| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable inPVC casing caping with modular switch, modular plates,suitable size modular surface box of specified Category and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc. as required. |
| 2 | (c) Group C-- with Cat A Modular Accessories |
| 3 | \"Supplying and fixing3 pin 5/6 Amodular socket outlet and5/ 6 Amodular switchonboard the modular surface/recessed PVC/GImodular box by suitably increasing its modular capacity, modular plate and cover including connection painting etc. as required. |
| 4 | (b) Cat B |
| 5 | Supplying and fixing suitable size modular PVC box with modular plate and coverin front on surface or in recess including providing and fixing 3 pin 5/6 Amodular socket outlet and5/ 6 Amodular switch connection painting etc. as required. |
| 6 | \"(b) Cat B |
| 7 | Supplying and fixing suitable size modular PVC box with modular plate and coverin front on surface or in recess including providing and fixing 1 no 6 pin 15/16 Amodular socket outlet and 1 nos 15/ 16 Amodular switch connection painting etc. as required.( For workstations) |
| 8 | \"(b) Cat B |
| 9 | Wiring for5A /15A plug with 2 x4 sq.mm FR PVC insulated copper conductor single core cable in PVC casing capping alongwith 1 No 4 sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required. |
| 10 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor single core cable in the independentPVC casing capping of appropriate size as required. |
| 11 | (a) 2 x 1.5 sq.mm + 1 x 1.5 sq.mm earthwire (20mm casing ) |
| 12 | (a) 2 x 2.5 sq.mm + 1 x 1.5 sq.mm earthwire (20mm casing ) |
| 13 | (d) 2 x 6 sq.mm + 1 x 6 sq.mm earthwire (25mm casing ) |
| 14 | (j) 4 x 6 sq.mm + 2 x 6 sq.mm earthwire (32mm casing ) |
| 15 | Supplying and fixing of following sizes ofrigid PVC conduit alongwith accessories in surface(medium)/recess(heavy) includingcutting the wall and making good the same in case of recessed conduit as required. |
| 16 | \"(a) 20 mm |
| 17 | Supplying and fixing stepped type electronic fan regulator on the existing modularplate switch box including connections but excluding modular plate etc. as required |
| 18 | (b) Cat B |
| 19 | \"Supplying and fixing call bell/ buzzer suitable forsingle phase 230 V complete as required. |
| 20 | \"Supplying and fixing brass batten/ angle holderincluding connections etc as required. |
| 21 | LED Lamp |
| 22 | Supply and erecting meter box suitable for three phase energy meter and incoming SP/DP MCB, fabricated out of 16 SWG sheet steel, powder coated, complete as required and conforming to the requirements of Goa Electricity Deaprtment. |
| 23 | \"Supply, installation, testing and commissioning of electronic type three phase energy meter (KWh), 4 wire, ISI marked, in polycarbonate or sgheet steel body ( base mounting type) with counter display/LCD display, with ELT, in Class 1.0, 50 Hz, 240 V. AC duly tested by MRT along with Test Certificates, complete as required of following capacity of make L & T only. |
| 24 | \"(b) 10 to 40 A |
| 25 | Supplying and fixing 6 A to 32 A,C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required. |
| 26 | \"(f) SP, Cat B |
| 27 | \"(i) TP, Cat B |
| 28 | Installation, earthing, testing and commissioning of pre-wired fluorescent fitting/ compact fluorescent fittings of all types complete with all accessories and tube etc. directly on ceiling / wall including connections with 1.5 sq .mm FRLS PVC insulated copper conductor single core cable and earthing etc. as required. |
| 29 | \"Installation,earthing, testing and commissioning of ceiling fan including wiring the down rodof standard length ( upto 30 cm) with 1.5 sq .mm FRFRLS PVC insulated copper conductor single core cable etc. as required. |
| 30 | Carriage of ceiling fan and regulator/ exhaust fan from store to site as required. |
| 31 | Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required |
| 32 | \"Supplying and fixing following way SPN sheet steel MCB distribution board 240 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required ( but without MCB/RCCB/Isolator) |
| 33 | \"(o) 12 way double door Cat B |
| 34 | Supplying and fixing following way TPN sheet steel, double door, Horizontal type MCB distribution board 415 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required ( but without MCB/RCCB/Isolator) |
| 35 | \"(f) 4 way (4+12), double door, Horizontal type Cat B |
| 36 | Supplying and fixing following rating double pole 240 V isolatorin the existing MCB DB complete with connections testing and commissioning etc as required |
| 37 | (f) 40 A, Cat B |
| 38 | \"Supplying and fixing following rating three pole 415 V isolatorin the existing MCB DB complete with connections testing and commissioning etc as required |
| 39 | \"(g) 63 A, Cat B |
| 40 | Earthing with GI earth pipe 2 mts long 40 mm dia medium class with ISI mark,of approved brands, including accessories and providing masonry enclosure with CI/RCC coverhaving locking /lifting arrangement and watering pipe etc.withcharcoal or coke and salt) as required as per the Earthing Drawing provided by the Engineer-Incharge.The scope of work includes the following: a) Excavation ofpit of size 1.0x1.0x 2.0 mtrs(min) and disposal of excavated soil. b) Class B GI pipe, 40mm diameter as per specifications.c)Charcoal/salt as per specs ( paid seperately). |
| 41 | d) Refilling the pit of size 1.0x1.0x 2.0 mtrs(min) with soft black soil of minimum resistivity i/c transportation. e)Masonary chamber with proper foundation, cover plate and locking arrangement. f) Testing of earth value with earth megger and certifications of its value. Aluminium tag with embossed earthing value to be attached to the pipe. g)watering arrangement(plumbing will be paid seperately).(b) In rocky strata |
| 42 | Providing and fixing 6 SWG dia GI wireon surface or in recess for loop arthing along with existing surface/ recessed conduit/ submain wiring/ cable as required |
| 43 | Supply and erecting of 48 inch ( 1200mm sweep) ceiling fan, double ball bearing type, , complete with all accessories. |
| 44 | \"(a) Cat A |
| 45 | Supply of 4 feet 20 W double box/batten industrial type LED luminaire with CRCA body pre coated in white and pre wired for LED type complet with all accessories of make Crompton , model no IGP 132LT8-16 or Havells bearing Cat No. LHFYBYG2INIW020/ Bajaj Bearing Cat No.BLRB-DB 218/Wipro bearing Cat No WIO 922208including 2 Nos of4 feet 20 W LED tube of make crompton bearing Cat No. LTT8-20/Bajaj bearing Cat No.BLRB 18W CWc /Havells bearing Cat No.LHLDCLXUL8X020 or Wipro bearing Cat No. LL13-181-650 as required.( Equivalent to be approved by Engineer in charge). The LED tube should have a warranty of two years from the date of commissioning. |
| 46 | Supply, drawing and fixin of twin core 10 sq. mm weather proof wire along withGI wire of 8 SWG for service connection including termination of approved make withISI mark. |
| 47 | Supply of 4 feet 20 W single box/batten industrial type LED luminaire with CRCA body pre coated in white and pre wired for LED type complet with all accessories of make Crompton , model no IGP 131LT8-16 or Havells bearing Cat No. LHFYBYPNIA1W022/ Bajaj Bearing Cat No.BLRB-DB 118/Wipro bearing Cat No WIO 921208 or any approved brand including 1 No ofof4 feet 20 W LED tube of make crompton bearing Cat No. LTT8-20/Bajaj bearing Cat No.BLRB 18W CWc /Havells bearing Cat No.LHLDCLXUL8X020 or Wipro bearing Cat No. LL13-181-650 as required.( Equivalent to be approved by Engineer in charge). The LED tube should have a warranty of two years from the date of commissioning. |
| 48 | Dismantling of light point, fan points, submain wiring and all electrical accessories includingM.S. main board, D B, main switch board, light points, PVC pipes etc and making good the surface,plastering and painting the patch work to maintain the shade etc, complete as required and as directed by Engineer in Charge. |