Irrigation And Public Health Department has published Source Strengthening And Rehabilitation Of Various Water Supply Schemes Under Jal Shakti Sub Division Sandhole In Tehsil Dharampur Distt. Mandi Hp. (Under Jjm) (Sh:- C/O Intake Chamber, Repair Of Pump House, Protection Of Sources Of Various Schemes By Pro. Submission Date for this Tender is 20-09-2023. Pumping Machiney Tenders in Mandi Himachal Pradesh. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Excavation in foundation, trenches etc. in all kinds of soil such as pick work, jumper work, blasting work in soft / hard rock, chiselling in soft / hard including wedging out of a rock where blasting is prohibited and stacking the excavated earth up to all lifts, stacking the excavated soil up to all lead clear from the edge of excavation and then returniing the stacked soil in 15 centimeters layers when required in to plinths, sides of foundation etc. consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated earth as directed within all leads & lifts as perentire satisfaction of Engineer- in- charge. |
2 | Providing and laying cement concrete 1:4:8 (1 cement : 4 sand : 8 graded stone aggregate 40 mm nominal size ) and curing complete excluding cost of form work in foundation and plinth within all leads and lifts as per direction and to the entire satisfaction of the Engineer in Charge. |
3 | Providing and laying cement concrete 1:3:6 (1 cement: 3 sand: 6 graded crushed stone agg. 40mm nominal size) and curing complete excluding cost of form work in:- Foundation and plinth upto all leads and lifts as per direction and to the entire satisfaction of Engineer-in-charge. |
4 | Providing & Laying cement concrete work Grade M30 (Design Mix) but not leaner than 1 : 1.5 : 3 (1 cement : 1.5 sand : 3 graded stone aggregate 20 mm nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work in:- |
5 | Lintels,beams, girders, bressumers and cantilevers upto floor two level within all lead and lifts as per direction and to the entire satisfaction of Engineer-in-Charge. |
6 | Suspended floors, roofs, landing and shelves and their support, balconies, beams, girders, bressumers and cantilever upto all floor level within all leads and lifts as per direction and to the entire satisfaction of the Engineer in Charge. |
7 | Providing form work with steel plates 3.15 mm thick welded with angle iron in frame 30x30x5mm so as to give a fair finish including centring, shuttering , strutting and propping etc. with wooden battens and ballies, height of propping and centring below supporting floor to ceiling not exceeding 4 mtrs. and removal of the same for insitu- reinforcement concrete and plain concrete work in:- |
8 | Flat surfaces such as soffits of suspended floors, roofs, landings and the like, Floors etc. up to any thicknesscomplete within all leads and lifts as per direction and to the entire satisfaction of Engineer-in-Charge. |
9 | Beam, cantilever, girders and lintels, Sides and soffits of beam, beam haunching, cantilever, bressumers and lintels not exceeding 1 mtr. In depth in all heights from floor complete within all leads and lifts as per direction and to the entire satisfaction of Engineer-in-Charge. |
10 | Edges of slabs and breaks in floors and walls under 20cm wide in all leads and lifts as per direction and to the entire satisfaction of Engineer-in-Charge. |
11 | Providing Tor steel reinforcement for RCC work including bending binding and placing in position complete upto all floor level within all leads and lifts as per direction and to the entire satisfaction of the Engineer in Charge. |
12 | Wire crates G.I. wire filled with boulders with square cut faces against the wire (wire crates to be measured andpaid for seperately) in all leads and lifts as perdirection and to the entire satisfaction of Engineer -in-Charge. |
13 | Wire crates made of G.I wire filled with boulders with square cut faces against the wire (boulder fillingto be measured and paid for seperately) G.I. wire 5mm thick corresponding to SWG-6,15cmx15cmmesh in all lead and lift as per direction and to the entire satisfactionof Engineer-in-Charge. |
14 | Demolition above G.L. upto floor two level including disposal of unserviceable materials within 20 metres lead and including cutting the necessary reinforcement and seperating out from RCC/RB works as per direction and to the entire satisfaction of Engineer-in-Charge. |
15 | Providing and laying no fine cement concrete 1:4 (1 cement: 4graded stone aggregate 20mm nominal size) and curing complete excluding cost of form work in. Cement Mortar 1:4 |
16 | Brick work using common burunt clay building bricks in super structure above plinth level up to floor two level in cement mortor 1:4 (1 cement : 4 sand) (2nd class brick) within all leads and lifts as per direction and to the entire satisfaction of the Engineer in Charge. |
17 | Providing and fixing steel glazed doors, windows and ventilators of standered rolled steel sections, joints mitred and welded with 16x3.15mm lugs 10cm long embedded in cement concrete blocks 15x10x10cm 1:3:6 (1 cement: 3 sand: 6 graded stone aggregate 20mm nominal size) with wooden plugs and screws or rawl plugs and screws or with bolt and nut as required, including fixing of glass panes with glazing clips and special metals ash putty of approved make complete as per architectural drawing and direction of Engineer in-charge |
18 | Providing wood work in frames of door, window, clerestory window and other frames wrought, framed & fixed in position as per direction and to the entire satisfaction of Engineer-in-charge upto all lead and lifts. (2nd class deodar wood) |
19 | Providing and Fixing panneled glazed or panelled and glazed shutters for doors, windows and clerestory windows,including black enamelled iron butt hinges with necessary screws. 40 mm thick. (2nd class deodar wood) within all leads and lifts as per direction and to the entire satisfaction of the Engineer in Charge. |
20 | 15mm thick cement plaster in single coat on rough side of brick/concrete/stone walls for interior plastering upto floor two level includong arises, internal round angles, chamfers and/or rounded angles not exceeding 80mm in girth and finished even and smooth (Cement mortar 1:4) |
21 | 20mm thick cement plaster in single coat on rough side of brick/concrete/stone walls for interior plastering upto floor two level includong arises, internal round angles, chamfers and/or rounded angles not exceeding 80mm in girth and finished even and smooth (Cement mortar 1:3) |
22 | 6 mm thick cement plaster to ceiling In cement mortar 1:3 (1 cement: 3 sand) |
23 | Providing and placing of horizontal layer filtering media duly graded screened washed and cleaned as specified by the Engineer-in-charge. |
24 | (a) Broken stone 75 to 50mm |
25 | ( c) Bajri screened, washed and graderd from 6mm to 20mm |
26 | (b) Fine sand screened, cleaned, washed and graded effective size20 to 40mm with uniformity co-efficient 2 to 3. |
27 | Cement concrets flooring 1:2:4 (1 cement :2 sand :4 graded stone aggregate 20mm nominal size) laid in one layer finished with a floating coat of neat cement (40 mmthick) as per direction and to the entire satisfaciton ofEngineer-in-charge upto all lead and lift. |
28 | Kota stone slab flooring 20 mm (average) thick base of cement mortor 1:4 (1 cement :4 sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab. including rubbing and polishing complete 40 mm Thick as per direction and to the entire satisfaction of Engineer-in-Charge. |
29 | Providing and fixing anodized aluminium sliding door bolt anodized colour and shade with bolts and nuts screws etc. complete. as per the direction and to the entire satisfaction of Engineer-in-charge. |
30 | 250 x 16 mm |
31 | Providing and fixing aluminium tower bolt (barrel type) anodized transparent or dyed as per the direction and to the entire satisfaction of Engineer-in-charge . |
32 | 200 x10 mm |
33 | Providing and fixing aluminium handles anodized transparent or dyed to required colour shade with necessary screws etc. Complete as per the direction and to the entire satisfaction of Engineer-in-charge. |
34 | 100 mm |
35 | Providing 40x3 mm iron hold fast 40 cm long including Fixing to frame with 10 cm da bolts nuts and wooden pluges and embencing in C.C. block 30x10x15 cm 1:3:6 ( 1 cement:3 sand: 6 gradedstoneaggregate 20 mmnominal size) within all leads and lifts as per direction and to the entire satisfaction of the Engineer in Charge. |
36 | Squared rubble masonry coursed with hard stone of approved quality in foundation and plinth including raking out joints in foundation & plinth in cement mortar 1:4 as per direction and to the entire satisfaction of Engineer-in-charge |
37 | Random rubble masonry/Polygonal rubble masornry ( uncoursed/ brought to courses) with hard stone of approved quality in foundation and plinth I/c levelling up with cement conrete 1:6:12 (1cement:6 sand :12 graded stone aggregate 20 mm nominal size ) at plinth level in cement motar 1:6 ( 1cement:6 sand)includingcuring complete. As per direction and to the antire satiafaction of the Engineer-in- charge in all lead and lifts. |
38 | White washing with lime on undecorated wall surface two coats to give an even shade I/c throughly brooming the surface to remove all dirt, dust, mortar, dust and other foreign matter as per direction and to the entire satisfaction of Engineer-in-charge. |
39 | Applying priming coat over new wood and wood based surfaces after and inciuding preparing the suface be thoroughly cleaning oil grease dirt and othr foreign sand papering and knotting Readymixed paint brushing wood primer pink complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge. |
40 | Painting two coats (excluding priming coat) on new wood and wood based surfaces with enamel paintto give an even shade including cleaningthe surface of dirt, dust and other foreign matters sand papering and stopping with enamel paint other than white complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge. |
41 | Applying Birla white wall care putty over plaster surface after thoroughly brushing the surface free from mortar drops, dust, loose materials and other foreign matters sand papered smooth to give final matter finish to the surface complete. |
42 | Painting two coats (excluding priming coat) on concrete/masonry/asbestos cement/plastered surfaces under coat with readymixed paint brushing for use on floors to give an even shade including cleaning the surface of all dirt, dust and other foreign matter and sand papering as required with:Paint other then white |
43 | Providing and fixing PVC water storage tank of ISI : 12701 marked, G.I. inlet and outletconnection, 15mm nominal bore ball valve and mosquito proof PVC cover with lockingarrangement including hoisting up to all heights above ground level :-1000 litres net capacity tank Syntax make |
44 | Providing and fixing vitreous china wash down water closet (European type W.C. Pan) with integral "P" or "S" trap including jointing the trap with soil pipe in cement mortar 1:1 (1 cement : 1 sand) (seat and cover to be measured and paid for separately) |
45 | Providing and fixing vitrous china wash basin with single hole for pillar tap with C.I. or M.S. brackets painted white including cutting holes and making good the same but excluding fittings550mm X 400 mm |
46 | Providing & fixing on wall face PVC (D-Plast) rain water pipes of working pressure not less than 4.5 kg/sqm including filling the joints with approved adhesive compete.75 mm dia pipes |
47 | Providing and Fixing to wall, ceilling and floor galvanised mild steel tube (MC), fitting and clamps includingmaking good the wall, ceiling and flooring 15mm |
48 | Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. Group-C |
49 | Supplyingand fixingoffollowingway, singlepoleandneutral sheetsteel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:- |
50 | Providing, Installation, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. Ceiling Fan 1400 mm sweep, Category-A |
51 | Providing and fixing LED Lamp 15 W of Havells/Usha Make. |
52 | Laying, jointing and testing in trenches (to level or grade) of following dia Heavy Class GMS pipes plain ended jointed with 1% flanged & remaining 99% butt weld joints with of below diametreconforming to IS 1239-1990 (Part - I ) with latest upto date amendments of grade and wall thickness as specified below, suitable to withstand required hydraulic test pressure in randum length 4m-6m with plain ends and jointed with butt welding with electrodes as per IS 814-1991. The welding of joint to be done to make the joints leak proof (Earth work, flanged joints & butt welding joints to be mearsured and paid separately) and toentire satisfaction of the Engineer-in-Charge.The laying of pipes conform to IS 5822-1994 and as per CPHEEO manual and will include all operations such as cutting, welding and jointing including flushing, cleaning and hydraulic testing complete in all respect. (L.R.) |
53 | 100mm dia Heavy Class, wall thickness = 5.4mm |
54 | Providing and welding M.S. flanges at suitable point, conforming to following tables as per IS 6392-1971 (Latest with up to date amendments)with plain end GMS pipe in three layers on both faces to make the joint leak proof (The cost oflaying of GMS pipes to be measured and paid for separtely). The welding of flanges should conform to IS 816-1969 with electrodes as per IS: 814-1991 and required number of nuts and bolts conforming to IS 1364, the thicthness of gasket not less than 3.00 mm conforming to IS 2712-1998. The work shall be done as per entire satisfaction of engineer in charge with in all leads and lifts. |
55 | M.S. Flange joint 100 mm dia, Flange Table-5 |
56 | Providing circumferencial Butt welded joints by electrical arc welding to following diaGMS Pipes welded in requisite number of weld runs including thread cutting so as to achieve the minimum effective throat thickness of weld conforming to IS 816-1969 specifications, by using welding electrodes of 2.5mm to 6.3mm of Advani Oerlikon (Adore)- CITOJET/ESAB make, conforming to IS 814-1991, at site of work complete in all respects, including manual/mechanical handling of pipes in all leads and lifts to the entire satisfaction of Engineer-in-Charge. |
57 | 100 mm dia. |
58 | Providing and fixing double flanged cast steel Sluice valve of 100 mm dia of Kirloskar / Leader/KSB or JSV approved make conforming to BS: 1414/API-600 Class ASA-150 including M.S. flangesas per IS 6392-1971 including welding of flanges and capable of with standing of normal seat pressure with upto date amendments including carriage within all leads and liftsas per direction and to the entiresatisfaction of Engineer-in-Charge. |
59 | 100mm dia with FT-5 |
60 | Pumping Machinery submersible (Percolation Well) :- Supply & errection ofsubmersible pump set of KSB/Calama/Johnston/SU/Kirloskar or JSV approved make conforming to BIS:8034-1976 or latest suitable for lifting Water (latest with upto date ammendments) fitted with bronze impellers/ suitable alloye. The pump should be fitted with free flow impellers of bronze/suitable alloys directly coupled to squirrell case electric induction motor of same make as (manufacturer standard) conforming to BIS: 9283-1979 (latest with upto date ammendments ) and totally water proof for submersible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearing & provided with stainless steel thrust bearing plate to with stand vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard errection clamps, manufacturer cable clips & depth gauge etc. The pump shall be suitable for operation on data given below:- |
61 | SITE CONDITIONS:- Total Head 28.82mtrs Discharge required 4.98LPS each set. No. of Pump required.2Nos1set act as stand bye. Location of the site of installationof machinery:- The site is located at a distance ofKm from The Altitude of :- The Altitude of place is 649.50 mtrs above MSL Type of Current:-AC three phase supply with RateVoltage:-415+/-10% Type of water and its Charactristics of water a) Ambient b) Turbidity NTU NTU c) Hardness260 Mg/Ltrs -- d) PH Value5.00 HP-- e)Total Solid Mg/Lts)PH Value -- f) Other -- Length of R/main 500 mtrs Dia of Rising main 100 mm dia. No of working hours.16 Hours. Limit of Pump (-) 15% (+) 10% of R. M.P. of Pumping2900 RPM (or to be specified by the tenderer) Test run 16 Hours continueously for 7 days. |
62 | Supply of Direct on line (D.O.L.) Starter of reputed make i.e L&T/Siemen conforming to BIS 8544 -( Part - I) 1987 latest with upto date amendments for squirrel cage induction motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release and gas-pots, time legs, under voltage release & initial oil filingsuitable for 5.0 HP motor. |
63 | Supply of MS. Angle iron steel sheet 16 SWG fabricated floor mounting closed (Almirah type) switch board comprising and capable of mounting the following accessories and with all internal electric connections, duly painted. The drawing of panel boardshall be subject to approval of Engineer-in-Charge. |
64 | Ammeter AC supply, 100 mm square type auto electric of AE/ L&T Rishab make of 0-63 Amp. capacity for above motor with selector switches conforming to IS-1248 (Part - II)-1983 latest with upto date amendments. |
65 | Voltmeter AC supply, 100 mm square type auto electric AE/ L&T Rishab make of0 - 500 Voltsrange for above motor with selector switches conforming toIS-1248 (Part - II)-1983 latest with upto date amendments. |
66 | ICTP switches 32 Amp. with HRC fuses of Havells/L&T/standard /crompton make for required motor of 5.0 HPcapacity and conforming to IS: 4064 (part - II)1978 latest with upto date amendments. |
67 | Bus bar chamber having 3 copper bars of suitable rating for full length of 3 phases and one bar of half the rating of full length for neutralconforming to IS:8084 –1976 and 11354-1985 read with 5578-1985 all latest with upto date amendments of suitable rating. |
68 | MCB/MCCB of 32 Amp suitable for motor of 5.0 HP capacity of Havells /standard /MDS/ Kilburn make to feed motors offered by the tenderer conforming to IS: 2516 (Part - II ) 1985 latest with upto dateamendments with neutral linked under voltage release. |
69 | 3 phase indicator lamps complete with toggle switches for individual motors conforming ti IS 3452 part I & II latest with up to date amendments of 15 watts. |
70 | 50 mm dial Hour run meter of CEE / NEE make of suitable range as per relevant IS specifications. |
71 | Supply of Kirloskar/Leader or JSV approved make cast iron (class PN 1.00 ) double flanged sluice valve of 80 mm dia. and capable of with standing nominal seat pressure of 10.20 kg/cm2 as per IS :14846-2000. |
72 | Supply of Kirloskar/Leader or JSV approved make cast iron (class PN-1.00) double flanged (swing check type) reflux valve having bye pass arrangement and 80 mm dia. and capable of with standing nominal seat pressure of 10.20 Kg/Cm 2 as per IS: 5312 (Part-I) 2004 |
73 | Providing and laying suitable size copper PVC insulated armoured power 3.5 core cable conforming to BIS 1554 (part-I) –1988 of latest with upto date amendments L&T/Finolex make form meter of HPSEB- to CB and form CB to Bus bar switch and starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipe solder, nuts and bolts, cable glands, etc. laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer. Supply side 2.5 sqmm or of Suitable sizes. |
74 | Supply of Kirloskar/Leaderor JSV approved make 100 mm dia. cast Iron class PN-1.00 double flanged (swing check type) reflux valve having bye pass arrangement and 100 mm dia. of rising i.e. 100 mm for with standing nominal seat pressure of 10.20 Kg/Cm 2 as per IS: 5312 (Part-I) 2004 |
75 | Supply of PVC joint less flat water proof cable as per IS: 694-1990 latest with upto date amendments suitable for the pump sets offered from CB to motor including all other electrical equipment / accessories such as thimbles, flexible pipes solder, nuts and bolts, cable glands etc laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities & in case of non acceptance by HPSEB authorities it shall have to be replaced bytender. |
76 | Providing and laying double loop earthing with G.I. wire & G.I plate complete with material such as charcoal, common salt, GI. Pipes, thimbles, nuts and bolts, digging of pits, GI. Wiring and aluminum strips of requiredcapacity conforming to BIS: 3043-1987 latest with upto date amendments for above motors and otherelectrical equipment’s. |
77 | Supply of standard make circular dial pressure gauge 0-16 kg/cm2 range of feibig make with all accessories such s stop cock, copper tubing etc, conforming to IS: 3624-1987 latest with upto date amendments. |
78 | Providing and laying delivery pipe 100 mm dia. and common header 125 mm dia GMS pipe Medium classas per IS:1239-2004 (Part-I) jointed with MS flanges of table -17 as per IS: 6392-1971 (uptoa length of 10 mtrs ) including rappers, flanges, rubber gaskets, nuts and bolts and specials upto 5 mtrs away from the outer wall of pump houses/well as per layout drawings approved by Engineer-in-Charge. |
79 | Supply of floor/wall mounted power factor shunt capacitor conforming to BIS: 2834-1986 latest with upto date amendments L&T make to raise the prevailing power factorat site to 0.95 for direct connection to induction motor individually of suitable rating each including cable of L&T/Finolex make formbus bar chambertocapacitor andalso including L&T/LK/Kilburn make ICTP switches conforming to IS – 4064 (Part - II) 1978 or latest with HRC fuses (range to be specified by the tendrerer). |
80 | Supply of suitable cable for water level guard |
81 | Supply of supporting clamps. |
82 | Supply of cable clips of required size. |
83 | Erection of all equipment from Sr. No. 46 to 58 including cost of tees, bends, tapers and any other fittings required as per site conditions and as per direction of Engineer-in-charge. |
84 | Pumping Machinery (LWSS Lasrana) :- Supply & errection ofsubmersible pump set of KSB/Calama/Johnston/SU/Kirloskar or JSV approved make conforming to BIS:8034-1976 or latest suitable for lifting Water (latest with upto date ammendments) fitted with bronze impellers/ suitable alloye. The pump should be fitted with free flow impellers of bronze/suitable alloys directly coupled to squirrell case electric induction motor of same make as (manufacturer standard) conforming to BIS: 9283-1979 (latest with upto date ammendments ) and totally water proof for submersible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearing & provided with stainless steel thrust bearing plate to with stand vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard errection clamps, manufacturer cable clips & depth gauge etc. The pump shall be suitable for operation on data given below:- |
85 | SITE CONDITIONS:- Total Head18.00mtrs Discharge required 5.47LPS each set. No. of Pump required.2Nos1set act as stand bye. Location of the site of installation of machinery:- The site is located at a distance ofKm from The Altitude of :- The Altitude of place is 575 mtrs above MSL Type of Current:-AC three phase supply with RateVoltage:-415+/-10% Type of water and its Charactristics of water a) Ambient b) Turbidity NTU NTU c) Hardness260 Mg/Ltrs -- d) PH Value5.00 HP-- e)Total Solid Mg/Lts)PH Value -- f) Other -- Length of R/main 300 mtrs Dia of Rising main 100 mm dia. No of working hours.16 Hours. Limit of Pump (-) 15% (+) 10% of R. M.P. of Pumping2900 RPM (or to be specified by the tenderer) Test run 16 Hours continueously for 7 days. |
86 | Supply of Direct on line (D.O.L.) Starter of reputed make i.e L&T/Siemen conforming to BIS 8544 -( Part - I) 1987 latest with upto date amendments for squirrel cage induction motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release and gas-pots, time legs, under voltage release & initial oil filingsuitable for 5.0 HP motor. |
87 | Supply of MS. Angle iron steel sheet 16 SWG fabricated floor mounting closed (Almirah type) switch board comprising and capable of mounting the following accessories and with all internal electric connections, duly painted. The drawing of panel boardshall be subject to approval of Engineer-in-Charge. |
88 | Ammeter AC supply, 100 mm square type auto electric of AE/ L&T Rishab make of 0-63 Amp. capacity for above motor with selector switches conforming to IS-1248 (Part - II)-1983 latest with upto date amendments. |
89 | Voltmeter AC supply, 100 mm square type auto electric AE/ L&T Rishab make of0 - 500 Voltsrange for above motor with selector switches conforming toIS-1248 (Part - II)-1983 latest with upto date amendments. |
90 | ICTP switches 32 Amp. with HRC fuses of Havells/L&T/standard /crompton make for required motor of 5.0 HPcapacity and conforming to IS: 4064 (part - II)1978 latest with upto date amendments. |
91 | Bus bar chamber having 3 copper bars of suitable rating for full length of 3 phases and one bar of half the rating of full length for neutralconforming to IS:8084 –1976 and 11354-1985 read with 5578-1985 all latest with upto date amendments of suitable rating. |
92 | MCB/MCCB of 32 Amp suitable for motor of 5.0 HP capacity of Havells /standard /MDS/ Kilburn make to feed motors offered by the tenderer conforming to IS: 2516 (Part - II ) 1985 latest with upto dateamendments with neutral linked under voltage release. |
93 | 3 phase indicator lamps complete with toggle switches for individual motors conforming ti IS 3452 part I & II latest with up to date amendments of 15 watts. |
94 | 50 mm dial Hour run meter of CEE / NEE make of suitable range as per relevant IS specifications. |
95 | Supply of Kirloskar/Leader or JSV approved make cast iron (class PN 1.00 ) double flanged sluice valve of 80 mm dia. and capable of with standing nominal seat pressure of 10.20 kg/cm2 as per IS :14846-2000. |
96 | Supply of Kirloskar/Leader or JSV approved make cast iron (class PN-1.00) double flanged (swing check type) reflux valve having bye pass arrangement and 80 mm dia. and capable of with standing nominal seat pressure of 10.20 Kg/Cm 2 as per IS: 5312 (Part-I) 2004 |
97 | Providing and laying suitable size copper PVC insulated armoured power 3.5 core cable conforming to BIS 1554 (part-I) –1988 of latest with upto date amendments L&T/Finolex make form meter of HPSEB- to CB and form CB to Bus bar switch and starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipe solder, nuts and bolts, cable glands, etc. laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer. Supply side 2.5 sqmm or of Suitable sizes. |
98 | Supply of Kirloskar/Leader or JSV approved make 100 mm dia. cast Iron class PN-1.00 double flanged (swing check type) reflux valve having bye pass arrangement and 100 mm dia. of rising i.e. 100 mm for with standing nominal seat pressure of 10.20 Kg/Cm 2 as per IS: 5312 (Part-I) 2004 |
99 | Supply of PVC joint less flat water proof cable as per IS: 694-1990 latest with upto date amendments suitable for the pump sets offered from CB to motor including all other electrical equipment / accessories such as thimbles, flexible pipes solder, nuts and bolts, cable glands etc laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities & in case of non acceptance by HPSEB authorities it shall have to be replaced bytender. |
100 | Providing and laying double loop earthing with G.I. wire & G.I plate complete with material such as charcoal, common salt, GI. Pipes, thimbles, nuts and bolts, digging of pits, GI. Wiring and aluminum strips of requiredcapacity conforming to BIS: 3043-1987 latest with upto date amendments for above motors and otherelectrical equipment’s. |
101 | Supply of standard make circular dial pressure gauge 0-16 kg/cm2 range of feibig make with all accessories such s stop cock, copper tubing etc, conforming to IS: 3624-1987 latest with upto date amendments. |
102 | Providing and laying delivery pipe 100 mm dia. and common header 125 mm dia GMS pipe Medium classas perIS:_1239-2004 jointed with MS flanges of table -17 as per IS: 6392-1971 (uptoa length of 10 mtrs ) including rappers, flanges, rubber gaskets, nuts and bolts and specials upto 5 mtrs away from the outer wall of pump houses/well as per layout drawings approved by Engineer-in-Charge. |
103 | Supply of floor/wall mounted power factor shunt capacitor conforming to BIS: 2834-1986 latest with upto date amendments L&T make to raise the prevailing power factorat site to 0.95 for direct connection to induction motor individually of suitable rating each including cable of L&T/Finolex make formbus bar chambertocapacitor andalso including L&T/LK/Kilburn make ICTP switches conforming to IS – 4064 (Part - II) 1978 or latest with HRC fuses (range to be specified by the tendrerer). |
104 | Supply of suitable cable for water level guard |
105 | Supply of supporting clamps. |
106 | Supply of cable clips of required size. |
107 | Erection of all equipment from Sr. No. 61 to 73 including cost of tees, bends, tapers and any other fittings required as per site conditions and as per direction of Engineer-in-charge. |
108 | Pumping Machinery ( LWSS Beri Kamlah, Chej Gawalla, Beri Kothuwan Dhalara ) :- Supply & errection ofsubmersible pump set of KSB/ Calama/ Johnston/ SU/Kirloskar or JSV approved make conforming to BIS:8034-1976 or latest suitable for lifting Water (latest with upto date ammendments) fitted with bronze impellers/ suitable alloye. The pump should be fitted with free flow impellers of bronze/suitable alloys directly coupled to squirrell case electric induction motor of same make as (manufacturer standard) conforming to BIS: 9283-1979 (latest with upto date ammendments ) and totally water proof for submersible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearing & provided with stainless steel thrust bearing plate to with stand vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard errection clamps, manufacturer cable clips & depth gauge etc. The pump shall be suitable for operation on data given below:- |
109 | SITE CONDITIONS:- Total Head36.00mtrs Discharge required 9.11LPS each set. No. of Pump required.2Nos1set act as stand bye. Location of the site of installationof machinery:- The site is located at a distance ofKm from The Altitude of :- The Altitude of place is 700 mtrs above MSL Type of Current:-AC three phase supply with RateVoltage:-415+/-10% Type of water and its Charactristics of water a) Ambient b) Turbidity NTU NTU c) Hardness260 Mg/Ltrs -- d) PH Value5.00 HP-- e)Total Solid Mg/Lts)PH Value -- f) Other -- Length of R/main 400 mtrs Dia of Rising main 100 mm dia. No of working hours. 16 Hours. Limit of Pump (-) 15% (+) 10% of R. M.P. of Pumping2900 RPM (or to be specified by the tenderer) Test run 16 Hours continueously for 7 days. |
110 | Supply of Oil immersed Star Delta Starter of reputed make i.e MEI/Kilburn conforming to BIS 8544 -( Part -II) 1987 latest with upto date amendments for squirrel cage induction motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release and gas-pots, time legs, under voltage release & initial oil filingsuitable for 25 HP motor. |
111 | Supply of MS. Angle iron steel sheet 16 SWG fabricated floor mounting closed (Almirah type) switch board comprising and capable of mounting the following accessories and with all internal electric connections, duly painted. The drawing of panel boardshall be subject to approval of Engineer-in-Charge. |
112 | Ammeter AC supply, 100 mm square type auto electric of AE/ L&T Rishab make of 0-63 Amp. capacity for above motor with selector switches conforming to IS-1248 (Part - II)-1983 latest with upto date amendments. |
113 | Voltmeter AC supply, 100 mm square type auto electric AE/ L&T Rishab make of0 - 500 Voltsrange for above motor with selector switches conforming toIS-1248 (Part - II)-1983 latest with upto date amendments. |
114 | ICTP switches 63 Amp. with HRC fuses of Havells/L&T/standard /crompton make for required motor of 25 HPcapacity and conforming to IS: 4064 (part - II)1978 latest with upto date amendments. |
115 | Bus bar chamber having 3 copper bars of suitable rating for full length of 3 phases and one bar of half the rating of full length for neutralconforming to IS:8084 –1976 and 11354-1985 read with 5578-1985 all latest with upto date amendments of suitable rating. |
116 | MCB/MCCB of 63 Amp suitable for motor of 25.00 HP capacity of Havells /standard /MDS/ Kilburn make to feed motors offered by the tenderer conforming to IS: 2516 (Part - II ) 1985 latest with upto dateamendments with neutral linked under voltage release. |
117 | 3 phase indicator lamps complete with toggle switches for individual motors conforming ti IS 3452 part I & II latest with up to date amendments of 15 watts. |
118 | 50 mm dial Hour run meter of CEE / NEE make of suitable range as per relevant IS specifications. |
119 | Supply of Kirloskar/Leader or JSV approved make cast iron (class PN 1.00 ) double flanged sluice valve of 80mm dia. and capable of with standing nominal seat pressure of 10.20 kg/cm2 as per IS :14846-2000. |
120 | Supply of Kirloskar/Leader or JSV approved make cast iron (class PN-1.00) double flanged (swing check type) reflux valve having bye pass arrangement and 80 mm dia. and capable of with standing nominal seat pressure of 10.20 Kg/Cm 2 as per IS: 5312 (Part-I) 2004 |
121 | Providing and laying suitable size copper PVC insulated armoured power 3.5 core cable conforming to BIS 1554 (part-I) –1988 of latest with upto date amendments L&T/Finolex make form meter of HPSEB- to CB and form CB to Bus bar switch and starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipe solder, nuts and bolts, cable glands, etc. laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer. Supply side 10.00 sqmm or of Suitable sizes. |
122 | Supply of Kirloskar/Leader or JSV approved make 100 mm dia. cast Iron class PN-1.00 double flanged (swing check type) reflux valve having bye pass arrangement and 100 mm dia. of rising i.e. 100 mm for with standing nominal seat pressure of 10.20 Kg/Cm 2 as per IS: 5312 (Part-I) 2004 |
123 | Supply of PVC joint less flat water proof cable as per IS: 694-1990 latest with upto date amendments suitable for the pump sets offered from CB to motor including all other electrical equipment / accessories such as thimbles, flexible pipes solder, nuts and bolts, cable glands etc laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities & in case of non acceptance by HPSEB authorities it shall have to be replaced bytender. |
124 | Providing and laying double loop earthing with G.I. wire & G.I plate complete with material such as charcoal, common salt, GI. Pipes, thimbles, nuts and bolts, digging of pits, GI. Wiring and aluminum strips of requiredcapacity conforming to BIS: 3043-1987 latest with upto date amendments for above motors and otherelectrical equipment’s. |
125 | Supply of standard make circular dial pressure gauge 0-16 kg/cm2 range of feibig make with all accessories such s stop cock, copper tubing etc, conforming to IS: 3624-1987 latest with upto date amendments. |
126 | Providing and laying delivery pipe 100 mm dia. and common header 125 mm dia GMS pipe Medium classas perIS:_1239-2004 jointed with MS flanges of table -17 as per IS: 6392-1971 (uptoa length of 10 mtrs ) including rappers, flanges, rubber gaskets, nuts and bolts and specials upto 5 mtrs away from the outer wall of pump houses/well as per layout drawings approved by Engineer-in-Charge. |
127 | Supply of floor/wall mounted power factor shunt capacitor conforming to BIS: 2834-1986 latest with upto date amendments L&T make to raise the prevailing power factorat site to 0.95 for direct connection to induction motor individually of suitable rating each including cable of L&T/Finolex make formbus bar chambertocapacitor andalso including L&T/LK/Kilburn make ICTP switches conforming to IS – 4064 (Part - II) 1978 or latest with HRC fuses (range to be specified by the tendrerer). |
128 | Supply of suitable cable for water level guard |
129 | Supply of supporting clamps. |
130 | Supply of cable clips of required size. |
131 | Erection of all equipment from Sr. No. 76 to 88 including cost of tees, bends, tapers and any other fittings required as per site conditions and as per direction of Engineer-in-charge. |
132 | Pumping Machinery (LWSS Chej Gawalla) :- Supply & errection ofsubmersible pump set of KSB/Calama/Johnston/SU/Kirloskar or JSV approved make conforming to BIS:8034-1976 or latest suitable for lifting Water (latest with upto date ammendments) fitted with bronze impellers/ suitable alloye. The pump should be fitted with free flow impellers of bronze/suitable alloys directly coupled to squirrell case electric induction motor of same make as (manufacturer standard) conforming to BIS: 9283-1979 (latest with upto date ammendments ) and totally water proof for submersible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearing & provided with stainless steel thrust bearing plate to with stand vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard errection clamps, manufacturer cable clips & depth gauge etc. The pump shall be suitable for operation on data given below:- |
133 | SITE CONDITIONS:- Total Head24.00mtrs Discharge required 9.00LPS each set. No. of Pump required.2Nos1set act as stand bye. Location of the site of installation of machinery:- The site is located at a distance ofKm from The Altitude of :- The Altitude of place is 700 mtrs above MSL Type of Current:-AC three phase supply with RateVoltage:-415+/-10% Type of water and its Charactristics of water a) Ambient b) Turbidity NTU NTU c) Hardness260 Mg/Ltrs -- d) PH Value5.00 HP-- e)Total Solid Mg/Lts)PH Value -- f) Other -- Length of R/main 350 mtrs Dia of Rising main 125 mm dia. No of working hours.16 Hours. Limit of Pump (-) 15% (+) 10% of R. M.P. of Pumping2900 RPM (or to be specified by the tenderer) Test run 16 Hours continueously for 7 days. |
134 | Supply of Air brake type Star Delta Starter of reputed make i.e L&T /Crompton /MEI conforming to BIS 8544 -( Part - II) 1987 latest with upto date amendments for squirrel cage induction motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release and gas-pots, time legs, under voltage release & initial oil filingsuitable for 12.50 HP motor. |
135 | Supply of MS. Angle iron steel sheet 16 SWG fabricated floor mounting closed (Almirah type) switch board comprising and capable of mounting the following accessories and with all internal electric connections, duly painted. The drawing of panel boardshall be subject to approval of Engineer-in-Charge. |
136 | Ammeter AC supply, 100 mm square type auto electric of AE/ L&T Rishab make of 0-63 Amp. capacity for above motor with selector switches conforming to IS-1248 (Part - II)-1983 latest with upto date amendments. |
