Tender For Extension Of Power Supply To Mata Temple At Village Rajgad Under Kolaras R D/C Under Onm Dn Ii Shivpuri (Nit-25), kolaras-Madhya Pradesh

Madhya Pradesh Madhya Kshetra Vidyut Vitaran Company Limited-MPMKVVCL has published Tender For Extension Of Power Supply To Mata Temple At Village Rajgad Under Kolaras R D/C Under Onm Dn Ii Shivpuri (Nit-25). Submission Date for this Tender is 14-09-2023. Electrical Maintenance Tenders in kolaras Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

39572583
Tender For Extension Of Power Supply To Mata Temple At Village Rajgad Under Kolaras R D/C Under Onm Dn Ii Shivpuri (Nit-25)
Open Tender
Indian
Madhya Pradesh
kolaras
14-09-2023

Tender Details

Tender For Extension Of Power Supply To Mata Temple At Village Rajgad Under Kolaras R D / C Under Onm Dn Ii Shivpuri ( Nit-25 ) ; 1 Dtr 25 Kva 11 / .04 Kv Bis Certified Level-Ii 2 Labour Charge For Installation Dtr 25 Kva 11 / .04 Kv Bis Certified Level-Ii 3 Bimetalic Clamp Distribution Transformers Bushing 4 Bi-Metallic Clamps Suitable For 12Mm Dia Stud And 80Sqmm Aaac 5 Transformer Belting Set 50X50x6 Mm Angle With Two Cross Fixing Channel 6 Three Phase Static Energy Meters 20-80 Amps.With L.S. & Tod Facility With Box 7 Labour Charge For Installation Three Phase Static Energy Meters 20-80 Amps.With L.S. & Tod Facility With Box 8 Pcc Pole 9 Mtr 200 Kg 9 Labour Charge For Digging And Erection Ofpcc Pole 9 Mtr 200 Kg 10 Xlpe 1 Core Unarmoured 35 Sqmm Aluminium Conductor 1100 Volts 11 Labour Charge For Xlpe 1 Core Unarmoured 35 Sqmm Aluminium Conductor 1100 Volts 12 Aaac Raccoon Conductor 0.075 Sq.Inch ( 80 Sq.Mm. Al.Eq. ) 13 ( Labour Charge ) Aaac Raccoon Conductor 0.075 Sq.Inch ( 80 Sq.Mm. Al.Eq. ) 14 Aaac Rabbit Conductor 0.05 Sq.Inch ( 55 Sq.Mm. Al.Eq. ) ( Conductor Acsr Scrap ) 15 Labour Charge For Stringing Aaac Rabbit Conductor 0.05 Sq.Inch ( 55 Sq.Mm. Al.Eq. ) ( Conductor Acsr Scrap ) 16 11 Kv D.O. Fuse Unit Polymer Type 17 Labour Charge For Fixing Of 11 Kv D.O. Fuse Unit Polymer Type 18 Stay Insulator 90X65 19 D.O. Mounting Channel 75X40x6 Mm 20 Labour Charge For Fixing Ofd.O. Mounting Channel 75X40x6 Mm 21 11 Kv Polymer Lightening Arrestor Gapless Type 22 Labour Charge For Fixing11 Kv Polymer Lightening Arrestor Gapless Type 23 11 Kv Composit Polymer Disc Insulator 24 Labour Charge For Fixing Of11 Kv Composit Polymer Disc Insulator 25 11 Kv Strain Hardware ( T&C Type ) Fittings 26 Labour Charge For Fixing Of11 Kv Strain Hardware ( T&C Type ) Fittings 27 Bracing / Support Anglr Of 65X65x6 Mm For 5 ( 1.5 Mtr ) Center Dp 28 Labour Charge For Fixing Ofbracing / Support Anglr Of 65X65x6 Mm For 5 ( 1.5 Mtr ) Center Dp 29 D.C. Cross Arms 8 Channel ( 100X50x6mm ) 30 Labour Charge For Fixing Of D.C. Cross Arms 8 Channel ( 100X50x6mm ) 31 Transformer Mounting Channel 32 Labour Charge For Fixing Transformaer Mounting Channel 33 11 Kv Polymer Pin Insulator 34 ( Labour Charge ) 11 Kv Polymer Pin Insulator 35 11 Kv V Cross Arm 65X65x6 Mm Angle Type 36 Labour Charge For Fixing Of 11 Kv V Cross Arm 65X65x6 Mm Angle Type 37 11 Kv Top Clamp 65X65x6 Mm Angle Type 38 Labour Charge For Fixing Of11 Kv Top Clamp 65X65x6 Mm Angle Type 39 Stay Set Complete Without Stay Wire 16 Mm ( Painted ) 40 Labour Charge For Fixing Ofstay Set Complete Without Stay Wire 16 Mm ( Painted ) 41 Stay Wire 7 / 3.15 Mm ( 7 / 10 Swg ) 42 Stay Clamp 65X8 Mm Of Ms Flat For Pcc Pole 280 Kg 43 G.I. Wires 4.0 Mm ( 8Swg ) 44 Meter Cum Protection Box For 25 Kva Dtr 45 Labour Charge For Fixing Meter Cum Protection Box For 25 Kva Dtr 46 Anti Climbing Devices ( Barbed Wire ) Gs 2.24 Mm Dia ( 14 Swg ) 47 Labour Charge For Fixing Of Anti Climbing Devices ( Barbed Wire ) Gs 2.24 Mm Dia ( 14 Swg ) 48 Clamp For 140 Kg Pcc Pole Ms Flat 50X6 Mm Ms Flat ( 65X8 Mm ) 49 Back Clamp For 140 Kg Pcc Pole Ms Flat ( 50X6 Mm ) 50 Back Clamp For 280 Kg Pcc Pole Ms Flat ( 50X8 Mm ) 51 Stone Block / Per Cast Block For Base Pedding ( 450X450x75mm ) 52 Back Filling Of Pole With Boulders 53 Concreting Of Structures & Foundation ( 1:3:6 ) 54 ( Labour Charge ) Concreting Of Structures & Foundation ( 1:3:6 ) 55 Concreting Of Stay ( 16 Mm / 12 Mm ) @0.2 Cmt. Per Stay 56 Labour Charge For Concreting Of Stay ( 16 Mm / 12 Mm ) @0.2 Cmt. Per Stay 57 Red Oxide Paint 58 Labour Charge Forred Oxide Paint 59 Aluminium Paint 60 Labour Charge For Aluminium Paint 61 M.S.Nuts And Bolts 62 Danger Board Enamelled 11 Kv 63 Labour Charge Fordanger Board Enamelled 11 Kv 64 Jointing Sleeves Suitable For Rabbit ( 55 Sq.Mmal.Eq. ) Aaac Conductor 65 Earthing Of Dtr As Per G1 Schedule G1 For Black Cotton Soil 66 Earthing For Pcc Pole4.00 Mm 8 Swg G.I. Wire 0.8 Kg Per Pole 67 Earthing Coil Of 115 Turns Of 50 Mm Dia And 2.5 Mtr. Lead Of 4.0 Mm G.I. Wire 68 M.S Strain Plat65x8 Mm 250Mm Long 69 Aluminium Binding Wire And Tape 70 Sgst @ 9% 71 Cgst @ 9%

Key Value

Document Fees
INR 218 /-
EMD
INR 3000.0 /-
Tender Value
INR 1.49 Lakhs /-

BOQ Items

Name of Work :DGM Store Extension of power supply to mata mandir at village rajgad under Kolaras R D/c under O&M Dn II shivpuri (896337)
Sl. No. Item Description
1DTR 25 KVA 11/.04 KV BIS Certified LEVEL-II
2Labour Charge for installation DTR 25 KVA 11/.04 KV BIS Certified LEVEL-II
3BIMETALIC CLAMP DISTRIBUTION TRANSFORMERS BUSHING
4Bi-metallic clamps suitable for 12mm dia stud and 80sqmm AAAC
5Transformer Belting Set 50X50X6 MM Angle with Two cross fixing channel
6Three phase Static Energy meters 20-80 Amps.with L.S. & TOD Facility with box
7Labour Charge for installation Three phase Static Energy meters 20-80 Amps.with L.S. & TOD Facility with box
8PCC Pole 9 mtr 200 KG
9Labour Charge for digging and erection ofPCC Pole 9 mtr 200 KG
10XLPE 1 core unarmoured 35 Sqmm aluminium conductor 1100 volts
11Labour charge for XLPE 1 core unarmoured 35 Sqmm aluminium conductor 1100 volts
12AAAC Raccoon conductor 0.075 sq.inch (80 sq.mm. Al.Eq.)
13( Labour Charge)AAAC Raccoon conductor 0.075 sq.inch (80 sq.mm. Al.Eq.)
14AAAC Rabbit conductor 0.05 sq.inch (55 sq.mm. Al.Eq.) (Conductor ACSR scrap)
15Labour Charge for stringing AAAC Rabbit conductor 0.05 sq.inch (55 sq.mm. Al.Eq.) (Conductor ACSR scrap)
1611 KV D.O. Fuse unit Polymer type
17Labour Charge for fixing of 11 KV D.O. Fuse unit Polymer type
18Stay Insulator 90X65
19D.O. Mounting Channel 75x40x6 mm
20Labour Charge for fixing ofD.O. Mounting Channel 75x40x6 mm
2111 KV Polymer Lightening arrestor Gapless type
22Labour Charge for fixing11 KV Polymer Lightening arrestor Gapless type
2311 KV Composit Polymer Disc insulator
24Labour Charge for fixing of11 KV Composit Polymer Disc insulator
2511 KV Strain Hardware (T&C type) fittings
26Labour Charge for fixing of11 KV Strain Hardware (T&C type) fittings
27Bracing/support anglr of 65x65x6 mm for 5" (1.5 mtr) center DP
28Labour charge for fixing ofBracing/support anglr of 65x65x6 mm for 5" (1.5 mtr) center DP
29D.C. Cross arms 8" Channel (100x50x6mm)
30Labour Charge for fixing of D.C. Cross arms 8" Channel (100x50x6mm)
31Transformer mounting Channel
32Labour Charge for fixing Transformaer Mounting Channel
3311 KV polymer Pin Insulator
34( Labour Charge)11 KV polymer Pin Insulator
3511 KV V cross arm 65x65x6 mm angle type
36Labour charge for fixing of 11 KV V cross arm 65x65x6 mm angle type
3711 KV top clamp 65x65x6 mm angle type
38Labour charge for fixing of11 KV top clamp 65x65x6 mm angle type
39Stay set complete without Stay wire 16 mm (Painted)
40Labour Charge for fixing ofStay set complete without Stay wire 16 mm (Painted)
41Stay wire 7/3.15 MM (7/10 SWG)
42Stay clamp 65x8 mm of MS flat for PCC pole 280 KG
43G.I. Wires 4.0 MM (8SWG)
44Meter cum Protection Box for 25 KVA DTR
45Labour charge for fixing Meter cum Protection Box for 25 KVA DTR
46Anti Climbing devices (Barbed Wire) GS 2.24 mm Dia (14 SWG)
47Labour Charge for fixing of Anti Climbing devices (Barbed Wire) GS 2.24 mm Dia (14 SWG)
48Clamp for 140 KG PCC pole MS Flat 50x6 mm MS Flat ( 65x8 mm)
49Back Clamp for 140 KG Pcc Pole MS Flat ( 50x6 mm)
50Back Clamp for 280 KG Pcc Pole MS Flat ( 50x8 mm)
51Stone Block/Per cast block for base pedding(450x450x75mm)
52Back Filling of pole with boulders
53Concreting of structures & foundation (1:3:6)
54( Labour Charge) Concreting of structures & foundation (1:3:6)
55Concreting of stay (16 mm/12 mm) @0.2 Cmt. Per stay
56Labour Charge for Concreting of stay (16 mm/12 mm) @0.2 Cmt. Per stay
57Red oxide paint
58Labour Charge forRed oxide paint
59Aluminium paint
60Labour Charge for Aluminium paint
61M.S.Nuts and Bolts
62Danger Board Enamelled 11 KV
63Labour Charge forDanger Board Enamelled 11 KV
64Jointing sleeves suitable for rabbit (55 Sq.mmAl.Eq.) AAAc conductor
65Earthing of DTR As per G1 Schedule G1 for Black cotton soil
66Earthing for PCC pole4.00 mm 8 SWG G.I. wire 0.8 KG per pole
67Earthing Coil of 115 Turns of 50 MM Dia and 2.5 Mtr. Lead of 4.0 MM G.I. Wire
68M.S Strain Plat65x8 mm 250mm long
69Aluminium binding wire and tape
70SGST @ 9%
71CGST @ 9%