Petroleum and Natural Gas Boards / Undertakings / PSU Closing in 0 days TDR #39551725

Tender For Real Time Energy Management System (Ems) To Monitor Critical Electrical Equipment Of Pump Stations And Power Consumption Of All Stations In Srpl

Issued by Boards / Undertakings / PSU · Chennai, Tamil Nadu
Tender Value
Ref. Documents
Estimated cost
Bid Submission
18 Sep 2023
0 days left
EMD
56400
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chennai → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Real Time Energy Management System (Ems) To Monitor Critical Electrical Equipment Of Pump Stations And Power Consumption Of All Stations In Srpl

BOQ

Name of Work: Real Time Energy Management System (EMS) to monitor critical electrical equipment of pump stations and power consumption of all stations in SRPL
Sl. No. Item Description
1GST % for the tender Please select the rate of GST in cell AY13. Rate selected shall be applicable for the entire BoQ.
2Centralized EMS Req. Chennai PS
3\"Supply and Installation of IOT Energy Gateway communication module with memory facility including at locations mentioned in scope of work\"
4Complete Software Integration - One time Engineering, Installation & Commissioning Charges for Software on-boarding, hardware configuration, account setup or any other charges.Remarks- 1.For 30 Gateways(DCUs), 185 Meters / VFDs/Process Controllers
5\"Software Cost with Lifetime License including Defect liability period of 12 months. Remarks- 1. For Server as well as Clients, Lump Sum. 2.There shall be 2 user credentials for each location and 3 user credentials at Chennai PS 3. Software shall include compliancetolatestISO standard,cyber security standard (latest edition) and 100% complaint to IT Policy.\"
6Supply ,Installation,testing and commissioning ofMeter having, True RM, Simultaneous Samplingof Volts & Amps, High Low recordingof VLL & VLN, V, A, Hz, W, VA, PF, Var Value, Harmonics individual and Total, Maximum Demand, Time of Use etc Storage with time stamp, field Programmable,Class 0.2, RS 485 series Channel Connection, Industry Standard Modbus, MODBUS RTU Protocol.
7\"Supply ,Installation,testing and commissioning ofMeter having, True RM, Simultaneous Samplingof Volts & Amps, High Low recordingof VLL & VLN, V, A, Hz, W, VA, PF, Var Value, Harmonics individual and Total, Storage with time stamp, field Programmable,Class 0.5, RS 485 series Channel Connection, Industry Standard Modbus, MODBUS RTU Protocol\"
8Supply and laying of 2CX1.5 sq.mm multi stranded copper conductors cable, twisted, shielded, FRLS sheathed, flexible armoured control cables with generally as specified andshall include the terminations .
9Supply and laying of LAN CAT VI Cable including termination .
10Module Interface Communication: Serial Interface communication module
11\"PLC System Modification:Manday Basis Modification work/Troubleshooting wrok in PLC System logic/ SCC HMI screens etc.\"
12\"Centralized Server with intel Core i9 processor, 1TB HDD + 512 GB SSD, 16 GB RAM with FHD LED 22-24 inch monitor with suitable OS
13BOQ at SRPL Chengalpet for EMS
14\"Supply and Installation of IOT Energy Gateway communication module with memory facility including at locations mentioned in scope of work\"
15Supply ,Installation,testing and commissioning ofMeter having, True RM, Simultaneous Samplingof Volts & Amps, High Low recordingof VLL & VLN, V, A, Hz, W, VA, PF, Var Value, Harmonics individual and Total, Maximum Demand, Time of Use etc Storage with time stamp, field Programmable,Class 0.2, RS 485 series Channel Connection, Industry Standard Modbus, MODBUS RTU Protocol.
16Supply and laying of 2CX1.5 sq.mm multi stranded copper conductors cable, twisted, shielded, FRLS sheathed, flexible armoured control cables with generally as specified andshall include the terminations .
17Supply and laying of LAN CAT VI Cable including termination .
18Module Interface Communication: Serial Interface communication module
19\"PLC System Modification:Manday Basis Modification work/Troubleshooting wrok in PLC System logic/ SCC HMI screens etc.\"
20BOQ at SRPL Asanur for EMS
21\"Supply and Installation of IOT Energy Gateway communication module with memory facility including at locations mentioned in scope of work\"
22Supply ,Installation,testing and commissioning ofMeter having, True RM, Simultaneous Samplingof Volts & Amps, High Low recordingof VLL & VLN, V, A, Hz, W, VA, PF, Var Value, Harmonics individual and Total, Maximum Demand, Time of Use etc Storage with time stamp, field Programmable,Class 0.2, RS 485 series Channel Connection, Industry Standard Modbus, MODBUS RTU Protocol.
23Supply and laying of 2CX1.5 sq.mm multi stranded copper conductors cable, twisted, shielded, FRLS sheathed, flexible armoured control cables with generally as specified andshall include the terminations .
24Supply and laying of LAN CAT VI Cable including termination .
25Module Interface Communication: Serial Interface communication module
26\"PLC System Modification:Manday Basis Modification work/Troubleshooting wrok in PLC System logic/ SCC HMI screens etc.\"
27BOQ at SRPL Trichy for EMS
28\"Supply and Installation of IOT Energy Gateway communication module with memory facility including at locations mentioned in scope of work\"
29Supply ,Installation,testing and commissioning ofMeter having, True RM, Simultaneous Samplingof Volts & Amps, High Low recordingof VLL & VLN, V, A, Hz, W, VA, PF, Var Value, Harmonics individual and Total, Maximum Demand, Time of Use etc Storage with time stamp, field Programmable,Class 0.2, RS 485 series Channel Connection, Industry Standard Modbus, MODBUS RTU Protocol.
30Supply and laying of 2CX1.5 sq.mm multi stranded copper conductors cable, twisted, shielded, FRLS sheathed, flexible armoured control cables with generally as specified andshall include the terminations .
31Supply and laying of LAN CAT VI Cable including termination .
32Module Interface Communication: Serial Interface communication module
33\"PLC System Modification:Manday Basis Modification work/Troubleshooting wrok in PLC System logic/ SCC HMI screens etc.\"
34BOQ at SRPL chittoor for EMS
35\"Supply and Installation of IOT Energy Gateway communication module with memory facility including at locations mentioned in scope of work\"
36Supply ,Installation,testing and commissioning ofMeter having, True RM, Simultaneous Samplingof Volts & Amps, High Low recordingof VLL & VLN, V, A, Hz, W, VA, PF, Var Value, Harmonics individual and Total, Maximum Demand, Time of Use etc Storage with time stamp, field Programmable,Class 0.2, RS 485 series Channel Connection, Industry Standard Modbus, MODBUS RTU Protocol.
37Supply and laying of 2CX1.5 sq.mm multi stranded copper conductors cable, twisted, shielded, FRLS sheathed, flexible armoured control cables with generally as specified andshall include the terminations .
38Supply and laying of LAN CAT VI Cable including termination .
39Module Interface Communication: Serial Interface communication module
40\"PLC System Modification:Manday Basis Modification work/Troubleshooting wrok in PLC System logic/ SCC HMI screens etc.\"
41BOQ at SRPL Bengaluru for EMS
42\"Supply and Installation of IOT Energy Gateway communication module with memory facility including at locations mentioned in scope of work\"
43Supply ,Installation,testing and commissioning ofMeter having, True RM, Simultaneous Samplingof Volts & Amps, High Low recordingof VLL & VLN, V, A, Hz, W, VA, PF, Var Value, Harmonics individual and Total, Maximum Demand, Time of Use etc Storage with time stamp, field Programmable,Class 0.2, RS 485 series Channel Connection, Industry Standard Modbus, MODBUS RTU Protocol.
44\"Supply ,Installation,testing and commissioning ofMeter having, True RM, Simultaneous Samplingof Volts & Amps, High Low recordingof VLL & VLN, V, A, Hz, W, VA, PF, Var Value, Harmonics individual and Total, Storage with time stamp, field Programmable,Class 0.5, RS 485 series Channel Connection, Industry Standard Modbus, MODBUS RTU Protocol\"
45Supply and laying of 2CX1.5 sq.mm multi stranded copper conductors cable, twisted, shielded, FRLS sheathed, flexible armoured control cables with generally as specified andshall include the terminations .
46Supply and laying of LAN CAT VI Cable including termination .
47Module Interface Communication: Serial Interface communication module
48\"PLC System Modification:Manday Basis Modification work/Troubleshooting wrok in PLC System logic/ SCC HMI screens etc.\"
49BOQ at SRPL Madurai for EMS
50\"Supply and Installation of IOT Energy Gateway communication module with memory facility including at locations mentioned in scope of work\"
51Supply ,Installation,testing and commissioning ofMeter having, True RM, Simultaneous Samplingof Volts & Amps, High Low recordingof VLL & VLN, V, A, Hz, W, VA, PF, Var Value, Harmonics individual and Total, Maximum Demand, Time of Use etc Storage with time stamp, field Programmable,Class 0.2, RS 485 series Channel Connection, Industry Standard Modbus, MODBUS RTU Protocol.
52\"Supply ,Installation,testing and commissioning ofMeter having, True RM, Simultaneous Samplingof Volts & Amps, High Low recordingof VLL & VLN, V, A, Hz, W, VA, PF, Var Value, Harmonics individual and Total, Storage with time stamp, field Programmable,Class 0.5, RS 485 series Channel Connection, Industry Standard Modbus, MODBUS RTU Protocol\"
53Supply and laying of 2CX1.5 sq.mm multi stranded copper conductors cable, twisted, shielded, FRLS sheathed, flexible armoured control cables with generally as specified andshall include the terminations .
54Supply and laying of LAN CAT VI Cable including termination .
55Module Interface Communication: Serial Interface communication module
56\"PLC System Modification:Manday Basis Modification work/Troubleshooting wrok in PLC System logic/ SCC HMI screens etc.\"
57BOQ at SRPL Sankari for EMS
58\"Supply and Installation of IOT Energy Gateway communication module with memory facility including at locations mentioned in scope of work\"
59Supply ,Installation,testing and commissioning ofMeter having, True RM, Simultaneous Samplingof Volts & Amps, High Low recordingof VLL & VLN, V, A, Hz, W, VA, PF, Var Value, Harmonics individual and Total, Maximum Demand, Time of Use etc Storage with time stamp, field Programmable,Class 0.2, RS 485 series Channel Connection, Industry Standard Modbus, MODBUS RTU Protocol.
60\"Supply ,Installation,testing and commissioning ofMeter having, True RM, Simultaneous Samplingof Volts & Amps, High Low recordingof VLL & VLN, V, A, Hz, W, VA, PF, Var Value, Harmonics individual and Total, Storage with time stamp, field Programmable,Class 0.5, RS 485 series Channel Connection, Industry Standard Modbus, MODBUS RTU Protocol\"
61Supply and laying of 2CX1.5 sq.mm multi stranded copper conductors cable, twisted, shielded, FRLS sheathed, flexible armoured control cables with generally as specified andshall include the terminations .
62Supply and laying of LAN CAT VI Cable including termination .
63Module Interface Communication: Serial Interface communication module
64\"PLC System Modification:Manday Basis Modification work/Troubleshooting wrok in PLC System logic/ SCC HMI screens etc.\"
65BOQ at SRPL Ennore for EMS
66\"Supply and Installation of IOT Energy Gateway communication module with memory facility including at locations mentioned in scope of work\"
67Supply ,Installation,testing and commissioning ofMeter having, True RM, Simultaneous Samplingof Volts & Amps, High Low recordingof VLL & VLN, V, A, Hz, W, VA, PF, Var Value, Harmonics individual and Total, Maximum Demand, Time of Use etc Storage with time stamp, field Programmable,Class 0.2, RS 485 series Channel Connection, Industry Standard Modbus, MODBUS RTU Protocol.
68\"Supply ,Installation,testing and commissioning ofMeter having, True RM, Simultaneous Samplingof Volts & Amps, High Low recordingof VLL & VLN, V, A, Hz, W, VA, PF, Var Value, Harmonics individual and Total, Storage with time stamp, field Programmable,Class 0.5, RS 485 series Channel Connection, Industry Standard Modbus, MODBUS RTU Protocol\"
69Supply and laying of 2CX1.5 sq.mm multi stranded copper conductors cable, twisted, shielded, FRLS sheathed, flexible armoured control cables with generally as specified andshall include the terminations .
70Supply and laying of LAN CAT VI Cable including termination .
71Module Interface Communication: Serial Interface communication module
72\"PLC System Modification:Manday Basis Modification work/Troubleshooting wrok in PLC System logic/ SCC HMI screens etc.\"
73BOQ at SRPL Ramanathapuram for EMS
74\"Supply and Installation of IOT Energy Gateway communication module with memory facility including at locations mentioned in scope of work\"
75Supply and laying of 2CX1.5 sq.mm multi stranded copper conductors cable, twisted, shielded, FRLS sheathed, flexible armoured control cables with generally as specified andshall include the terminations .
76Supply and laying of LAN CAT VI Cable including termination .
77Module Interface Communication: Serial Interface communication module
78\"PLC System Modification:Manday Basis Modification work/Troubleshooting wrok in PLC System logic/ SCC HMI screens etc.\"
79Supply ,Installation,testing and commissioning ofMeter having, True RM, Simultaneous Samplingof Volts & Amps, High Low recordingof VLL & VLN, V, A, Hz, W, VA, PF, Var Value, Harmonics individual and Total, Maximum Demand, Time of Use etc Storage with time stamp, field Programmable,Class 0.2, RS 485 series Channel Connection, Industry Standard Modbus, MODBUS RTU Protocol.
80Complete software Annual maintenance con
81Complete software Annual maintenance contract and upgradation for 2nd to 5th year. Which implies quick response and rectification of any trouble in software during AMC period occurring due to any kind of problem in Software as well as hardware.

AI Tender Summary

OUR REF NO 39551725
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 18-09-2023
Authority
Authority Name Indian Oil Corporation Limited
Work Description Tender For Real Time Energy Management System (Ems) To Monitor Critical Electrical Equipment Of Pump Stations And Power Consumption Of All Stations In Srpl
Basic Detail
Tender No SRPL23C020
Bidding Type Tender
Location
City Chennai
State Tamil Nadu
Key Dates
Publish Date 08 Sep 2023
Submission Date 18 Sep 2023
Open Date 19 Sep 2023
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 56400
Exemption Not Available
Document List
BOQ_180861.xls
FAQs-IOCL-Online-EMD.pdf
Special_Instructions_to_t.pdf
SRPL23C020.pdf
Tender-Acceptance-Format.pdf
Tendernotice_1.pdf
1cd1698d-2a7c-4143-86a7-1fc00518e534.html
Addendum_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 08, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 18, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Sep 19, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
xls

BOQ_180861.xls

pdf

FAQs-IOCL-Online-EMD.pdf

pdf

Special_Instructions_to_t.pdf

pdf

SRPL23C020.pdf

pdf

Tender-Acceptance-Format.pdf

pdf

Tendernotice_1.pdf

html

1cd1698d-2a7c-4143-86a7-1fc00518e534.html

pdf

Addendum_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender