Tender For Repair And Maintenance To Apfc Panels And Connected Items At Niwaru Mil Stn Under Age (I) Niwaru, Jaipur-Rajasthan

Military Engineer Services-MES has published Tender For Repair And Maintenance To Apfc Panels And Connected Items At Niwaru Mil Stn Under Age (I) Niwaru. Submission Date for this Tender is 30-09-2023. Power Factor Panel Tenders in Jaipur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

39564804
Corrigendum : Tender For Repair And Maintenance To Apfc Panels And Connected Items At Niwaru Mil Stn Under Age (I) Niwaru
Open Tender
Indian
Rajasthan
Jaipur
30-09-2023

Tender Details

Tender For Repair And Maintenance To Apfc Panels And Connected Items At Niwaru Mil Stn Under Age ( I ) Niwaru

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 23-Sep-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 30-09-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 20000.0 /-
Tender Value
INR 9.99 Lakhs /-

BOQ Items

Name of Work: REPAIR AND MAINTENANCE TO APFC PANELS AND CONNECTED ITEMS AT NIWARU MIL STNUNDER AGE (I)NIWARU
Sl. No. Item Description
1M & L for shifting of APFC panel up to capacity of 170 KVAR from installed location to New location including dismentling and disconnecting LT cable, loading in vehicle carefully transporting to new location and installing to directed place approx 4 KM from old location to new location complete all as specified and directed and specified by Engineer-in-Charge. Note: If any type of damage accures during shifting the contractor will repair / replace the same free of cost.
2Supply, laying, connecting & testing of XLPE Insulated screened PVC bedded galvanized steel strip or wire armoured electric power, cable (heavy duty) with aluminum conductor, 1100 V grade cross sectional area 240 sqmm 3.5 core laying in trenches or passing through pipe/ on wallcomplete all as specified and directed by Engr-in-Charge. Note:- Old Unservisiblecable is under PCC Hardstanding hence old cable shall not be available for schedule of creditto contractor.
3Material& Labour for Chemical earthing complete with Pure copper earth plate electrode (98% conductivity when annealed) of size 900 mm x 600 mm x 5 mm thick buried directly in ground (earth pit not less than 4 m deep below normal ground level) with top edge of the plate not less than 2.5 m deep below normal ground connected to and including copper earth strip 32 mm x 6 mm by means of copper bolts nuts check nuts and washer, returning & filling the pit with excavated soil mixing with charcoal 250 KG, Crystal salt 200 KG, magnesium sulphate of 150 KG and vegetable soil all around the plate up to 350 mm above from top edge of plate and ballance portion filling with excavated soil in layers n.exc 25 mm thick,15 mm bore galvanised iron medium grade watering pipe, 40 mm bore galvanised iron light grade pipe for earth stripprotection, including all excavation earth work in any type of soil, PCC 1:3:6 type C1 for chamber of internal size 300 mm x 300 x300 mm with 120 mm thick wall and 700 mm x 700 mm x150 mm thick bed concrete, RCC 1:2:4,type B1, reinforced with welded steel wire fabric or XPM jali (weight not less than 4.00 Kg/Sqm)with cast iron frame, funnel with wire mesh, test point etc complete all as specified and directed. Note: (i) Copper Earth strip of size 32mm x 6 mm and GI protection pipe up to length 7.5m shall deemed to be included in rate of above item. (ii) The earth resistance value shall be less than 1 Ohm. Failing to achieve the value contractor shall re-do without any extra cost.
4M & L for dismentling old Cemented PCC duct / trunch cover and supply and fix in replacement mild steel Chequered plate having skid resistance property with distinctive raised marks on surface conforming to Grade E-165 (Fe29) fixed on cable duct in required size and shape having thicknees 2.5 mm to 6 mm as per direction and specificationn of Engineer-in-Charge. Note:- The sheet will be fixed in a manner that it will Carry at leat 100 Kg loadand will not loss on duct. shape will meet the duct size. Old broken PCC / Cement duct cover will be trown at leat 50 meter from installed location.
5M & L for Repair and preventive maintenance of APFC panel of any make and any stepup to capacity 170 KVAR by rewiring of circuit of APFC panel and making functional complete including calibration of relay, digital meter, cleaning with air blower all as specified and directed by engineer in charge testing complete. Note :Unserviceable Spare Part will be paid and measured separately under respective items of Schedule ‘A’.
6Supply and fix in replacement 3 phase Voltmeter with bright Red LED display 4 digits,0.1% Resolution, bright LED indicators for Kilo & Phase indication for measured value complete all as specified and directed by Engr in Charge.Make - Schneider model no DM 3210 referance 30002386 or equivalent
7Supply and fix in repair 3 phase Ammeter with bright Red LED display 4 digits,0.1% Resolution, bright LED indicators for Kilo & Phase indication for measured value complete all as specified and directed by Engr in Charge.Make - Schneider model no DM 3110 referance 30002385 or equivalent
8Supply and fixing in repair of power factorheavy duty series capacitor cylindrical type ISI mark, MMP,440V (AC) 3 phase, 50 Hz to APFC panel complete all as specified and directed by engineer in charge KVAR rating are as below :- make-EPCOS / Havells/ HPL/ L&T/ HAVELLS/ C&S/ABB
9(a) 1 KVAR
10(b) 2 KVAR
11(c) 5 KVAR
12(d) 10 KVAR
13(e) 15 KVAR
14(f) 25 KVAR
15Supply, installation, testing and commisioning in repair power factor relay (controller) upto 12 steps suitable forAPFC panel with programming complete including taking down the unserviceable power factor controller complete all as specified and directed. Make -: EPCOS model no BR6000 series 12 step relay 230 V code-B44066R6012R230, Phasetrac model No NAAC-3P or equivalent as per PS Note:- Relay will be same as per existing installed on site.
16Supply and fixingin replacement contactor for capacitor switching 3 pole AC operated for APFC panel 16 A Make- ABB cat part UA16-30-10RA or equivalent model in make C&S/ABB/Legrand/Havells
17Supply and fix in replacement cylindrical HRC fuse link fuse link 32Acomplete at APFC panel all as specified and directed by Engr in Charge.Make - C&S or equivalent /Legrand/Havells
18Supply and fix in replacement Red/Yellow/Blue LED indicating lamp (Set of three lamp), 240 volts, AC supply.
19Supply and fix in replacement cooling fan of APFC panel of suitable size as per site requirement with complete connection all as specified and directed by Engr in Charge.
20Supply, installation, testing and commisioning of Current transformer (CT) set of three with ratio 100/5 or 200/5Amp suitable for relay of APFC panel in repair complete all as specified and directed by engineer in charge make- alpha/EESMA or Equivalent as per PS
21Supply and fixing in replacement MCCB thermal magnetic type Ics=100%Icu adjustable overload setting 0.8 to 1.0 In of following capacity.
22(a) 4 Pole,415 V, 16-100 Amp.,andbreaking capacity of 16 to 18 KA
23(b) 4 Pole,415 V, 125 Amp.,andbreaking capacity of 16 to 18 KA
24(c) 4 Pole,415 V, 160 Amp.,andbreaking capacity of 25 KA
25(d) 4 Pole,415 V, 200 Amp.,andbreaking capacity of 25 KA
26(e) 4 Pole,415 V, 250 Amp.,andbreaking capacity of 25 KA
27(f) 4 Pole,415 V, 400 Amp.,andbreaking capacity of 25 KA
28Supply and fixing in repair 415V 10KA "C" curve MCB TP63 Amps with connection and testing complete all as directed by EIC.