Tourism Government Departments Closing in 0 days TDR #39582957

Tender For Internal Electrification Works For Construction Of Su Swasthya Kendra Health And Wellness Centre Hwc Type A Under Ridf Xxix For Fy 2023-24 At Dalim, Gorubathan,Kalimpong.

Issued by Government Departments · gorubathan, West Bengal
Tender Value
3.75 Lakhs
Estimated cost
Bid Submission
25 Sep 2023
0 days left
EMD
7510
Bank guarantee accepted
Document Fee
1005
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
gorubathan → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Internal Electrification Works For Construction Of Su Swasthya Kendra Health And Wellness Centre Hwc Type A Under Ridf Xxix For Fy 2023-24 At Dalim, Gorubathan,Kalimpong.

BOQ

Name of Work:Estimate for Internal Electrification work of New Su-Sasthya Kendra (Health & wellness Center) at Dalim, under Gorubathan, Kalimpong,G.T.A.
Sl. No. Item Description
1Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Piano key type switch (Anchor make) fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish a) 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC ii) Average run 8 mtr
2Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire for ECC, incl. necy. PVC clips, fittings etc. to light point with 2 no. 2 way piano key type switch fixed on sheet steel fabricated switch board with Perspex/bakelite top cover on wall incl. necy. connections and making earthing attachment and mending good damages to building works [PVC casing capping on surface and Switch board concealed]
3Supplying and Drawing 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required
4s) 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC
5v) 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC
6y) 2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC
7Supplying and fixing polythene pipe complete with fittings as necy. under ceiling/beam, bound with 22 SWG GI binding wire incl. supplying and drawing 1x18 SWG GI Wire as fish wire inside the pipes and fittings and providing 50 mm dia disc of MS sheet (20 SWG) having colour paint at one face fastened at the load point end of the polythene pipe with fish wire (synchronizing with roof/beam casting work of buildingconstruction)b) 19mm dia 3mm thick Polythene Pipe
8c) 25mm dia 3mm thick Polythene Pipe
9Cutting channel of 40 mm x 40 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works a) 19 mm dia 3 mm thick polythene pipe without earth continuity wire.
10Cutting channel of 43 mm x 43 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works a) 25 mm dia 3 mm thick polythene pipe without earth continuity wire.
11Supplying and fixing PVC casing-capping [Precision Make] on wall or ceiling, incl. necy. PVC fittings etc. and mending good damages to building worksa) 20x10mm Size
12b) 25x10mm Size
13Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. a) 2.5 Sq mm
14b) 4 Sq mm
15c) 6 Sq mm
16Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5A 3 pin plug point incl. S&F 240 V 5A 3 pin flush type plug socket & piano key type switch (Anchor make) incl. S&F earth continuity wire, fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish. a) 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC
17v) Average run 6 mtr (Separate 6A switch Board)
18Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board andbakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
19Supply & Fixing 240 V, 4 nos. 6A, plug socket with separate 4 nos. 6 A Piano key type switch, indicator & 16A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
20Supply & Fixing 240 V, 2 nos. 6A, & 2 nos. 20A plug socket with separate 2 nos. 6 A & 2 nos. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex coverand making necessary connections as required
21Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket with 20/25A Modular switch (Brand approved by EIC) type SP MCB (C-Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
22Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy.Connections.
23Supplying and fixing Sheet steel Main Switches on flat iron frame on walla) 32 Amps DP (Standered/HPL/ Havells make)
24Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl.earthing attachment and painting as required – ( As per Drawing no. 470 of PWD Specification Book – May 1991) a) 2 bars 240V 63 A
25Supplying and fixing Changeover switch with Sheet Steel enclosure on flat iron frame on wall with nutsbolts etc a) 32A 240 DP make Standard/HPL/ Havells
26Supplying and fixing double-door SPN MCB DistributionBoard with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. i) 2+4 way (EDB-1) 607710
27ii) 2+ 8 way (Ground & 1st Floor NDB 2&3)607711
28ii) 2+ 12 way (Ground & 1st Floor EDB 2&3)607712
29Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four poleMCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting,connection & provision for earthing attachment 4 way (NDB 1)
30Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection i) Single Pole 6-32A (SPNDB Outgoing)
31ii) Single Pole 25 A MCB (EDB 1 Outgoing)
32iii) Double Pole 32 A MCB ( EDB 1, NDB 2, 3)
33iv) Double Pole 32 A MCB ( UPS)
34v) Double Pole 25A MCB (EDB 2,3 Incomer)
35vi) Double Pole 25A MCB (NDB 1 4way)
36Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cuttingbakelite/perspex top cover incl. making necy. connections etc.
37Supplying & Fixing of Box type fan clamp of 150mm dia & 80mm depth made of 16 SWG CRCA sheet with one end duly sealed by cover, properly welded, incl. S&F 12mm dia 600mm long MS rod duly bent by heat treatment at the centre position of rod to grip fan bobbin properly, incl. binding the rod and fan box with reinforcement by 22 SWG steel binding wire, incl. supplying & covering the box with alkathene sheet, placed in order to prevent concrete fromentering the box.
38Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.
39b) 30 cm (12\")
40Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) For Al. 30 cm (12\")
41Supplying & Fixing 240 V AC Buzzer (Ancho) on HW board incl. S&F HW board
42Laying on Wall / surface with Saddles / clamps Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
43Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below For 2 core upto 16 Sq. mm
44Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials For 2 Core 16 Sq. mm
45Excavation of soil for installation of Earth Electrode and filling & ramming for Morrom Soil
46Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled withbitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By TATA-Medium GI pipe ( Mains Earthing 2, UPS Neutral 1)
47Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos.12 mm dia holes on the GI pipe
48Extra for treatment of soil by using salt & charcoal or coke for plate electrode
49Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
50Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.
51Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damagesSolid Wire GI ii) 6SWG
52Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core strandedannealed copper wire and making connections as required and mending good damages to wall incl. painting etc.
53Fixing only single /twin fluorescent light fitting complete with all accessories directly on wall/ceiling/HW round block and suitable size of MS fastener
54Fixing only Lamp
55Supplying only AC celling fan1200mmEPC make. Or Usha Plus or Crompton
56Supplying only Ventilating Fan Ventil Air-DB 300 mm, Havells EPC Crompton make.
57Supplying of 1.1 KV grade L.T. Power cable, XLPE insulated, cores laid up, PVC inner Sheathed aluminium ArmouredConductor of Polycab/Gloster/Havells make, 16 Sq. mm. 2 Core
58Supply and Delivery of single 4ft LED Tube light fittings of 22 W make of Philips/ Havells/Crompton.
59Supply and Delivery of 45W LED Outdoor Type Luminiaries along with all accessories complete make of Crompton/ Havells.
60Supply and delivery at site 9 W LED Bulb make of Philips/Havells/ Cromption
61WBSEDCL CHARGES

AI Tender Summary

OUR REF NO 39582957
AUTHORITY Government Departments
TENDER VALUE 3.75 Lakhs
LAST DATE 25-09-2023
Authority
Authority Name Gorkhaland Territorial Administration
Work Description Internal Electrification Works For Construction Of Su Swasthya Kendra Health And Wellness Centre Hwc Type A Under Ridf Xxix For Fy 2023-24 At Dalim, Gorubathan,Kalimpong.
Basic Detail
Tender No 10 of 2023-24
Bidding Type Tender
Location
City gorubathan
State West Bengal
Key Dates
Publish Date 11 Sep 2023
Submission Date 25 Sep 2023
Open Date 27 Sep 2023
Finance
Tender Value 3.75 Lakhs
Tender Fee 1005
EMD 7510
Exemption Not Available
Document List
54a5436f-a3e7-4258-9552-be7f06ee4c0e.html
BOQ_1182883.xls
Tendernotice_1.pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 11, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 25, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Sep 27, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

54a5436f-a3e7-4258-9552-be7f06ee4c0e.html

xls

BOQ_1182883.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

Disclaimer