| 1 | Attending of complaints pertaining tounsatisfactory/unfunctional state ofsolar water heater/ Geyser through telephone or in person on detailmentat MES Service centrefor Md/OTM accommodation in Hisar Mil Station byrectification of fault ofgeysers / solar water heater points complete and carrying outrepairsto the extent of disconnection and carefully taking down Geysers/faulty wires, sheet metal enclousers, switches & sockets, PVC Connection, conduits, boxes, main switches, MCBs, DBs heating elements, heating plate assembly, glasswool, thermostat, inner and outer tank and other E/M faults pertaining to particular instrument including wire upto 1.00 mtr and insulation tape required for the rectification of defect and refixing all serviceable/new electrical and mechanical items to existing/shifted location all specified by Engg-in-charge and make good for functional serviceability after repair / replacement of fixtures complete.Note:- 1.Contractor will provide one geyser/solar water heater mechanic and one helper for daily complaint except Sunday/Holidays 2. Penality will be charged @ 50 Rs per day on absent either mechanic/helper or Both. Note:- Cost of work requiring replacement of other stores will be measured as supply only and paid separately. Contractor shall provide the complaint slip containing 100 pages in duplicate (in two colour) of existingsize properly binded and printed all as per sample and directed by Engr-in-Charge. |
| 2 | M & L for taking out, rectify the faults such as brazing/soldering/welding and making tank leakproof and reinstalling the Solar Water Heater Water supply tanks and Metal frame work in-situ at specified locations with adequate concrete leg support as directed along with repair of water feeding pipe line connections as directed |
| 3 | M & L for descaling of Solar Water Heater header tanks and tubes of capacity 400 to 500 Ltr including taking down the tank and tubes, checking for leakages and rectification by suitable welding and descaling by using of descaling chemical and H2SO4 (as required) and rotatingthe chemical with the help of closed loop and water pressure pump to completely descale the tank and tubes and re-installing after testing and commissioning complete all as specified and directed. Note:- The work shall be carried out at the location of tank installed unless specified otherwise. |
| 4 | Supply and fixing in repairsof Solar Water Heater Tubes Model 58 / 1800mm suitable for 500 LPD capacitySolar Water Heater System, size of tube is 70mm(OD)x 58mm(ID)x2170mm(L)or as per existing and made out of copper/brass and includingwashers, tube caps complete all as specified and directed.Note:- Make of solar water tube shall be genuine and as per existing make. |
| 5 | Supply and fixing in repairs of Electrical back up of rating 4 KW heating element, single phase, with BSP of 1.1/4\" to in Solar Water Heaters 500/400 LPD capacity and including suitable connection wiring complete all as specified and directed. Note:- Make of electric back up shall be genuine and as per existing make. |
| 6 | Supply and fixing in repairs of temperature based automatic cut off Thermostat used in Electrical Back up of rating 4 KW BSP 1.1/4\" suitable for 500/100 LPD capacity Solar water heaters and including suitable connection wiring complete all as specified and directed. Note:- Make of thermostat shall be genuine and as per existing make. |
| 7 | Supply and fixing 500 Litre capacity Rotational moulded polyethylene water storage tanks (colour other than black as approved by Engineer-in-charge) triple layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I. |
| 8 | S & F in repairs of 20mm dia fancy type pillar tap cast copper alloy with capstan head, chromium plated, screwed down, high pressure with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe or for brass ferrule complete all as specified & directed. |
| 9 | S & F in repairs gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe, ISI marked and fixed of size 25mm bore dia complete all as specified and directed |
| 10 | S & F in repairs of gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe, ISI marked and fixed of size 20mm bore dia complete all as specified and directed. |
| 11 | S & F in repairs gun metal check valve / non return valve 15 mm dia suitable for Geyser of any make/capacity complete. All as specified and directed by Enge in charge. |
| 12 | Supply only pressure release valve 15mm dia suitabel for existing geysercomplete. |
| 13 | Supply only geyser heating element 1500 watt suitable for any type, size & make of geyser. All as specified and directed by Enge in charge. Make:Hincavo/SHBM/PNK Agency/PMW/Ultino-pro/ R AND I/ Swastik/Roshni/Litost/Airex/Generic/PMW |
| 14 | Supply only geyser heating element 2000 watt suitable for solar water heater of any type, size . All as specified and directed by Enge in charge. Make:Hincavo/SHBM/PNK Agency/PMW/Ultino-pro/ R AND I/ Swastik/Roshni/Litost/Airex/Genric/PMW |
| 15 | Supply onlythermostat of geyser suitable for any type, size & make of geyser as per existing range 15-75 degree temperature.Make: Powerpack/ Dasspass/Theeta |
| 16 | Supply only PVC Cable of size 2.50sqmm3 core copper conductor round type. |
| 17 | Supply onlyindicating lamp round typesuitable for Geyser any type, make & capacity |
| 18 | Supply onlystainless steel Heating plate assembly with water inlet & outlet, rubber gasket, nuts and bolts and washers of required size suitable for 50 Ltr Capacity Geyser of any type and make complete. |
| 19 | Supply only stainless steel Heating plate assembly with water inlet & outlet, rubber gasket, nuts and bolts and washers of required size suitable for 25 Ltr Capacity Geyser of any type and make complete. |
| 20 | Supply only glass wool for geyser vessel of any size and capacity complete. |
| 21 | Supply only mild steel holding/anchor bolts and nuts machine made of size 10cm to 15cm long and dia of bolt 10mm to 15mm complete.Note :- Anchor bolt shall be grouted with hammer drill only. |
| 22 | Supply onlydead nut/Safety plug of brass as per sample suitable for Geyser of any capacity/make. All as specified and directed by Enge in charge. |
| 23 | Supply only inner tank of geyser capacity 25 ltr made out of 16 SWG sheet Steel suitable for Geyser of any type and make to match the existing size and shape of inner tank of Geyser installed at site. All as specified and directed by Enge in charge. |
| 24 | All as per Srl item No 23 above but for Geyser of capacity 50 ltrs. All as specified and directed by Enge in charge. |
| 25 | Supply only outer tank of geyser made out of GI sheet of existing gauge, shapeincluding top and bottom cover plate complete suitable for inner tank 25 ltr capacity geyser of any make complete. All as specified and directed by Enge in charge. |
| 26 | All as per item No 25.00 but suitable for 50 ltr capacity geyser. All as specified and directed by Enge in charge. |
| 27 | Supply onlymetal clad plug Socket 20 Amp (enclosure type)suitable to fix in sheet and metal enclouser for geyser. All as specified and directed by Enge in charge.Make:-Havells/HPL/Benlo |
| 28 | Supply onlymetal clad plug top 20A (enclosure type)suitable to fix in sheet and metal enclouser for geyser. All as specified and directed by Enge in charge.Make:-Havells/HPL/Benlo |
| 29 | Supply only hot water PVC connection of15mm bore heavy duty, length upto 45cm with brass nut joints and washers at both ends complete. All as specified and directed by Enge in charge. |
| 30 | Supply only Cold water PVC connection of15mm bore heavy duty, length upto 45cm with brass nut joints and washers at both ends complete. All as specified and directed by Enge in charge. |
| 31 | Supply only sheet metal single pole and neutral enclosure with one SPN MCB of 20 Amp rating 240volt and a 2 pin and earth plug and socket complete all as specified and directed by Engg-in-charge. Make:L&T,Havells, Polycab,HPL,Benlo |
| 32 | Taking down unserviceable geysers 25/35/50 litre capacity of any make opening up for inspection, inlet, outlet and thermostat pipe, washing the inner tank with anti corrosion solution, the inlet & outlet valves, safety valve, dead weight and refixing the geysers in position and testing for proper functioning including soldering/welding where required to stop the leakage and other jobs connected with plumber and mason which would be required in connection with making the geyser functional complete. |
| 33 | Supply only MCB, SPN 32 AMP, 240V, 10 KA (B Curve) complete. All as specified and directed by Engg in charge.Make-L&T,Havells, Polycab,HPL,Benlo,Indo Asian |
| 34 | Supply only MCB, SP 20 AMP 240 V 10 KA (B Curve) complete. All as specified and directed by Engg in charge. Make-L&T,Havells, Polycab,HPL,Benlo,Indo Asian |
| 35 | Sub main wiring with 2 run of single core 6 Sqmm FRLS PVCinsulated unsheathed cable, 1100v grade with copper multi stranded conductordrawn through and including surfacePVC conduitISI marked medium grade 20mm dia with all fitting and fixing accessoriesincluding of 6 Sqmm FRLS PVC insulated unsheathed Copper cable green colour asearth wire connected to earth including taking down existing sub main wiring complete. |
| 36 | All as per serial item 35.00 here in before but with 2 run of single core 4 Sqmm cable with 4.0 sqmm earth wire. All as specified and directed by Enge in charge. |
| 37 | M&L for point wiring for one light point controlled by one, one way switch with 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including concealed PVC rigid non metallic conduit 20mm dia medium grade (ISI marked) with all fittings such as tees, bends etcincluding sunk type pressed steel box covered with and including 3 mm thick newbakelite laminated sheet top cover ‘Hylam’, complete, all as specified & directed. |
| 38 | M&L for point wiring for one light point controlled by one, one way switch with 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into existing PVC conduit / PVC casing caping concealed / fixed in wall or surface or ceiling including sunk type pressed steel box covered with and including 3 mm thick newbakelite laminated sheet top cover ‘Hylam’, complete, all as specified & directed. |
| 39 | Supply only plug top 15/16 Amp all as specified and directed. |
| 40 | Supply onlybottom split inspection cover for geyser of capacity 25 litres of any make. |
| 41 | Supply only bottom split inspection cover for geyser of capacity 50 litres of any make. |
| 42 | Supply only switch piano flush type, single pole, one way, 15/16 Amp, 230 Volts. |
| 43 | Supply onlyflush type socket outletmultipurpose 3 Pin 15/16 Amp (with 3 pin 5/6 Amp outlet also) 230 volts AC complete all as specified and directed. |
| 44 | Taking down carefully copper/aluminum point wiring (light/fan/socket or power) complete including taking out existing unserviceable terminal boxes & conduitwith switches/sockets/fan regulators and fittings such as ceiling rose, pendants, tube light fittings, lamp holders, brackets light fittings, rectangular blocks etc. and making good disturbed surface of walls, floors etc. to match with the existing surface etc complete all as specified and directed. |
| 45 | S&F in repairs galvanized steel water tubing medium grade of 25mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors all as specified and directed. Note: Cost of aluminium casing if required is also included in this item |
| 46 | S&F in repairs galvanized steel water tubing medium grade of 20mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors all as specified and directed.Note: Cost of aluminium casing if required is also included in this item |
| 47 | S&F in repairs galvanized steel water tubing medium grade of 15mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors all as specified and directed.Note: Cost of aluminium casing if required is also included in this item |