137 | Voltmeter AC supply, 100 mm square type auto electric AE/ L&T Rishab make of0 - 500 Voltsrange for above motor with selector switches conforming toIS-1248 (Part - II)-1983 latest with upto date amendments. |
138 | ICTP switches 63 Amp. with HRC fuses of Havells/L&T/standard /crompton make for required motor of 12.50 HPcapacity and conforming to IS: 4064 (part - II)1978 latest with upto date amendments. |
139 | Bus bar chamber having 3 copper bars of suitable rating for full length of 3 phases and one bar of half the rating of full length for neutralconforming to IS:8084 –1976 and 11354-1985 read with 5578-1985 all latest with upto date amendments of suitable rating. |
140 | MCB/MCCB of 63 Amp suitable for motor of 12.50 HP capacity of Havells /standard /MDS/ Kilburn make to feed motors offered by the tenderer conforming to IS: 2516 (Part - II ) 1985 latest with upto dateamendments with neutral linked under voltage release. |
141 | 3 phase indicator lamps complete with toggle switches for individual motors conforming to IS 3452 part I & II latest with up to date amendments of 15 watts. |
142 | 50 mm dial Hour run meter of CEE / NEE make of suitable range as per relevant IS specifications. |
143 | Supply of Kirloskar/Leader or JSV approved make cast iron (class PN 1.00 ) double flanged sluice valve of 100 mm dia. and capable of with standing nominal seat pressure of 10.20 kg/cm2 as per IS :14846-2000. |
144 | Supply of Kirloskar/Leader or JSV approved make cast iron (class PN-1.00) double flanged (swing check type) reflux valve having bye pass arrangement and 100 mm dia. and capable of with standing nominal seat pressure of 10.20 Kg/Cm 2 as per IS: 5312 (Part-I) 2004 |
145 | Providing and laying suitable size copper PVC insulated armoured power 3.5 core cable conforming to BIS 1554 (part-I) –1988 of latest with upto date amendments L&T/Finolex make form meter of HPSEB- to CB and form CB to Bus bar switch and starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipe solder, nuts and bolts, cable glands, etc. laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer. Supply side 4.0 sqmm or of Suitable sizes. |
146 | Supply of Kirloskar/Leader or JSV approved make 125 mm dia. cast Iron class PN-1.00 double flanged (swing check type) reflux valve having bye pass arrangement and 125 mm dia. of rising i.e. 125 mm for with standing nominal seat pressure of 10.20 Kg/Cm 2 as per IS: 5312 (Part-I) 2004 |
147 | Supply of PVC joint less flat water proof cable as per IS: 694-1990 latest with upto date amendments suitable for the pump sets offered from CB to motor including all other electrical equipment / accessories such as thimbles, flexible pipes solder, nuts and bolts, cable glands etc laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities & in case of non acceptance by HPSEB authorities it shall have to be replaced bytender. |
148 | Providing and laying double loop earthing with G.I. wire & G.I plate complete with material such as charcoal, common salt, GI. Pipes, thimbles, nuts and bolts, digging of pits, GI. Wiring and aluminum strips of requiredcapacity conforming to BIS: 3043-1987 latest with upto date amendments for above motors and otherelectrical equipment’s. |
149 | Supply of standard make circular dial pressure gauge 0-16 kg/cm2 range of feibig make with all accessories such s stop cock, copper tubing etc, conforming to IS: 3624-1987 latest with upto date amendments. |
150 | Providing and laying delivery pipe 125 mm dia. and common header 150 mm dia GMS pipe Medium classas perIS:_1239-2004 jointed with MS flanges of table -17 as per IS: 6392-1971 (uptoa length of 10 mtrs ) including rappers, flanges, rubber gaskets, nuts and bolts and specials upto 5 mtrs away from the outer wall of pump houses/well as per layout drawings approved by Engineer-in-Charge. |
151 | Supply of floor/wall mounted power factor shunt capacitor conforming to BIS: 2834-1986 latest with upto date amendments L&T make to raise the prevailing power factorat site to 0.95 for direct connection to induction motor individually of suitable rating each including cable of L&T/Finolex make formbus bar chambertocapacitor andalso including L&T/LK/Kilburn make ICTP switches conforming to IS – 4064 (Part - II) 1978 or latest with HRC fuses (range to be specified by the tendrerer). |
152 | Supply of suitable cable for water level guard |
153 | Supply of supporting clamps. |
154 | Supply of cable clips of required size. |
155 | Erection of all equipment from Sr. No. 91 to 103 including cost of tees, bends, tapers and any other fittings required as per site conditions and as per direction of Engineer-in-charge. |
156 | Pumping Machinery (LWSS Sadhoti ) :- Supply & errection ofsubmersible pump set of KSB/Calama/Johnston/SU/Kirloskar or JSV approved make conforming to BIS:8034-1976 or latest suitable for lifting Water (latest with upto date ammendments) fitted with bronze impellers/ suitable alloye. The pump should be fitted with free flow impellers of bronze/suitable alloys directly coupled to squirrell case electric induction motor of same make as (manufacturer standard) conforming to BIS: 9283-1979 (latest with upto date ammendments ) and totally water proof for submersible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearing & provided with stainless steel thrust bearing plate to with stand vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard errection clamps, manufacturer cable clips & depth gauge etc. The pump shall be suitable for operation on data given below:- |
157 | SITE CONDITIONS:- Total Head6.00mtrs Discharge required 3.00LPS each set. No. of Pump required.2Nos1set act as stand bye. Location of the site of installation of machinery:-The site is located at a distance ofKm from The Altitude of :- The Altitude of place is 809 mtrs above MSL Type of Current:-AC three phase supply with RateVoltage:-415+/-10% Type of water and its Charactristics of water a) Ambient b) Turbidity NTU NTU c) Hardness260 Mg/Ltrs -- d) PH Value5.00 HP-- e)Total Solid Mg/Lts)PH Value -- f) Other --Length of R/main 20 mtrs Dia of Rising main 32 mm dia. No of working hours. 16 Hours. Limit of Pump (-) 15% (+) 10% of R. M.P. of Pumping2900 RPM (or to be specified by the tenderer) Test run 16 Hours continueously for 7 days. |
158 | Pumping Machinery (LWSS Bag) :- Supply & errection ofsubmersible pump set of KSB/Calama/Johnston/SU/Kirloskar or JSV approved make conforming to BIS:8034-1976 or latest suitable for lifting Water (latest with upto date ammendments) fitted with bronze impellers/ suitable alloye. The pump should be fitted with free flow impellers of bronze/suitable alloys directly coupled to squirrell case electric induction motor of same make as (manufacturer standard) conforming to BIS: 9283-1979 (latest with upto date ammendments ) and totally water proof for submersible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearing & provided with stainless steel thrust bearing plate to with stand vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard errection clamps, manufacturer cable clips & depth gauge etc. The pump shall be suitable for operation on data given below:- |
159 | SITE CONDITIONS:- Total Head6.00mtrs Discharge required 3.50LPS each set. No. of Pump required.2Nos1set act as stand bye. Location of the site of installation of machinery:- The site is located at a distance ofKm from The Altitude of :- The Altitude of place is 864 mtrs above MSL Type of Current:-AC three phase supply with RateVoltage:-415+/-10% Type of water and its Charactristics of water a) Ambient b) Turbidity NTU NTU c) Hardness260 Mg/Ltrs -- d) PH Value5.00 HP-- e)Total Solid Mg/Lts)PH Value -- f) Other -- Length of R/main 20 mtrs Dia of Rising main 32 mm dia. No of working hours.16 Hours. Limit of Pump (-) 15% (+) 10% of R. M.P. of Pumping2900 RPM (or to be specified by the tenderer) Test run 16 Hours continueously for 7 days. |
160 | Centrifugal Pump (LWSS Tourkhola):- Supply & errection ofhorizontal spindle horizontal split casing/end suctions (back pull out arrangement) Single/double/multistage centrifugal pumps or combination of pumps in series/parellel of Mather & Platt/KSB/ Kirloskar or JSV approved make conforming to BIS 1520-1980) pump (Latest with up to date amendments, read with BIS: 9137-1978(latest edition)suitable for lifting clear/raw water of under mentioned characteristics with bronze/Suitable alloy, priming funnels, casing ring andshaftmotor of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on acommon MS/Cast steel plate (base platefrom the principal manufacturer of pumping set) to coupling 3 phase squirrel cage electric induction motor of standard make such as Kirloskar/ NGEF/crompton or JSV approved make conforming to IS 12615-2018 and should be energy efficient minimum IE2 compliant and totally enclosed fan cooled (TEFC) type ( latest with upto date ammendments) it should include the cost of bearings, nuts & bolts, painting etc. and shall be and suitable for operation on the date given below: |
161 | SITE CONDITIONS:- Total Head465.00 mtrs Discharge required6.11 LPS each set. No. of Pump required. 1.00 No set Length of R/main 1810.00 mtrs. Dia of R/main100mm dia Location of the site of installation of machinery-The site is located at a distance of Km by road &KM on head load (for the installation of both machinery). Head Load (for the installation of both machinery). The Altitude of :-The Altitude of place is1265 mtrs above MSL Type of Current:- AC three phase supply with Rate Voltage:-415+ Type of water and its Charactristics of water a) Ambient Temperature b) Turbidity NTU NTU c) Hardness260 Mg/Ltrs -- d) PH Value 7.5-- e)Total Solid Mg/Lts)PH Value-- No of working hours.16 Hours. Limit of Pump(-) 15% (+) 10% R. M.P. of PumpingRPM(or to be specified by the tenderer) Test run16Hours continueously for 7 days. |
162 | Providing ICTP Main Switch 250 Amp with HRC fuses / Side handled operated Change over switch of L&T/Crompton/Standard/Havells make suitable capacity Operational rating as per IS: 4064 (Part - II) 1978 with up to date amendments immediately after the power meter of HPSEB |
163 | Providing M.S. sheet, steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm, duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories with all internal connections:- |
164 | O.C.B. 200 Amp. Havell/MDS/Standard of make of suitable capacity on incoming feeder with or without initial oil filling as the case may be withneutral linkedunder voltage releases as per IS: 2516 (Part - II) 1985 with up to date amendments with. |
165 | E.L.R. of Havell/MDS/INDETEC make as per IS: 2516 (Part - II) 1985 with upto date amendmentwhich should have control box operating handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape etc. It should also be lifted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end. |
166 | The voltage monitor relay of L&T/AE make three phase with all protection and usual indicator and electric siren against single phasing low voltage, high voltage, reverse phasing, over loading and phase voltage difference as per IS: 1248 (Part - II ) 1983 (Latest edition). |
167 | 100mm square type A.C. supply voltmeter of AE/L&T Rishab make of suitable range with selector switches as per IS: 4064 (Part - II ) -1978 with up to date amendments. |
168 | Power factor meter of AE/L&T Rishab make as perIS: 1248 (Part - V ) 1983(Latest edition) with up to date amendments of suitable rating. |
169 | Frequency meter of AE/ L&T Rishab make as perIS: 1248 (Part - IV ) 1983( Latest edition) with up to date amendments of suitable rating. |
170 | Bus bar chamber with copper strips having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS: 8084-1976 and IS: 11354-1985 read with IS 5578-1985 with up to date amendments 250 Amp. |
171 | ICTP switches with HRC fuses ofL&T/ Standard/Havells make and of suitable capacity as per IS: 4064 (Part - II) -1978 with up to date amendments. 250 Amp. |
172 | Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 ( P-I & II) with up to date amendments. |
173 | 100mmSquare type AC supplyAmmeter of AE /L&T Rishab make of suitable range (0-200) with selector switches and CTS operated as per IS:1248 (P-II) 1983 with up to date amendments. |
174 | Capacitor of L&T make as per IS:2834 -1986 with up to date amendments toraise the power factor at site to 0.95 for direct connections to induction motor individuallyof 21 KVAr ratingaccordingto HP offered including cables as per relevant ISI code (of L&T/Finolex make) from bus bar chamber to capacitor and also including ICTP switches of appropriate rangeas per IS: 4064 (Part - II) 1978 withupto date amendments |
175 | Providing suitable Auto Trasformer starter of M.E.I / Kilburn.make as per IS:8544 (Part - IV ) -1987 with up to date amendments for Squirrel Cage motor mounted on panel board with magnetic type overload release and dashpot time lag, under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS 1248 (P-V)-1983 with up to date amendments. |
176 | Providing Hour run meter of recommended make as per IS: 722 (Latest edition) |
177 | Providing doubleflanged Cast iron sluice valve of Kirloskar/Leader or JSV approved make for the suction pipe and capable of withstanding the normal seat pressure as per IS: 14846-2000 with up to date amendments. (Class PN-1.00, size equal to dia of suction pipe) |
178 | Providing double flangedCast steel sluice valve of Kirloskar/Leader or JSV approved make and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS : 1414 / API - 600 (Class ASA-300, having size one step higher to delivery of pump) . |
179 | Providing double flangedCast steel reflux valve of Kirloskar/Leader or JSV approvedmake and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS:1868/API-600 (Class ASA-300, having by pass arrangement and size one step higher to delivery of pump). |
180 | Providing double flanged Cast steel 100 mm non return valve of Kirloskar/Leader or JSV approvedmake having bye pass arrangement for rising main and capable of with standing normal seat pressure of 52 kg/cm2 as per BS:1868/API-600 (Class ASA-300) . |
181 | Providing 100mm dia. circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 75 Kg/cm2 |
182 | Providing 100mm dia. vacume dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 760 mercury. |
183 | Installation of all the items appearing at Serial No. 109 to115.01 |
184 | Providing and fixing double flanged 200 mm piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the rising main respectively complete with all specials such as bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as indicated in the drawing No.2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS: 1364-1983. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated under item No.1. |
185 | The size of the various components to be as under:- |
186 | (i) Suction pipe 200 mm dia Min. length = 10 mtr. |
187 | (ii)Delivery pipe 150 mm dia -do-= 6 mtr. |
188 | (iii) Common Header 200 mm dia-do-= 6 mtr. |
189 | and will extend up to 5 meters from the outer wall of the pump house in the direction to be jointed. |
190 | Providing and laying copper PVC insulated armoured power cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of L&T/Finolex make including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor. |
191 | (i)Motor side:50mm2 Min length = 20 mtrs. |
192 | (ii)Supply side: 70 mm2Min. length =10 mtrs. |
193 | Providing and fixing double loop earthing and G.I. plate 600 mm x 600mm x 3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 32 mm x 3_mm G.I. strips & G.I. wire as per IS: 3043 -1987 withup to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect. |
194 | Centrifugal Pump (LWSS Koon Deyol):- Supply & errection ofhorizontal spindle horizontal split casing/end suctions (back pull out arrangement) Single/double/multistage centrifugal pumps or combination of pumps in series/parellel of Mather & Platt/KSB/ Kirloskar or JSV approved make conforming to BIS 1520-1980) pump (Latest with up to date amendments, read with BIS: 9137-1978(latest edition)suitable for lifting clear/raw water of under mentioned characteristics with bronze/Suitable alloy, priming funnels, casing ring andshaftmotor of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on acommon MS/Cast steel plate (base platefrom the principal manufacturer of pumping set) to coupling 3 phase squirrel cage electric induction motor of standard make such as Kirloskar/ NGEF/crompton or JSV approved make conforming to IS 12615-2018 and should be energy efficient minimum IE2 compliant and totally enclosed fan cooled (TEFC) type ( latest with upto date ammendments) it should include the cost of bearings, nuts & bolts, painting etc. and shall be and suitable for operation on the date given below: |
195 | SITE CONDITIONS:- Total Head338.00 mtrs Discharge required4.40 LPS each set. No. of Pump required. 1.00 No setLength of R/main 880.00 mtrs. Dia of R/main80mm dia Location of the site of installation of machinery-The site is located at a distance of Km by road &KM on head load (for the installation of both machinery). The Altitude of :-The Altitude of place is900 mtrs above MSL Type of Current:- AC three phase supply with Rate Voltage:-415+ Type of water and its Charactristics of water a) Ambient Temperature b) Turbidity NTU NTU c) Hardness260 Mg/Ltrs -- d) PH Value 7.5-- e)Total Solid Mg/Lts)PH Value-- No of working hours.16 Hours. Limit of Pump(-) 15% (+) 10% R. M.P. of PumpingRPM(or to be specified by the tenderer) Test run16Hours continueously for 7 days. |
196 | Providing ICTP Main Switch 250 Amp with HRC fuses / Side handled operated Change over switch of L&T/Crompton/Standard/Havells make suitable capacity Operational rating as per IS: 4064 (Part - II) 1978 with up to date amendments immediately after the power meter of HPSEB |
197 | Providing M.S. sheet, steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm, duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories with all internal connections:- |
198 | O.C.B. 200 Amp. Havell/MDS/Standard of make of suitable capacity on incoming feeder with or without initial oil filling as the case may be withneutral linkedunder voltage releases as per IS: 2516 (Part - II) 1985 with up to date amendments with. |
199 | E.L.R. of Havell/MDS/INDETEC make as per IS: 2516 (Part - II) 1985 with upto date amendmentwhich should have control box operating handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape etc. It should also be lifted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end. |
200 | The voltage monitor relay of L&T/AE make three phase with all protection and usual indicator and electric siren against single phasing low voltage, high voltage, reverse phasing, over loading and phase voltage difference as per IS: 1248 (Part - II ) 1983 (Latest edition). |
201 | 100mm square type A.C. supply voltmeter of AE/L&T Rishab make of suitable range with selector switches as per IS: 4064 (Part - II ) -1978 with up to date amendments. |
202 | Power factor meter of AE/L&T Rishab make as perIS: 1248 (Part - V ) 1983(Latest edition) with up to date amendments of suitable rating. |
203 | Frequency meter of AE/ L&T Rishab make as perIS: 1248 (Part - IV ) 1983( Latest edition) with up to date amendments of suitable rating. |
204 | Bus bar chamber with copper strips having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS: 8084-1976 and IS: 11354-1985 read with IS 5578-1985 with up to date amendments 250 Amp. |
205 | ICTP switches with HRC fuses ofL&T/ Standard/Havells make and of suitable capacity as per IS: 4064 (Part - II) -1978 with up to date amendments. 250 Amp. |
206 | Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 ( P-I & II) with up to date amendments. |
207 | 100mmSquare type AC supplyAmmeter of AE /L&T Rishab make of suitable range (0-200) with selector switches and CTS operated as per IS:1248 (P-II) 1983 with up to date amendments. |
208 | Capacitor of L&T make as per IS:2834 -1986 with up to date amendments toraise the power factor at site to 0.95 for direct connections to induction motor individuallyof 21 KVAr ratingaccordingto HP offered including cables as per relevant ISI code (of L&T/Finolex make) from bus bar chamber to capacitor and also including ICTP switches of appropriate rangeas per IS: 4064 (Part - II) 1978 withupto date amendments |
209 | Providing suitable Auto Trasformer starter of M.E.I / Kilburn.make as per IS:8544 (Part - IV ) -1987 with up to date amendments for Squirrel Cage motor mounted on panel board with magnetic type overload release and dashpot time lag, under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS 1248 (P-V)-1983 with up to date amendments. |
210 | Providing Hour run meter of recommended make as per IS: 722 (Latest edition) |
211 | Providing doubleflanged Cast iron sluice valve of Kirloskar/Leader or JSV approved make for the suction pipe and capable of withstanding the normal seat pressure as per IS: 14846-2000 with up to date amendments. (Class PN-1.00, size equal to dia of suction pipe) |
212 | Providing double flangedCast steel sluice valve of Kirloskar/Leader or JSV approved make and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS : 1414 / API - 600 (Class ASA-300, having size one step higher to delivery of pump) . |
213 | Providing double flangedCast steel reflux valve of Kirloskar/Leader or JSV approvedmake and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS:1868/API-600 (Class ASA-300, having by pass arrangement and size one step higher to delivery of pump). |
214 | Providing double flanged Cast steel 100 mm non return valve of Kirloskar/Leader or JSV approvedmake having bye pass arrangement for rising main and capable of with standing normal seat pressure of 52 kg/cm2 as per BS:1868/API-600 (Class ASA-300) . |
215 | Providing 100mm dia. circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 75 Kg/cm2 |
216 | Providing 100mm dia. vacume dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 760 mercury. |
217 | Installation of all the items appearing at Serial No. 109 to115.01 |
218 | Providing and fixing double flanged 200 mm piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the rising main respectively complete with all specials such as bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as indicated in the drawing No.2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS: 1364-1983. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated under item No.1. |
219 | The size of the various components to be as under:- |
220 | (i) Suction pipe 200 mm dia Min. length = 10 mtr. |
221 | (ii)Delivery pipe 150 mm dia -do-= 6 mtr. |
222 | (iii) Common Header 200 mm dia-do-= 6 mtr. |
223 | and will extend up to 5 meters from the outer wall of the pump house in the direction to be jointed. |
224 | Providing and laying copper PVC insulated armoured power cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of L&T/Finolex make including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor. |
225 | (i)Motor side:50mm2 Min length = 20 mtrs. |
226 | (ii)Supply side: 70 mm2Min. length =10 mtrs. |
227 | Providing and fixing double loop earthing and G.I. plate 600 mm x 600mm x 3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 32 mm x 3_mm G.I. strips & G.I. wire as per IS: 3043 -1987 withup to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect. |
228 | Centrifugal Pump (LWSS Koon Deyol):- Supply & errection ofhorizontal spindle horizontal split casing/end suctions (back pull out arrangement) Single/double/multistage centrifugal pumps or combination of pumps in series/parellel of Mather & Platt/KSB/ Kirloskar or JSV approved make conforming to BIS 1520-1980) pump (Latest with up to date amendments, read with BIS: 9137-1978(latest edition)suitable for lifting clear/raw water of under mentioned characteristics with bronze/Suitable alloy, priming funnels, casing ring andshaftmotor of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on acommon MS/Cast steel plate (base platefrom the principal manufacturer of pumping set) to coupling 3 phase squirrel cage electric induction motor of standard make such as Kirloskar/ NGEF/crompton or JSV approved make conforming to IS 12615-2018 and should be energy efficient minimum IE2 compliant and totally enclosed fan cooled (TEFC) type ( latest with upto date ammendments) it should include the cost of bearings, nuts & bolts, painting etc. and shall be and suitable for operation on the date given below: |
229 | SITE CONDITIONS:- Total Head450.00 mtrs Discharge required3.50 LPS each set. No. of Pump required. 1.00 No set Length of R/main 2200.00 mtrs. Dia of R/main65mm dia Location of the site of installation of machinery-The site is located at a distance of Km by road &KM on head load (for the installation of both machinery). The Altitude of :-The Altitude of place is930 mtrs above MSL Type of Current:- AC three phase supply with Rate Voltage:-415+ Type of water and its Charactristics of water a) Ambient Temperature b) Turbidity NTU NTU c) Hardness260 Mg/Ltrs -- d) PH Value 7.5-- e)Total Solid Mg/Lts)PH Value-- No of working hours.16 Hours. Limit of Pump(-) 15% (+) 10% R. M.P. of PumpingRPM(or to be specified by the tenderer) Test run16Hours continueously for 7 days. |
230 | Providing ICTP Main Switch 100 Amp with HRC fuses / Side handled operated Change over switch of L&T/Crompton/Standard/Havells make suitable capacity Operational rating as per IS: 4064 (Part - II) 1978 with up to date amendments immediately after the power meter of HPSEB |
231 | Providing M.S. sheet, steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm, duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories with all internal connections:- |
232 | M.C.B. 100 Amp. Havell/MDS/Standard of make of suitable capacity on incoming feeder with or without initial oil filling as the case may be withneutral linkedunder voltage releases as per IS: 2516 (Part - II) 1985 with up to date amendments with. |
233 | E.L.R. of Havell/MDS/INDETEC make as per IS: 2516 (Part - II) 1985 with upto date amendmentwhich should have control box operating handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape etc. It should also be lifted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end. |
234 | The voltage monitor relay of L&T/AE make three phase with all protection and usual indicator and electric siren against single phasing low voltage, high voltage, reverse phasing, over loading and phase voltage difference as per IS: 1248 (Part - II ) 1983 (Latest edition). |
235 | 100mm square type A.C. supply voltmeter of AE/L&T Rishab make of suitable range with selector switches as per IS: 4064 (Part - II ) -1978 with up to date amendments. |
236 | Power factor meter of AE/L&T Rishab make as perIS: 1248 (Part - V ) 1983(Latest edition) with up to date amendments of suitable rating. |
237 | Frequency meter of AE/ L&T Rishab make as perIS: 1248 (Part - IV ) 1983( Latest edition) with up to date amendments of suitable rating. |
238 | Bus bar chamber with copper strips having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS: 8084-1976 and IS: 11354-1985 read with IS 5578-1985 with up to date amendments 100 Amp. |
239 | ICTP switches with HRC fuses ofL&T/ Standard/Havells make and of suitable capacity as per IS: 4064 (Part - II) -1978 with up to date amendments. 100 Amp. |
240 | Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 ( P-I & II) with up to date amendments. |
241 | 100mmSquare type AC supplyAmmeter of AE /L&T Rishab make of suitable range (0-200) with selector switches and CTS operated as per IS:1248 (P-II) 1983 with up to date amendments. |
242 | Capacitor of L&T make as per IS:2834 -1986 with up to date amendments toraise the power factor at site to 0.95 for direct connections to induction motor individuallyof 9 KVAr ratingaccordingto HP offered including cables as per relevant ISI code (of L&T/Finolex make) from bus bar chamber to capacitor and also including ICTP switches of appropriate rangeas per IS: 4064 (Part - II) 1978 withupto date amendments |
243 | Providing suitable Oil immersed Star Delta starter of M.E.I / Kilburn make as per IS:8544 (Part - II ) -1987 with up to date amendments for Squirrel Cage motor mounted on panel board with magnetic type overload release and dashpot time lag, under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS 1248 (P-V)-1983 with up to date amendments. |
244 | Providing Hour run meter of recommended make as per IS: 722 (Latest edition) |
245 | Providing double flanged Cast iron sluice valve of Kirloskar/Leader or JSV approved make for the suction pipe and capable of withstanding the normal seat pressure as per IS: 14846-2000 with up to date amendments. (Class PN-1.00, size equal to dia of suction pipe) |
246 | Providing double flanged Cast steel sluice valve of Kirloskar/Leader or JSV approved make and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS:1414/API-600 (Class ASA-300, having size one step higher to delivery of pump). |
247 | Providing double flangedCast steel reflux valve of Kirloskar/Leader or JSV approved make and capable of with standing nominal seat pressure of 52 kg/cm2 as perBS:1868/API-600 (Class ASA-300, having by pass arrangement and size one step higher to delivery of pump).. |
248 | Providing double flangedCast steel 65 mm non return valve of Kirloskar/Leader or JSV approved make having bye pass arrangement for rising main and capable of with standing normal sseat pressure of 52 kg/cm2 as per BS:1868/API-600 (Class ASA-300). . |
249 | Providing 100mm dia. circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 75 Kg/cm2 |
250 | Providing 100mm dia. vacume dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 760 mercury. |
251 | Installation of all the items appearing at Serial No. 135 to141.01 |
252 | Providing and fixing double flanged 80 mm piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the rising main respectively complete with all specials such as bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as indicated in the drawing No.2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS: 1364-1983. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated under item No.1. |
253 | The size of the various components to be as under:- |
254 | (i) Suction pipe 80 mm dia Min. length = 10 mtr. |
255 | (ii)Delivery pipe65 mm dia -do-= 6 mtr. |
256 | (iii) Common Header 80 mm dia-do-= 6 mtr. |
257 | and will extend up to 5 meters from the outer wall of the pump house in the direction to be jointed. |
258 | Providing and laying copper PVC insulated armoured power cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of L&T/Finolex make including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor. |
259 | (i)Motor side:10mm2 Min length = 20 mtrs. |
260 | (ii)Supply side: 16 mm2Min. length =10 mtrs. |
261 | Providing and fixing double loop earthing and G.I. plate 600 mm x 600mm x 3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 32 mm x 3_mm G.I. strips & G.I. wire as per IS: 3043 -1987 withup to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect. |
262 | Centrifugal Pump (LWSS Lekhrer Phannel):- Supply & errection ofhorizontal spindle horizontal split casing/end suctions (back pull out arrangement) Single /double /multistage centrifugal pumps or combination of pumps in series/parellel of Mather & Platt/KSB/ Kirloskar or JSV approved make conforming to BIS 1520-1980) pump (Latest with up to date amendments, read with BIS: 9137-1978(latest edition)suitable for lifting clear/raw water of under mentioned characteristics with bronze/Suitable alloy, priming funnels, casing ring andshaftmotor of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on acommon MS/Cast steel plate (base platefrom the principal manufacturer of pumping set) to coupling 3 phase squirrel cage electric induction motor of standard make such as Kirloskar/ NGEF/Crompton or JSV approved make conforming to IS 12615-2018 and should be energy efficient minimum IE2 compliant and totally enclosed fan cooled (TEFC) type (latest with upto date ammendments) it should include the cost of bearings, nuts & bolts, painting etc. and shall be and suitable for operation on the date given below: |
263 | SITE CONDITIONS:- Total Head235.00 mtrs Discharge required2.36 LPS each set. No. of Pump required. 1.00 No set Length of R/main 600.00 mtrs. Dia of R/main65mm dia Location of the site of installation of machinery-The site is located at a distance of Km by road &KM on head load (for the installation of both machinery). The Altitude of :-The Altitude of place is1050 mtrs above MSL Type of Current:- AC three phase supply with Rate Voltage:-415+ Type of water and its Charactristics of water a) Ambient Temperature b) Turbidity NTU NTU c) Hardness260 Mg/Ltrs -- d) PH Value 7.5-- e)Total Solid Mg/Lts)PH Value-- No of working hours.16 Hours. Limit of Pump(-) 15% (+) 10% R. M.P. of PumpingRPM(or to be specified by the tenderer) Test run16Hours continueously for 7 days. |
264 | Providing ICTP Main Switch 63 Amp with HRC fuses / Side handled operated Change over switch of L&T/Crompton/Standard/Havells make suitable capacity Operational rating as per IS: 4064 (Part - II) 1978 with up to date amendments immediately after the power meter of HPSEB |
265 | Providing M.S. sheet, steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm, duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories with all internal connections:- |
266 | M.C.B. 63 Amp. Havell/MDS/Standard of make of suitable capacity on incoming feeder with or without initial oil filling as the case may be withneutral linkedunder voltage releases as per IS: 2516 (Part - II) 1985 with up to date amendments with. |
267 | E.L.C.B of Havell/MDS/INDETEC make as per IS: 2516 (Part - II) 1985 with upto date amendmentwhich should have control box operating handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape etc. It should also be lifted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end. |
268 | The voltage monitor relay of L&T/AE make three phase with all protection and usual indicator and electric siren against single phasing low voltage, high voltage, reverse phasing, over loading and phase voltage difference as per IS: 1248 (Part - II ) 1983 (Latest edition). |
269 | 100mm square type A.C. supply voltmeter of AE/L&T Rishab make of suitable range with selector switches as per IS: 4064 (Part - II ) -1978 with up to date amendments. |
270 | Power factor meter of AE/L&T Rishab make as perIS: 1248 (Part - V ) 1983(Latest edition) with up to date amendments of suitable rating. |
271 | Frequency meter of AE/ L&T Rishab make as perIS: 1248 (Part - IV ) 1983( Latest edition) with up to date amendments of suitable rating. |
272 | Bus bar chamber with copper strips having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS: 8084-1976 and IS: 11354-1985 read with IS 5578-1985 with up to date amendments 63 Amp. |
273 | ICTP switches with HRC fuses ofL&T/ Standard/Havells make and of suitable capacity as per IS: 4064 (Part - II) -1978 with up to date amendments. 63 Amp. |
274 | Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 ( P-I & II) with up to date amendments. |
275 | 100mmSquare type AC supplyAmmeter of AE /L&T Rishab make of suitable range (0-60) with selector switches and CTS operated as per IS:1248 (P-II) 1983 with up to date amendments. |
276 | Capacitor of L&T make as per IS:2834 -1986 with up to date amendments toraise the power factor at site to 0.95 for direct connections to induction motor individuallyof 5 KVAr ratingaccordingto HP offered including cables as per relevant ISI code (of L&T/Finolex make) from bus bar chamber to capacitor and also including ICTP switches of appropriate rangeas per IS: 4064 (Part - II) 1978 withupto date amendments |
277 | Providing suitable Oil immersed Star Delta starter of M.E.I / Kilburn make as per IS:8544 (Part - II ) -1987 with up to date amendments for Squirrel Cage motor mounted on panel board with magnetic type overload release and dashpot time lag, under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS 1248 (P-V)-1983 with up to date amendments. |
278 | Providing Hour run meter of recommended make as per IS: 722 (Latest edition) |
279 | Providing doubleflanged Cast iron sluice valve of Kirloskar/Leader or JSV approved make for the suction pipe and capable of withstanding the normal seat pressure as per IS:14846-2000 with up to date amendments (Class PN-1, size equal to dia of suction pipe). |
280 | Providing double flanged Cast steel sluice valve of Kirloskar / Leader or JSV approved make and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS:1414/API-600 (Class ASA-300 having size one step higher to delivery of pump). |
281 | Providing double flanged Cast steel reflux valve of Kirloskar / Leader or JSV approvedmake and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS:1868/API-600 (Class ASA-300 having by pass arrangement and size one step higher to delivery of pump). |
282 | Providing double flangedCast steel 65 mm non return valve of Kirloskar / Leader or JSV approved make having bye pass arrangement for rising main and capable of with standing normal sseat pressure of 52 kg/cm2 as per BS:1868/API-600 (Class ASA-300). |
283 | Providing 100mm dia. circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 75 Kg/cm2 |
284 | Providing 100mm dia. vacume dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 760 mercury. |
285 | Installation of all the items appearing at Serial No. 148 to154.01 |
286 | Providing and fixing double flanged 80 mm piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the rising main respectively complete with all specials such as bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as indicated in the drawing No.2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS: 1364-1983. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated under item No.1. |
287 | The size of the various components to be as under:- |
288 | (i) Suction pipe 80 mm dia Min. length = 10 mtr. |
289 | (ii)Delivery pipe 65 mm dia -do-= 6 mtr. |
290 | (iii) Common Header 80 mm dia-do-= 6 mtr. |
291 | and will extend up to 5 meters from the outer wall of the pump house in the direction to be jointed. |
292 | Providing and laying copper PVC insulated armoured power cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of L&T/Finolex make including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor. |
293 | (i)Motor side:4mm2 Min length = 20 mtrs. |
294 | (ii)Supply side: 6 mm2Min. length =10 mtrs. |
295 | Providing and fixing double loop earthing and G.I. plate 600 mm x 600mm x 3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 32 mm x 3_mm G.I. strips & G.I. wire as per IS: 3043 -1987 withup to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect. |
296 | Centrifugal Pump (LWSS Gaddidhar( Bag) Ph-1):- Supply & errection ofhorizontal spindle horizontal split casing/end suctions (back pull out arrangement) Single /double /multistage centrifugal pumps or combination of pumps in series/parellel of Mather & Platt/KSB/ Kirloskar or JSV approved make conforming to BIS 1520-1980) pump (Latest with up to date amendments, read with BIS: 9137-1978(latest edition)suitable for lifting clear/raw water of under mentioned characteristics with bronze/Suitable alloy, priming funnels, casing ring andshaftmotor of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on acommon MS/Cast steel plate (base platefrom the principal manufacturer of pumping set) to coupling 3 phase squirrel cage electric induction motor of standard make such as Kirloskar/ NGEF/Crompton or JSV approved make conforming to IS 12615-2018 and should be energy efficient minimum IE2 compliant and totally enclosed fan cooled (TEFC) type (latest with upto date ammendments) it should include the cost of bearings, nuts & bolts, painting etc. and shall be and suitable for operation on the date given below: |
297 | SITE CONDITIONS:- Total Head230.00 mtrs Discharge required3.50 LPS each set. No. of Pump required. 1.00 No setLength of R/main 600.00 mtrs. Dia of R/main65mm dia Location of the site of installation of machinery-The site is located at a distance of Km by road &KM on head load (for the installation of both machinery). The Altitude of :-The Altitude of place is1100 mtrs above MSL Type of Current:- AC three phase supply with Rate Voltage:-415+ Type of water and its Charactristics of water a) Ambient Temperature b) Turbidity NTU NTU c) Hardness260 Mg/Ltrs -- d) PH Value 7.5-- e)Total Solid Mg/Lts)PH Value-- No of working hours.16 Hours. Limit of Pump(-) 15% (+) 10% R. M.P. of PumpingRPM(or to be specified by the tenderer) Test run16Hours continueously for 7 days. |
298 | Providing ICTP Main Switch 63 Amp with HRC fuses / Side handled operated Change over switch of L&T/Crompton/Standard/Havells make suitable capacity Operational rating as per IS: 4064 (Part - II) 1978 with up to date amendments immediately after the power meter of HPSEB |
299 | Providing M.S. sheet, steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm, duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories with all internal connections:- |
300 | M.C.B. 63 Amp. Havell/MDS/Standard of make of suitable capacity on incoming feeder with or without initial oil filling as the case may be withneutral linkedunder voltage releases as per IS: 2516 (Part - II) 1985 with up to date amendments with. |
301 | E.L.C.B of Havell/MDS/INDETEC make as per IS: 2516 (Part - II) 1985 with upto date amendmentwhich should have control box operating handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape etc. It should also be lifted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end. |
302 | The voltage monitor relay of L&T/AE make three phase with all protection and usual indicator and electric siren against single phasing low voltage, high voltage, reverse phasing, over loading and phase voltage difference as per IS: 1248 (Part - II ) 1983 (Latest edition). |
303 | 100mm square type A.C. supply voltmeter of AE/L&T Rishab make of suitable range with selector switches as per IS: 4064 (Part - II ) -1978 with up to date amendments. |
304 | Power factor meter of AE/L&T Rishab make as perIS: 1248 (Part - V ) 1983(Latest edition) with up to date amendments of suitable rating. |
305 | Frequency meter of AE/ L&T Rishab make as perIS: 1248 (Part - IV ) 1983( Latest edition) with up to date amendments of suitable rating. |
306 | Bus bar chamber with copper strips having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS: 8084-1976 and IS: 11354-1985 read with IS 5578-1985 with up to date amendments 63 Amp. |
307 | ICTP switches with HRC fuses ofL&T/ Standard/Havells make and of suitable capacity as per IS: 4064 (Part - II) -1978 with up to date amendments. 63 Amp. |
308 | Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 ( P-I & II) with up to date amendments. |
309 | 100mmSquare type AC supplyAmmeter of AE /L&T Rishab make of suitable range (0-60) with selector switches and CTS operated as per IS:1248 (P-II) 1983 with up to date amendments. |
310 | Capacitor of L&T make as per IS:2834 -1986 with up to date amendments toraise the power factor at site to 0.95 for direct connections to induction motor individuallyof 5 KVAr ratingaccordingto HP offered including cables as per relevant ISI code (of L&T/Finolex make) from bus bar chamber to capacitor and also including ICTP switches of appropriate rangeas per IS: 4064 (Part - II) 1978 withupto date amendments |
311 | Providing suitable Oil immersed Star Delta starter of M.E.I / Kilburn make as per IS:8544 (Part - II ) -1987 with up to date amendments for Squirrel Cage motor mounted on panel board with magnetic type overload release and dashpot time lag, under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS 1248 (P-V)-1983 with up to date amendments. |
312 | Providing Hour run meter of recommended make as per IS: 722 (Latest edition) |
313 | Providing double flanged Cast iron sluice valve of Kirloskar / Leader or JSV approved make for the suction pipe and capable of withstanding the normal seat pressure as per IS:14846-2000 with up to date amendments (Class PN-1.00, size equal to dia of suction pipe). |
314 | Providing double flanged Cast steel sluice valve of Kirloskar / Leader or JSV approved make and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS:1414/API-600(Class ASA-300 having size one step higher to delivery of pump) |
315 | Providing double flangedCast steel reflux valve of Kirloskar / Leader or JSV approved make and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS:1868/API-600 (Class ASA-300 having by pass arrangement and size one step higher to delivery of pump) |
316 | Providing double flangedCast steel 65 mm non return valve of Kirloskar / Leader or JSV approved make having bye pass arrangement for rising main and capable of with standing normal sseat pressure of 52 kg/cm2 as per BS:1868/API-600 (Class ASA-300). |
317 | Providing 100mm dia. circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 75 Kg/cm2 |
318 | Providing 100mm dia. vacume dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 760 mercury. |
319 | Installation of all the items appearing at Serial No. 161 to167.01 |
320 | Providing and fixing double flanged 80 mm piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the rising main respectively complete with all specials such as bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as indicated in the drawing No.2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS: 1364-1983. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated under item No.1. |
321 | The size of the various components to be as under:- |
322 | (i) Suction pipe 80 mm dia Min. length = 10 mtr. |
323 | (ii)Delivery pipe65 mm dia -do-= 6 mtr. |
324 | (iii) Common Header80 mm dia-do-= 6 mtr. |
325 | and will extend up to 5 meters from the outer wall of the pump house in the direction to be jointed. |
326 | Providing and laying copper PVC insulated armoured power cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of L&T/Finolex make including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor. |
327 | (i)Motor side:4mm2 Min length = 20 mtrs. |
328 | (ii)Supply side: 6 mm2Min. length =10 mtrs. |
329 | Providing and fixing double loop earthing and G.I. plate 600 mm x 600mm x 3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 32 mm x 3_mm G.I. strips & G.I. wire as per IS: 3043 -1987 withup to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect. |
330 | Centrifugal Pump (LWSS Gaddidhar( Bag) Second Stage (Sadhoti):- Supply & errection ofhorizontal spindle horizontal split casing/end suctions (back pull out arrangement) Single/double/multistage centrifugal pumps or combination of pumps in series/parellel of Mather & Platt/KSB/ Kirloskar or JSV approved make conforming to BIS 1520-1980) pump (Latest with up to date amendments, read with BIS: 9137-1978(latest edition)suitable for lifting clear/raw water of under mentioned characteristics with bronze/Suitable alloy, priming funnels, casing ring andshaftmotor of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on acommon MS/Cast steel plate (base platefrom the principal manufacturer of pumping set) to coupling 3 phase squirrel cage electric induction motor of standard make such as Kirloskar/ NGEF/Crompton or JSV approved make conforming to IS 12615-2018 and should be energy efficient minimum IE2 compliant and totally enclosed fan cooled (TEFC) type (latest with upto date ammendments) it should include the cost of bearings, nuts & bolts, painting etc. and shall be and suitable for operation on the date given below: |
331 | SITE CONDITIONS:- Total Head165.00 mtrs Discharge required3.50 LPS each set. No. of Pump required. 1.00 No set Length of R/main 600.00 mtrs. Dia of R/main32mm dia Location of the site of installation of machinery-The site is located at a distance of Km by road &KM on head load (for the installation of both machinery). The Altitude of :-The Altitude of place is1180 mtrs above MSL Type of Current:- AC three phase supply with Rate Voltage:-415+ Type of water and its Charactristics of water a) Ambient Temperature b) Turbidity NTU NTU c) Hardness260 Mg/Ltrs -- d) PH Value 7.5-- e)Total Solid Mg/Lts)PH Value-- No of working hours.16 Hours. Limit of Pump(-) 15% (+) 10% R. M.P. of PumpingRPM(or to be specified by the tenderer) Test run16Hours continueously for 7 days. |
332 | Providing ICTP Main Switch 63 Amp with HRC fuses / Side handled operated Change over switch of L&T/Crompton/Standard/Havells make suitable capacity Operational rating as per IS: 4064 (Part - II) 1978 with up to date amendments immediately after the power meter of HPSEB |
333 | Providing M.S. sheet, steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm, duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories with all internal connections:- |
334 | M.C.B. 63 Amp. Havell/MDS/Standard of make of suitable capacity on incoming feeder with or without initial oil filling as the case may be withneutral linkedunder voltage releases as per IS: 2516 (Part - II) 1985 with up to date amendments with. |
335 | E.L.C.B of Havell/MDS/INDETEC make as per IS: 2516 (Part - II) 1985 with upto date amendmentwhich should have control box operating handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape etc. It should also be lifted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end. |
336 | The voltage monitor relay of L&T/AE make three phase with all protection and usual indicator and electric siren against single phasing low voltage, high voltage, reverse phasing, over loading and phase voltage difference as per IS: 1248 (Part - II ) 1983 (Latest edition). |
337 | 100mm square type A.C. supply voltmeter of AE/L&T Rishab make of suitable range with selector switches as per IS: 4064 (Part - II ) -1978 with up to date amendments. |
338 | Power factor meter of AE/L&T Rishab make as perIS: 1248 (Part - V ) 1983(Latest edition) with up to date amendments of suitable rating. |
339 | Frequency meter of AE/ L&T Rishab make as perIS: 1248 (Part - IV ) 1983( Latest edition) with up to date amendments of suitable rating. |
340 | Bus bar chamber with copper strips having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS: 8084-1976 and IS: 11354-1985 read with IS 5578-1985 with up to date amendments 63 Amp. |
341 | ICTP switches with HRC fuses ofL&T/ Standard/Havells make and of suitable capacity as per IS: 4064 (Part - II) -1978 with up to date amendments. 63 Amp. |
342 | Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 ( P-I & II) with up to date amendments. |
343 | 100mmSquare type AC supplyAmmeter of AE /L&T Rishab make of suitable range (0-60) with selector switches and CTS operated as per IS:1248 (P-II) 1983 with up to date amendments. |
344 | Capacitor of L&T make as per IS:2834 -1986 with up to date amendments toraise the power factor at site to 0.95 for direct connections to induction motor individuallyof 5 KVAr ratingaccordingto HP offered including cables as per relevant ISI code (of L&T/Finolex make) from bus bar chamber to capacitor and also including ICTP switches of appropriate rangeas per IS: 4064 (Part - II) 1978 withupto date amendments |
345 | Providing suitable Oil immersed Star Delta starter of M.E.I / Kilburn make as per IS:8544 (Part - II ) -1987 with up to date amendments for Squirrel Cage motor mounted on panel board with magnetic type overload release and dashpot time lag, under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS 1248 (P-V)-1983 with up to date amendments. |
346 | Providing Hour run meter of recommended make as per IS: 722 (Latest edition) |
347 | Providing doubleflanged Cast iron sluice valve of Kirloskar / Leader or JSV approved make for the suction pipe and capable of withstanding the normal seat pressure as per IS: 14846-2000 with up to date amendments (Class PN-1.00, size equal to dia of suction pipe). |
348 | Providing double flanged Cast steel sluice valve of Kirloskar / Leader or JSV approved make and capable of with standing nominal seat pressure of 21 kg/cm2 as per BS:1414/API-600 (Class ASA-150 having size one step higher to delivery of pump). |
349 | Providing double flangedCast steel reflux valve of Kirloskar / Leader or JSV approved make and capable of with standing nominal seat pressure of 21 kg/cm2 as per BS:1868/API-600 (Class ASA-150 having by pass arrangement and size one step higher to delivery of pump). |
350 | Providing double flangedCast steel 32 mm non return valve of Kirloskar / Leader or JSV approved make having bye pass arrangement for rising main and capable of with standing normal seat pressure of 21 kg/cm2 as per BS:1868/API-600 (Class ASA-300 ) |
351 | Providing 100mm dia. circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 75 Kg/cm2 |
352 | Providing 100mm dia. vacume dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 760 mercury. |
353 | Installation of all the items appearing at Serial No. 174 to 180.01 |
354 | Providing and fixing double flanged 40 mm piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the rising main respectively complete with all specials such as bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as indicated in the drawing No.2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS: 1364-1983. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated under item No.1. |
355 | The size of the various components to be as under:- |
356 | (i) Suction pipe40 mm dia Min. length = 10 mtr. |
357 | (ii)Delivery pipe32 mm dia -do-= 6 mtr. |
358 | (iii) Common Header 40 mm dia-do-= 6 mtr. |
359 | and will extend up to 5 meters from the outer wall of the pump house in the direction to be jointed. |
360 | Providing and laying copper PVC insulated armoured power cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of L&T/Finolex make including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor. |
361 | (i)Motor side:4mm2 Min length = 20 mtrs. |
362 | (ii)Supply side: 6 mm2Min. length =10 mtrs. |
363 | Providing and fixing double loop earthing and G.I. plate 600 mm x 600mm x 3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 32 mm x 3_mm G.I. strips & G.I. wire as per IS: 3043 -1987 withup to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect. |
364 | Centrifugal Pump (LWSS Gaddidhar( Bammi Nallah) Ph-2):- Supply & errection ofhorizontal spindle horizontal split casing/end suctions (back pull out arrangement) Single /double /multistage centrifugal pumps or combination of pumps in series/parellel of Mather & Platt/KSB/ Kirloskar or JSV approved make conforming to BIS 1520-1980) pump (Latest with up to date amendments, read with BIS: 9137-1978(latest edition)suitable for lifting clear/raw water of under mentioned characteristics with bronze/Suitable alloy, priming funnels, casing ring andshaftmotor of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on acommon MS/Cast steel plate (base platefrom the principal manufacturer of pumping set) to coupling 3 phase squirrel cage electric induction motor of standard make such as Kirloskar/ NGEF/Crompton or JSV approved make conforming to IS 12615-2018 and should be energy efficient minimum IE2 compliant and totally enclosed fan cooled (TEFC) type (latest with upto date ammendments) it should include the cost of bearings, nuts & bolts, painting etc. and shall be and suitable for operation on the date given below: |
365 | SITE CONDITIONS:- Total Head390.00 mtrs Discharge required5.00 LPS each set. No. of Pump required. 1.00 No setLength of R/main 1170.00 mtrs. Dia of R/main65mm dia Location of the site of installation of machinery-The site is located at a distance of Km by road &KM on head load (for the installation of both machinery). Head Load (for the installation of both machinery). The Altitude of :-The Altitude of place is1050 mtrs above MSL Type of Current:- AC three phase supply with Rate Voltage:-415+ Type of water and its Charactristics of water a) Ambient Temperature b) Turbidity NTU NTU c) Hardness260 Mg/Ltrs -- d) PH Value 7.5-- e)Total Solid Mg/Lts)PH Value-- No of working hours.16 Hours. Limit of Pump(-) 15% (+) 10% R. M.P. of PumpingRPM(or to be specified by the tenderer) Test run16Hours continueously for 7 days. |
366 | Providing ICTP Main Switch 63 Amp with HRC fuses / Side handled operated Change over switch of L&T/Crompton/Standard/Havells make suitable capacity Operational rating as per IS: 4064 (Part - II) 1978 with up to date amendments immediately after the power meter of HPSEB |
367 | Providing M.S. sheet, steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm, duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories with all internal connections:- |
368 | M.C.B. 63 Amp. Havell/MDS/Standard of make of suitable capacity on incoming feeder with or without initial oil filling as the case may be withneutral linkedunder voltage releases as per IS: 2516 (Part - II) 1985 with up to date amendments with. |
369 | E.L.C.B of Havell/MDS/INDETEC make as per IS: 2516 (Part - II) 1985 with upto date amendmentwhich should have control box operating handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape etc. It should also be lifted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end. |
370 | The voltage monitor relay of L&T/AE make three phase with all protection and usual indicator and electric siren against single phasing low voltage, high voltage, reverse phasing, over loading and phase voltage difference as per IS: 1248 (Part - II ) 1983 (Latest edition). |
371 | 100mm square type A.C. supply voltmeter of AE/L&T Rishab make of suitable range with selector switches as per IS: 4064 (Part - II ) -1978 with up to date amendments. |
372 | Power factor meter of AE/L&T Rishab make as perIS: 1248 (Part - V ) 1983(Latest edition) with up to date amendments of suitable rating. |
373 | Frequency meter of AE/ L&T Rishab make as perIS: 1248 (Part - IV ) 1983( Latest edition) with up to date amendments of suitable rating. |
374 | Bus bar chamber with copper strips having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS: 8084-1976 and IS: 11354-1985 read with IS 5578-1985 with up to date amendments 63 Amp. |
375 | ICTP switches with HRC fuses ofL&T/ Standard/Havells make and of suitable capacity as per IS: 4064 (Part - II) -1978 with up to date amendments. 63 Amp. |
376 | Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 ( P-I & II) with up to date amendments. |
377 | 100mmSquare type AC supplyAmmeter of AE /L&T Rishab make of suitable range (0-60) with selector switches and CTS operated as per IS:1248 (P-II) 1983 with up to date amendments. |
378 | Capacitor of L&T make as per IS:2834 -1986 with up to date amendments toraise the power factor at site to 0.95 for direct connections to induction motor individuallyof 5 KVAr ratingaccordingto HP offered including cables as per relevant ISI code (of L&T/Finolex make) from bus bar chamber to capacitor and also including ICTP switches of appropriate rangeas per IS: 4064 (Part - II) 1978 withupto date amendments |
379 | Providing suitable Oil immersed Star Delta starter of M.E.I / Kilburn make as per IS:8544 (Part - II ) -1987 with up to date amendments for Squirrel Cage motor mounted on panel board with magnetic type overload release and dashpot time lag, under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS 1248 (P-V)-1983 with up to date amendments. |
380 | Providing Hour run meter of recommended make as per IS: 722 (Latest edition) |
381 | Providing doubleflanged Cast iron sluice valve of Kirloskar / Leader or JSV approved make for the suction pipe and capable of withstanding the normal seat pressure as per IS: 14846-2000 with up to date amendments (Class PN-1.00, size equal to dia of suction pipe). |
382 | Providing double flanged Cast steel sluice valve of Kirloskar / Leader or JSV approved make and capable of with standing nominal seat pressure of 21 kg/cm2 as per BS:1414/API-600 (Class ASA-150 having size one step higher to delivery of pump). |
383 | Providing double flangedCast steel reflux valve of Kirloskar / Leader or JSV approved make and capable of with standing nominal seat pressure of 21 kg/cm2 as per BS:1868/API-600 (Class ASA-150 having by pass arrangement and size one step higher to delivery of pump). |
384 | Providing double flangedCast steel 32 mm non return valve of Kirloskar / Leader or JSV approved make having bye pass arrangement for rising main and capable of with standing normal seat pressure of 21 kg/cm2 as per BS:1868/API-600 (Class ASA-300 ) |
385 | Providing 100mm dia. circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 75 Kg/cm2 |
386 | Providing 100mm dia. vacume dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 760 mercury. |
387 | Installation of all the items appearing at Serial No. 174 to 180.01 |
388 | Providing and fixing double flanged 40 mm piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the rising main respectively complete with all specials such as bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as indicated in the drawing No.2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS: 1364-1983. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated under item No.1. |
389 | The size of the various components to be as under:- |
390 | (i) Suction pipe40 mm dia Min. length = 10 mtr. |
391 | (ii)Delivery pipe32 mm dia -do-= 6 mtr. |
392 | (iii) Common Header 40 mm dia-do-= 6 mtr. |
393 | and will extend up to 5 meters from the outer wall of the pump house in the direction to be jointed. |
394 | Providing and laying copper PVC insulated armoured power cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of L&T/Finolex make including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor. |
395 | (i)Motor side:4mm2 Min length = 20 mtrs. |
396 | (ii)Supply side: 6 mm2Min. length =10 mtrs. |
397 | Providing and fixing double loop earthing and G.I. plate 600 mm x 600mm x 3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 32 mm x 3_mm G.I. strips & G.I. wire as per IS: 3043 -1987 withup to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect. |
398 | Centrifugal Pump (LWSS Gaddidhar( Bammi Nallah) Ph-2):- Supply & errection ofhorizontal spindle horizontal split casing/end suctions (back pull out arrangement) Single /double /multistage centrifugal pumps or combination of pumps in series/parellel of Mather & Platt/KSB/ Kirloskar or JSV approved make conforming to BIS 1520-1980) pump (Latest with up to date amendments, read with BIS: 9137-1978(latest edition)suitable for lifting clear/raw water of under mentioned characteristics with bronze/Suitable alloy, priming funnels, casing ring andshaftmotor of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on acommon MS/Cast steel plate (base platefrom the principal manufacturer of pumping set) to coupling 3 phase squirrel cage electric induction motor of standard make such as Kirloskar/ NGEF/Crompton or JSV approved make conforming to IS 12615-2018 and should be energy efficient minimum IE2 compliant and totally enclosed fan cooled (TEFC) type (latest with upto date ammendments) it should include the cost of bearings, nuts & bolts, painting etc. and shall be and suitable for operation on the date given below: |
399 | SITE CONDITIONS:- Total Head432.00 mtrs Discharge required6.50 LPS each set. No. of Pump required. 1.00 Nos setsLength of R/main 3050 mtrs. Dia of R/main125mm dia Location of the site of installation of machinery-The site is located at a distance of Km by road &KM on head load (for the installation of both machinery). Head Load (for the installation of both machinery). The Altitude of :-The Altitude of place is942 mtrs above MSL Type of Current:- AC three phase supply with Rate Voltage:-415+ Type of water and its Charactristics of water a) Ambient Temperature b) Turbidity NTU NTU c) Hardness260 Mg/Ltrs -- d) PH Value 7.5-- e)Total Solid Mg/Lts)PH Value-- No of working hours.16 Hours. Limit of Pump(-) 15% (+) 10% R. M.P. of PumpingRPM(or to be specified by the tenderer) Test run16Hours continueously for 7 days. |
400 | Providing ICTP Main Switch 250 Amp with HRC fuses / Side handled operated Change over switch of L&T/Crompton/Standard/Havells make suitable capacity Operational rating as per IS: 4064 (Part - II) 1978 with up to date amendments immediately after the power meter of HPSEB |
401 | Providing M.S. sheet, steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm, duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories with all internal connections:- |
402 | O.C.B. 200 Amp. Havell/MDS/Standard of make of suitable capacity on incoming feeder with or without initial oil filling as the case may be withneutral linkedunder voltage releases as per IS: 2516 (Part - II) 1985 with up to date amendments with. |
403 | E.L.R. of Havell/MDS/INDETEC make as per IS: 2516 (Part - II) 1985 with upto date amendmentwhich should have control box operating handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape etc. It should also be lifted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end. |
404 | The voltage monitor relay of L&T/AE make three phase with all protection and usual indicator and electric siren against single phasing low voltage, high voltage, reverse phasing, over loading and phase voltage difference as per IS: 1248 (Part - II ) 1983 (Latest edition). |
405 | 100mm square type A.C. supply voltmeter of AE/L&T Rishab make of suitable range with selector switches as per IS: 4064 (Part - II ) -1978 with up to date amendments. |
406 | Power factor meter of AE/L&T Rishab make as perIS: 1248 (Part - V ) 1983(Latest edition) with up to date amendments of suitable rating. |
407 | Frequency meter of AE/ L&T Rishab make as perIS: 1248 (Part - IV ) 1983( Latest edition) with up to date amendments of suitable rating. |
408 | Bus bar chamber with copper strips having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS: 8084-1976 and IS: 11354-1985 read with IS 5578-1985 with up to date amendments 250 Amp. |
409 | ICTP switches with HRC fuses ofL&T/ Standard/Havells make and of suitable capacity as per IS: 4064 (Part - II) -1978 with up to date amendments. 250 Amp. |
410 | Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 ( P-I & II) with up to date amendments. |
411 | 100mmSquare type AC supplyAmmeter of AE /L&T Rishab make of suitable range (0-200) with selector switches and CTS operated as per IS:1248 (P-II) 1983 with up to date amendments. |
412 | Capacitor of L&T make as per IS:2834 -1986 with up to date amendments toraise the power factor at site to 0.95 for direct connections to induction motor individuallyof 21 KVAr ratingaccordingto HP offered including cables as per relevant ISI code (of L&T/Finolex make) from bus bar chamber to capacitor and also including ICTP switches of appropriate rangeas per IS: 4064 (Part - II) 1978 withupto date amendments |
413 | Providing suitable Auto Trasformer starter of M.E.I / Kilburn.make as per IS:8544 (Part - IV ) -1987 with up to date amendments for Squirrel Cage motor mounted on panel board with magnetic type overload release and dashpot time lag, under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS 1248 (P-V)-1983 with up to date amendments. |
414 | Providing Hour run meter of recommended make as per IS: 722 (Latest edition) |
415 | Providing doubleflanged Cast iron sluice valve of Kirloskar / Leader or JSV approved make for the suction pipe and capable of withstanding the normal seat pressure as per IS: 14846-2000 with up to date amendments (Class PN-1.00, size equal to dia of suction pipe). |
416 | Providing double flangedCast steel sluice valve of Kirloskar / Leader or JSV approved make and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS:1414/API-600 (Class ASA-300 having size one step higher to delivery of pump). |
417 | Providing double flanged Cast steel reflux valve of Kirloskar / Leader or JSV approved make and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS:1868/API-600 (Class ASA-300 having by pass arrangement and size one step higher to delivery of pump). |
418 | Providing double flangedCast steel 125 mm non return valve of Kirloskar / Leader or JSV approved make having bye pass arrangement for rising main and capable of with standing normal seat pressure of 52 kg/cm2 as per BS:1868/API-600 (Class ASA-300). |
419 | Providing 100mm dia. circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 75 Kg/cm2 |
420 | Providing 100mm dia. vacume dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 760 mercury. |
421 | Installation of all the items appearing at Serial No. 200 to206.01 |
422 | Providing and fixing double flanged 150 mm piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the rising main respectively complete with all specials such as bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as indicated in the drawing No.2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS: 1364-1983. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated under item No.1. |
423 | The size of the various components to be as under:- |
424 | (i) Suction pipe150 mm dia Min. length = 10 mtr. |
425 | (ii)Delivery pipe 125 mm dia -do-= 6 mtr. |
426 | (iii) Common Header150 mm dia-do-= 6 mtr. |
427 | and will extend up to 5 meters from the outer wall of the pump house in the direction to be jointed. |
428 | Providing and laying copper PVC insulated armoured power cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of L&T/Finolex make including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor. |
429 | (i)Motor side:50mm2 Min length = 20 mtrs. |
430 | (ii)Supply side: 70 mm2Min. length =10 mtrs. |
431 | Providing and fixing double loop earthing and G.I. plate 600 mm x 600mm x 3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 32 mm x 3_mm G.I. strips & G.I. wire as per IS: 3043 -1987 withup to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect. |
432 | Centrifugal Pump (LWSS Beri Kamlah Gadhidhar Second Stage):- Supply & errection ofhorizontal spindle horizontal split casing/end suctions (back pull out arrangement) Single/double/multistage centrifugal pumps or combination of pumps in series/parellel of Mather & Platt/KSB/ Kirloskar or JSV approved make conforming to BIS 1520-1980) pump (Latest with up to date amendments, read with BIS: 9137-1978(latest edition)suitable for lifting clear/raw water of under mentioned characteristics with bronze/Suitable alloy, priming funnels, casing ring andshaftmotor of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on acommon MS/Cast steel plate (base platefrom the principal manufacturer of pumping set) to coupling 3 phase squirrel cage electric induction motor of standard make such as Kirloskar/ NGEF/Crompton or JSV approved make conforming to IS 12615-2018 and should be energy efficient minimum IE2 compliant and totally enclosed fan cooled (TEFC) type (latest with upto date ammendments) it should include the cost of bearings, nuts & bolts, painting etc. and shall be and suitable for operation on the date given below: |
433 | SITE CONDITIONS:- Total Head295.00 mtrs Discharge required8.19 LPS each set. No. of Pump required. 1.00 Nos sets Length of R/main 4000.00 mtrs. Dia of R/main125mm dia Location of the site of installation of machinery-The site is located at a distance of Km by road &KM on head load (for the installation of both machinery). The Altitude of :-The Altitude of place is1380 mtrs above MSL Type of Current:- AC three phase supply with Rate Voltage:-415+ Type of water and its Charactristics of water a) Ambient Temperature b) Turbidity NTU NTU c) Hardness260 Mg/Ltrs -- d) PH Value 7.5-- e)Total Solid Mg/Lts)PH Value-- No of working hours.16 Hours. Limit of Pump(-) 15% (+) 10% R. M.P. of PumpingRPM(or to be specified by the tenderer) Test run16Hours continueously for 7 days. |
434 | Providing ICTP Main Switch 250 Amp with HRC fuses / Side handled operated Change over switch of L&T/Crompton/Standard/Havells make suitable capacity Operational rating as per IS: 4064 (Part - II) 1978 with up to date amendments immediately after the power meter of HPSEB |
435 | Providing M.S. sheet, steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm, duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories with all internal connections:- |
436 | O.C.B. 200 Amp. Havell/MDS/Standard of make of suitable capacity on incoming feeder with or without initial oil filling as the case may be withneutral linkedunder voltage releases as per IS: 2516 (Part - II) 1985 with up to date amendments with. |
437 | E.L.R. of Havell/MDS/INDETEC make as per IS: 2516 (Part - II) 1985 with upto date amendmentwhich should have control box operating handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape etc. It should also be lifted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end. |
438 | The voltage monitor relay of L&T/AE make three phase with all protection and usual indicator and electric siren against single phasing low voltage, high voltage, reverse phasing, over loading and phase voltage difference as per IS: 1248 (Part - II ) 1983 (Latest edition). |
439 | 100mm square type A.C. supply voltmeter of AE/L&T Rishab make of suitable range with selector switches as per IS: 4064 (Part - II ) -1978 with up to date amendments. |
440 | Power factor meter of AE/L&T Rishab make as perIS: 1248 (Part - V ) 1983(Latest edition) with up to date amendments of suitable rating. |
441 | Frequency meter of AE/ L&T Rishab make as perIS: 1248 (Part - IV ) 1983( Latest edition) with up to date amendments of suitable rating. |
442 | Bus bar chamber with copper strips having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS: 8084-1976 and IS: 11354-1985 read with IS 5578-1985 with up to date amendments 250 Amp. |
443 | ICTP switches with HRC fuses ofL&T/ Standard/Havells make and of suitable capacity as per IS: 4064 (Part - II) -1978 with up to date amendments. 250 Amp. |
444 | Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 ( P-I & II) with up to date amendments. |
445 | 100mmSquare type AC supplyAmmeter of AE /L&T Rishab make of suitable range (0-200) with selector switches and CTS operated as per IS:1248 (P-II) 1983 with up to date amendments. |
446 | Capacitor of L&T make as per IS:2834 -1986 with up to date amendments toraise the power factor at site to 0.95 for direct connections to induction motor individuallyof 21 KVAr ratingaccordingto HP offered including cables as per relevant ISI code (of L&T/Finolex make) from bus bar chamber to capacitor and also including ICTP switches of appropriate rangeas per IS: 4064 (Part - II) 1978 withupto date amendments |
447 | Providing suitable Auto Trasformer starter of M.E.I / Kilburn.make as per IS:8544 (Part - IV ) -1987 with up to date amendments for Squirrel Cage motor mounted on panel board with magnetic type overload release and dashpot time lag, under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS 1248 (P-V)-1983 with up to date amendments. |
448 | Providing Hour run meter of recommended make as per IS: 722 (Latest edition) |
449 | Providing doubleflanged Cast iron sluice valve of Kirloskar / Leader or JSV approved make for the suction pipe and capable of withstanding the normal seat pressure as per IS: 14846-2000 with up to date amendments (Class PN-1.00, size equal to dia of suction pipe). |
450 | Providing double flangedCast steel sluice valve of Kirloskar / Leader or JSV approved make and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS:1414/API-600 (Class ASA-300 having size one step higher to delivery of pump). |
451 | Providing double flanged Cast steel reflux valve of Kirloskar / Leader or JSV approved make and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS:1868/API-600 (Class ASA-300 having by pass arrangement and size one step higher to delivery of pump). |
452 | Providing double flangedCast steel 125 mm non return valve of Kirloskar / Leader or JSV approved make having bye pass arrangement for rising main and capable of with standing normal seat pressure of 52 kg/cm2 as per BS:1868/API-600 (Class ASA-300) |
453 | Providing 100mm dia. circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 75 Kg/cm2 |
454 | Providing 100mm dia. vacume dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 760 mercury. |
455 | Installation of all the items appearing at Serial No. 213 to219.01 |
456 | Providing and fixing double flanged 150 mm piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the rising main respectively complete with all specials such as bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as indicated in the drawing No.2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS: 1364-1983. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated under item No.1. |
457 | The size of the various components to be as under:- |
458 | (i) Suction pipe 150 mm dia Min. length = 10 mtr. |
459 | (ii)Delivery pipe125 mm dia -do-= 6 mtr. |
460 | (iii) Common Header 150 mm dia-do-= 6 mtr. |
461 | and will extend up to 5 meters from the outer wall of the pump house in the direction to be jointed. |
462 | Providing and laying copper PVC insulated armoured power cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of L&T/Finolex make including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor. |
463 | (i)Motor side:50mm2 Min length = 20 mtrs. |
464 | (ii)Supply side: 70 mm2Min. length =10 mtrs. |
465 | Providing and fixing double loop earthing and G.I. plate 600 mm x 600mm x 3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 32 mm x 3_mm G.I. strips & G.I. wire as per IS: 3043 -1987 withup to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect. |
466 | Centrifugal Pump (LWSS Kothuwan Dhalara):- Supply & errection ofhorizontal spindle horizontal split casing/end suctions (back pull out arrangement) Single/double/multistage centrifugal pumps or combination of pumps in series/parellel of Mather & Platt/KSB/ Kirloskar or JSV approved make conforming to BIS 1520-1980) pump (Latest with up to date amendments, read with BIS: 9137-1978(latest edition)suitable for lifting clear/raw water of under mentioned characteristics with bronze/Suitable alloy, priming funnels, casing ring andshaftmotor of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on acommon MS/Cast steel plate (base platefrom the principal manufacturer of pumping set) to coupling 3 phase squirrel cage electric induction motor of standard make such as Kirloskar/ NGEF/Crompton or JSV approved make conforming to IS 12615-2018 and should be energy efficient minimum IE2 compliant and totally enclosed fan cooled (TEFC) type (latest with upto date ammendments) it should include the cost of bearings, nuts & bolts, painting etc. and shall be and suitable for operation on the date given below: |
467 | SITE CONDITIONS:- Total Head354.00 mtrs Discharge required9.40 LPS each set. No. of Pump required. 1.00 Nos sets Length of R/main 1310 mtrs. Dia of R/main125mm dia Location of the site of installation of machinery-The site is located at a distance of Km by road &KM on head load (for the installation of both machinery) .The Altitude of :-The Altitude of place is1029 mtrs above MSL Type of Current:- AC three phase supply with Rate Voltage:-415+ Type of water and its Charactristics of water a) Ambient Temperature b) Turbidity NTU NTU c) Hardness260 Mg/Ltrs -- d) PH Value 7.5-- e)Total Solid Mg/Lts) PH Value-- No of working hours.16 Hours. Limit of Pump(-) 15% (+) 10% R. M.P. of PumpingRPM(or to be specified by the tenderer) Test run16Hours continueously for 7 days. |
468 | Providing ICTP Main Switch 250 Amp with HRC fuses / Side handled operated Change over switch of L&T/Crompton/Standard/Havells make suitable capacity Operational rating as per IS: 4064 (Part - II) 1978 with up to date amendments immediately after the power meter of HPSEB |
469 | Providing M.S. sheet, steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm, duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories with all internal connections:- |
470 | O.C.B. 200 Amp. Havell/MDS/Standard of make of suitable capacity on incoming feeder with or without initial oil filling as the case may be withneutral linkedunder voltage releases as per IS: 2516 (Part - II) 1985 with up to date amendments with. |
471 | E.L.R. of Havell/MDS/INDETEC make as per IS: 2516 (Part - II) 1985 with upto date amendmentwhich should have control box operating handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape etc. It should also be lifted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end. |
472 | The voltage monitor relay of L&T/AE make three phase with all protection and usual indicator and electric siren against single phasing low voltage, high voltage, reverse phasing, over loading and phase voltage difference as per IS: 1248 (Part - II ) 1983 (Latest edition). |
473 | 100mm square type A.C. supply voltmeter of AE/L&T Rishab make of suitable range with selector switches as per IS: 4064 (Part - II ) -1978 with up to date amendments. |
474 | Power factor meter of AE/L&T Rishab make as perIS: 1248 (Part - V ) 1983(Latest edition) with up to date amendments of suitable rating. |
475 | Frequency meter of AE/ L&T Rishab make as perIS: 1248 (Part - IV ) 1983( Latest edition) with up to date amendments of suitable rating. |
476 | Bus bar chamber with copper strips having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS: 8084-1976 and IS: 11354-1985 read with IS 5578-1985 with up to date amendments 250 Amp. |
477 | ICTP switches with HRC fuses ofL&T/ Standard/Havells make and of suitable capacity as per IS: 4064 (Part - II) -1978 with up to date amendments. 250 Amp. |
478 | Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 ( P-I & II) with up to date amendments. |
479 | 100mmSquare type AC supplyAmmeter of AE /L&T Rishab make of suitable range (0-200) with selector switches and CTS operated as per IS:1248 (P-II) 1983 with up to date amendments. |
480 | Capacitor of L&T make as per IS:2834 -1986 with up to date amendments toraise the power factor at site to 0.95 for direct connections to induction motor individuallyof 21 KVAr ratingaccordingto HP offered including cables as per relevant ISI code (of L&T/Finolex make) from bus bar chamber to capacitor and also including ICTP switches of appropriate rangeas per IS: 4064 (Part - II) 1978 withupto date amendments |
481 | Providing suitable Auto Trasformer starter of M.E.I / Kilburn.make as per IS:8544 (Part - IV ) -1987 with up to date amendments for Squirrel Cage motor mounted on panel board with magnetic type overload release and dashpot time lag, under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS 1248 (P-V)-1983 with up to date amendments. |
482 | Providing Hour run meter of recommended make as per IS: 722 (Latest edition) |
483 | Providing doubleflanged Cast iron sluice valve of Kirloskar / Leader or JSV approved make for the suction pipe and capable of withstanding the normal seat pressure as per IS: 14846-2000 with up to date amendments (Class PN-1.00, size equal to dia of suction pipe). |
484 | Providing double flangedCast steel sluice valve of Kirloskar / Leader or JSV approved make and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS:1414/API-600 (Class ASA-300 having size one step higher to delivery of pump). |
485 | Providing double flanged Cast steel reflux valve of Kirloskar / Leader or JSV approved make and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS:1868/API-600 (Class ASA-300 having by pass arrangement and size one step higher to delivery of pump). |
486 | Providing double flangedCast steel 125 mm non return valve of Kirloskar / Leader/KSB /Bhel/Gled/Kilburn/Fouress/Bir (Air Valves)/Kartar/Pelican/Zoloto make having bye pass arrangement for rising main and capable of with standing normal sseat pressure of 52 kg/cm2 as per BS:1868/API-600 (Class ASA-300) |
487 | Providing 100mm dia. circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 75 Kg/cm2 |
488 | Providing 100mm dia. vacume dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 760 mercury. |
489 | Installation of all the items appearing at Serial No. 226 to232.01 |
490 | Providing and fixing double flanged 150 mm piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the rising main respectively complete with all specials such as bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as indicated in the drawing No.2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS: 1364-1983. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated under item No.1. |
491 | The size of the various components to be as under:- |
492 | (i) Suction pipe 150 mm dia Min. length = 10 mtr. |
493 | (ii)Delivery pipe 125 mm dia -do-= 6 mtr. |
494 | (iii) Common Header 150 mm dia-do-= 6 mtr. |
495 | and will extend up to 5 meters from the outer wall of the pump house in the direction to be jointed. |
496 | Providing and laying copper PVC insulated armoured power cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of L&T/Finolex make including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor. |
497 | (i)Motor side:50mm2 Min length = 20 mtrs. |
498 | (ii)Supply side: 70 mm2Min. length =10 mtrs. |
499 | Providing and fixing double loop earthing and G.I. plate 600 mm x 600mm x 3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 32 mm x 3_mm G.I. strips & G.I. wire as per IS: 3043 -1987 withup to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect. |
500 | Centrifugal Pump (LWSS Beri Kaltri):- Supply & errection ofhorizontal spindle horizontal split casing/end suctions (back pull out arrangement) Single/double/multistage centrifugal pumps or combination of pumps in series/parellel of Mather & Platt/KSB/ Kirloskar or JSV approved make conforming to BIS 1520-1980) pump (Latest with up to date amendments, read with BIS: 9137-1978(latest edition)suitable for lifting clear/raw water of under mentioned characteristics with bronze/Suitable alloy, priming funnels, casing ring andshaftmotor of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on acommon MS/Cast steel plate (base platefrom the principal manufacturer of pumping set) to coupling 3 phase squirrel cage electric induction motor of standard make such as Kirloskar/ NGEF/Crompton or JSV approved make conforming to IS 12615-2018 and should be energy efficient minimum IE2 compliant and totally enclosed fan cooled (TEFC) type (latest with upto date ammendments) it should include the cost of bearings, nuts & bolts, painting etc. and shall be and suitable for operation on the date given below: |
501 | SITE CONDITIONS:- Total Head375.00 mtrs Discharge required3.00 LPS each set. No. of Pump required. 1.00 Nos sets Length of R/main 1310.00 mtrs. Dia of R/main80mm dia Location of the site of installation of machinery-The site is located at a distance of Km by road &KM on head load (for the installation of both machinery). Head Load (for the installation of both machinery). The Altitude of :-The Altitude of place is862 mtrs above MSL Type of Current:- AC three phase supply with Rate Voltage:-415+ Type of water and its Charactristics of water a) Ambient Temperature b) Turbidity NTU NTU c) Hardness260 Mg/Ltrs -- d) PH Value 7.5-- e)Total Solid Mg/Lts)PH Value-- No of working hours.16 Hours. Limit of Pump(-) 15% (+) 10% R. M.P. of PumpingRPM(or to be specified by the tenderer) Test run16Hours continueously for 7 days. |
502 | Providing ICTP Main Switch 125 Amp with HRC fuses / Side handled operated Change over switch of L&T/Crompton/Standard/Havells make suitable capacity Operational rating as per IS: 4064 (Part - II) 1978 with up to date amendments immediately after the power meter of HPSEB |
503 | Providing M.S. sheet, steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm, duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories with all internal connections:- |
504 | M.C.B. 125 Amp. Havell/MDS/Standard of make of suitable capacity on incoming feeder with or without initial oil filling as the case may be withneutral linkedunder voltage releases as per IS: 2516 (Part - II) 1985 with up to date amendments with. |
505 | E.L.R. of Havell/MDS/INDETEC make as per IS: 2516 (Part - II) 1985 with upto date amendmentwhich should have control box operating handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape etc. It should also be lifted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end. |
506 | The voltage monitor relay of L&T/AE make three phase with all protection and usual indicator and electric siren against single phasing low voltage, high voltage, reverse phasing, over loading and phase voltage difference as per IS: 1248 (Part - II ) 1983 (Latest edition). |
507 | 100mm square type A.C. supply voltmeter of AE/L&T Rishab make of suitable range with selector switches as per IS: 4064 (Part - II ) -1978 with up to date amendments. |
508 | Power factor meter of AE/L&T Rishab make as perIS: 1248 (Part - V ) 1983(Latest edition) with up to date amendments of suitable rating. |
509 | Frequency meter of AE/ L&T Rishab make as perIS: 1248 (Part - IV ) 1983( Latest edition) with up to date amendments of suitable rating. |
510 | Bus bar chamber with copper strips having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS: 8084-1976 and IS: 11354-1985 read with IS 5578-1985 with up to date amendments 125 Amp. |
511 | ICTP switches with HRC fuses ofL&T/ Standard/Havells make and of suitable capacity as per IS: 4064 (Part - II) -1978 with up to date amendments. 125 Amp. |
512 | Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 ( P-I & II) with up to date amendments. |
513 | 100mmSquare type AC supplyAmmeter of AE /L&T Rishab make of suitable range (0-200) with selector switches and CTS operated as per IS:1248 (P-II) 1983 with up to date amendments. |
514 | Capacitor of L&T make as per IS:2834 -1986 with up to date amendments toraise the power factor at site to 0.95 for direct connections to induction motor individuallyof 11 KVAr ratingaccordingto HP offered including cables as per relevant ISI code (of L&T/Finolex make) from bus bar chamber to capacitor and also including ICTP switches of appropriate rangeas per IS: 4064 (Part - II) 1978 withupto date amendments |
515 | Providing suitable Oil immersed Star Delta starter of M.E.I / Kilburn make as per IS:8544 (Part - II ) -1987 with up to date amendments for Squirrel Cage motor mounted on panel board with magnetic type overload release and dashpot time lag, under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS 1248 (P-V)-1983 with up to date amendments. |
516 | Providing Hour run meter of recommended make as per IS: 722 (Latest edition) |
517 | Providing doubleflanged Cast iron sluice valve of Kirloskar / Leader or JSV approved make for the suction pipe and capable of withstanding the normal seat pressure as per IS: 14846-2000 with up to date amendments (Class PN-1.00, size equal to dia of suction pipe). |
518 | Providing double flangedCast steel sluice valve of Kirloskar / Leader or JSV approved make and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS:1414/API-600 (Class ASA-300 having size one step higher to delivery of pump). |
519 | Providing double flanged Cast steel reflux valve of Kirloskar / Leader or JSV approved make and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS:1868/API-600 (Class ASA-300 having by pass arrangement and size one step higher to delivery of pump). |
520 | Providing double flangedCast steel 80 mm non return valve of Kirloskar / Leader or JSV approved make having bye pass arrangement for rising main and capable of with standing normal sseat pressure of 52 kg/cm2 as per BS:1868/API-600 (Class ASA-300) |
521 | Providing 100mm dia. circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 75 Kg/cm2 |
522 | Providing 100mm dia. vacume dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 760 mercury. |
523 | Installation of all the items appearing at Serial No. 239 to245.01 |
524 | Providing and fixing double flanged 100 mm piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the rising main respectively complete with all specials such as bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as indicated in the drawing No.2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS: 1364-1983. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated under item No.1. |
525 | The size of the various components to be as under:- |
526 | (i) Suction pipe100 mm dia Min. length = 10 mtr. |
527 | (ii)Delivery pipe 80 mm dia -do-= 6 mtr. |
528 | (iii) Common Header100 mm dia-do-= 6 mtr. |
529 | and will extend up to 5 meters from the outer wall of the pump house in the direction to be jointed. |
530 | Providing and laying copper PVC insulated armoured power cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of L&T/finolex make including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor. |
531 | (i)Motor side:16mm2 Min length = 20 mtrs. |
532 | (ii)Supply side: 25 mm2Min. length =10 mtrs. |
533 | Providing and fixing double loop earthing and G.I. plate 600 mm x 600mm x 3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 32 mm x 3_mm G.I. strips & G.I. wire as per IS: 3043 -1987 withup to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect. |
534 | Centrifugal Pump (LWSS Dhalara From Kothuwan Old):- Supply & errection ofhorizontal spindle horizontal split casing/end suctions (back pull out arrangement) Single /double /multistage centrifugal pumps or combination of pumps in series/parellel of Mather & Platt/KSB/ Kirloskar or JSV approved make conforming to BIS 1520-1980) pump (Latest with up to date amendments, read with BIS: 9137-1978(latest edition)suitable for lifting clear/raw water of under mentioned characteristics with bronze/Suitable alloy, priming funnels, casing ring andshaftmotor of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on acommon MS/Cast steel plate (base platefrom the principal manufacturer of pumping set) to coupling 3 phase squirrel cage electric induction motor of standard make such as Kirloskar/ NGEF/Crompton or JSV approved make conforming to IS 12615-2018 and should be energy efficient minimum IE2 compliant and totally enclosed fan cooled (TEFC) type (latest with upto date ammendments) it should include the cost of bearings, nuts & bolts, painting etc. and shall be and suitable for operation on the date given below: |
535 | SITE CONDITIONS:- Total Head265.00 mtrs Discharge required3.00 LPS each set. No. of Pump required. 1.00 Nos sets Length of R/main 2500.00 mtrs. Dia of R/main80mm dia Location of the site of installation of machinery-The site is located at a distance of Km by road &KM on head load (for the installation of both machinery). The Altitude of :-The Altitude of place is940 mtrs above MSL Type of Current:- AC three phase supply with Rate Voltage:-415+ Type of water and its Charactristics of water a) Ambient Temperature b) Turbidity NTU NTU c) Hardness260 Mg/Ltrs -- d) PH Value 7.5-- e)Total Solid Mg/Lts)PH Value-- No of working hours.16 Hours. Limit of Pump(-) 15% (+) 10% R. M.P. of PumpingRPM(or to be specified by the tenderer) Test run16Hours continueously for 7 days. |
536 | Providing ICTP Main Switch 100 Amp with HRC fuses / Side handled operated Change over switch of L&T/Crompton/Standard/Havells make suitable capacity Operational rating as per IS: 4064 (Part - II) 1978 with up to date amendments immediately after the power meter of HPSEB |
537 | Providing M.S. sheet, steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm, duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories with all internal connections:- |
538 | M.C.B. 100 Amp. Havell/MDS/Standard of make of suitable capacity on incoming feeder with or without initial oil filling as the case may be withneutral linkedunder voltage releases as per IS: 2516 (Part - II) 1985 with up to date amendments with. |
539 | E.L.R. of Havell/MDS/INDETEC make as per IS: 2516 (Part - II) 1985 with upto date amendmentwhich should have control box operating handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape etc. It should also be lifted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end. |
540 | The voltage monitor relay of L&T/AE make three phase with all protection and usual indicator and electric siren against single phasing low voltage, high voltage, reverse phasing, over loading and phase voltage difference as per IS: 1248 (Part - II ) 1983 (Latest edition). |
541 | 100mm square type A.C. supply voltmeter of AE/L&T Rishab make of suitable range with selector switches as per IS: 4064 (Part - II ) -1978 with up to date amendments. |
542 | Power factor meter of AE/L&T Rishab make as perIS: 1248 (Part - V ) 1983(Latest edition) with up to date amendments of suitable rating. |
543 | Frequency meter of AE/ L&T Rishab make as perIS: 1248 (Part - IV ) 1983( Latest edition) with up to date amendments of suitable rating. |
544 | Bus bar chamber with copper strips having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS: 8084-1976 and IS: 11354-1985 read with IS 5578-1985 with up to date amendments 100 Amp. |
545 | ICTP switches with HRC fuses ofL&T/ Standard/Havells make and of suitable capacity as per IS: 4064 (Part - II) -1978 with up to date amendments. 100 Amp. |
546 | Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 ( P-I & II) with up to date amendments. |
547 | 100mmSquare type AC supplyAmmeter of AE /L&T Rishab make of suitable range (0-200) with selector switches and CTS operated as per IS:1248 (P-II) 1983 with up to date amendments. |
548 | Capacitor of L&T make as per IS:2834 -1986 with up to date amendments toraise the power factor at site to 0.95 for direct connections to induction motor individuallyof 9 KVAr ratingaccordingto HP offered including cables as per relevant ISI code (of L&T/Finolex make) from bus bar chamber to capacitor and also including ICTP switches of appropriate rangeas per IS: 4064 (Part - II) 1978 withupto date amendments |
549 | Providing suitable Oil immersed Star Delta starter of M.E.I / Kilburn make as per IS:8544 (Part - II ) -1987 with up to date amendments for Squirrel Cage motor mounted on panel board with magnetic type overload release and dashpot time lag, under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS 1248 (P-V)-1983 with up to date amendments. |
550 | Providing Hour run meter of recommended make as per IS: 722 (Latest edition) |
551 | Providing doubleflanged Cast iron sluice valve of Kirloskar / Leader or JSV approved make for the suction pipe and capable of withstanding the normal seat pressure as per IS: 14846-2000 with up to date amendments (Class PN-1.00, size equal to dia of suction pipe). |
552 | Providing double flangedCast steel sluice valve of Kirloskar / Leader or JSV approved make and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS:1414/API-600 (Class ASA-300 having size one step higher to delivery of pump). |
553 | Providing double flanged Cast steel reflux valve of Kirloskar / Leader or JSV approved make and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS:1868/API-600 (Class ASA-300 having by pass arrangement and size one step higher to delivery of pump). |
554 | Providing double flangedCast steel 80 mm non return valve of Kirloskar / Leader or JSV approved make having bye pass arrangement for rising main and capable of with standing normal sseat pressure of 52 kg/cm2 as per BS:1868/API-600 (Class ASA-300) |
555 | Providing 100mm dia. circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 75 Kg/cm2 |
556 | Providing 100mm dia. vacume dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 760 mercury. |
557 | Installation of all the items appearing at Serial No. 252 to258.01 |
558 | Providing and fixing double flanged 100 mm piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the rising main respectively complete with all specials such as bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as indicated in the drawing No.2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS: 1364-1983. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated under item No.1. |
559 | The size of the various components to be as under:- |
560 | (i) Suction pipe100 mm dia Min. length = 10 mtr. |
561 | (ii)Delivery pipe 80 mm dia -do-= 6 mtr. |
562 | (iii) Common Header100 mm dia-do-= 6 mtr. |
563 | and will extend up to 5 meters from the outer wall of the pump house in the direction to be jointed. |
564 | Providing and laying copper PVC insulated armoured power cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of L&T/Finolex make including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor. |
565 | (i)Motor side:10mm2 Min length = 20 mtrs. |
566 | (ii)Supply side: 16 mm2Min. length =10 mtrs. |
567 | Providing and fixing double loop earthing and G.I. plate 600 mm x 600mm x 3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 32 mm x 3_mm G.I. strips & G.I. wire as per IS: 3043 -1987 withup to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect. |
568 | Centrifugal Pump (LWSS Rawara Ghanalla):- Supply & errection ofhorizontal spindle horizontal split casing/end suctions (back pull out arrangement) Single /double /multistage centrifugal pumps or combination of pumps in series/parellel of Mather & Platt/KSB/ Kirloskar or JSV approved make conforming to BIS 1520-1980) pump (Latest with up to date amendments, read with BIS: 9137-1978(latest edition)suitable for lifting clear/raw water of under mentioned characteristics with bronze/Suitable alloy, priming funnels, casing ring andshaftmotor of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on acommon MS/Cast steel plate (base platefrom the principal manufacturer of pumping set) to coupling 3 phase squirrel cage electric induction motor of standard make such as Kirloskar/ NGEF/Crompton or JSV approved make conforming to IS 12615-2018 and should be energy efficient minimum IE2 compliant and totally enclosed fan cooled (TEFC) type (latest with upto date ammendments) it should include the cost of bearings, nuts & bolts, painting etc. and shall be and suitable for operation on the date given below: |
569 | SITE CONDITIONS:- Total Head209.00 mtrs Discharge required5.40 LPS each set. No. of Pump required. 1.00 Nos sets Length of R/main 2200.00 mtrs. Dia of R/main80mm dia Location of the site of installation of machinery-The site is located at a distance of Km by road &KM on head load (for the installation of both machinery). Type of Current:- AC three phase supply with Rate Voltage:-415+ Type of water and its Charactristics of water a) Ambient Temperature b) Turbidity NTU NTU c) Hardness260 Mg/Ltrs -- d) PH Value 7.5-- e)Total Solid Mg/Lts)PH Value-- No of working hours.16 Hours. Limit of Pump(-) 15% (+) 10% R. M.P. of PumpingRPM(or to be specified by the tenderer) Test run16Hours continueously for 7 days. |
570 | Providing ICTP Main Switch 100 Amp with HRC fuses / Side handled operated Change over switch of L&T/Crompton/Standard/Havells make suitable capacity Operational rating as per IS: 4064 (Part - II) 1978 with up to date amendments immediately after the power meter of HPSEB |
571 | Providing M.S. sheet, steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm, duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories with all internal connections:- |
572 | M.C.B. 100 Amp. Havell/MDS/Standard of make of suitable capacity on incoming feeder with or without initial oil filling as the case may be withneutral linkedunder voltage releases as per IS: 2516 (Part - II) 1985 with up to date amendments with. |
573 | E.L.R. of Havell/MDS/INDETEC make as per IS: 2516 (Part - II) 1985 with upto date amendmentwhich should have control box operating handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape etc. It should also be lifted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end. |
574 | The voltage monitor relay of L&T/AE make three phase with all protection and usual indicator and electric siren against single phasing low voltage, high voltage, reverse phasing, over loading and phase voltage difference as per IS: 1248 (Part - II ) 1983 (Latest edition). |
575 | 100mm square type A.C. supply voltmeter of AE/L&T Rishab make of suitable range with selector switches as per IS: 4064 (Part - II ) -1978 with up to date amendments. |
576 | Power factor meter of AE/L&T Rishab make as perIS: 1248 (Part - V ) 1983(Latest edition) with up to date amendments of suitable rating. |
577 | Frequency meter of AE/ L&T Rishab make as perIS: 1248 (Part - IV ) 1983( Latest edition) with up to date amendments of suitable rating. |
578 | Bus bar chamber with copper strips having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS: 8084-1976 and IS: 11354-1985 read with IS 5578-1985 with up to date amendments 100 Amp. |
579 | ICTP switches with HRC fuses ofL&T/ Standard/Havells make and of suitable capacity as per IS: 4064 (Part - II) -1978 with up to date amendments. 100 Amp. |
580 | Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 ( P-I & II) with up to date amendments. |
581 | 100mmSquare type AC supplyAmmeter of AE /L&T Rishab make of suitable range (0-200) with selector switches and CTS operated as per IS:1248 (P-II) 1983 with up to date amendments. |
582 | Capacitor of L&T make as per IS:2834 -1986 with up to date amendments toraise the power factor at site to 0.95 for direct connections to induction motor individuallyof 9 KVAr ratingaccordingto HP offered including cables as per relevant ISI code (of L&T/Finolex make) from bus bar chamber to capacitor and also including ICTP switches of appropriate rangeas per IS: 4064 (Part - II) 1978 withupto date amendments |
583 | Providing suitable Oil immersed Star Delta starter of M.E.I / Kilburn make as per IS:8544 (Part - II ) -1987 with up to date amendments for Squirrel Cage motor mounted on panel board with magnetic type overload release and dashpot time lag, under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS 1248 (P-V)-1983 with up to date amendments. |
584 | Providing Hour run meter of recommended make as per IS: 722 (Latest edition) |
585 | Providing doubleflanged Cast iron sluice valve of Kirloskar / Leader or JSV approved make for the suction pipe and capable of withstanding the normal seat pressure as per IS: 14846-2000 with up to date amendments (Class PN-1.00, size equal to dia of suction pipe). |
586 | Providing double flangedCast steel sluice valve of Kirloskar / Leader or JSV approved make and capable of with standing nominal seat pressure of 21 kg/cm2 as per BS:1414/API-600 (Class ASA-150 having size one step higher to delivery of pump). |
587 | Providing double flanged Cast steel reflux valve of Kirloskar / Leader or JSV approved make and capable of with standing nominal seat pressure of 21 kg/cm2 as per BS:1868/API-600 (Class ASA-150 having by pass arrangement and size one step higher to delivery of pump). |
588 | Providing double flangedCast steel 80 mm non return valve of Kirloskar / Leader or JSV approved make having bye pass arrangement for rising main and capable of with standing normal sseat pressure of 21 kg/cm2 as per BS:1868/API-600 (Class ASA-150) |
589 | Providing 100mm dia. circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 75 Kg/cm2 |
590 | Providing 100mm dia. vacume dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 760 mercury. |
591 | Installation of all the items appearing at Serial No. 265 to271.01 |
592 | Providing and fixing double flanged 100 mm piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the rising main respectively complete with all specials such as bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as indicated in the drawing No.2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS: 1364-1983. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated under item No.1. |
593 | The size of the various components to be as under:- |
594 | (i) Suction pipe100 mm dia Min. length = 10 mtr. |
595 | (ii)Delivery pipe80 mm dia -do-= 6 mtr. |
596 | (iii) Common Header100 mm dia-do-= 6 mtr. |
597 | and will extend up to 5 meters from the outer wall of the pump house in the direction to be jointed. |
598 | Providing and laying copper PVC insulated armoured power cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of L&T/Finolex make including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor. |
599 | (i)Motor side:10mm2 Min length = 20 mtrs. |
600 | (ii)Supply side: 16 mm2Min. length =10 mtrs. |
601 | Providing and fixing double loop earthing and G.I. plate 600 mm x 600mm x 3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 32 mm x 3_mm G.I. strips & G.I. wire as per IS: 3043 -1987 withup to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect. |
602 | Centrifugal Pump (LWSS Gawalla):- Supply & errection ofhorizontal spindle horizontal split casing/end suctions (back pull out arrangement) Single/double/multistage centrifugal pumps or combination of pumps in series/parellel of Mather & Platt/KSB/ Kirloskar or JSV approved make conforming to BIS 1520-1980) pump (Latest with up to date amendments, read with BIS: 9137-1978(latest edition)suitable for lifting clear/raw water of under mentioned characteristics with bronze/Suitable alloy, priming funnels, casing ring andshaftmotor of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on acommon MS/Cast steel plate (base platefrom the principal manufacturer of pumping set) to coupling 3 phase squirrel cage electric induction motor of standard make such as Kirloskar/ NGEF/Crompton or JSV approved make conforming to IS 12615-2018 and should be energy efficient minimum IE2 compliant and totally enclosed fan cooled (TEFC) type (latest with upto date ammendments) it should include the cost of bearings, nuts & bolts, painting etc. and shall be and suitable for operation on the date given below: |
603 | SITE CONDITIONS:- Total Head225.00 mtrs Discharge required5.00 LPS each set. No. of Pump required. 1.00 Nos sets Length of R/main 1200.00 mtrs. Dia of R/main65mm dia Location of the site of installation of machinery-The site is located at a distance of Km by road &KM on head load (for the installation of both machinery). The Altitude of :-The Altitude of place is982 mtrs above MSL Type of Current:- AC three phase supply with Rate Voltage:-415+ Type of water and its Charactristics of water a) Ambient Temperature b) Turbidity NTU NTU c) Hardness260 Mg/Ltrs -- d) PH Value 7.5-- e)Total Solid Mg/Lts)PH Value-- No of working hours.16 Hours. Limit of Pump(-) 15% (+) 10% R. M.P. of PumpingRPM(or to be specified by the tenderer) Test run16Hours continueously for 7 days. |
604 | Providing ICTP Main Switch 63 Amp with HRC fuses / Side handled operated Change over switch of L&T/Crompton/Standard/Havells make suitable capacity Operational rating as per IS: 4064 (Part - II) 1978 with up to date amendments immediately after the power meter of HPSEB |
605 | Providing M.S. sheet, steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm, duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories with all internal connections:- |
606 | M.C.B. 63 Amp. Havell/MDS/Standard of make of suitable capacity on incoming feeder with or without initial oil filling as the case may be withneutral linkedunder voltage releases as per IS: 2516 (Part - II) 1985 with up to date amendments with. |
607 | E.L.C.B. of Havell/MDS/INDETEC make as per IS: 2516 (Part - II) 1985 with upto date amendmentwhich should have control box operating handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape etc. It should also be lifted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end. |
608 | The voltage monitor relay of L&T/AE make three phase with all protection and usual indicator and electric siren against single phasing low voltage, high voltage, reverse phasing, over loading and phase voltage difference as per IS: 1248 (Part - II ) 1983 (Latest edition). |
609 | 100mm square type A.C. supply voltmeter of AE/L&T Rishab make of suitable range with selector switches as per IS: 4064 (Part - II ) -1978 with up to date amendments. |
610 | Power factor meter of AE/L&T Rishab make as perIS: 1248 (Part - V ) 1983(Latest edition) with up to date amendments of suitable rating. |
611 | Frequency meter of AE/ L&T Rishab make as perIS: 1248 (Part - IV ) 1983( Latest edition) with up to date amendments of suitable rating. |
612 | Bus bar chamber with copper strips having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS: 8084-1976 and IS: 11354-1985 read with IS 5578-1985 with up to date amendments 63 Amp. |
613 | ICTP switches with HRC fuses ofL&T/ Standard/Havells make and of suitable capacity as per IS: 4064 (Part - II) -1978 with up to date amendments. 63 Amp. |
614 | Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 ( P-I & II) with up to date amendments. |
615 | 100mmSquare type AC supplyAmmeter of AE /L&T Rishab make of suitable range (0-60) with selector switches and CTS operated as per IS:1248 (P-II) 1983 with up to date amendments. |
616 | Capacitor of L&T make as per IS:2834 -1986 with up to date amendments toraise the power factor at site to 0.95 for direct connections to induction motor individuallyof 6 KVAr ratingaccordingto HP offered including cables as per relevant ISI code (of L&T/Finolex make) from bus bar chamber to capacitor and also including ICTP switches of appropriate rangeas per IS: 4064 (Part - II) 1978 withupto date amendments |
617 | Providing suitable Oil immersed Star Delta starter of M.E.I / Kilburn make as per IS:8544 (Part - II ) -1987 with up to date amendments for Squirrel Cage motor mounted on panel board with magnetic type overload release and dashpot time lag, under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS 1248 (P-V)-1983 with up to date amendments. |
618 | Providing Hour run meter of recommended make as per IS: 722 (Latest edition) |
619 | Providing doubleflanged Cast iron sluice valve of Kirloskar / Leader or JSV approved make for the suction pipe and capable of withstanding the normal seat pressure as per IS: 14846-2000 with up to date amendments (Class PN-1.00, size equal to dia of suction pipe). |
620 | Providing double flangedCast steel sluice valve of Kirloskar / Leader or JSV approved make and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS:1414/API-600 (Class ASA-300 having size one step higher to delivery of pump). |
621 | Providing double flanged Cast steel reflux valve of Kirloskar / Leader or JSV approved make and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS:1868/API-600 (Class ASA-300 having by pass arrangement and size one step higher to delivery of pump). |
622 | Providing double flangedCast steel 65 mm non return valve of Kirloskar / Leader or JSV approved make having bye pass arrangement for rising main and capable of with standing normal sseat pressure of 52 kg/cm2 as per BS:1868/API-600 (Class ASA-300) |
623 | Providing 100mm dia. circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 75 Kg/cm2 |
624 | Providing 100mm dia. vacume dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 760 mercury. |
625 | Installation of all the items appearing at Serial No. 278 to284.01 |
626 | Providing and fixing double flanged 100 mm piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the rising main respectively complete with all specials such as bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as indicated in the drawing No.2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS: 1364-1983. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated under item No.1. |
627 | The size of the various components to be as under:- |
628 | (i) Suction pipe80 mm dia Min. length = 10 mtr. |
629 | (ii)Delivery pipe65 mm dia -do-= 6 mtr. |
630 | (iii) Common Header 80 mm dia-do-= 6 mtr. |
631 | and will extend up to 5 meters from the outer wall of the pump house in the direction to be jointed. |
632 | Providing and laying copper PVC insulated armoured power cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of L&T/Finolexmake including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor. |
633 | (i)Motor side:4mm2 Min length = 20 mtrs. |
634 | (ii)Supply side: 10 mm2Min. length =10 mtrs. |
635 | Providing and fixing double loop earthing and G.I. plate 600 mm x 600mm x 3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 32 mm x 3_mm G.I. strips & G.I. wire as per IS: 3043 -1987 withup to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail