Tender For Provision Of 0.03 Mw Solar Power Plant For Lao Office Special Repair Replacement Of Lt Oh Line To Lt Ug Cable In Csd Residential Complex And Certain Minor Work Under Aor Of Ge Utility Ambala Cantt, ambala-Haryana

Military Engineer Services-MES has published Tender For Provision Of 0.03 Mw Solar Power Plant For Lao Office Special Repair Replacement Of Lt Oh Line To Lt Ug Cable In Csd Residential Complex And Certain Minor Work Under Aor Of Ge Utility Ambala Cantt. Submission Date for this Tender is 09-10-2023. Solar Power Plants Tenders in ambala Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

39525910
Corrigendum : Tender For Provision Of 0.03 Mw Solar Power Plant For Lao Office Special Repair Replacement Of Lt Oh Line To Lt Ug Cable In Csd Residential Complex And Certain Minor Work Under Aor Of Ge Utility Ambala Cantt
Open Tender
Indian
Haryana
ambala
09-10-2023

Tender Details

Provision Of 0.03 Mw Solar Power Plant For Lao Office Special Repair Replacement Of Lt Oh Line To Lt Ug Cable In Csd Residential Complex And Certain Minor Work Under Aor Of Ge Utility Ambala Cantt

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 19-Sep-2023 AMENDMENT BOQ 29-09-2023
2 29-Sep-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 06-10-2023
3 07-Oct-2023 AMENDMENT Date 09-10-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 99500.0 /-
Tender Value
INR 49.75 Lakhs /-

BOQ Items

Name of Work:PROVISION OF 0.03 MW SOLAR POWER PLANT FOR LAO OFFICE, SPECIAL REPAIR / REPLACEMENT OF LT OH LINE TO LT U/G CABLE IN CSD RESIDENTIAL COMPLEX AND CERTAIN MINOR WORK UNDER AOR OF GE (U) AMBALA CANTT.
Sl. No. Item Description
1Supply, fixing, Design, Installation, Testing & Commissioning of Grid connected roof top Solar Power Plant of 30KWP including Solar Panels, Solar Inverter, Module Mounting Structure and comprising of following:- (i) Solar PV module Pmax 550Wp C-Si 72 cells Efficiency not less than 16.20, Voc 45.00, Isc 9.03, AR coated antimony free glass material with connecting Junction box complete all as specified and directed.Make :- MNRE / SECI Approved (Country of origin- Made in India)
2Supply, fixing, Design, Installation, Testing & Commissioning of Grid Tied Inverter - 3 Phase / 415 Volts / 50 Hz having separate MPPTs with SPD having efficiency greater than or equal to 98% with Display Option, inbuilt LED interface with RS485 and compatible for online monitoring system suitable for ambient temprature of Ambala (Haryana), protection IP-65, Over-Voltage / Under-Voltage Protection complete all as specified and directed.Make - ABB / Siemens / Schneider / TATA / Solis - 35.0 kW
3Supply, fixing, Design, Installation, Testing & Commissioning of Protection Devices - (i) DC Solar distribution Box to collect the DC output from Array junction Box and supply to Inverter weather proof for outdoor applications and including DC MCB / DC Fuse - 30 A rated of proper rating depending upon the capacity of the power plant complete all as specified and directedMake :- Schneider / Siemens / ABB / L&T / Phoenix Contact (ii) AC Solar distribution Box to collect 3 phase AC output from invertor and connect with grid meter for outdoor applications and including MCB / MCCB of proper rating forcapacity of plant 30 KW Complete all as specified and directed.Make :- Schneider / Siemens / ABB / L&T /Phoenix contact with AC SPD
4Supply, fixing and assembling of Module Mounting Structure with Hot Dip Galvanised MS / Galvalume Mounting structure for mounting of Minimun 2.0 MM Thickness, Legs & Rafters should be erected with C-Lip of modules / array / panels etc such structure should have angle of inclination as per the site conditions to take max insolation, mounting structure shall be designed to withstand the speed of 150 KM per hour, having fastening arrangements, grouting, clamping etc, be provided to secure the installation against specific wind speed complete all as specified. Note:- The mounting structure steel shall be as per latest IS, and galvanisation of the mounting structure shall be in compliance. structural material shall be corrosion resistant and electrolytically compatiable with the materials used in the module frame, its nuts and bolts. The fasteners used should be made up of mild steel. The structures shall be designed to allow easy replacement of any module .
5Supply and fixing of 3 phase DLMS type integrated meter with inbuilt CT& GSM Modem energy meter having LCD display, 50 Hz ± 5%, Provision of sealing on mains cover and terminal cover, IP 51, tamper proof, inbuilt battery back up to activate its display in absence of power, Optical port for local communication, Optional RS232 port on RJ-11 for remote communication, in built memory for load survey data. Class 0.5s, (3X 240V (P-N), -/5A) Complete all as specified and directed by Engr-In-Charge. Make : Secure / HPL / Siemens / L&T/Scheneider
6Supply and fixing of Bi-directional 3 phase DLMS type integrated meter with inbuilt CT meter having LCD display, 50 Hz ± 5%, Provision of sealing on mains cover and terminal cover, IP 51,tamper proof, inbuilt battery back up to activate its display in absence of power, Optical port for local communication, Optional RS232 port on RJ-11 for remote communication, in built memory for load survey data. Class 0.5s, (3X 240V (P-N), -/5A) Complete all as specified and directed by Engr-In-Charge. Make : Secure /HPL/Scheneider
7Supply and Supply ofmaintenance free chemical earthing using pure copper electrode dia 50 mm 3 mtr long and80mm boreand connected with 25X4mm Copper stripupto test point(Gun metal) and connected from test point to appliances by 16 sqmm aluminium wire with PVC insulation complete with excavation earth work cast iron cover with back fill compound (Chemical for earth enhance gel--40Kg) . Complete all as specified and directed. Note: (i) Resistance Value should be less than 1 ohm. It shall be tested before considering for payment. (ii)25X4mm Copper strip connecting upto test point and 16 sqmm aluminium wire with PVC insulation connecting from test point to appliances.
8Supply andfixing double corrugated(DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to ISI 14930(part-I and II) for protection of UG cables size 50 sqmm outer dia with all fittings.laid in trenches/road/drain or fixed along wall,poles or laid under floor (incl. cutting floor/road and making good to match with existing adjioining surfaces etc for cable protection complete all as specified and directed by Engr-In-Charge. Make-REX/POLY/Gemine. Note :- (excavation and earth work shall be measured and paid separately under respective item of BOQ.)
9Supply and fixing of DC Connection wire SPV to Invertor. by using 4sqmm Dual PVC TUV approved with MC4 Connectors Terminals IP66 PVC, tined Copper used.Complete all as specified and directed by Engr-In-Charge.
10Supply and fixing of TUV Certified MC4connectors by using crimping kit with pins including all accessories Complete all as specified and directed by Engr-In-Charge.Make -Sibbas/Waree/SAPA and Wire Make -Waacab/KEI/Havells/Polycab
11Supply and fixing ofESE Surge Lightning Protection Device for SPV protection Tuv certified with test Report min Area Covered 60mtr Radius around SPV with SS Steel Ground Mount by using Stay wire , stand Hot dip Galvanised height-10Ft. max. Complete all as specified and directed by Engr-In-Charge. Make-SAPA/RB/Truepower/GSI
12Supply and fixing ofSLD Layout,String marking layout, safety Do"s & Don"ts, Danger plate mount with GI Metal, with complete supporting components, Design & Using SS fastners Complete all as specified and directed.
13M&L for PCC 1:2:4 type B0 (12.50mm aggraded aggregate ) as in coping or foundationwork for securing solar panels legswith using WP solvent mixture make Dr. Fixit/Tectyl TM 506/Floorex/ MR Bond Polychem, foundation size 30x30x40 cm with proper making good the distrubed surface using exterior emulsion paint. Make: Nerolac/Asian paints/Nippron panits etc Complete all as specified and directed by Engr-in-charge.
14Supply and installing, testing & commissioning of factory fabricated outdoor type feeder pillar board of size 1000X850X500 mm , outer shell made out of3.15 mm thick CRCA sheet and inner shell made out of 2 mm thick CRCA sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 80 cm aboveand 45 cm below the ground level,frame factory fabricated with front openable double door system and cable alley(Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open ablewith arrangement of pad locking on door01 no of pad lock of three keys shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at factory approved from CPRI factory fabricatedhaving modern fabrication and testing process followed by powder coated painting after 7-tank pre treatement control & power wiring with suitable size of copper conductor along with suitable gasket to make it dust/vermin proof and general construction confirming to IS:61439/2011Part-1 andpart -2 type test certificate with not less thanIP-65and breaking capacity 56 KA comprising of the following :- (a)MCCB 200 Amps TPN, 25 KA -01 No (Make:- Havells/L&T/Legrand/Indoasian/ABB) (b) MCCB63 Amp, 10 KA TPN 415 volts AC, (Outgoing) - 05 Nos (Make:- Havells/L&T/Legrand/Indoasian/ABB) (c) Cu busbar of capacity 300 Amps with colour coated heat shrinkable sleeve and suitable hole for out going connection - Set of four. (d) Digital Ammeter flush pattern type square dial 96 x 96 mm alongwith selector switch - 01 No and suitable CT ratio 0-300 Amps (e) Digital Voltmeter flush pattern type square dial 96 x 96 mm alongwith selector switch - 01 No 0-500V. (f) Indicator lamp for R,Y & B for each incoming and outgoing feeder including misc items like screws, cable tie, copper cable 1.5/2.5 Sqmm, cable lugs, sleeves, glandsetc Complete are included in quoted rates
15Material and labour for earthing complete with galvanized steel plate earth electrode 60cmx60cmx6mm thick surrounded by char coal and salt buried directly in ground vertically in pit of depth not less then 2.25 mtr below ground level with top edge of the earth plate at depth of not less than 1.5 mtr below ground level surrounded from all sides by char coal dust and common salt in alternate layers of 15 cm depth and earth plate electrode connected to galvanised earth lead wire of 4.0 mm dia by means of GI nuts bolts, check nuts and washers and connected to earthing test point drawn through 15 mm bore GI pipe medium grade for protection of GI earth lead wire including 20mm bore GI pipe medium grade for watering GI funnel PCC earth pit (1:3:6) type C-2 with CI frame and RCC cover all as shown in electrical Plate No 3 on SSR Part - I including testing complete all as specified and as directed. Note : (i) The quoted rate shall include the cost of earth work, GI pipe for watering, GI protection pipe, funnel, wire mesh, RCC cover, etc. complete. RCC cover shall be 50mm thick in 1:2:4 type B-1 using 8mm bars @10cm c/c both way. (ii) The quoted rate shall include the cost of the earth pit covers to be conspicuously marked of plate with standgrouted in PCC. (iii) On testing after completion if the desired earth resistance ismore than 2? the earthing will be redone at no extra cost
16Supply and laying, connecting and testing ofXPLE underground cable insulated, and overall sheathed with aluminium conductor heavy duty 1100 volts grade 95 sqmm 3.5 core laid in trenches/ on pole/road crossing or passing through existing/new pipe under road crossing clamping on wall etc. Note : (i) Earth work, sand , bricks shall be measured and paid seperately. (ii) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways are incl in the quoted rates. (iii)All equiments, machinery or tool if required for laying electrical cable through new pipes are provided by the contractor without any extra cost.
17Supply and laying bricks, common burnt clay, sub class "B", old size, laid in vertical direction to cable as cable protection.Complete all as specified and as directe by Engr-In-Charge.
18Material and labour for cable route indicator showing "MES LT UG 1.1KV" and route of cable with arrow (should be embossed or engraved) made of RCC in suitable shape and fixed in PCC block 1:3:6 type C-2 using 40mm graded aggregate including brick work and excavation, size of route indicator 70cm x 30cm x 10cm, 30cm below ground level and 40cm above ground level to show clear indication of cable including painting the Complete slab with red paint and making the engraved/embossed letters/arrow with white paint. Complete all as specified and as directed by Engr-In-Charge.
19Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in loose / soft soil and getting out for under ground cable / erection of poles, stays etc complete all as specified and as directed by Engr-In-Charge.
20All as per item No 19 here in before but exceeding 1.5 mtr and not exc. 3.0 mtr.
21Returning, filling in, in soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick compacted each layer. Complete all as specified and directed.
22Removing of excavated material n, exc 50 mtr away and depositing where directed at a level n, exc 1.5 mtr above the starting point complete all as directed by Engr-In-Charge.
23Disconnecting & taking out defective underground cable any size and any type from trenches, pole, pipe, floor, wall etc.
24M&L for sand cushioning for cable with river washed sand with a layer of 8 cm before laying the cable and 15 cm deep after laying the cable. (Punned down to 18 cm after laying and streaching of cable). Complete all as specified and directed by Engr-IN-Charge. Note: Punned thickness of sand layer shall be 18 cm and same will be considered for payment to contractor.
25Material & labour for cement concrete in foundations, filling and mass concrete PCC as foundation to poles, type D2, 1:4:8 using 40 mm graded stone agregate as foundations to poles all as specified.
26Material & labour for Cement concrete, filling and mass concrete, PCC type C2, 1:3:6 using 20 mm graded agregateas coping to poles all as specified.
27Material & labour for cement concrete in foundations, filling and mass concrete PCC as foundation to poles, type B2, 1:2:4 using 40 mm graded stone agregate as foundations to poles all as specified.
28Material and labour for steel tubular poles complete with cast iron base plate, finial taper plug, bolts,nuts & screws as specified type 410 SP -55 (11.0 meters long) conforming to IS- 1678 and including marking alternate 05 Nos white and black strip 30cm height with two coats of synthetic enamel paint including preparation of surfaces, upto 1.5 mtr above the coping of pole , starting with black strip complete all as specified and directed. Note : Excavation and earth work and PCC for foundation channel, clamps, nuts, bolts to be measured and paid separately.
29M&L for Switch air break gang operated triple pole mechanically operated, vertical type 12 insulators and with galvanized steel frame, operated from ground level including operating rod, handle locking mechanism, current carrying capacity 200 amps, 11000 volts, fixed with nut, bolt and washers of required quantity, Complete all as specified and as directed
30Material and labour for lightning arrestor expulsion type 11000 Volt grade of capacity 65 KA including, connecting with HT line Complete all as specified & directed by Engr-In-Charge
31Supply, Laying and connecting XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor 11000 volts grade, cross sectional area 95 sq mm 3 core suitable for 11 KV earthed system, including taking down old cable of any size. Complete all as specified and directed by Engr-In-Charge. Note : (i) Earth work, sand , bricks shall be measured andpaid seperately. (ii) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways are incl in the quoted rates(iii)All equiments, machinery or tool if required for laying electrical cable through new pipes are provided by the contractor without any extra cost.
32Supply, Laying and connecting including testing XLPE cable underground PVC insulated and over all sheathed with aluminium conductor heavy duty 1100 volts cross sectional area 300 Sqmm 3 ½ core grade laid in trenches, floors, ducts passing through pipe forroad crossing etc Complete all as directed by Engr-in-Charge. Note : (i) Earth work, sand , bricks shall be measured andpaid seperately. (ii) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways are incl in the quoted rates(iii)All equiments, machinery or tool if required for laying electrical cable through new pipes are provided by the contractor without any extra cost.
33Supply, Laying and connecting including testing XLPE cable underground PVC insulated and over all sheathed with aluminium conductor heavy duty 1100 volts cross sectional area 50 Sqmm 3 ½ core grade laid in trenches, floors, ducts passing through pipe forroad crossing etc Complete all as directed by Engr-in-Charge. Note: (i) Earth work, sand , bricks shall be measured andpaid seperately. (ii) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways are incl in the quoted rates(iii)All equiments, machinery or tool if required for laying electrical cable through new pipes are provided by the contractor without any extra cost.
34Supply, Laying and connecting including testing XLPE cable underground PVC insulated and over all sheathed with aluminium conductor heavy duty 1100 volts cross sectional area 25 Sqmm 3 ½ core grade laid in trenches, floors, ducts passing through pipe forroad crossing etc Complete all as directed by Engr-in-Charge. Note: (i) Earth work, sand , bricks shall be measured andpaid seperately. (ii) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways are incl in the quoted rates(iii)All equiments, machinery or tool if required for laying electrical cable through new pipes are provided by the contractor without any extra cost.
35Supply, Laying and connecting including testing XLPE cable underground PVC insulated and over all sheathed with aluminium conductor heavy duty 1100 volts cross sectional area 10 Sqmm 4 core grade laid in trenches, floors, ducts passing through pipe forroad crossing etc Complete all as directed by Engr-in-Charge. Note: (i) Earth work, sand , bricks shall be measured andpaid seperately. (ii) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways are incl in the quoted rates(iii)All equiments, machinery or tool if required for laying electrical cable through new pipes are provided by the contractor without any extra cost.
36Supply, Laying and connecting including testing XLPE cable underground PVC insulated and over all sheathed with aluminium conductor heavy duty 1100 volts cross sectional area 10 Sqmm 2 core grade laid in trenches, floors, ducts passing through pipe forroad crossing etc Complete all as directed by Engr-in-Charge. Note: (i) Earth work, sand , bricks shall be measured andpaid seperately. (ii) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways are incl in the quoted rates(iii)All equiments, machinery or tool if required for laying electrical cable through new pipes are provided by the contractor without any extra cost.
37Supply and fixing in replacement of rigid non-metallic PVC conduit of dia 20 mm exclusive of boxes (Junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. Note: PVC pipe will be clamped at three position on pole and cost of clamp, nut, bolts etc are incl in quoted rates Complete all as specified and directed by Engr-In-Charge.
38Supply & fixing GI tubing light grade 80mm bore, on poles, under floors, road crossing etc all as reqd at site and as directed.
39Supply & fixing GI tubing light grade 50mm bore, on poles, under floors, road crossing etc all as reqd at site and as directed.
40Material & labour for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections of any size and shape including nut, bolts, washers, welding, bending, cold or hot drilling holes in bolts of any sizeincluding two coats of aluminium paint over one coat of primer including taking down old. Complete all as specified and as directed by Engr-In-Charge.
41Dismantling andtaking down old u/s earthing andMaterial and labour for earthing complete with galvanized steel plate earth electrode 60cmx60cmx6mm thick surrounded by char coal and salt buried directly in ground vertically in pit of depth not less then 2.25 mtr below ground level with top edge of the earth plate at depth of not less than 1.5 mtr below ground level surrounded from all sides by char coal dust and common salt in alternate layers of 15 cm depth and earth plate electrode connected to galvanised earth lead wire of 4.0 mm dia by means of GI nuts bolts, check nuts and washers and connected to earthing test point drawn through 15 mm bore GI pipe medium grade for protection of GI earth lead wire including 20mm bore GI pipe medium grade for watering GI funnel PCC earth pit (1:3:6) type C-2 with CI frame and RCC cover all as shown in electrical Plate No 3 on SSR Part - I including testing complete all as specified and as directed. Note : (i) The quoted rate shall include the cost of earth work, GI pipe for watering, GI protection pipe, funnel, wire mesh, RCC cover, etc. complete. RCC cover shall be 50mm thick in 1:2:4 type B-1 using 8mm bars @10cm c/c both way. (ii) The quoted rate shall include the cost of the earth pit covers to be conspicuously marked of plate with standgrouted in PCC. (iii) On testing after completion if the desired earth resistance ismore than 2? the earthing will be redone at no extra cost
42Dismantling andtaking down old M& L for new earthing complete with galvanized steel plate earth electrod 60cmx60cmx6mm thick surrounded by charcoal and salt buried directly in ground vertically in pit of depth not less than 2.25 mtr below ground level with top edge of the earth plate at depth of not less than 1.5 mtr below ground level, earth plate electrode connected to GI wire 4 mm dia by means of GI nuts, bolts, washers and check nuts including 20mm dia for watering and 15mm dia GI protection pipe light grade, GI funnel, PCC earth pit (1:3:6) type C2 with CI frame and RCC cover all as shown in electrical plate No 3 ofSSR Part-I. Note : (i) The quoted rate shall include the cost of earth work, GI pipe for watering, GI protection pipe, funnel, wire mesh, RCC cover, etc. complete. RCC cover shall be 50mm thick in 1:2:4 type B-1 using 8mm bars @10cm c/c both way. (ii) The quoted rate shall include the cost of the earth pit covers to be conspicuously marked of plate with standgrouted in PCC. (iii) On testing after completion if the desired earth resistance ismore than 2? the earthing will be redone at no extra cost
43Dismantling andtaking down old unsv LT panel and Supplying, installing, testing & commissioning out door type cubical panel board of size 1.2Mx0.9Mx0.5M outer shell made out of3.15 mm thick MS sheet including door frame, Persplex Sheet for front door only 6 mm thick should be properly fixed with minimum 80% coverage in door and inner shell made out of 2 mm thick MS sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm aboveand 45 cm below the ground level,frame factory fabricated with front & back openable, double door system and cable alloy (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able by Keyshaving chromium plated 19 mm dia fancy lock, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at factory approved from CPRI factory fabricatedhaving modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93 comprising of the following :- a) TPN Aluminium bus bar 600 Amps insulated with colour coded heat shrinkable sleeve heavy duty and shall be mounted on suitable size “F” class insulators not less than 1.0 mtr long b) Incoming MCCB 400 Amps 4 pole 415 Volts 50 KA AC,Icu=100%Ics, having thermal and magnetic adjustable with spreader links complete conforming to IS/IEC 60947-2. -01 Nos c) Incoming MCCB 160 Amps 4 pole 415 Volts 25 KA AC,Icu=100%Ics, having thermal and magnetic adjustable with spreader links complete conforming to IS/IEC 60947-2. -02 Nos d) Outgoing MCCB 63Amps 4 pole 415 Volts 16 KA AC,Icu=100%Ics, having thermal and magnetic adjustable with spreader links complete conforming to IS/IEC 60947-2. - 01 Nos. (f) Digital Ammeter 0-500 A of size 96sqmm with selector switch-01 No. (g) Digital Volt meter 0-500 V of size 96sqmm with selector switch-01 No (h) Indicator Lamp RYB 22.5mm dia LED type 240 volts AC with incoming includin back up protection by 2 Amp MCB RYB with holder-01 set of three. (j) CT Coils of suitable ratio-01 Set. Make-AE
44Dismantling andtaking down old unsv LT panel and Supplying, installing, testing & commissioning out door type cubical panel board of size 1.2x0.9x0.5M outer shell made out of3.15 mm thick MS sheet iincluding door frame, Persplex Sheet for front door only 6 mm thick should be properly fixed with minimum 80% coverage in door and inner shell made out of 2 mm thick MS sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm aboveand 45 cm below the ground level,frame factory fabricated with front & back openable, double door system and cable alloy (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able by Keyshaving chromium plated 19 mm dia fancy lock, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at factory approved from CPRI factory fabricatedhaving modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93 comprising of the following :- a) TPN Aluminium bus bar 250Amps insulated with colour coded heat shrinkable sleeve heavy duty and shall be mounted on suitable size “F” class insulators not less than 1.0 mtr long b) Incoming MCCB 160 Amps 4 pole 415 Volts 25 KA AC,Icu=100%Ics, having thermal and magnetic adjustable with spreader links complete conforming to IS/IEC 60947-2. -01 Nos c) Outgoing MCCB 63Amps 4 pole 415 Volts 16KA AC,Icu=100%Ics, having thermal and magnetic adjustable with spreader links complete conforming to IS/IEC 60947-2 -03 Nos (d) Digital Ammeter 0-500 A of size 96sqmm with selector switch-01 No. (e) Digital Volt meter 0-500 V of size 96sqmm with selector switch-01 No (f) Indicator Lamp RYB 22.5mm dia LED type 240 volts AC with incoming includin back up protection by 2 Amp MCB RYB with holder-01 set of three. (g) CT Coils of suitable ratio-01 Set. Make-AE h) MCB 32 Amp, TP, 415 Volts
