| 1 | ERRECTION AND SUPPLY DETAILS |
| 2 | LOCAL/DE-CENTRALISED ITEMS TO SUPPLY |
| 3 | AL LUG 35 SQ MM |
| 4 | AL LUG 70 SQ MM |
| 5 | AL LUG 120 SQ MM |
| 6 | AL LUG 150 SQMM |
| 7 | AL LUG 240 SQ MM |
| 8 | AL. LUG 400 SQMM |
| 9 | LT CABLE JOINTING KIT SIZE 3.5X240 FOR TAPPING OF LT LINE |
| 10 | 11 KV JOINTING KIT OUTDOOR 120 SQMM |
| 11 | HS 11 KV CABLE JOINTING KIT (3X70) SQMM I/D |
| 12 | HS 11 KV CABLE JOINTING KIT (3X70) SQMM O/D |
| 13 | HS 11 KV CABLE JOINTING KIT (3X70) SQMM S/T |
| 14 | HS 11 KV CABLE JOINTING KIT (3X120) SQMM I/D |
| 15 | HS 11 KV CABLE JOINTING KIT (3X120) SQMM 0/D |
| 16 | HS 11 KV CABLE JOINTING KIT (3X185) SQMM I/D |
| 17 | HS 11 KV CABLE JOINTING KIT (3X185) SQMM O/D |
| 18 | HS 11 KV CABLE JOINTING KIT (3X185) SQMM S/T |
| 19 | HS 11 KV CABLE JOINTING KIT (3X240) SQMM I/D |
| 20 | HS 11 KV CABLE JOINTING KIT (3X240) SQMM O/D |
| 21 | HS 11 KV CABLE JOINTING KIT (3X240) SQMM S/T |
| 22 | HS 11 KV CABLE JOINTING KIT (3X300) SQMM I/D |
| 23 | HS 11 KV CABLE JOINTING KIT (3X300) SQMM O/D |
| 24 | HS 11 KV CABLE JOINTING KIT (3X300) SQMM S/T |
| 25 | HS 33 KV CABLE JOINTING KIT (3X50) SQMM I/D |
| 26 | HS 33 KV CABLE JOINTING KIT (3X50) SQMM O/D |
| 27 | HS 33 KV CABLE JOINTING KIT (3X50) SQMM S/T |
| 28 | HS 33 KV CABLE JOINTING KIT (3X70) SQMM I/D |
| 29 | HS 33 KV CABLE JOINTING KIT (3X70) SQMM O/D |
| 30 | HS 33 KV CABLE JOINTING KIT (3X70) SQMM S/T |
| 31 | HS 33 KV CABLE JOINTING KIT (3X120) SQMM I/D |
| 32 | HS 33 KV CABLE JOINTING KIT (3X120) SQMM O/D |
| 33 | HS 33 KV CABLE JOINTING KIT (3X120) SQMM S/T |
| 34 | HS 33 KV CABLE JOINTING KIT (3X185) SQMM I/D |
| 35 | HS 33 KV CABLE JOINTING KIT (3X185) SQMM O/D |
| 36 | HS 33 KV CABLE JOINTING KIT (3X185) SQMM S/T |
| 37 | HS 33 KV CABLE JOINTING KIT (3X240) SQMM I/D |
| 38 | HS 33 KV CABLE JOINTING KIT (3X240) SQMM O/D |
| 39 | HS 33 KV CABLE JOINTING KIT (3X240) SQMM S/T |
| 40 | HS 33 KV CABLE JOINTING KIT (3X300) SQMM I/D |
| 41 | HS 33 KV CABLE JOINTING KIT (3X300) SQMM O/D |
| 42 | HS 33 KV CABLE JOINTING KIT (3X300) SQMM S/T |
| 43 | BOLT NUT AND WASHER ALL SIZE |
| 44 | END CAP FOR AB CABLE |
| 45 | INSULATING MASTIC TAPE (2INCX10FEET) |
| 46 | PG CLAMPS 16 SQMM - 50 SQMM (FOR LINE TO LINE JUMPERING) |
| 47 | ANGLE FOR VERTICAL ARM WITH FITTING AS PER REQUIREMENT |
| 48 | BACK CLAMP FOR HEIGHT RAISING CHANNEL HLODING CALMPS WITH BOLT AND NUT |
| 49 | SUPPLY OF LT PVC CABLE (ARMOURED) 4*16 SQMM |
| 50 | SUPPLY OF LT PVC CABLE (ARMOURED) 2*6/10 SQMM |
| 51 | 4X2.5 SQ.MM |
| 52 | 2X2.5 SQ.MM |
| 53 | STONE PAD |
| 54 | ALLUMINIUM BINDING WIRE -6 SWG |
| 55 | JOINTING SLEEVE ACSR DOG |
| 56 | PG CLAMP FOR ACSR DOG |
| 57 | TURN BUCKLE |
| 58 | M.S. ANGLE IRON 65*65*6 MM, 4300 MM LONG BRACING WITH CLAMP |
| 59 | EYE BOLT |
| 60 | NUT & BOLTS WITH WASHERS ALL SIZE |
| 61 | FEEDER PILLER BOX PANEL WITH FUSE UNIT & DISTRIBUTION BUS BAR HAVING INSULATION OF IP66 & ABOVE FOR INSTALLATION IN OPEN AREA WITH LOCKING ARRANGEMENT COMPLETE IN ALL RESPECT. (TYPE C) |
| 62 | LT RISES LT INCOMING PANEL WITH PROTECTION& METERING ARRANGEMENT TYPE B(250 AMP MCCB INCOMER & 3 NO. O/G MCCB 100 AMP PROVISION) |
| 63 | PG CLAMP 16 SQMM-50 SQMM (FOR LINE TO LINE JUMPERING) |
| 64 | CU. L-CLAMP |
| 65 | HT TAPE FOR SEALING OF LT |
| 66 | 11 KV CT METERING/DLMS UNIT COMPLETE |
| 67 | 24 VOLT BATTERY AND BATTERY CHARGER WITH CABINET |
| 68 | BARBED WIRE FENCING WITH GATE ETC (SWITCHYARD) |
| 69 | HT TAPE |
| 70 | LABELS RATING/NUMBER PLATES |
| 71 | TAPE CHAGING GEAR |
| 72 | 11 KV DANGER BOARD WITH CLAMPS & BOLTS |
| 73 | BARBED WIRE GI |
| 74 | GI PIPE 6\" DIA |
| 75 | CABLE ROUTE & CABLE MARKER |
| 76 | TAPE VOLATGE INDICATOR DIGITAL TYPE |
| 77 | LOCAL REMORT SELECTOR SWITCH |
| 78 | BUZZER AND LAMP TO INDICATE TAP CHANGING IN PROGRESS |
| 79 | BUCCHOLZ RELAY |
| 80 | PRESSURE RELIVE VALVE |
| 81 | GROUND BOND RESITANCE/ERATH RESISTANCE TESTER |
| 82 | 33 KV BUSHING FOR POWER TRANSFORMER |
| 83 | 11 KV BUSHING FOR POWER TRANSFORMER |
| 84 | 11 KV NEUTRAL BUSHING COMPLETE |
| 85 | WINDING TEMPERATURE INDICATOR |
| 86 | OIL TEMPERATURE INDICATOR |
| 87 | INSULATED RUBBER MATS FOR THE ELECTRICAL PANELS |
| 88 | CURRENT TRANFORMERS (CT) 600/400/5-A |
| 89 | CURRENT TRANFORMERS (CT) 400/200/5-A |
| 90 | CURRENT TRANFORMERS (CT) 200/100/5-A |
| 91 | POTENTIAL TRANSFOMRER (PT) 11KV/110V |
| 92 | CONTROL SWITCHES |
| 93 | ALARM AND INDICATION LAMP |
| 94 | VARIOUS TYPE OF CABLE CONNECTORS |
| 95 | SWITCH GEAR MIMIC DIAGRAM IN RED COLOUR |
| 96 | MECHANICAL INTERLOCKS FOR SWITCH GEAR |
| 97 | SUPPLY OF VARIOUS TYPE OF CIRCUIT BREAKER OPERATING MECHANISHM |
| 98 | 11 KV OVER CURRENT AND EARTH FAULT RELAYS |
| 99 | 33 KV OVER CURRENT AND EARTH FAULT RELAYS |
| 100 | UNDER FREQUENCY REPLAY |
| 101 | 24 VOLT DC SWITCH BOARD |
| 102 | BRAETHING MASK FOR FIRE FIGHTING WITHIN THE SUBSTATION |
| 103 | PLASTIC HELMETS |
| 104 | 20 KV INSULATING GLOVES |
| 105 | SUITABLE INSULATED STOOL |
| 106 | 33 KV AND 11 KV VOLATGE INDICATOR ROD OF THE TELESCOPIC TYPE |
| 107 | RECHARGEABLE TORCH LIGHT |
| 108 | PORTABLE CARRIAGE MOUNTED FIRE EXINGUISHER SUITABLE FIRE ELECTRICAL FIRE |
| 109 | INSTRUCTION AGAINST ELECTRICAL SHOCKS AND ARTIFICIAL BREATHING IN HINDI OR ENGLISH LANGUAGE |
| 110 | COMLETE SET OF SAFETY REGULATION SIGNS FOR OPEN CIRCUIT , DANGER ZONE ETC IN HINDI LANGUAGE |
| 111 | DRAWING AND INSTRUCTION BOOKS/CHART |
| 112 | COMBINED CT PT UNIT FOR POLE METERING |
| 113 | 33 KV PT (OUTDOOR) 33KV/110V |
| 114 | SILICA GEL |
| 115 | CABLE STIPPERS |
| 116 | INSULATED SCREW DRIVER |
| 117 | PLIERS |
| 118 | ELECTRICSL TAPE |
| 119 | HACKSAW |
| 120 | CABLE CUTTER |
| 121 | SPANNER |
| 122 | VOLATEG TESTER |
| 123 | SAFETY KNIFE |
| 124 | HEX KEYS |
| 125 | CLAW HAMMER |
| 126 | CHISEL |
| 127 | ELECTRICIAN TOOL KIT |
| 128 | 5KV 10KV 15KV HIGH VOLTAGE INSULATION RESISTANCE TESTER/MEGGER |
| 129 | NON-CONDUCTIVE LADDER MADE OF WOOD OR FIBERGLASS |
| 130 | 33KV CT 400/200/1-1-1A |
| 131 | NO LOAD FAULT LOCATING MACHINES REQUIRED |
| 132 | FAULT PASS INDICATORS REQUIRED |
| 133 | TROLLEY WITH WHEEL AND ALL REQUIRED ACCESSORIES |
| 134 | EARTHING OF FEEDER PILLER BOX (CHEMICAL/PIPE/PLATE ETC) COMPLETE FOR CABLE |
| 135 | OUTDOOR SWITCHYARD &APPROACH ROAD LIGHTING |
| 136 | 11 KV LIGHTNING ARRESTER |
| 137 | 4 CORE LT MCB WITH BOX - LT INCOMING PROTECTION PANEL WITH METERING EQUIPMENT (TYPE-A 100 TO 500 AMP 4POLE MCB WITH BOX /LT PROTECTION PANEL) |
| 138 | 33 KV LIGHTNING ARRESTOR |
| 139 | 33 KV VCB WITH SINGLE T/F CONTROL PANNEL AND CT 200/100/1 A WITH STRUCTURE |
| 140 | 33 KV VCB WITH DOUBLET/F CONTROL PANNEL AND CT 200/100/1 A WITH STRUCTURE |
| 141 | ERECTION/SERVICES OF ABOVE ITEMS (PART-B) |
| 142 | M.S. & CIVIL STRUCTURE FOR FEEDER PILLER BOX INSTALLATION |
| 143 | ONSITE MAINTENANCE AND SUPPLY OF REQUIRED ACCESORIES PRE-INSTALLED CAPACITOR BANK AND THEIR ACCESORIES FOR SUCCESFULLY OPERATION SUCH AS OVER COMPENSATION, OVER VOLTAGE, OVER CURENT, ERATH FAULT, AMMETERS, KVAR METEERS AND OTHERS |
| 144 | GIVING THE GENUINE CONSUMER SERVICE CONNECTION THROUGH INSTALLED LT DISTRIBUTION BOX INCLUDING DISCONNECTION & RECONNECTION |
| 145 | REPAIRING OF 9/11 M ST/RSJ POLE BY MUFFING AND BREAKING CC/HARD SURFACE OF RUSTED AND TILTED ST POLE AND DIGGING ABOUT 4 FEET TO PREVENT, GROUT AND MUFFING WITH THE HELP OF STONES ETC IN WELL MADE PITS |
| 146 | TRENCH WORK FOR LT LINE(SIZE 3X1.5 FEET, BRICK WORK 9 INCH WALL, CONCREATING IN BASE, TRENCH COVER 4 INCH, 2 SECTION WITH MS CHANNEL) |
| 147 | SUNDARY CHARGES FOR EXTRA MATERIAL I.E. CABLE GLANDS, OFF SIZE LUGS, PVC PIPE ETC |
| 148 | NUMBER/DT CODE ETC MARKING ON POLE BY PAINT, YELLOW BASE WILL BE PREPARED AND NUMBER SHALL BE WRITTEN BY BLACK PAINT (PAINT PROVIDED BY CONTRACTOR) |
| 149 | PLINTH COMPLETE |
| 150 | WIRE MESH FENCING WITH DOOR COMPLETE |
| 151 | LAYING OF 11 KV CABLE INCLUDING COST OF SAND AND BRICKS |
| 152 | MAKING OF 11KV CABLE BOXES MOUNTED WITH SWITCH GEAR AND TRANSFORMER |
| 153 | MAKING OF 11 KV STRAIGHTH THORUGH |
| 154 | MAKING OF 33 KV CABLE BOXESMOUNTED WITH SWITCH GEAR AND TRANSFORMER |
| 155 | PAINTING OF S/S STRUCTURE |
| 156 | SUNDRY STORES |
| 157 | ROAD RESTORATION CHARGES FOR PUCCA ROAD |
| 158 | ROAD RESTORATION CHARGES FOR KACHHA FOOTPATH SIDE |
| 159 | CONCRETING OF POLES |
| 160 | PAINTING OF POLE WITH RED OXIDE /SILVER OXIDE PAINT OF TWO COAT (PAINT PROVIDED BY CONTRACTION) |
| 161 | NUMBER MARKING ON POLE BY PAINT, YELLOW BASE WILL BE PREPARED AND NUMBER SHALL BE WRITTEN BY BLACK PAINT (PAINT PROVIDED BY CONTRACTOR) |
| 162 | REPAIRING OF PLINTH OF POWER TRANSFORMER |
| 163 | LAYING, SAGGING & BINDING OF AB CABLE FOR CONSTRUCTION OF LT LINE. |
| 164 | LAYING ACSR CONDUCTOR WEASEL/RACOON/DOG |
| 165 | SAFE LOADING, CARRIAGE AND UNLOADING OF PCC/ST POLE 13/11/09/8.5 MTR. LONG FROM ESC HASARI STORE/JE STORE TO WORK SITE. |
| 166 | SAFE LOADING, CARRIAGE & UNLOADING OF LINE MATERIAL(I.E. ACSR CONDUCTOR, 11KV CABLE. AB CABLE, OTHER CABLES, MS MATERIAL, CLAMPS ETC) FROM ESC HASARI STORE/JE STORE TO WORK SITE. |
| 167 | ERECTION OF PCC/ST POLE 8.5/09/11/13 METER LONG SP-33/55/70 INCLUDING FIXING OF ALL ACCESSORIES FOR LT/HT/EHT LINE COMPLETE WITH CONCRETING & PLINTH. |
| 168 | ERECTION OF DOUBLE POLE STRUCTURE WITH FIXING OF ALL ACCESSORIES I.E. TOP CHANNEL, DROPPER CHANNEL,BRASING ANGLE, CLAMPS ETC INCLUDING CONCRETING OF POLES FOR SECTION POLE. |
| 169 | ERRECTION AND MAKING OF 11 KV FEEDER ISOLATION AS PER ESTIMATES |
| 170 | ERECTION OF TRI-POLE STRUCTURE WITH FIXING OF ALL ACCESSORIES I.E. TOP CHANNEL, DROPPER CHANNEL, BRACING, CLAMPS ETC INCLUDING CONCRETING OF POLES FOR RECTANGLEN OR TURN |
| 171 | ERECTION OF FOUR-POLE STRUCTURE WITH FIXING OF ALL ACCESSORIES I.E. TOP CHANNEL, DROPPER CHANNEL, BRACING, CLAMPS ETC INCLUDING CONCRETING OF POLES FOR RECTANGLE OR TURN |
| 172 | CONSTRUCTION OF DOUBLE POLE STRUCTURE WITH ST POLE 11 MTR LONG SP-55 INCLUDING FIXING OF ALL ACCESSORIES COMPLETE WITH CONCRETING & PLINTH FOR 25/63/100 KVA, 11/0.4 KV POLE MOUNTED SUB-STATION. |
| 173 | CONSTRUCTION OF DOUBLE POLE STRUCTURE WITH ST POLE 11 MTR LONG SP-55 INCLUDING FIXING OF ALL ACCESSORIES COMPLETE WITH CONCRETING & PLINTH FOR 250/400 KVA, 11/0.4 KV PLINTH MOUNTED SUB-STATION. |
| 174 | EARTHING OF POLE BY EARTHING ROD, GI WIRE ETC. COMPLETE |
| 175 | ERECTION OF STAY SET COMPLETE AS PER RESPO MANUAL INCLUDING THEIR CONCRETING. |
| 176 | LAYING OF ARMOURED CABLE SIZE 4CX16 SQMM, 2CX6/10 SQMM FOR CONSUMER SERVICE CONNECTION. |
| 177 | DISCOONECTION & RECOONECTION OF CONSUMER CONNECTION FOR REPLACEMENT OF DAMAGE NON ARMOURED CABLE |
| 178 | PAINTING OF POLE WITH RED OXIDE PAINT & ALUMINIUM PAINT AND NUMBERING OF POLE WITH BLACK OVER YELLOW BASE. |
| 179 | EXTRA PIT DIGGING IN HARD STIFF & UNEVEN AREA AS PER REQIUREMENT |
| 180 | LAYING OF 11 KV CABLE OF SIZE 3X185/120/70/35 SQ MM 11 KV AS PER SITE REQUIREMENT |
| 181 | DIGGING OF HORIZONTAL BORING UNDER THE HIGHWAY/RAILWAY TRACK FOR FIXING OF HDPE PIPE FOR LAYING OF 11 KV CABLE AS PER SITE REQUIREMENT. |
| 182 | DIGGING OF CABLE TRENCH AND COVER WITH FIRST CLASS BRICKS PROTECTION AND FILLING THE RIVER SAND INCLUDING BACK FILLING BY SANDFOR LAYING OF 11 KV CABLE WITH FIXING OF HDPE/GI PIPE (AS PER NEED) AND CABLE ROUTE MARKER ALSO COMPLETE. |
| 183 | CHEMICAL/PIPE(WATER LEVEL) EARTHING (AS PER REQUIREMENT OF SITE) FOR 11 KV CABLE ETC. |
| 184 | SUPPLY OF GI PIPE 6\" DIA IF NOT AVAILABLE IN STORE |
| 185 | SUPPLY OF HDPE PIPE (PE63, 10KG/CM3, IS 4984:1995) 6\" DIA OR EQUIVALENT IF NOT AVAILABLE IN STORE |
| 186 | SUPPLY & FIXING OF PIPE JOINTS IF NOT AVAILABLE IN STORE |
| 187 | SUPPLY & FIXING OF CABLE ROUTE MARKER IF NOT AVAILABLE IN STORE |
| 188 | TRIMMING & CHOPPING OF TREE BRANCHES ASPER SITE REQUIREMENT |
| 189 | DISMENTALLING OF O&U STP |
| 190 | DISMANTALLING OF ST/RAIL/JOIST/PCC POLE OF LT/HT LINE SHORT IN LENGTH |
| 191 | DISMANTALLING OF LINE MATERIAL (ACSR CONDUCTOR, AB CABLE, CROSS ARMS, VARIOUS CLAMPS ETC) OF HT 11 KV/LT LINE. |
| 192 | LOADING, CARRIAGE & UNLOADING OF EXISTING POLES & LINE MATERIAL SCRAP FROM SITE TO STORE. |
| 193 | EXTRA R&M WORKS ON EXISTING NETWROK FOR STRENGTHING |
| 194 | CARRIAGE OF TF 25/63/100 KVA 11/0.4 KV FROM ESC HANSARI TO PERTICULER SITE |
| 195 | CARRIAGE OF TF 250/400/630 KVA 11/0.4 KV FROM ESC HANSARI TO PERTICULER SITE |
| 196 | MOUNTING OF T/F 25/63/100 KVA S/SFIXING OF 11 KV CABLE/JUMFER AND L.T.CABLE FOR ENERGIZATION OF LINE AND T/F |
| 197 | MOUNTING OF T/F 250/400 KVA S/S FIXING OF 11 KV CABLE/JUMFER AND L.T.CABLE FOR ENERGIZATION OFLINE AND T/F |
| 198 | DISMENTALLING OF 25/63/100 KVA T/F (O&U)INCLUDING CARRIAGE OF T/F FROM WORKING SITE TO ESC HANSARI STORE JHANSI |
| 199 | DISMENTALLING OF 250/400 KVA T/F (O&U)INCLUDING CARRIAGE OF T/F FROM WORKING SITE TO ESC HANSARI STORE JHANSI |