Municipal Corporation Of Delhi has published Tender For Improvement/Devlopment Of Ei & Other Allied Works In A-Block Jwalapuri Polyclinic Ward No-45 Under Rohini Zone. Submission Date for this Tender is 13-09-2023. Electrical Maintenance Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | OD7705/2023-2024:SR 22 (1.17.15) S/D following size of FR PVC insulated copper conductor 1 core cable in existing surface/recessed /PVC/ Steel conduitas reqd. 6 x 2.5 sq mm |
2 | OD7706/2023-2024:SR 22 (1.17.21) S/D following size of FR PVC insulated copper conductor 1 core cable in existing surface/recessed /PVC/ Steel conduitas reqd. 3 x 4 sq mm |
3 | OD7707/2023-2024:SR 22 (1.17.30) S/D following size of FR PVC insulated copper conductor 1 core cable in existing surface/recessed /PVC/ Steel conduitas reqd. 3 x 6 sq mm |
4 | OD7708/2023-2024:SR 22 (1.32) Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
5 | OD7709/2023-2024:SR 22 (5.1)Earthing with GI Earth pipe 4.5longx40mm dia i/c accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc (but without charcoal or coke and salt) complete as required. |
6 | OD7710/2023-2024:SR 22 (2.12.2)Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps |
7 | OD7711/2023-2024:SR 22 (2.10.1)Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.. Single Pole |
8 | OD7713/2023-2024:SR 22 (7.6.1)Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm |
9 | OD7715/2023-2024:SR 22 (7.7)Laying of one no PVC insulated and PVC sheathed/XPLE Al Conductor armoured power cable of 1.1KV grade of following sizeon wall surface as required. Up to 35 sq,mm (clamped with 1mm thick saddle) |
10 | OD7716/2023-2024:SR 22 (5.15)Providing and fixing 25mm x 5mm GI strip on surface or in recess for connections etc as reqd |
11 | OD7922/2023-2024:Supply of 15"(380mm) 1400rpmsweep exhaust fan heavy duty complete with blades, shutter etc as required |
12 | OD7623/2023-2024:SR 22 (1.15.3)Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable and 1.5 sq.mm. FR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. Group C |
13 | OD7624/2023-2024:SR 22( 1.8.3) Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as redq. Group C |
14 | OD7697/2023-2024:SR 22 (1.17.12 ) S/D following size of FR PVC insulated copper conductor 1 core cable in existing surface/recessed /PVC/ Steel conduitas reqd. 3 x 2.5 sq mm |
15 | OD7698/2023-2024:SR 22 (1.20.2 )Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface / recessed including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
16 | OD7699/2023-2024:SR 22 (1.24.4) Supplying and fixing followingModular switch/ socket on the existing Modular Plate & switch box/ cover including connections etc. as required. 3 Pin 5/6 amp socket |
17 | OD7700/2023-2024:SR 22 (1.24.1) Supplying and fixing followingModular switch/ socket on the existing Modular Plate & switch box/ cover including connections etc. as required. 5/6 amp switch |
18 | OD7728/2023-2024:SR 22 (2.2.14) Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 125 A 36 KA MCCB |
19 | OD7729/2023-2024:SR 22 (1.50.1) Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep |
20 | OD7730/2023-2024:SR 22 (1.58) Supplying and fixing PVC Batten/ Angle Holder including connection etc. as required. |
21 | OD7731/2023-2024:SR 22 (1.38)Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. |
22 | 122.1.3:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*10 sqmm |
23 | 122.1.42:Supply of 14/15 Watt LED retrofit lamp suitable for B22 holder |
24 | 122.2.2: P/FHot press sheet mouldedcompound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof polebox of innerdimension 200x160x98mm (NS) complete with suitable arrangement for fixing of 2 nosof 6 to 32 amp single pole MCB & 63 Amp. Doublepole isolator (MCB/Isolator excluded) withneutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plateofsuitable size with danger monogram property printed on the coveretc asreqd. asreqd. |
25 | 122.2.30.a:SITC of 150W LED Flood Light luminaire fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =150 watt +/- 5% (b) Luminaire Efficacy>=100 Lm/w (c) Power Factor>=0.95 (d) Protection Class- IP-66 |
26 | 122.2.38:S/I/T/C of Surface mounting CRCA housing 36W LED luminaire with acrylic cover diffuser with following specifications including fixing on existing wall/recess with connections as reqd. (a)Total system wattage = 36 watt +/- 5% (b )Luminous efficacy >=95 lumens /watt. (c)Power factor >=0.95 |
27 | 122.2.39:S/I/T/C of LED Tube type luminaire 20 Watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following:(a) Total system wattage 20 watt +/- 5%(b )Luminous efficacy lumens/watt >=95 (c)Power Factor >=0.95 |
28 | 122.2.113:S/I/T/C of 2 TR, 2 star/3 star, window air conditioner having copper condenser coil, rotary compressor and R32/better refrigerant. |
29 | 122.2.115:S/I/T/C of 4 KVA Voltage Stabilizer having input voltage 150V-270V and output voltage 195-245V |
30 | 122.2.156.(a):P&F following sizes of PVC insulated & PVC sheathed copper conductor 3 core submersible cable confirming to IS.694/1990 etc. as reqd. 3x 2.5 sq.mm |
31 | 122.2.154B.(a):Supplying, lowering, testing and commissioning of vertical type, multistage, totally enclosed water filled deep well submersible pumping set complete i/c connection etc. as reqd. Single Phase 1.5 HP having discharge of 72 LPM Approx. at 49 M Head. |
32 | OD7802/2023-2024:SR 22 (19.1 )Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factornot less than 0.9, Service Value (CM/M/W) minimum 6.00, Air deliveryminimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019),THD less than 10%, remote or electronic regulator unit for speedcontrol and all remaining accessories including safety pin, nut bolts,washers, temperature rise=75 degree C (max.), insulation resistancemore than 2 mega ohm, suitable for 230 V, 50 Hz, single phase ACSupply, earthing etc. complete as required. |
33 | 122.2.155.(b):Supply, Installation, testing and commissioning of cubical type control panel board for single phase & Three Phasesubmersible pumping set of following rating complete with contactor, relay , MCB ,condenser ,voltmeter, ammeter and indication lamp etc includingconnections etc as reqd. 1.5 HP (Single Phase) |
34 | OD7925/2023-2024:SR 22 (1.24.5 )Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 amp socket outlet |
35 | OD7926/2023-2024:SR 22 (1.24.3) Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 amp switch |
36 | 122.2.86:SITC of 12 volt 150 AH initially charged SMF batteries i/c dismantling the old one (i/c credit for old deeply discharged batteries) and making connection , testing etc as required. |
37 | 122.2.150.(b):Supply, lowering and fixing following size of G.I. Pipe (M-Class) i/c cutting threading on both sides etc. ISI marked etcas reqd. 32mm(Nominal Bore) |
38 | 122.2.188:S/I/T/C of LED Tube type luminaire 2X20 watt rating box type complete with extruded Al. batten prewired with high efficient LEDs with the following: (A) Total system wattage 40 watt+/- 5% (B) Luminous efficacy lumens/ watt >=95(C) Power Factor >=0.95. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail