Housing Urban and Rular Development Government Departments Closing in 0 days TDR #39502945

Tender For Repairing Of Existing Pump House And Existing Pipe Line Maintenance Of Hydrant Point, With Other Allied Works In Different Scheme Of Duski Section Under Dws Sub-Division, Teliamura.

Issued by Government Departments · kalyanpur, Tripura
Tender Value
5.26 Lakhs
Estimated cost
Bid Submission
20 Sep 2023
0 days left
EMD
10521
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
kalyanpur → Tripura
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Repairing Of Existing Pump House And Existing Pipe Line Maintenance Of Hydrant Point, With Other Allied Works In Different Scheme Of Duski Section Under Dws Sub-Division, Teliamura.

BOQ

Name of Work: Running Maintenance of JJM/RWS scheme during the year 2023-24/ S.H:-Repairing of existing Pump House and existing pipe line & maintenance of hydrant point, with other allied works in different scheme ofDuski Section under DWS Sub-Division, Teliamura.
Sl. No. Item Description
1Charges for repairing of leakage in UPVC/HDPE pipe line with PVC coupler & solvent cement etc. in/c necessary earth excavation backfilling of soil as required after laying of pipe line, in layers not exceeding 200 mm in depth in/c consolidating each deposited layer by ramming, watering etc complete as per specification of & direction of the Engineer in charge.
2i) 90mm OD
3ii) 110 mm OD
4iii) 140 mm OD
5Providing fixing and laying fabricated UPVC socket/coupler conforming to IS : 10124(part-2) with solvent cement conforming to IS : 14182 in/c testing of joint complete ( but excluding the cost of specials like bend, tees etc which will be paid separately) as per PWD Specification and direction of the Engineer in Charge.
6i)90mm OD
7ii) 110 mm OD
8iii) 140 mm OD
9Providing fixing and laying rigid UPVC pipes conforming to IS : 4985 jointing with cuplers of same class conforming to IS : 10124 ( Pt- II) with solvent cement conforming to IS : 14182 in/c testing of joint complete ( but excluding the cost of specials like bend, tees etc which will be paid separately) as per PWD Specification and direction of the Engineer in Charge.A. Class -3 ( Working pressure 6.0 kg/cm2)
10i) 40 mm OD
11ii) 90mm OD
12iii) 110 mm OD
13iv) 140 mm OD
14Providing fixing and laying fabricated UPVC bend of required degree conforming to IS: 10124 (P-8/9/10/ 11/12/13) with solvent cement conforming to IS:14182 in/c testing of joints complete as per chapter 20 of CPWD specification and direction of the Engineer in charge.
15i) 90 mm dia
16ii) 110 mm dia.
17iii) 140 mm dia.
18Providing fixing and laying fabricated UPVC end cap conforming to IS: 10124 (P-4) with solvent cement conforming to IS:14182 in/c testing of joints complete as per chapter 20 of CPWD specification and direction of the Engineer in charge.
19i) 90 mm dia
20ii) 110 mm dia.
21Reparing of leakage caused for damaged of lead joint at CI pipe/CI specials/ in/c excavation of earth as required upto 1.80 m depth cutting of bituminous red/WBM road (upto 3 or more layers) by 30 cm avaragedepth/soling road in/c dewatering side protection and making good the same with existing materials etc. complete in all respect as per direction of the Engineer in charge.
22i) 100 mm dia
23ii) 150 mm dia.
24Providing fixing and laying fabricated UPVC equal tee conforming to IS: 10124 (P-5) with solvent cement conforming to IS:14182 in/c testing of joints complete as per chapter 20 of CPWD specification and direction of the Engineer in charge.
25i) 90x90 mm dia
26ii) 110x110 mm dia.
27iii) 140x140 mm dia.
28Providing and fixing G.I. equal Tee with the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.
29i) 100x100 mm dia.
30ii) 150x150 mm dia.
31Providing fixing and laying fabricated UPVC straight reducer conforming to IS: 10124 (P-3) with solvent cement conforming to IS:14182 in/c testing of joints complete as per chapter 20 of CPWD specification and direction of the Engineer in charge.
32i) 110x90 mm dia
33ii) 140x110 mm dia.
34Providing fixing and laying fabricated UPVC tail piece with MS flange(8mm thick) conforming to IS: 10124 (P-6) with solvent cement conforming to IS:14182 in/c testing of joints complete as per chapter 20 of CPWD specification and direction of the Engineer in charge.
35i) 90 mm dia
36ii) 110 mm dia.
37iii) 140 mm dia.
38Providing and fitting fixing PVC / plastic bib cock conforming to IS : 9763 in hydrant points at different location as per specification & direction of the Engineer-in-charge.
39i. 15 mm dia PVC /plastic bib cock
40Proving & fixing GI full way valve as per chpater 20 of CPWD specification & direction of the Engineer in charge.
41i) 40 mm dia
42Providing & fixing bruss ferrule with CI cover conforming t0 IS:2692 in/c boaring and taping the main as per chapter 20 of CPWD specification and direction of Engineer in charge.
43i) 10 mm nominal bore
44ii) 15 mm nominal bore
45Providing & fixing of GI socketas CPWD specification & direction of Engineer in charge.
46i) 15 mm dia
47ii) 20 mm dia
48iii) 40 mm dia
49Providing & fixing of GI union jointsas per CPWD specification and direction of Engineer in charge
50i) 15mm dia
51ii) 20 mm dia.
52iii) 40 mm dia
53Providing & fixing GI Nipple of medium classas per chapter 20 of CPWD specification and direction of Engineer in charge.
54i) 15mm dia 75mm long
55ii) 15mm dia 150 mm long
56Providing & fixing GI reducer in the pipeline including testing of joints complete as CPWD specification & direction of incharge.
57i)20X15 mm
58ii) 40x15 mm dia
59iii) 100x80 mm dia
60iv) 150x80 mm dia
61v) 150x100 mm dia
62Providing & fixing GI bend/elbow in the pipeline including testing of joints complete as CPWD specification & direction of incharge.
63i)15 mm dia
64ii)20 mm dia.
65iii) 100 mm dia
66iv) 150 mm dia
67Making road crossing by horizantal boaring for smoothly lating of UPVC/CI/DI/GI pipe etc of requiered dia complete as per specification &direction of the Engineer in charge.
68B) By manual means
69Providing & fitting, fixing CI sluice Valve(with cap) complete with nuts, bolts, rubber insertion etc. (the tail piece if required will be paid separetely)
70i) 80 mm dia. (A) PN - 1.6
71ii) 100 mm dia. (A) PN - 1.6
72iii) 150mm dia. (A) PN - 1.6
73Providing & fitting fixing spindles for sluice valve of approved quality as per direction of the Engineer in charge.
74i) 100 mm dia
75ii) 150 mm dia.
76Providing lead chaulked joints to spun iron or CI pipes and specials in/c testing of joints but ex/c the cost of pig lead as pe chapter 20 of CPWD specification and the direction of the Engineer in charge.
77i) 80 mm dia
78ii) 100 mmdia
79iii) 150 mm dia
80Excavation trenches of required width for pipes etc. including excavation of sockets, dressing of sides, ramming of bottom, depth up to 1.5 m including getting out the excavated soil as required in layer not exceeding 20 cm in depth in consolidating each deposited layer by ramming, watering etc. & dressing of surplus excavated soil as directed within a lead of 50 m.(a) ordinary soilC) For UPVC pipes in old worka) In all kinds of soil
81i) for pipes not exceeding 90 mm OD
82ii) for pipe exceeding 90 mm OD but not exceeding 300 mm OD
83Providing & laying of Flexible pvc Pipe( conforming to IS : 7634) complete as per specificatio& direction of the Engineer In Charge ( cost of earth work & fittings will be paid separately)
84a) 15 mm dia
85b) 20 mm dia
86Providing and fixing G.I. pipes medim class as per IS : 1239 with latest amendment complete with G.I. fittings including trenching and refilling, cutting and making good the walls etc. complete as per CPWD specification and direction of the Engineer - in - charge.A. External work.
87i. 15 mm dia. nominal bore
88ii. 40 mm dia. nominal bore
89Labour for removal of deposited iron etc from the existing CI/DI pipe line by chain lead pully system attached with required dia cutter etc in/c necessary earth excavation of Engineer in charge. (pin poit for cutting of CI/DI pipe line will be as per direction of the Engineer in charge.
90b) 200 mm dia to 80 mm dia
91Disconnection of the Existing ferrule, GI socket, union joints, bend etc from main pipe line and plugging the existing ferrule hole with GI plug in/c necessary cutting earth and refilling the same etc complete as per direction of the Engineer in charge.
92Labour for removal of deposited iron forign materials etc from existing PVC pipe line by cgain lead pully system attached with required dia of cutter etc in/c necessary earth excavation dismantiling cutting relaying and jointing of pipes by making PVC coupler and solvent cement and refilling of earth etc complete as per direction of the Engineer in charge. (pin point for cutting of PVC pipe line will be as per direction of the Engineer in charge and as per actual site condition and necessary pipe for making coupler and solvent cement will be issued by the department at free of cost.
93a) 140 mm dia to 90 mm dia.
94Earthwork in excavation in all kinds of soil in foundation, trenches or drains(not exceeding 1.5 m in width or 10 sqm on plan ) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil, stacking the suitable soil properly for using the same in the building below floor and disposal of surplus excavated soil as directed, within a lead of 50 m as directed as perclauses of Chapter - 2 of CPWD specification.
95a) By manual means
96Supplying fitting fixing of following spare parts of approved quality suitable etc. as per direction of the Engineer-in-Charge.
97a) Full theraded nuts and bolt,10 mm dia, 50 mm long
98Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level andremoval of rubbish upto a distance of 50 m outside the periphery of the area cleared.
99Providing and fitting fixing of Fully Automatic Star Delta type Motor starter ( 3 ph. 50 Hz, 415V, in Steel Sheet Enclosures with Contractors and Timer etc. complete suitable for submersible Pump (L & T)as per specification and direction of the Engineer-in-charge.
100i) 25 HP/18.5 kw Relay range within 13-21 + 10%
101ii) 35 HP/26 kw Relay range within 20-32 + 10%
102Providing and fitting fixing steel sheet enclosed switch fuse unit(suitable for DIN fuses), triple pole with Neutral Link (TPN),415/500 Volt, L & T / Havells / BCH make etc. completeas per specification and direction of the Engineer-in-charge.
103(ii) 63 amps
104(iii) 100 amps
105Charges for making hole by drilling and making thread by thread bit in the CI / DI pipe as per specification & direction of the Engineer-in-charge.
106ii) 10 mm dia nominal bore

AI Tender Summary

OUR REF NO 39502945
AUTHORITY Government Departments
TENDER VALUE 5.26 Lakhs
LAST DATE 20-09-2023
Authority
Authority Name Public Works Department
Work Description Repairing Of Existing Pump House And Existing Pipe Line Maintenance Of Hydrant Point, With Other Allied Works In Different Scheme Of Duski Section Under Dws Sub-Division, Teliamura.
Basic Detail
Tender No 45/EE-KLP/PWD(DWS)/2023-24
Bidding Type Tender
Location
City kalyanpur
State Tripura
Key Dates
Publish Date 05 Sep 2023
Submission Date 20 Sep 2023
Open Date 20 Sep 2023
Finance
Tender Value 5.26 Lakhs
Tender Fee 1000
EMD 10521
Exemption Not Available
Document List
bdd754cf-f820-4b75-ab88-2a9814156c0b.html
BOQ_1028629.xls
DNIeT45.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 05, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 20, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Sep 20, 2023

Bid Opening Date

Technical bids will be opened and evaluated.