Bharat Sanchar Nigam Limited-BSNL has published Tender For Emergent Repair Work (Sh Restoration Of Water Supply Prevention Of Leakage Through Rcc Water Tanks) In 14 Nos T Ii S Qtrs At Lalbagh Colony Faizabad Distt Ayodhya. Submission Date for this Tender is 14-09-2023. Water Supply Tenders in ayodhya Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
2 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
3 | 15 mm cement plaster on rough side of single or half brick wall of mix : |
4 | 1:4 (1 cement: 4 coarse sand) |
5 | 20 mm cement plaster of mix : |
6 | 1:4 (1 cement: 4 coarse sand) |
7 | Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. |
8 | 12 mm cement plaster |
9 | 20 mm cement plaster |
10 | Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In- Charge. |
11 | Providing and fixing soil, waste and vent pipes : |
12 | 100 mm dia. |
13 | Sand cast iron S&S pipe as per IS: 1729. |
14 | 75 mm diameter : |
15 | Sand cast iron S&S pipe as per IS: 1729. |
16 | Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and includingcement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : |
17 | For 100 mm dia. Pipe |
18 | For 75 mm dia. Pipe |
19 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall |
20 | 15 mm nominal outer dia. Pipes. |
21 | 20 mm nominal outer dia. Pipes. |
22 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. :Concealed work, including cutting chases and making good the walls etc. |
23 | 15 mm nominal outer dia .Pipes. |
24 | 20 mm nominal outer dia .Pipes. |
25 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge : External work |
26 | 20 mm nominal outer dia. Pipes. |
27 | Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anticorrosive bitumastic paint, cutting chases and making good the wall: |
28 | 15 mm dia. nominal bore |
29 | 20 mm dia. nominal bore |
30 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. : External work |
31 | 20 mm dia. nominal bore |
32 | 25 mm dia. nominal bore |
33 | 32 mm dia. nominal bore |
34 | 40 mm dia. nominal bore |
35 | 50 mm dia. nominal bore |
36 | Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : |
37 | 20 mm nominal bore. |
38 | 25 mm nominal bore. |
39 | Providing and fixing PTMT bib cock of approved quality and colour. |
40 | 15mm nominal bore, 86 mm long. Weighing not less than 88 gms. |
41 | Providing and fixing PTMT pillar cock of approved quality and colour . |
42 | 15mm nominal bore, 107 mm long. Weighing not less than 110 gms. |
43 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. |
44 | 20 mm nominal bore, 120 mm long. Weighing not less than 198 gms. |
45 | Cleaning of all manhole / chambers of all sizes in the compound complete including cleaning of adjacent sewer line, removal of earth, silt, slush, brickbats, garbages and other refuses, disposing the same off to dumping site in township complete as per direction of Engineer-in-charge. Cleaning of manholes / chamber shall be done as & when required manually or mechanically. Note :- Rates includes the cost of cleaning of manhole /chamber , de-watering, if required including cleaning of adjacent sewer line , removing of manhole / chamber cover and keeping the same back in position after cleaning etc. complete. Payment will be made for each cleaning. |
46 | Taking out Pipal plant and other plant from walls and terrace including dismantaling brick work /Terrace treatment, uprooting and repairing the same including necessary scaffolding arrangement etc. Complete as per direction of engineer in charge.(If two or more sapling of Pipal trees and other plant are at same place that should be treated as one up to plan area of 0.5 sqm.) |
47 | Credit of unserviciable GI Pipe from 15 mm to 40 mm obtained from dismantelling etc. complete. |
48 | Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. |
49 | The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. |
50 | Note :- (1) The elevational area of the scaffolding shall be measured for payment purpose. |
51 | (2) The payment will be made once only for execution of all items for such works. |