45Dismantling andtaking down old unsv LT panel and Supplying, installing, testing & commissioning out door type cubical panel board of size 1.2x0.9x0.5M outer shell made out of3.15 mm thick MS sheet including door frame, Persplex Sheet for front door only 6 mm thick should be properly fixed with minimum 80% coverage in door and inner shell made out of 2 mm thick MS sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm aboveand 45 cm below the ground level,frame factory fabricated with front & back openable, double door system and cable alloy (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able by Keyshaving chromium plated 19 mm dia fancy lock, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at factory approved from CPRI factory fabricatedhaving modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93 comprising of the following :- a) TPN Aluminium bus bar 250Amps insulated with colour coded heat shrinkable sleeve heavy duty and shall be mounted on suitable size “F” class insulators not less than 0.8 mtr long b) Incoming MCCB 160 Amps 4 pole 415 Volts 25 KA AC,Icu=100%Ics, having thermal and magnetic adjustable with spreader links complete conforming to IS/IEC 60947-2. -01 Nos c) Outgoing MCCB 63 Amps 4 pole 415 Volts 16 KA AC,Icu=100%Ics, having thermal and magnetic adjustable with spreader links complete conforming to IS/IEC 60947-2. -03 Nos (d) Out going MCB TPN 32 Amps-03 Nos. (e) Digital Ammeter 0-500 A of size 96sqmm with selector switch-01 No. (f) Digital Volt meter 0-500 V of size 96sqmm with selector switch-01 No (g) Indicator Lamp RYB 22.5mm dia LED type 240 volts AC with incoming includin back up protection by 2 Amp MCB with holder-01 set of three. (h) CT Coils of suitable ratio-01 Set. Make-AE
46Dismantling andtaking down old unsv LT panel and Supplying, installing, testing & commissioning out door type cubical panel board of size 0.6x0.6x0.5M outer shell made out of3.15 mm thick MS sheet including door and inner shell made out of 2 mm thick MS sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm aboveand 45 cm below the ground level,frame factory fabricated with front & back openable, double door system and cable alloy (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able by Keyshaving chromium plated 19 mm dia fancy lock, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at factory approved from CPRI factory fabricatedhaving modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93 comprising of the following :- a) TPN Aluminium bus bar 160Amps insulated with colour coded heat shrinkable sleeve heavy duty and shall be mounted on suitable size “F” class insulators not less than 0.8 mtr long b) Incoming MCCB 100 Amps 4 pole 415 Volts 25 KA AC,Icu=100%Ics, having thermal and magnetic adjustable with spreader links complete conforming to IS/IEC 60947-2.-01 Nos b) Outgoing MCCB 63 Amps 4 pole 415 Volts 16 KA AC,Icu=100%Ics, having thermal and magnetic adjustable with spreader links complete conforming to IS/IEC 60947-2.-01 Nos (c) Out going MCB SPN 20 Amps-01 Nos. (e) Digital Ammeter 0-500 A of size 96sqmm with selector switch-01 No. (f) Digital Volt meter 0-500 V of size 96sqmm with selector switch-01 No (g) Indicator Lamp RYB 22.5mm dia LED type 240 volts AC with incoming includin back up protection by 2 Amp MCB RYB with holder-01 set of three. (h) CT Coils of suitable ratio-01 Set. Make-AE
47Note :- Sr Item No 43 to 46 (i) The quoted rate shall include minor items such as lugs, nuts & bolts, washers, top insulators, sleeves,link spreader provision of extra holes in bus bar etc. (ii)All internal wiring shall be done with suitable size of PVC insulated solid copper conductor FRLS cable conforming toIS-694. (iii) Panel drawing shall be got approved from Engr-in-Charge/GE before placing of order. (iv) The bus connection for cable from main bus bar to outgoing MCCB will be connected through suitable rating bus bar strip type duly insulated. (vi) The Panel shall be surrounded with 9 inch brick wall upto 0.5 mtr height all around the panel and blank portion between panel and wall shall be filled with PCC 1:2:4incl masonary work leaving ducts for cables complete all as directed.
48Supply and fixing of cable end jointing kit as in repair for 11 KV(Earthed) grade cable for outdoor end termination, cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 sqmm.Complete all as specified and directed by Engr-In-Charge.
49Supply and fixing of cable end jointing kitas in repair for 11 KV(Earthed) grade cable for straight through, cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmmto 95 sqmm complete all as specified and directed by Engr-In-Charge.
50Material and labour for danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size for HT, 25x20 cm size. Complete all as specified and directed.
51M&L for drilling hole of any size manually as per site requirement, drilling for laying pipes under the road for crossing electrical cable. Complete all as per direction of Engr-in-Charge
52Material and labour for cable route indicator showing "MES HT UG 11KV" and route of cable with arrow (should be embossed or engraved) made of RCC in suitable shape and fixed in PCC block 1:3:6 type C-2 using 40mm graded aggregate including bricks works and excavation, size of route indicator 60cm x 30cmx 10cm, 30cm below ground level and 30cm above ground level to show clear indication of cable including painting the complete slab with red paint and making the engraved/embossed letters/arrow with white paint. Complete all as specified and as directed by Engr-In-Charge.
53Cable jointing kit suitable as in repair for 1.1KV grade cable out door end termination, heat shrinkable type joint complete with jointing material and accessories suitable for 300 Sqmm3.5 coreXLPE armoured aluminium conductor cable. Complete all as directed by Engr-In-Charge.
54Cable jointing kit suitable for 1.1KV grade cable out door end termination, heat shrinkable type joint complete with jointing material and accessories suitable for 50 to 95 Sqmm3.5 coreXLPE armoured aluminium conductor cable. Complete all as directed by Engr-In-Charge.
55Supply and fixing in replacement of fabrication of Kiosk box made out of fibre material complete with TPN ,aluminium bus and suitable for one number MCB (SP) including one No MCB (SP) 6 Amps 240 volts with glands for incoming & out going cable including fixing of flat iron clamps of size 20x4mm on PCC/Steel tubular pole.Complete all as specified and as directed by Engr-in-Charge.
56Supply,errection of steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type SP-31 (9 mtrs long) inclproviding black and white strips with synthetic enamel point 30 cm each alternate upto 1.5 mtr above the coping of pole starting with black strip complete all as specified and as directed by Engr-in-charge. Note: Earth work and PCC shall be measured and paid separately. (ii) Description as per direction of Engr-in-Charge will be printed on each pole without any extra cost.
57Material & Labour as in repair for PVC insulated three core unsheathed multi stranded cable copper conductor wire 1100 volts grade of size 1.5 sq mmfor lights and connecting with Busbar/Connector. Complete all as directed by Engineer -in-charge.
58Supply & fixingin replacement ofLED street light fitting70 watts made up of pressure die cast aluminium housing with high efficiency LEDs as lighting source and lens embedded PC cover/ toughened glass having TOP Opening seperate driver compartment with IP 66 protection and impact resistance of IK07 consisting of suitable number of LEDs with sealed toughened glass cover, 5700K,LED efficiency >110 lm/Watt and system efficiency 110 lm/W , 240 Volts AC, 50 Hz, CRI>70% operating voltage range 140 V-270 V, Power factor> 0.95,mains current 0.270A, working temperature range-10ºC to 50ºC,built in surge protection of more than 10 kV, better optics for uniform distrubution with multiple LEDs not less than 2 watt each and having optical grade polycarbonate lens with all accessories , suitable for side entry, pole mounting with bracket arm OD 40 mm, recommended mounting height with suitable inground reinforcement is 8 mtrs, Confirm the safety test as per IS 15885 part-2 from auth labs :LM79 & LM 80, incl proper fixing and testing of street lights on 9/11 mtr long steel tubular poleincl make proper connection of new and existing light fittings complete with cutting , welding , drilling holes, nut bolts, washer complete all as directed by Engineer-in-charge. Note :-PVC heavy duty conduit pipe along with 3/1 run of 1.5/2.5 sqmm PVC insulated unsheathed/sheathed copper multistranded conductor from MCB box to streetshall be measured and paidfor separately.
59Repairing of existing unserviceable PCC coping of LT/HT pole by breaking completely and material and labour for PCC 1:2:4 type B1, (using 20mm graded crushed stone aggregate) of size 600X600X300mm including form work and applying two coats of white wash. Complete all asspecified and directed by Engr-In-Charge.
60Material and labour for vibratory compactive,precast cement concrete rubber moulded, coloured (except grey colour), interlocking designer paver blocksin Milano shape, comfirming to IS-15658-2006 of 60 mm thickness, M-35 grade, as in path, hardingstanding, etc laid over and including 25 mm compacted sand cushioning, including 75 mm thick PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate including surface excavationover area n. exc. 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil and removing excavated soil exc. 50 mtr but n. exc. 250 mtr. Complete all as specified and directed by Engineer-in-charge.
61S&F in replacement of MS clamp suitable for holding street light bracket on steel/PCC polemade out of 40 mm x6 mm thick flat iron with M.S nuts bolts 50 mm long 10 mm dia-3 Nos with flat washer 3mm thick -02 No for each includingpainting with aluminium paint over one coat of red oxide primer to the M.S clamps all as specified and as directed by Engr-In-Charge
62S&F in replacement of bracket made out of GI tubing single piece not welded, bended at proper angle of size 40mm dia, light grade 1.5 mtr long including painting with aluminium paint over one coat of red oxide primer to the bracket for street light fitting all as specified and as directed by Engr-In-Charge.
63Supply & fixing in replacementof Automatic Street Light Control Switch with Infrared Sensor based NATURE SWITCH & Voltage Monitoring System (VMS). Three phase, 20 Amps per phase, MCB rating 40 Amp, max load 5-8 kw incl circuit copper wire 10 sq.mm.Nature Switch operation should be based on Natural Light Lux level. Required Illuminance Level for Switching ON is = 60 Lux and for switching OFF = 10 Lux. The Sensor should also have part night operation facility of min. 4 to max. 12 hrs. VMS should have Adjustable Over & Under Voltage Trip level and Protection against Phase Loss, Neutral Loss & Phase Reverse. The Sensor & VMS along with suitable Power Contactor(s) and Incoming-Outgoing MCBs should be enclosed in a pole/wall mountable Enclosure made of Rust Proof, Electric Shock Proof, Termite proof and FR grade SMC Junction box conforming to IP54. The circuit should also have provision for Manual Operation (i.e. By-Pass Option for both Sensor (NS-02) and VMS). Model : Swadeep-02EC-5kW3P-VMS complete all as specified and directed. Note(i) Nut bolts, clamp for fixing on poles/wall are to be included in quoted rates. (ii)The sensor must have the warranty of min of 2 years. (iii)The test certificate and warranty certificate must be provided by supplier.(iv) Cost of marking description on the box is incl quoted rate.
64Supply only chain link fencing including line wires of 4 mm dia with 50x50 mm mesh size and type of strandard rails , straining bolts etc including provision of bending wire. Note : (i) weight of Barbed wire shall be measured by Engineer-in-Charge at site before in corporation in work and give due endorsement in MB.
65Fixing only chain link fencing including line wires of 4 mm dia with 50x50 mm mesh size and type of strandard rails , straining bolts etc including provision of bending wire including taking down old. Complete all as specified and directed by Engr-in-Charge.
66S&F as in repair Mild; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 290 Gde E-165. Complete all as specified and directed by Engr-In-Charge.
67Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, but lenth of bolt exc 5cm and n exc 10 cm long and diameter of neck 10mm Complete all as specified and directed by Engr-In-Charge.
68S & F as in repair Mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
69M&L two coats of synthetic enamel paints on newsteel Surfaces exc 10cm girth over a coat of red oxide primer when unconnected with other painting or when painted in a different tint complete all as specified and directedby Engr-IN-Charge.
70M&L two coats of synthetic enamel paints on steel Surfaces exc 10cm girth over a coat of red oxideComplete all as specified and directed by Engr-In-Charge.
71M&L for PCC 1:4:8 type D-2 using 40mm graded stone aggregate, mechanically crushed stone for mass filling in polepit and foundation etc. Complete all as specified and directed.
72M&L for cement concrete (1:3:6) type C-2using 40mm graded stone aggregate as coping of pole and strut, stayaround the poleetc. Completeall as specified and directed by Engr-In-Charge.
73Material and labour for brick work with sub class "B" (old size) bricks, straight or curved on plan, exceeding 6 mtr mean radius built in CM 1:6complete all as specified and directed.
74Material & Labour for PCC 1:2:4 type B-0 (using 12.5 mm graded mechanical crushed aggregate) for benching, coping, covering etc. complete all as specified & directed by Engineer-in-Charge.
75M&L hardcore bocken stone boulder Hand packing (any thickness) at back of walls over arches etc. and raising (or lowering) to the required levelComplete all as specified as directed by Engr-In-Charge.
76M&L 100 mm thick PCC 1:2:4 type B1(20mm aggraded aggregate ) finishing cement concrete surface even and smooth without using extra cement Complete all as specified as directed by Engr-In-Charge.
77M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finishing the surface fair and even smooth without using extra cement all as specified as directed by Engr-In-Charge.
78M&L for preparation and applying three coats of white wash on new plastered surface of wall.
79M & L Moorum/red bajri filling in floors or pavings, laid in layers n exc.15 cm thick, spread, levelled and rammed including watering.
80Material and labour for hardcore broken stone or boulders filling of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed by Engr-In-Charge.
81S&F in replacement MCB TPN 4 pole 63 Amp, B type, 415 Volts, 50 Hz. Complete all as specified and directed by Engr-In-Charge.
82Dismantling and taking down old unserviceable ACSR conductor incl cutting, complete all as per direction of Engr-In-Charge.
83Supply & fixingin replacement of Integral LED Flood light Luminaries 100 Watts consisting of suitable number of LEDs andmounted on MCPCB high pressure die cast aluminium housing with sealed toughened glass cover with secondary optics lens,IP 66 protection suitable for mast light mounting, 5700K,LED efficiency >130 lm/Watt and system efficiency 110 lm/W , 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, Power factor> 0.95, working temperature range -10ºC to 50ºC,built in surge protection of more than 10 kV ,Confirm the tests from auth labs :LM79 & LM 80, incl proper fixing and testing of flood lights on 9/11 mtr long steel tubular pole and provide facility of power supply shall be provide as suitable for maint work of light fittings incl make proper connection of new and existing light fittings complete with cutting, welding, drilling holes, nut bolts, washer complete all as directed by Engr-In-Charge.
84Supply & fixingin replacement ofLED street light fitting20 watts made up of pressure die cast aluminium housing with high efficiency LEDs as lighting source and lens embedded PC cover/ toughened glass having TOP Opening seperate driver compartment with IP 66 protection and impact resistance of IK07 consisting of suitable number of LEDs with sealed toughened glass cover, 6500K,LED efficiency >110 lm/Watt and system efficiency 110 lm/W , 240 Volts AC, 50 Hz, CRI>70% operating voltage range 140 V-270 V, Power factor> 0.95,mains current 0.270A, working temperature range-10ºC to 50ºC,built in surge protection of more than 10 kV, better optics for uniform distrubution with multiple LEDs not less than 2 watt each and having optical grade polycarbonate lens with all accessories , suitable for side entry, pole mounting with bracket arm OD 40 mm, recommended mounting height with suitable inground reinforcement is 8 mtrs, Confirm the safety test as per IS 15885 part-2 from auth labs :LM79 & LM 80, incl proper fixing and testing of street lights on 9/11 mtr long steel tubular poleincl make proper connection of new and existing light fittings complete with cutting , welding , drilling holes, nut bolts, washer complete all as directed by Engr-IN-Charge. Note :-PVC heavy duty conduit pipe along with 3/1 run of 1.5/2.5 sqmm PVC insulated unsheathed/sheathed copper multistranded conductor from MCB box to streetshall be measured and paidfor separately.
85Surface excavation in soft/loose soil not exceeding 30cm deep and averaging 15 cm deep and getting out. Complete all as specified and as directed by the Engineer–in–Charge
86M&L for cement concrete 50mm thick (1:3:6) type C-1using 20mm graded crushed stone aggregate as in plinth protection finished fair and even .Completeall as specified and directed by Engr-In-Charge.
87M&L for damp proof course to horizontal or vertical surfaces including necessary formwork, 40mm thick, in cement concrete 1:2:4 type B0 complete all as specified and as directed by the Engineer–in–Charge
88M&L for applying evenly a coat of blown type bitumen at the rate of 1.50 kg per sqm and blinding with clean dry sand @ 0.05 cum per sqm complete all as specified and as directed by the Engineer–in–Charge
89M&L for polythene film, 150 micron thick, laid on a coat of bitumen primer @ 0.30 to 0.50 kg per sqm complete all as specified and as directed by the Engineer-in-Charge
90M&L for rendering 15mm thick on other than fair faces of brick wall or concrete surfaces in cement mortar 1:4 finished fair and even without using extra cement complete all as specified and directed.
91M&L for rendering 15mm thick on fair faces on brick wall or concrete surfaces in cement mortar 1:6 finished fair and even without using extra cement all as specified.
92Supply only Integral water proofing compound complete.
93M&L for preparation of newly plaster surfaces on wall and applying three coats of white wash complete all as specified and directed.
94M&L for preparation of newly plaster surfaces on wall and applying two coats cement based paint over a coat of alkali resistant primer complete all as specified.
95M&L for 75 mm thick PCC Type D–2, 1:4:8 (using 40mm graded crushed stone aggregate) as in sub base of floor complete all as specified and as directed.
96M&L for 40 mm thick PCC Type B–1, 1:2:4 (using 20mm graded crushed stone aggregate) as in sub base of floor before tiling. complete all as specified and as directed.
97M&L for non–skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.11sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
98M&L for glazed ceramic tile in vertical surface such as skirting and dados size 450x300x7–8 mm thick on screed bed or bedding layer of mortar 10mm thick in CM 1:3 set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade complete all as specified and directed.
99S&F for Pre–painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed
100S&F mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161–1979 grade St.–240 complete all as specified and directed
101S&F of 15mm size PVC connections with PTMP nuts of length 450mm complete all as specified and as directed by the Engineer–in–Charge
102S&F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed by the Engineer–in–Charge
103S&F 110mm bore PVC (SWR) bends of any radius, complete all as specified
104S&F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and as directed by the Engineer–in–Charge
105S&F 75mm bore PVC (SWR) bends of any radius, complete all as specified
106S&F 75mm bore PVC (SWR) vent cowl, complete all as specified
107M&L for 15mm bore "medium grade" GI tubing with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by the Engineer–in–Charge
108M&L for 20mm bore "medium grade" GI tubing with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by the Engineer–in–Charge
109S&F 500 litres rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position, connecting up pipes, securing access covers etc., and 20mm ball valve with float and flynut screwed to pipe including dismantling of water tanks and removing to store all as specified in SSR Part–I complete all as specified and as directed by the Engineer–in–Charge.
110S&F 20mm bore gun–metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
111M&L for 75mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed by the Engineer–in–Charge
112M&L for PVC (SWR) gully trap 125/110mm, setting and jointing with solvent cement complete all as specified and as directed by the Engineer–in–Charge
113S&F 15mm bore stop valves /angle valve chromium plated fancy type, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
114S&F in repair single piece vitreous china water closet (WC and flushing cistern) alongwtih PP soft close seat cover, hinges, fixing accessories and accessories set, cistern fittings "S" or "P" Trap complete fixed as in repair complete all as specified and as directed by the Engineer-in-Charge.
115S&F in repair vitreous china table top /counter sunk wash hand basin white, of size 565mm x 420mm x 140mm fixed on and including cast iron cantilever bracket, 32mm dia brass waste coupling long screwed shank and fly nuts and 32 mm dia pvc corrugated waste pipe 900mm long including fixing of waste fitting etc complete all as specified and as directed by the Engineer-in-Charge.
116S&F heatlh faucet mild steel chromium plated suitable for 15mm dia pipe with 1.20 metre long flexible tube and wall hook including making connections and fixed in position complete all as specified and as directed by the Engineer–in–Charge.
117S&F sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed by Engineer–in–Charge.
118S&F in repair soap dish, vitreous china white, approximate size 160x160x90mm fixed to plugs with chromium plated brass screws complete all as specified.
119S&F toilet paper holder with flat recessed type stainless steel fixed to walls with chromium plated (CP) brass screws complete all as specified and directed."
120S&F stainless steel 304 grade wall mounted towel rack with lower hanging towel hooks 600 mm long and 250mm wide between flanges including brackets complete all as specified.
121S&F brass CP WHB /sink mixer swan neck for mixing hot & cold water for 15mm bore dia, pipes, screweddown for iron pipe and fixed complete all as specified and directed.
122M&L for granite (of any type) tiles 16–18mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing types over 15mm thick screed bed in CM 1:6 complete all as specified and directed.
123S&F 450x600mm belevelled edge mirror 5mm thick of selected quality glass mounted on 6mm thick AC bldg board or commercial plywood and fixed to wooden plugs with CP brass screws and cup washer complete all as specified.
124S&F brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and as directed by the Engineer–in–Charge
125M&L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B–1 smooth finished, and reforming benching as required for 100mm bore pipe line complete all as specified and as directed by the Engineer–in–Charge
126M&L for cement concrete bed 1:3:6, Type C–2 (using 40mm graded crushed stone aggregate) to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested, in
127M&L for providing cement concrete 1:2:4 Type B0 using 12.5mm graded aggregate as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed by the Engineer–in–Charge.
128M&L for precast cement concrete 1:2:4, Type B–1 (using 20 mm graded crushed stone aggregate) as in slab supported on walls, beams, chullah hood, chajja, column, culverts, manhole cover slabs similar type RCC works incuding demolition of existing RCC works complete all as specified.
129S&F for powder coated (50mic min thickness) aluminium frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc. complete shall as specified.
130S&F for powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws and hinge 100mm long all complete as per architectural drawings and the directions of Engineer–in–charge.
131S&F 4.80mm thick frosted sheet glass ordinary type and glazing with aluminium beading, rubber packing or oil putty in square n exc 0.5 sqm each pane complete all as specified and directed.
132S&F aluminium (die cast) body door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed.
133S&F floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified.
134S&F rubber strips 3 to 4 mm thick and 65 to 75 mm wide on bottom rail of door for covering gaps between door and floor to avoid entry of insects, dust etc and fixed with screws complete all as specified and as directed by the Engineer–in–Charge.
135S&F in repair stainless steel tubing of 25 mm dia chromium plated min 1.0 mm wall thickness as in curtain rod complete incl S&F 02 Nos stainless steel brackets/finials fancy type, stops fixed with ss screws etc complete fixed as in repair complete all as specified and as directed by the Engineer–in–Charge. Note : For the purpose of mesurement and payment running length of curtain rod only shall be considered.
136Dismantling of brick work or stone masonary, precast cement concrete walling built in cement mortar including all quoins, arches, pillars etc. complete all as specified.
137Demolition of cement concrete in ground floor and pavings not exceeding 15cm thickness (below or above ground level) and depositing the rubbish/ demolished material outside defence land, complete all as specified and directed.
138Note:-Amount of credit ofRs 63760.00 for retrieved materials is mentioned in Schedule of Credit attached in tender documents in pdf form which will be deducted offline while acceptance of tender.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail