Urban Administration And Development-UAD has published Tender For Sub Station Balance Work Ward No.41 Ganiyari Pmay Awas. Submission Date for this Tender is 04-10-2023. Paver Blocking Tenders in singrauli Madhya Pradesh. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Non SOR item |
2 | Supply installation testing and fixing of hanging /tension type clamp with 4 no connector |
3 | L.T.DB box |
4 | Pole painting |
5 | Energy meter |
6 | Supply and fixing clamp Patti G.I. pipe 32m.m. dia band type and nut bolt |
7 | Supply & fixing LED street light 90 watt with ISI make |
8 | Guarding per one span |
9 | Anti climbing device (barbed wire 3.5 kg) GS 2.5m.m. dia (12SWG) |
10 | Bracing set for 8 feet (2.45 mtr.) center DP angle of 65x65x6 m.m. |
11 | ACSR Dog conductor 0.10 Sq. inch (100 Sq.mm. AL. EQ.) |
12 | Jointing sleeves (alluminium) for dog conductor |
13 | Stone block / RCC base plate size 450x450x75 m.m. (3no. per stay & 1no. per pole for base padding as per drawing no discom/EZ/47 & 48) |
14 | Fencing of S/S land with barbed wire (as per drawing no. misc 22) |
15 | MS sign board, bay indication board & RYB phase indication board (as per tender drawing no. misc-7) |
16 | Approach road (WBM) with hume pipe culvert (as per drawing no. misc-11,12 & 13) |
17 | Approach road (RCC with ratio- 1:2:4) from main gate to power transformer foundation, size-(20x3) mtr (as per drawing attached ) fro black soil |
18 | Approach road, made by 60mm. thick factory made cement concrete paver block of m-30 grade, along the cable trenches upto various equipements in the yard |
19 | Approach road (RCC with ratio- 1:2:4) from main gate to power transformer foundation, size-(20x3) mtr (as per drawing attached ) fro hard soil |
20 | 1000 liter P/F sintex overhead tank & GI pipe (with length of 125 mtrs) fitting for water supply including providing water tap(17no.) near transformer neutral earthing |
21 | Providing & fixing perforated cable tray 300 mm. wide & 2 mm. thick fixed on 45x45x5 mm. M.S. angle stand grouted in C.C. 1:24 as per drawing misc-8) |
22 | Cost of retaining wall 1.5 m. high as per site requirement |
23 | Providing and fixing earth pit of brick massonery 0.6 x 0.6 m. inner size with flag stone cover for watering system for 18 no earth pits |
24 | Fire detection equipment |
25 | PTR 33/11 KV of TC 5000KVA (Loss 5.5 + 33KW) |
26 | 11 KV VCB, outdoor porcelain clad type with complete structure and accessories |
27 | 11 KV CT outdoor type 300-150 / 5 amp |
28 | 11 KV control & relay panel with numerical static relay for transformer protection (1T) |
29 | 33 KV VCB, outdoor porcelain clad type with complete structure and accessories |
30 | 33 KV CT outdoor type 300-150 / 5 amp |
31 | 33 KV control & relay panel with static relay for feeder protection |
32 | 33 KV CT outdoor type 200-100/ 5-5 amp |
33 | 33 KV control & relay panel with numerical static relay for transformenr protection |
34 | 11KV CT outdoor type 200-100 / 5 amp |
35 | 11 KV control & relay panel with numerical static relay for double feeder protection (2F) |
36 | Lead acid battery set 30 volt 100 AH |
37 | Battery charger 230 V AC input 10 amp. 30 v DC output solid state type |
38 | 33 KV, isolator 600 amp, W/O earth switch TP gabg operated |
39 | 11 KV, isolator 800 amp. W/O earth switch TP gabg operated |
40 | 33 KV LA polymer type gapless/ metal oxide substation type |
41 | 11 KV LA polymer type gaples /metal oxide 9 KV 10 KA substation type |
42 | 33 KV/110 V 3P4W CT/PT ratio 400-200 /5 amp. outdoor oil immersed type |
43 | 33 KV single phase PTS oil immersed |
44 | 11 KV single phase PTS oil immersed |
45 | HT trivector energy meter, DLM compliant category-A (for substation /feeder metering), 3 phase 4 wire, 110 volts, 5 AMP, accuracy class 0.5 S with GSM (GPRS compatible ) modem |
46 | Sheet metal meter box suitable for H.T. static travector meters with TTB |
47 | DC distribution board with MCB |
48 | AC distribution board with MCB |
49 | Copper control cable 8 core, 2.5 sq.mm. PVC unarmoured |
50 | Copper control cable 4 core, 2.5 sq.mm. PVC unarmoured |
51 | Copper control cable 2 core, 2.5 sq.mm. PVC unarmoured |
52 | T clamp aluminum for bus bar panther run panther TAP |
53 | Bimetallic clamps for power transformer 11KV side |
54 | LT trivector energy meter, DLMS compliant category-A (for substation/ feeder metering), 3 phase 4 wire, 440 volts, 5 amp, accuracy class 0.5S with GSM (GPRS compatible) modem with Box |
55 | AAAC panther conductor 0.20 Sq. inch (200 Sq.mm. AL.EQ.) |
56 | Bracing set for 4 feet (1.2 mtr.) centre DP angle of 65x65x6 |
57 | DC cross arms 8’ (2.4 meter ) centre to centre 100x50x6 mm. channel |
58 | Rail 2 meter 52 KG/meter |
59 | PVC cable 2 core armoured 2.5 Sq.mm. aluminium conductor |
60 | PVC cable 4 core armoured 16 Sq.mm. aluminium conductor |
61 | Earthing for each sub-station |
62 | Earthing of transformer neutral with Two numbers 50x5 mm. copper strips, 3 Nos. 11 KV pin insulators mounted on 100x50 mm. MS channel support and AL. pad clamp with two bimetallic strips for twin panther conductor and AAACConductor |
63 | Chemical earthing at 33/11 KV S/S hardsoil min11 nos. of chemrod |
64 | Paiting of structures |
65 | 11KV 1500 KVAR auto switch capacitor bask including associated EQ such as 11KV VCB, control panel, 11 KV outdoor current X’mer with adequated metering & protection class of service, bus & EQ |
66 | D.C. channel 2.70 mtr. Long |
67 | D.C. channel 4.8 mtr. Centre 100x50x6mm. |
68 | 11 KV composite polymer strain set with hard ware suitable for panther conductor |
69 | Terminal clamps |
70 | Concreting (1:3:6) of foundation of VCB @3.5 CMT |
71 | Sheet metal meter box suitable forH.T. static travector meters with TTB |
72 | 33 KV composite polymer strain set with hard ware suitable for panther conductor |
73 | T clamp aluminum for bus bar panther run panther TAP |
74 | Concerting (1:3:6) of structure & foundation @ 0.5 CMT. Per structure |
75 | Piercing connector type-1, 1P/3P (main 16-50Sq.mm. Tap-off 16-50Sq.mm.) |
76 | Piercing connector type-II, (main 16-50Sq.mm. Tap-off 16-50Sq.mm.) |
77 | Stone block / RCC base plate size 450x450x75mm (3 no per stay & 1 no per pole for base padding as per drawing no. disc M/EZ/47 & 48 |
78 | Spring loaded busbar system suitable for 1 incoming 6 outgoing 1 phase circuit |
79 | Spring loaded busbar system suitable for 1 incoming 3 outgoing 3 phase circuit |
80 | 100 kVA, bis certified, level-II transformer |
81 | 11 KV, LA polymer type gapless /metal oxide 9 KV 5 KA line type |
82 | Transformer mounting channel 100x50x6mm. |
83 | Transformer clamping set 50x50x6mm. angle 460mm long |
84 | Transformer belting set 50x50x6mm. angle with two cross fixing channel |
85 | XLPE LT 1 - core aluminium unarmoured 70 sq.mm. cable |
86 | XLPE LT 1 - core aluminium unarmoured 150 sq.mm. cable |
87 | PTR 33/11 KV of TC 3150 KVA (Loss 3+15 KW) |
88 | PTR foundation as per attached drawing |
89 | 11 KV AB switch three phase 600 amp TP gang operated |
90 | 33 KV AB switch 600 amp TP gang operated |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy