electrification Of Newly Constructed Tribal India Show Room Cum Sales Counter At Kmr Tribal Rest House Premises At Melarmath Agartala

Key Value

Document Fees
INR 1000 /-
EMD
INR 2424.0 /-
Tender Value
INR 1.21 Lakhs /-

BOQ Items

Name of Work: Providing internal electrification of newly constructed Tribal India Show Room-Cum-Sales Counter at KMR Tribal Rest House premises at Melarmath, Agartala.
Sl. No. Item Description
1Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with 6/10 amps modular type switch, cover plate, surface modular switch board including connection etc as required:-
2Short Point :-
3Medium Point :-
4Long Point :-
5Providing and fixing of 3 pin 6/10 amps plug point withmodulartype 6/10ampsswitch andsocketincludingconnectionwith 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on surface modularswitch board, earthing the 3rd pin etc. as required:-
6Providing and fixing of 3/6 pin 16/20 amps plug point withmodulartype 16/20ampsswitch andsocketincludingconnectionwith 2x2.5 sq. mm PVC insulated Copper conductor cable(FR) on surface modular switch board, earthing the 3rd pin etc. as required:-
7Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required.
82 X 1.5 sq mm
92 X 2.5 sq mm
102 X 4 sq mm
112 X 6 sq mm
12Wiring for Circuit/Sub-main with the following sizes PVC insulated Copper conductor cable (FR) in PVC conduit including connection etc. as required
132 X 1.5 sq mm
142 X 2.5 sq mm
15Wiring for Circuit/Sub-main wiring with the following sizes of PVC insulated copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required:-
161 X 1.5 sq mm
17Supplying and fixing of the following sizes PVC conduit (medium gauge) on surface with all accessories etc. as required.
1819/20 mm dia
1925 mmdia
20Supplying and fixing of the following electrical accessories including necessary connection etc. as required.
2132 amps DP kit kat switch:-
22Supplying and fixing of the following modular accessories including necessary connection etc. as required.
234 step fan regulator (1M):-
24Blank plate (1M):-
25Supplying & fixing of 900 mm sweep white color AC ceilingfan capacitor typedouble ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR) :-
26Supplying & fixing of 1200 mm sweep white color AC ceilingfan capacitor typedouble ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR)(ISI marked, BEE 1star/minimum service value 4.0 m3/min/W) : -
27Supplying & installation of 225/230 mm sweep metalic body exhaust fan including connection etc as required:-
28Supplying & installation of shutter for 225/230/300 mm sweep metalic body exhaust fan in the existing hole as required:-
29Supplying and fixing of 20 mm dia extra down rod (GI Pipe Medium Guage) with necessary hole for installation of ceiling fan as required.
30Making different sizes of hole in the wall for fixing of exhaust fan including finishing the same with cement plastering and painting etc as required:
31Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc.as required (with 50000 burning hours and minimum lumen output of 100 lm/watt):-
32Surface mounted box type batten suitable for single 18/20 watt integrated LED tube lamp (without lamp):-
33Surface mounted round/Square shaped 6/7 watt LED downlight with integral driver and high quality polycarbonate diffuser:-
34Surface mounted round/Square shaped 12 watt LED downlight with integral driver and high quality polycarbonate diffuser:-
35Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt):-
3640 watt LED post top light fixture with integral driver and high quality polycarbonate diffuser (IP 65):-
37Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:-
3818/20 watt LED tube with integral driver and polycarbonate diffuser (50000 burning hours and minimum lumen output of 100lm/watt):-
39Supplying and installation of Switch disconnector fuse unit (main switch) of the following ratings with all accessories including necessary connection etc. as required:-
4032 amps 240 volts DP main switch (rewireable):-
41Supplying and fixing of powder coated sheet steel enclosure on surface/ recess, suitable for 240/415 volts MCB/Isolator/RCCB (SP/ SPN/ DP/ TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connectionas required.
42(2+6) / 8way SPN MCB DB (double door):-
43Supplying & fixing of following ratings MCBB/C curve having breaking capacity10 KA in the existing MCB DB including connectionas required
446 to 32 amps SP MCB
45Supplying & fixing of following ratings isolator in the existing MCB DB including connection etc as required:-
4640 amps DP isolator:-
47Supplying and laying of the following sizes XLPE insulated PVC sheathed aluminium conductor armoured cable with necessary connection etc as required
483 core 4 Sq mm
49Supplying & fixing of G.I. pipe (medium gauge) bracket fabricated at suitable angle for fixing of outdoor light on wall/ RCC base with necessary MS clamp, nut, bolt etc as required:-
5040 mm dia
51Supplying & fixing of 40 mm dia G.I pipe (medium gauge) cross bar for fixing of ceiling fan/luminaries i/c painting etc as required.
52Supplying & fixing of 40mmx6mm MS clamp for installation of ceiling fan/luminaries on cross bar including necessary accessories etc as required:-
53Supplying of ‘U’ clamp made with 40mm x 6 mm MS flat and fixing with necessary fasten nuts including painting etc as required.
54Supplying of 25 cm long ‘L’ hook made with 40mm x 6mm MS flat and fixing with necessary fasten nuts including finishing, painting etc as required.
55Supplying &fixing of 12mm thick marine plywood conforming to IS:710 with necessary painting etc as required:-
56Drawing of armoured/un-armoured cable with proper saddling etc as required:-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail