Tender For Real Time Energy Management System (Ems) To Monitor Critical Electrical Equipment Of Pump Stations And Power Consumption Of All Stations In Srpl
Tender Value
Ref. Documents
Estimated cost
Bid Submission
18 Sep 2023
0 days left
EMD
56400
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chennai → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Real Time Energy Management System (Ems) To Monitor Critical Electrical Equipment Of Pump Stations And Power Consumption Of All Stations In Srpl
BOQ
| Sl. No. | Item Description |
| 1 | GST % for the tender Please select the rate of GST in cell AY13. Rate selected shall be applicable for the entire BoQ. |
| 2 | Centralized EMS Req. Chennai PS |
| 3 | \"Supply and Installation of IOT Energy Gateway communication module with memory facility including at locations mentioned in scope of work\" |
| 4 | Complete Software Integration - One time Engineering, Installation & Commissioning Charges for Software on-boarding, hardware configuration, account setup or any other charges.Remarks- 1.For 30 Gateways(DCUs), 185 Meters / VFDs/Process Controllers |
| 5 | \"Software Cost with Lifetime License including Defect liability period of 12 months. Remarks- 1. For Server as well as Clients, Lump Sum. 2.There shall be 2 user credentials for each location and 3 user credentials at Chennai PS 3. Software shall include compliancetolatestISO standard,cyber security standard (latest edition) and 100% complaint to IT Policy.\" |
| 6 | Supply ,Installation,testing and commissioning ofMeter having, True RM, Simultaneous Samplingof Volts & Amps, High Low recordingof VLL & VLN, V, A, Hz, W, VA, PF, Var Value, Harmonics individual and Total, Maximum Demand, Time of Use etc Storage with time stamp, field Programmable,Class 0.2, RS 485 series Channel Connection, Industry Standard Modbus, MODBUS RTU Protocol. |
| 7 | \"Supply ,Installation,testing and commissioning ofMeter having, True RM, Simultaneous Samplingof Volts & Amps, High Low recordingof VLL & VLN, V, A, Hz, W, VA, PF, Var Value, Harmonics individual and Total, Storage with time stamp, field Programmable,Class 0.5, RS 485 series Channel Connection, Industry Standard Modbus, MODBUS RTU Protocol\" |
| 8 | Supply and laying of 2CX1.5 sq.mm multi stranded copper conductors cable, twisted, shielded, FRLS sheathed, flexible armoured control cables with generally as specified andshall include the terminations . |
| 9 | Supply and laying of LAN CAT VI Cable including termination . |
| 10 | Module Interface Communication: Serial Interface communication module |
| 11 | \"PLC System Modification:Manday Basis Modification work/Troubleshooting wrok in PLC System logic/ SCC HMI screens etc.\" |
| 12 | \"Centralized Server with intel Core i9 processor, 1TB HDD + 512 GB SSD, 16 GB RAM with FHD LED 22-24 inch monitor with suitable OS |
| 13 | BOQ at SRPL Chengalpet for EMS |
| 14 | \"Supply and Installation of IOT Energy Gateway communication module with memory facility including at locations mentioned in scope of work\" |
| 15 | Supply ,Installation,testing and commissioning ofMeter having, True RM, Simultaneous Samplingof Volts & Amps, High Low recordingof VLL & VLN, V, A, Hz, W, VA, PF, Var Value, Harmonics individual and Total, Maximum Demand, Time of Use etc Storage with time stamp, field Programmable,Class 0.2, RS 485 series Channel Connection, Industry Standard Modbus, MODBUS RTU Protocol. |
| 16 | Supply and laying of 2CX1.5 sq.mm multi stranded copper conductors cable, twisted, shielded, FRLS sheathed, flexible armoured control cables with generally as specified andshall include the terminations . |
| 17 | Supply and laying of LAN CAT VI Cable including termination . |
| 18 | Module Interface Communication: Serial Interface communication module |
| 19 | \"PLC System Modification:Manday Basis Modification work/Troubleshooting wrok in PLC System logic/ SCC HMI screens etc.\" |
| 20 | BOQ at SRPL Asanur for EMS |
| 21 | \"Supply and Installation of IOT Energy Gateway communication module with memory facility including at locations mentioned in scope of work\" |
| 22 | Supply ,Installation,testing and commissioning ofMeter having, True RM, Simultaneous Samplingof Volts & Amps, High Low recordingof VLL & VLN, V, A, Hz, W, VA, PF, Var Value, Harmonics individual and Total, Maximum Demand, Time of Use etc Storage with time stamp, field Programmable,Class 0.2, RS 485 series Channel Connection, Industry Standard Modbus, MODBUS RTU Protocol. |
| 23 | Supply and laying of 2CX1.5 sq.mm multi stranded copper conductors cable, twisted, shielded, FRLS sheathed, flexible armoured control cables with generally as specified andshall include the terminations . |
| 24 | Supply and laying of LAN CAT VI Cable including termination . |
| 25 | Module Interface Communication: Serial Interface communication module |
| 26 | \"PLC System Modification:Manday Basis Modification work/Troubleshooting wrok in PLC System logic/ SCC HMI screens etc.\" |
| 27 | BOQ at SRPL Trichy for EMS |
| 28 | \"Supply and Installation of IOT Energy Gateway communication module with memory facility including at locations mentioned in scope of work\" |
| 29 | Supply ,Installation,testing and commissioning ofMeter having, True RM, Simultaneous Samplingof Volts & Amps, High Low recordingof VLL & VLN, V, A, Hz, W, VA, PF, Var Value, Harmonics individual and Total, Maximum Demand, Time of Use etc Storage with time stamp, field Programmable,Class 0.2, RS 485 series Channel Connection, Industry Standard Modbus, MODBUS RTU Protocol. |
| 30 | Supply and laying of 2CX1.5 sq.mm multi stranded copper conductors cable, twisted, shielded, FRLS sheathed, flexible armoured control cables with generally as specified andshall include the terminations . |
| 31 | Supply and laying of LAN CAT VI Cable including termination . |
| 32 | Module Interface Communication: Serial Interface communication module |
| 33 | \"PLC System Modification:Manday Basis Modification work/Troubleshooting wrok in PLC System logic/ SCC HMI screens etc.\" |
| 34 | BOQ at SRPL chittoor for EMS |
| 35 | \"Supply and Installation of IOT Energy Gateway communication module with memory facility including at locations mentioned in scope of work\" |
| 36 | Supply ,Installation,testing and commissioning ofMeter having, True RM, Simultaneous Samplingof Volts & Amps, High Low recordingof VLL & VLN, V, A, Hz, W, VA, PF, Var Value, Harmonics individual and Total, Maximum Demand, Time of Use etc Storage with time stamp, field Programmable,Class 0.2, RS 485 series Channel Connection, Industry Standard Modbus, MODBUS RTU Protocol. |
| 37 | Supply and laying of 2CX1.5 sq.mm multi stranded copper conductors cable, twisted, shielded, FRLS sheathed, flexible armoured control cables with generally as specified andshall include the terminations . |
| 38 | Supply and laying of LAN CAT VI Cable including termination . |
| 39 | Module Interface Communication: Serial Interface communication module |
| 40 | \"PLC System Modification:Manday Basis Modification work/Troubleshooting wrok in PLC System logic/ SCC HMI screens etc.\" |
| 41 | BOQ at SRPL Bengaluru for EMS |
| 42 | \"Supply and Installation of IOT Energy Gateway communication module with memory facility including at locations mentioned in scope of work\" |
| 43 | Supply ,Installation,testing and commissioning ofMeter having, True RM, Simultaneous Samplingof Volts & Amps, High Low recordingof VLL & VLN, V, A, Hz, W, VA, PF, Var Value, Harmonics individual and Total, Maximum Demand, Time of Use etc Storage with time stamp, field Programmable,Class 0.2, RS 485 series Channel Connection, Industry Standard Modbus, MODBUS RTU Protocol. |
| 44 | \"Supply ,Installation,testing and commissioning ofMeter having, True RM, Simultaneous Samplingof Volts & Amps, High Low recordingof VLL & VLN, V, A, Hz, W, VA, PF, Var Value, Harmonics individual and Total, Storage with time stamp, field Programmable,Class 0.5, RS 485 series Channel Connection, Industry Standard Modbus, MODBUS RTU Protocol\" |
| 45 | Supply and laying of 2CX1.5 sq.mm multi stranded copper conductors cable, twisted, shielded, FRLS sheathed, flexible armoured control cables with generally as specified andshall include the terminations . |
| 46 | Supply and laying of LAN CAT VI Cable including termination . |
| 47 | Module Interface Communication: Serial Interface communication module |
| 48 | \"PLC System Modification:Manday Basis Modification work/Troubleshooting wrok in PLC System logic/ SCC HMI screens etc.\" |
| 49 | BOQ at SRPL Madurai for EMS |
| 50 | \"Supply and Installation of IOT Energy Gateway communication module with memory facility including at locations mentioned in scope of work\" |
| 51 | Supply ,Installation,testing and commissioning ofMeter having, True RM, Simultaneous Samplingof Volts & Amps, High Low recordingof VLL & VLN, V, A, Hz, W, VA, PF, Var Value, Harmonics individual and Total, Maximum Demand, Time of Use etc Storage with time stamp, field Programmable,Class 0.2, RS 485 series Channel Connection, Industry Standard Modbus, MODBUS RTU Protocol. |
| 52 | \"Supply ,Installation,testing and commissioning ofMeter having, True RM, Simultaneous Samplingof Volts & Amps, High Low recordingof VLL & VLN, V, A, Hz, W, VA, PF, Var Value, Harmonics individual and Total, Storage with time stamp, field Programmable,Class 0.5, RS 485 series Channel Connection, Industry Standard Modbus, MODBUS RTU Protocol\" |
| 53 | Supply and laying of 2CX1.5 sq.mm multi stranded copper conductors cable, twisted, shielded, FRLS sheathed, flexible armoured control cables with generally as specified andshall include the terminations . |
| 54 | Supply and laying of LAN CAT VI Cable including termination . |
| 55 | Module Interface Communication: Serial Interface communication module |
| 56 | \"PLC System Modification:Manday Basis Modification work/Troubleshooting wrok in PLC System logic/ SCC HMI screens etc.\" |
| 57 | BOQ at SRPL Sankari for EMS |
| 58 | \"Supply and Installation of IOT Energy Gateway communication module with memory facility including at locations mentioned in scope of work\" |
| 59 | Supply ,Installation,testing and commissioning ofMeter having, True RM, Simultaneous Samplingof Volts & Amps, High Low recordingof VLL & VLN, V, A, Hz, W, VA, PF, Var Value, Harmonics individual and Total, Maximum Demand, Time of Use etc Storage with time stamp, field Programmable,Class 0.2, RS 485 series Channel Connection, Industry Standard Modbus, MODBUS RTU Protocol. |
| 60 | \"Supply ,Installation,testing and commissioning ofMeter having, True RM, Simultaneous Samplingof Volts & Amps, High Low recordingof VLL & VLN, V, A, Hz, W, VA, PF, Var Value, Harmonics individual and Total, Storage with time stamp, field Programmable,Class 0.5, RS 485 series Channel Connection, Industry Standard Modbus, MODBUS RTU Protocol\" |
| 61 | Supply and laying of 2CX1.5 sq.mm multi stranded copper conductors cable, twisted, shielded, FRLS sheathed, flexible armoured control cables with generally as specified andshall include the terminations . |
| 62 | Supply and laying of LAN CAT VI Cable including termination . |
| 63 | Module Interface Communication: Serial Interface communication module |
| 64 | \"PLC System Modification:Manday Basis Modification work/Troubleshooting wrok in PLC System logic/ SCC HMI screens etc.\" |
| 65 | BOQ at SRPL Ennore for EMS |
| 66 | \"Supply and Installation of IOT Energy Gateway communication module with memory facility including at locations mentioned in scope of work\" |
| 67 | Supply ,Installation,testing and commissioning ofMeter having, True RM, Simultaneous Samplingof Volts & Amps, High Low recordingof VLL & VLN, V, A, Hz, W, VA, PF, Var Value, Harmonics individual and Total, Maximum Demand, Time of Use etc Storage with time stamp, field Programmable,Class 0.2, RS 485 series Channel Connection, Industry Standard Modbus, MODBUS RTU Protocol. |
| 68 | \"Supply ,Installation,testing and commissioning ofMeter having, True RM, Simultaneous Samplingof Volts & Amps, High Low recordingof VLL & VLN, V, A, Hz, W, VA, PF, Var Value, Harmonics individual and Total, Storage with time stamp, field Programmable,Class 0.5, RS 485 series Channel Connection, Industry Standard Modbus, MODBUS RTU Protocol\" |
| 69 | Supply and laying of 2CX1.5 sq.mm multi stranded copper conductors cable, twisted, shielded, FRLS sheathed, flexible armoured control cables with generally as specified andshall include the terminations . |
| 70 | Supply and laying of LAN CAT VI Cable including termination . |
| 71 | Module Interface Communication: Serial Interface communication module |
| 72 | \"PLC System Modification:Manday Basis Modification work/Troubleshooting wrok in PLC System logic/ SCC HMI screens etc.\" |
| 73 | BOQ at SRPL Ramanathapuram for EMS |
| 74 | \"Supply and Installation of IOT Energy Gateway communication module with memory facility including at locations mentioned in scope of work\" |
| 75 | Supply and laying of 2CX1.5 sq.mm multi stranded copper conductors cable, twisted, shielded, FRLS sheathed, flexible armoured control cables with generally as specified andshall include the terminations . |
| 76 | Supply and laying of LAN CAT VI Cable including termination . |
| 77 | Module Interface Communication: Serial Interface communication module |
| 78 | \"PLC System Modification:Manday Basis Modification work/Troubleshooting wrok in PLC System logic/ SCC HMI screens etc.\" |
| 79 | Supply ,Installation,testing and commissioning ofMeter having, True RM, Simultaneous Samplingof Volts & Amps, High Low recordingof VLL & VLN, V, A, Hz, W, VA, PF, Var Value, Harmonics individual and Total, Maximum Demand, Time of Use etc Storage with time stamp, field Programmable,Class 0.2, RS 485 series Channel Connection, Industry Standard Modbus, MODBUS RTU Protocol. |
| 80 | Complete software Annual maintenance con |
| 81 | Complete software Annual maintenance contract and upgradation for 2nd to 5th year. Which implies quick response and rectification of any trouble in software during AMC period occurring due to any kind of problem in Software as well as hardware. |
AI Tender Summary
Tender Timeline
Sep 08, 2023
11:30 IST
Tender Published
Tender notice published.
CompletedSep 18, 2023
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedSep 19, 2023
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender